Dental CBCT equipment and performance issues.

Abstract:

:Dental cone beam computed tomography (CBCT), also known as digital volumetric tomography was developed in the late 1990s and is now increasingly available in clinical practice. It can provide high resolution cross-sectional images of teeth and the maxillofacial region with applications in all branches of dentistry. As a new imaging modality, there were no established suspension levels at a European level. A literature review, encompassing scientific, professional publications and existing national guidelines was performed in an attempt to develop a set of suspension levels for dental CBCT, using additional expert opinion from the members of the European Academy of dento-maxillo-facial radiology. A limited set of suspension levels has been devised for aspects of the X-ray tube and generator, dosimetry, field-of-view, alignment and image quality. These should be kept under review in the light of growing experience of testing equipment in practice.

journal_name

Radiat Prot Dosimetry

authors

Horner K,Jacobs R,Schulze R

doi

10.1093/rpd/ncs289

subject

Has Abstract

pub_date

2013-02-01 00:00:00

pages

212-8

issue

2

eissn

0144-8420

issn

1742-3406

pii

ncs289

journal_volume

153

pub_type

杂志文章,评审
  • AMANDE: a new facility for monoenergetic neutron fields production between 2 keV and 20 MeV.

    abstract::The variation of the response of the instruments with the neutron energy has to be determined in well-characterized monoenergetic neutron fields. The AMANDE facility will deliver such neutron fields between 2 keV and 20 MeV in an experimental hall designed with metallic walls for neutron scattering minimisation. The n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch185

    authors: Gressier V,Guerre-Chaley JF,Lacoste V,Lebreton L,Pelcot G,Pochat JL,Bolognese-Milstajn T,Champion D

    更新日期:2004-01-01 00:00:00

  • Optical absorption, TL and IRSL of basic plagioclase megacrysts from the pinacate (Sonora, Mexico) quaternary alkalic volcanics.

    abstract::The paper presents the first results of an investigation on optical absorption (OA), thermally and infrared stimulated luminescence (TL and IRSL) of the Pinacate plagioclase (labradorite). The OA spectra reveal two bands with maxima at 1.0 and 3.2 eV connected with absorption of the Fe3+ and Fe2+ and IR absorption at ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci643

    authors: Chernov V,Paz-Moreno F,Piters TM,Barboza-Flores M

    更新日期:2006-01-01 00:00:00

  • Natural radioactivity intake into wheat grown on fertilized farms in two districts of Pakistan.

    abstract::The use of phosphate fertilizers on agricultural farms enhances gamma-ray activity concentration in the farms and therefore absorbed dose rates to the public. The most common natural radionuclides in fertilizer and soil are (40)K, (226)Ra and (232)Th. Agricultural farms at four locations in two districts in Pakistan c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl100

    authors: Nasim-Akhtar,Tufail M

    更新日期:2007-01-01 00:00:00

  • Development of lung and soft tissue substitutes for photons.

    abstract::The use of solid tissue substitutes is a well-accepted and common practice in dosimetric studies and in the production of counting standards for radiological protection. However, only a few solid tissue substitutes simulating a particular body tissue with respect to a set of physical characteristics are commercially a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci018

    authors: Kinase S,Kimura M,Noguchi H,Yokoyama S

    更新日期:2005-01-01 00:00:00

  • ESTIMATION OF EXPOSURE DOSES FOR THE SAFE MANAGEMENT OF NORM WASTE DISPOSAL.

    abstract::Naturally occurring radioactive materials (NORM) wastes with different radiological characteristics are generated in several industries. The appropriate options for NORM waste management including disposal options should be discussed and established based on the act and regulation guidelines. Several studies calculate...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy041

    authors: Jeong J,Ko NY,Cho DK,Baik MH,Yoon KH

    更新日期:2018-11-01 00:00:00

  • In vivo thyroid 131I monitoring system using an imaging plate.

