Naturally occurring radioactive materials (NORM) in ashes from a fuel-oil power plant in Cienfuegos, Cuba, and the associated radiation hazards.

Abstract:

:The radioactivity of NORM was measured in ashes collected from a fuel-oil power plant in Cienfuegos, Cuba, using an HPGe gamma-ray spectrometer. The (226)Ra, (210)Pb, (40)K, (232)Th and (238)U activity concentrations reached 240, 77, 59, 70 and 15 Bq kg(-1), respectively. The potential radiological hazard of these residuals was assessed. The radium equivalent activities of the samples varied from 54 to 345 Bq kg(-1). The gamma index was calculated to be lower than that of the reference values, and the gamma absorbed dose rate was higher than the average reported for the earth's crust; however, the assessed annual effective dose was slightly lower than the annual effective dose limit for public, i.e. 1 mSv. Therefore, these bottom ashes were not dramatically enriched with radionuclides and may be used as an additive for building materials without restrictions from a radiological protection point of view.

journal_name

Radiat Prot Dosimetry

authors

Alonso-Hernández CM,Bernal-Castillo J,Morera-Gómez Y,Guillen-Arruebarrena A,Cartas-Aguila HA,Acosta-Milián R

doi

10.1093/rpd/nct237

subject

Has Abstract

pub_date

2014-03-01 00:00:00

pages

421-6

issue

4

eissn

0144-8420

issn

1742-3406

pii

nct237

journal_volume

158

pub_type

杂志文章
  • French population exposure to radon, terrestrial gamma and cosmic rays.

    abstract::In France, natural sources account for most of the population exposure to ionising radiation. This exposure varies widely with area. Radon and gamma-ray exposure data come from national measurement campaigns; cosmic doses were calculated from city altitude. These data were corrected for season of measurement, housing ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch463

    authors: Billon S,Morin A,Caër S,Baysson H,Gambard JP,Backe JC,Rannou A,Tirmarche M,Laurier D

    更新日期:2005-01-01 00:00:00

  • A fast response and gamma-insensitive neutron detector based on parallel-plate avalanche counter.

    abstract::The use of the parallel-plate avalanche counter for slow-neutron counting is described. The choice of a suitable neutron converter is discussed on the basis of Monte Carlo simulation, and some experimental results are shown. Excellent gamma-insensitivity, high rate capability, possibility of construction in large sens...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncm462

    authors: Nakhostin M,Baba M,Itoga T,Oishi T,Unno Y,Kamada S,Okuji T

    更新日期:2008-01-01 00:00:00

  • Thermoluminescence dosimetric characteristics of beta irradiated salt.

    abstract::The thermoluminescence (TL) characteristics of sodium chloride (NaCl), known as common salt, used for cooking purposes (iodised salt), have been studied in the present paper considering its usage as an 'accidental dosemeter' in the case of a nuclear fallout. TL characteristics of common salt have been examined under e...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci568

    authors: Murthy KV,Pallavi SP,Rahul G,Patel YS,Sai Prasad AS,Elangovan D

    更新日期:2006-01-01 00:00:00

  • LEAD COMPOSITE VS. NONLEAD PROTECTIVE GARMENTS: WHICH ARE BETTER? A MULTIVENDOR COMPARISON.

    abstract::This study aims to provide more insight in attenuation characteristics and corresponding lead (Pb) equivalences of a broad range of commercially available lead composite and nonlead protective garments. Thirty garments of five manufacturers (listed as 0.25-0.35-0.50 mm Pb equivalent) were tested. Transmission values w...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw373

    authors: Peters SMB,Zweers D,de Lange F,Mourik JEM

    更新日期:2017-08-01 00:00:00

  • The effect of dose heterogeneity on radiation risk in medical imaging.

    abstract::The current estimations of risk associated with medical imaging procedures rely on assessing the organ dose via direct measurements or simulation. The dose to each organ is assumed to be homogeneous. To take into account the differences in radiation sensitivities, the mean organ doses are weighted by a corresponding t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs275

    authors: Samei E,Li X,Chen B,Reiman R

    更新日期:2013-06-01 00:00:00

  • Active neutron dosemeters based on microdosimetric principles: research studies.