    abstract::The counting efficiency and detection limit of an in vivo thyroid 131I monitoring system using an imaging plate (IP) were estimated using an anthropomorphic thyroid neck phantom. The counting efficiency of the IP system was approximately constant for thyroid volumes between 11.7 and 20 ml and neck diameters between 10...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006025

    authors: Hirota M,Saze T,Nishizawa K

    更新日期:2002-01-01 00:00:00

  • New diagnostic reference level for full-field digital mammography units.

    abstract::The diagnostic reference level (DRL) has generally been defined as the 75th percentile of the distributions of mean doses observed on a sample of standard-sized patients, but for mammography, the 95th percentile has been used. In this study, the 75th and 95th percentiles are estimated for 26 full-field digital mammogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct136

    authors: Hauge IH,Bredholt K,Olerud HM

    更新日期:2013-12-01 00:00:00

  • Extremity dosimetry trial: Devonport Royal Dockyard.

    abstract::This trial was undertaken to assess extremity dosemeters, which were made available to Devonport Royal Dockyard and determine the most suitable to the site. The trial included operational and laboratory-based exposures. Operational exposures were within a submarine reactor compartment and a waste storage area. Laborat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn052

    authors: Kenyon R,Collison R

    更新日期:2008-01-01 00:00:00

  • A NEWLY DEVELOPED PHANTOM FOR PHYSICAL QUALITY ASSURANCE OF DENTAL CONE-BEAM COMPUTED TOMOGRAPHY.

    abstract::Two phantoms for a performance evaluation of cone-beam computed tomography (CBCT) were developed and their efficiency was tested. The first phantom, for low-contrast resolution, consisted of an acrylic circular plate with three 0.5-1.0 mm diameter rods. These rods enable the user to visually evaluate the limit of obse...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy116

    authors: Bamba J,Ishida H,Araki K

    更新日期:2019-05-01 00:00:00

  • Radiation exposure from radioactive iodine 131I in and surrounding the patients' room.

    abstract::The purpose of this study is to measure the environmental radiation exposure in and surrounding the room of patients treated with (131)I. Absorbed dose rates were measured using thermoluminescence dosemeters, type TLD-200 (CaF(2):Dy), in a continuous monitoring programme. It is found that the estimated annual shallow ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp093

    authors: Abu-Khaled YS,Sandouqa AS,Haddadin IM

    更新日期:2009-07-01 00:00:00

  • Studies on the current 137Cs body burden of children in Belarus--can the dose be further reduced?

    abstract::After the Chernobyl reactor accident wide areas of Belarus were contaminated with radioactive fallout. The verification and documentation of the long-term development of radiation doses is still going on. A population group of special concern are the children living in contaminated regions. The annual dose limit of 1 ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm153

    authors: Hill P,Schläger M,Vogel V,Hille R,Nesterenko AV,Nesterenko VB

    更新日期:2007-01-01 00:00:00

  • Optimised geometry to calculate dose rate conversion coefficient for external exposure to photons.

    abstract::A single-parameter geometry to describe soil is achieved for Monte Carlo calculation of absorbed dose rate in air for photon emitters from natural radionuclides. This optimised geometry based on physical assumptions consists of the soil part whose emitted radiation has a given minimum probability to reach the detector...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm426

    authors: Askri B,Manai K,Trabelsi A,Baccari B

    更新日期:2008-01-01 00:00:00

  • Radiation doses potentially received on-board aeroplanes during recent solar particle events.

    abstract::Because the doses received on-board aeroplanes are now monitored to fulfil legal requirements in some countries, including the European Community, the models to calculate doses received during solar events have left their purely academic status to become a part of operational systems as well. The present work consider...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci356

    authors: Lantos P

    更新日期:2006-01-01 00:00:00

  • Eu-doped CsBr phosphor as a new optically-stimulable phosphor material for medical X-ray imaging sensor.