    abstract::Over the past few years, the Institute for Radiation Protection and Nuclear Safety (IRSN) has been studying a personal electronic neutron dosemeter and an ambient electronic neutron dosemeter based on experimental microdosimetric principles using low pressure proportional counters. The results obtained in 2000 and in ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006808

    authors: Ménard S,Chau Q,Lahaye T

    更新日期:2002-01-01 00:00:00

  • Modelling the 137Cs ingestion dose from consumption of marine fish in Hong Kong.

    abstract::This paper presents a compartmental model for estimating the ingestion dose, due to 137Cs, arising from the consumption of marine fish in Hong Kong. 137Cs is one of the more important radionuclides released in routine liquid effluents discharged from the Guangdong Nuclear Power Station at Daya Bay, which began commerc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006710

    authors: Poon CB,Au SM

    更新日期:2002-01-01 00:00:00

  • Comparison of various anthropomorphic phantom types for in vivo measurements by means of Monte Carlo simulations.

    abstract::Three widely used anthropomorphic phantoms are analysed with regard to their suitability for the efficiency calibration of whole-body counters (WBCs): a Bottle Manikin Absorber (BOMAB) phantom consisting of water-filled plastic containers, a St Petersburg block phantom (Research Institute of Sea Transport Hygiene, St ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq320

    authors: Schläger M

    更新日期:2011-03-01 00:00:00

  • ISFSI site boundary radiation dose rate analyses.

    abstract::Across the globe nuclear utilities are in the process of designing and analysing Independent Spent Fuel Storage Installations (ISFSI) for the purpose of above ground spent-fuel storage primarily to mitigate the filling of spent-fuel pools. Using a conjoining of discrete ordinates transport theory (DORT) and Monte Carl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci279

    authors: Hagler RJ,Fero AH

    更新日期:2005-01-01 00:00:00

  • Investigation of mean glandular dose versus compressed breast thickness relationship for mammography.

    abstract::The relationship between the mean glandular dose (MGD) and the compressed breast thickness (CBT) is commonly used for the presentation of mammographic dose survey results and could also be useful for the assessment of individual breast doses retrospectively in case of lack of necessary dosimetric instrumentation. The ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn140

    authors: Bor D,Tukel S,Olgar T,Toklu T,Aydin E,Akyol O

    更新日期:2008-01-01 00:00:00

  • Radiation dose aspects in the handling of emerging nuclear fuels.

    abstract::The occupational annual dose levels, encountered at fabrication of emerging nuclear fuels, have been studied. Emerging fuels for the single and multiple recycling of Pu and MA have resulted in considerably higher gamma and neutron doses in comparison with commercial fuels. The occupational dose limit is exceeded at fa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu016

    authors: Nicolaou G

    更新日期:2014-12-01 00:00:00

  • Development of a new passive integral dosemeter for gamma ray monitoring using an imaging plate.

    abstract::A new passive integral dosemeter for gamma ray monitoring is being developed using an imaging plate (IP). In the application of IPs to dosimetry, a fading effect causes serious problems. The fading is considered to be caused by the recombination or holes and charges trapped shallowly in the F centres, which have sever...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006396

    authors: Ohuchi H,Yamadera A,Baba M

    更新日期:2003-01-01 00:00:00

  • Criteria and suspension levels in diagnostic radiology.

    abstract::The EC (European Council) Directive on radiation protection of patients requires that criteria for acceptability of equipment in diagnostic radiology, nuclear medicine and radiotherapy be established throughout the member states. This study reviews the background to this requirement and to its implementation in practi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncs295

    authors: Malone J,Baldelli P,Balter S,Bischof N,Bosmans H,Dowling A,Edyvean S,Gallagher A,Faulkner K,Horner K,Malone L,Mclean ID,O'Connor U,Schreiner A,Vassileva J,Vano E,Zoetelief J

    更新日期:2013-02-01 00:00:00

  • CAN HALF VALUE LAYER MEASUREMENTS BE USED TOGETHER WITH THE EFFECTIVE ENERGY TO OBTAIN CONVERSION COEFFICIENTS FOR X-RAY SPECTRA?

    abstract::Conversion coefficients are a substantial vehicle in practical radiation protection to determine the dose (rate) of a given radiation field. According to ICRU report 57, their values shall be obtained by means of spectrometry. This is, however, a time-consuming complicated procedure that cannot be performed by all dos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw003

    authors: Behnke B,Hupe O

    更新日期:2017-04-15 00:00:00

  • Long-term monitoring of radiation exposure of employees in the department of nuclear medicine (Szczecin, Poland) in the years 1991-2007.

    abstract::Occupational radiation exposure is a hazard that should be avoided or at least minimised. This study aimed to evaluate the radiation exposure of nuclear medicine department employees monitored during the 1991-2007 period, and to investigate the relationship between the annual effective doses of the personnel and the n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq117

    authors: Piwowarska-Bilska H,Birkenfeld B,Listewnik M,Zorga P

    更新日期:2010-08-01 00:00:00

  • Implications of the space radiation environment for human exploration in deep space.

    abstract::Human exploration of the solar system beyond Earth's orbit will entail many risks for the crew on these deep space missions. One of the most significant health risks is exposure to the harsh space radiation environment beyond the protection provided by the Earth's intrinsic magnetic field. Crew on exploration missions...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci141

    authors: Townsend LW

    更新日期:2005-01-01 00:00:00

  • ORGAN ABSORBED DOSE ESTIMATION REFLECTING SPECIFIC ORGAN MASSES WITH SIMPLE SCALING OF REFERENCE DOSES USING THE ORGAN MASSES.

    abstract::Estimating organ absorbed doses in consideration of person-specific parameters is important for radiation protection in diagnostic nuclear medicine. This study proposes a straightforward method for estimating the organ dose that reflects a specific organ mass by scaling the reference organ dose using the inverse ratio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa058

    authors: Manabe K,Koyama S

    更新日期:2020-07-24 00:00:00

  • Detection system built from commercial integrated circuits for real-time measurement of radiation dose and quality using the variance method.

    abstract::A small, specialised amplifier using commercial integrated circuits (ICs) was developed to measure radiation dose and quality in real time using a microdosimetric ion chamber and the variance method. The charges from a microdosimetric ion chamber, operated in the current mode, were repeatedly collected for a fixed per...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm231

    authors: Hsu WH,Braby LA,Reece WD

    更新日期:2008-01-01 00:00:00

  • In vivo thermoluminescence dosimetry for total body irradiation.

    abstract::An improvement in the clinical results obtained using total body irradiation (TBI) with photon beams requires precise TBI treatment planning, reproducible irradiation, precise in vivo dosimetry, accurate documentation and careful evaluation. In vivo dosimetry using LiF Harshaw TLD-100 chips was used during the TBI tre...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006058

    authors: Palkosková P,Hlavata H,Dvorák P,Novotný J,Novotný J Jr

    更新日期:2002-01-01 00:00:00

  • Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote afterloader.

    abstract::In support of the effort to begin high-dose rate 252Cf brachytherapy treatments at Tufts-New England Medical Center, the shielding capabilities of a clinical accelerator vault against the neutron and photon emissions from a 1.124 mg 252Cf source were examined. Outside the clinical accelerator vault, the fast neutron d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch473

    authors: Melhus CS,Rivard MJ,Kurkomelis J,Liddle CB,Massé FX

    更新日期:2005-01-01 00:00:00

  • NEURAL NETWORK MODELLING OF CARDIAC DOSE CONVERSION COEFFICIENT FOR ARBITRARY X-RAY SPECTRA.

    abstract::In this article, an approach to compute the dose conversion coefficients (DCCs) is described for the computational voxel phantom 'High-Definition Reference Korean-Man' (HDRK-Man) using artificial neural networks (ANN). For this purpose, the voxel phantom was implemented into the Monte Carlo (MC) transport toolkit GEAN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv436

    authors: Kadri O,Manai K

    更新日期:2016-12-01 00:00:00

  • Absorbed dose rate estimation for protons, leptons and helium observed with AMS01 experiment in low earth orbit during STS-91 mission.