    abstract::CsBr phosphor ceramics doped with different luminescence centres such as In2O3, Eu2O3, EuCl3, SmCl3, TbCl3, GdCl3 or NdCl3 as the candidate for a new optically-stimulable phosphor for medical X-ray imaging sensor were prepared using a conventional ceramic fabrication process. It was found that X-ray-irradiated Eu-dope...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci515

    authors: Kurata N,Kubota N,Takei Y,Nanto H

    更新日期:2006-01-01 00:00:00

  • THE IMPACT OF CIRCADIAN RHYTHMS ON MEDICAL IMAGING AND RADIOTHERAPY REGIMES FOR THE PAEDIATRIC PATIENT.

    abstract::Daily rhythmic changes are found in cellular events in cell cycle, DNA repair, apoptosis and angiogenesis in both normal and tumour tissue, as well as in enzymatic activity and drug metabolism. In this paper, we hypothesize that circadian rhythms need to be considered in radiation protection and optimization in person...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw328

    authors: Forssell-Aronsson E,Quinlan RA

    更新日期:2017-04-01 00:00:00

  • Measurements of radon and thoron progeny concentrations in dwellings of Tehri Garhwal, India, using LR-115 deposition-based DTPS/DRPS technique.

    abstract::This paper presents the values of radon and thoron progeny concentrations for different seasons in the dwellings of Tehri Garhwal, India. The measurements have been carried out using LR-115 solid-state nuclear track detector-based passive time-integrated direct thoron progeny sensor/direct radon progeny sensor techniq...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv224

    authors: Prasad M,Rawat M,Dangwal A,Yadav M,Gusain GS,Mishra R,Ramola RC

    更新日期:2015-11-01 00:00:00

  • Radiation safety assessment of a system of small reactors for distributed energy.

    abstract::A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, dee...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci208

    authors: Odano N,Ishida T

    更新日期:2005-01-01 00:00:00

  • Radiation effects in cultured tumour cells examined by 1H MRS: mobile lipids modulation and proliferative arrest.

    abstract::Much attention has been devoted in the past to monitor changes of mobile lipid (ML) (1)H MRS signals in spectra of tumour cells. The purpose of this work is to exploit ML signals to provide information on cell metabolism after irradiation, comparing tumour cells characterised by different radiosensitivity and relating...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl517

    authors: Grande S,Giovannini C,Luciani AM,Palma A,Rosi A,Sapora O,Viti V,Guidoni L

    更新日期:2006-01-01 00:00:00

  • Induced radioactivity in and around high-energy particle accelerators.

    abstract::Particle accelerators and their surroundings are locations of residual radioactivity production that is induced by the interaction of high-energy particles with matter. This paper gives an overview of the principles of activation caused at proton accelerators, which are the main machines operated at Conseil Européen p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr245

    authors: Vincke H,Theis C,Roesler S

    更新日期:2011-07-01 00:00:00

  • Assessment of gamma dose rates in air in Adana/Turkey.

    abstract::This study assesses the outdoor gamma absorbed dose levels in air of the Adana's region. The measurements were taken from 130 different sample points in this area by Eberline Smart Portable (ESP-2) with SPA-6 plastic scintillation detector. The outdoor gamma absorbed dose rates order from 40 to 145 nGy h(-1). Average ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn295

    authors: Degerlier M,Ozger G

    更新日期:2008-01-01 00:00:00

  • Digital dual-parameter data acquisition for SP2 hydrogen-filled proportional counters.

    abstract::Hydrogen-filled proportional counters perform well as neutron spectrometers in the energy region from a few tens of keV up to ∼1.5 MeV. Unfortunately, gamma rays also generate signals in these detectors. It is possible in principle to distinguish the two types of event via the rise time of their respective signal puls...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct262

    authors: Hawkes NP,Roberts NJ

    更新日期:2014-10-01 00:00:00

  • A fast response and gamma-insensitive neutron detector based on parallel-plate avalanche counter.

    abstract::The use of the parallel-plate avalanche counter for slow-neutron counting is described. The choice of a suitable neutron converter is discussed on the basis of Monte Carlo simulation, and some experimental results are shown. Excellent gamma-insensitivity, high rate capability, possibility of construction in large sens...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncm462

    authors: Nakhostin M,Baba M,Itoga T,Oishi T,Unno Y,Kamada S,Okuji T

    更新日期:2008-01-01 00:00:00

  • Non-radiation induced signals in TL dosimetry.