    abstract::The Alpha Magnetic Spectrometer (AMS01), a high-sensitivity particle spectrometer, was successfully flown for 10 d in June 1998 (STS91) in the orbit of the International Space Station (51.7 degrees, -380 km). A high-statistics dataset of galactic cosmic rays were measured as a function of geomagnetic latitude, includi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci071

    authors: Ionica M,Alpat B,Ambrosi G,Battiston R,Bertucci B,Burger WJ,Caraffini D,Cecchi C,Dinu N,Esposito G,Fiandrini E,Ionica R,Menichelli M,Pauluzzi M,Zuccon P

    更新日期:2005-01-01 00:00:00

  • Dutch distribution zones of stable iodine tablets based on atmospheric dispersion modelling of accidental releases from nuclear power plants.

    abstract::Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq114

    authors: Kok-Palma Y,Leenders M,Meulenbelt J

    更新日期:2010-08-01 00:00:00

  • COVERING THE PATIENT'S ARM SUPPORT IN LEAD REDUCED THE RADIATION DOSE RATE TO THE CARDIOLOGISTS DURING PERCUTANEOUS CORONARY INTERVENTIONS: A PHANTOM STUDY.

    abstract::The aim of the study was to estimate organ dose rate reduction to a female anthropomorphic phantom, which simulated the cardiologist, during percutaneous coronary interventions (PCI) when the patient's arm support was covered with 0.4-mm lead foil. Organ dose rates were determined using five radiation detectors insert...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz292

    authors: Fukuda A,Lin PP

    更新日期:2020-06-24 00:00:00

  • EXPOSURE ASSESSMENT OF PORTABLE WIRELESS DEVICES ABOVE 6 GHz.

    abstract::The emerging 5 G wireless devices working at frequencies above 6 GHz are expected to have antenna arrays formed by dipoles, slots, patches or their combination. At lower frequencies, the accepted criteria for exposure compliance is stated in terms of specific absorption rate. IEEE and ICNIRP are adopting epithelial or...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy177

    authors: Carrasco E,Colombi D,Foster KR,Ziskin M,Balzano Q

    更新日期:2019-06-01 00:00:00

  • A MULTI-ELEMENT THICK GAS ELECTRON MULTIPLIER-BASED MICRODOSEMETER FOR MEASUREMENT OF NEUTRONS DOSE-EQUIVALENT: A MONTE CARLO STUDY.

    abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx024

    authors: Moslehi A,Raisali G

    更新日期:2017-11-01 00:00:00

  • Dental CBCT equipment and performance issues.

    abstract::Dental cone beam computed tomography (CBCT), also known as digital volumetric tomography was developed in the late 1990s and is now increasingly available in clinical practice. It can provide high resolution cross-sectional images of teeth and the maxillofacial region with applications in all branches of dentistry. As...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncs289

    authors: Horner K,Jacobs R,Schulze R

    更新日期:2013-02-01 00:00:00

  • Maximum likelihood estimates of mean and variance of occupation radiation doses subjected to minimum detection levels.

    abstract::Data collection and its analysis in the field of nuclear safety is an important task in the sense that it powers the improvement of safety as well as reliability of the plant. Thus, occupational exposure data analysis is presented to measure the safety or reliability of radiation protection of a given facility. It als...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm483

    authors: Datta D,Singh S,Johnson BE,Kushwaha HS

    更新日期:2008-01-01 00:00:00

  • Assessment of gamma dose rates in air in Adana/Turkey.

    abstract::This study assesses the outdoor gamma absorbed dose levels in air of the Adana's region. The measurements were taken from 130 different sample points in this area by Eberline Smart Portable (ESP-2) with SPA-6 plastic scintillation detector. The outdoor gamma absorbed dose rates order from 40 to 145 nGy h(-1). Average ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn295

    authors: Degerlier M,Ozger G

    更新日期:2008-01-01 00:00:00

  • STUDY OF 222RN CONTINUOUS MONITORING TIME SERIES AND DOSE ASSESSMENT IN SIX EUROPEAN CAVES.

    abstract::The present work aims to assess the effective doses from long-term continual radon monitoring in six European caves (Slovenia, Slovakia and the Czech Republic), including influencing environmental factors. Caves are important radiation protection subjects because of elevated radon activity concentration (~kBq/m3), mos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa159

    authors: Ambrosino F,Thinová L,Briestenský M,Sabbarese C

    更新日期:2020-11-27 00:00:00