    abstract::One source of background signals, which are non-radiation related, is the reader system and it includes dark current, external contaminants and electronic spikes. These factors can induce signals equivalent to several hundredths of mSv. Mostly, the effects are minimised by proper design of the TLD reader, but some eff...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006064

    authors: German U,Weinstein M

    更新日期:2002-01-01 00:00:00

  • Measurement of natural radioactivity in building materials used in Urumqi, China.

    abstract::Building materials contain natural radionuclides (226)Ra, (232)Th and (40)K, which cause direct radiation exposure of the public. The concentrations of (226)Ra, (232)Th and (40)K in commonly used building materials of Urumqi, China have been analysed using gamma-ray spectrometry. The concentrations of (226)Ra, (40)K a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct002

    authors: Ding X,Lu X,Zhao C,Yang G,Li N

    更新日期:2013-07-01 00:00:00

  • Relative implications of protective responses versus damage induction at low dose and low-dose-rate exposures, using the microdose approach.

    abstract::In reviewing the tissue effects of low-dose radiation (1) absorbed dose to tissue is replaced by the sum of energy deposited with track events in cell-equivalent tissue micromasses, i.e. with microdose hits, in the number of exposed micromasses and (2) induced cell damage and adaptive protection are related to microdo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006197

    authors: Feinendegen LE

    更新日期:2003-01-01 00:00:00

  • Suggested diagnostic reference levels for paediatric X-ray examinations in India.

    abstract::Exposure of children to ionising radiation is considered to carry higher risk than that of adults; therefore a need to suggest diagnostic reference levels (DRLs) for the common paediatric diagnostic X-ray procedures was recognised for the X-ray machines meeting the requirements of the recently implemented Safety Code ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq458

    authors: Sonawane AU,Sunil Kumar JV,Singh M,Pradhan AS

    更新日期:2011-11-01 00:00:00

  • The efficiency of various thermoluminescence dosemeter types to heavy ions.

    abstract::Dose verification in heavy-ion beams using passive dosemeter systems, e.g. thermoluminescence dosemeters (TLDs), is crucial due to the changing efficiency of the dosemeters for different ion species and linear energy transfer (LET) values. This behaviour leads to a falsification of absorbed dose that can be significan...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci582

    authors: Berger T,Hajek M,Summerer L,Fugger M,Vana N

    更新日期:2006-01-01 00:00:00

  • Optimisation of a secondary standard chamber for the measurement of the ambient dose equivalent, H*(10), for low photon energies.

    abstract::A secondary standard ionisation chamber for photon radiation for measuring an ionisation current, which is directly proportional to the conventionally true value of the ambient dose equivalent, H*(10), was optimised. The chamber was developed in the Austrian Research Centers Seibersdorf and is used successfully worldw...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci334

    authors: Ankerhold U

    更新日期:2006-01-01 00:00:00

  • Measured and calculated angular responses of panasonic UD-809 thermoluminescence dosemeters to neutrons.

    abstract::Multi-element thermoluminescence dosemeters (TLD), such as the Panasonic UD-809, are used in personal dosimetry. The Panasonic UD-809 dosemeter consists of one gamma sensitive and three neutron sensitive TLD elements with different filter materials. In this work, the neutron energy responses (the number of (n,alpha) r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006517

    authors: Veinot KG,Hertel NE

    更新日期:2001-01-01 00:00:00

  • Evaluation of internal exposure of nuclear medicine staff through in vivo and in vitro bioassay techniques.

    abstract::The manipulation of a wide variety of unsealed sources in Nuclear Medicine results in a significant risk of internal exposure of the workers. 131I should be highlighted among the most frequently used radionuclides because of its large application for diagnosis and therapy of thyroid diseases. The increasing use of rad...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm365

    authors: Lucena EA,Rebelo AM,Araújo F,Sousa WO,Dantas AL,Dantas BM,Corbo R

    更新日期:2007-01-01 00:00:00