A NEWLY DEVELOPED PHANTOM FOR PHYSICAL QUALITY ASSURANCE OF DENTAL CONE-BEAM COMPUTED TOMOGRAPHY.

Abstract:

:Two phantoms for a performance evaluation of cone-beam computed tomography (CBCT) were developed and their efficiency was tested. The first phantom, for low-contrast resolution, consisted of an acrylic circular plate with three 0.5-1.0 mm diameter rods. These rods enable the user to visually evaluate the limit of observation. The second phantom, for geometric distortion, especially focused on the z-axis and consisted of two tabular acryl plates crossed perpendicularly with 1.0 mm-wide grooves in a grating form every 10.0 mm. The distances between the grooves on the axial and coronal images were evaluated. Five CBCT modalities were assessed using these phantoms. The contrast resolutions differed for each apparatus and set of exposure parameters. In terms of geometric distortion, some distortion was observed at the periphery of the field of view for both the axial and z-axis planes. These results suggest that our new phantoms can be used to evaluate CBCT.

journal_name

Radiat Prot Dosimetry

authors

Bamba J,Ishida H,Araki K

doi

10.1093/rpd/ncy116

subject

Has Abstract

pub_date

2019-05-01 00:00:00

pages

303-311

issue

3

eissn

0144-8420

issn

1742-3406

pii

5058992

journal_volume

183

pub_type

杂志文章
  • Transfer of alkaline earth elements in mothers' milk and doses from 45Ca, 90Sr and 226Ra.

    abstract::An international programme of work is currently under way to develop methods for calculating doses to infants from ingestion of radionuclides present in mothers' milk. This paper considers the special case of the alkaline earth elements. Models have been developed for 45Ca, 90Sr and 226Ra and the sensitivity of result...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006239

    authors: Smith TJ,Phipps AW,Fell TP,Harrison JD

    更新日期:2003-01-01 00:00:00

  • Review of the correlation between results of cytogenetic dosimetry from blood lymphocytes and EPR dosimetry from tooth enamel for victims of radiation accidents.

    abstract::The goal of this study was to compare dose estimates from electron paramagnetic resonance (EPR) dosimetry with teeth and cytogenetic dosimetry with blood lymphocytes for 30 victims of radiation accidents. The whole-body exposures estimated by tooth enamel EPR dosimetry were ranging from 0.01 to 9.3 Gy. Study group com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu203

    authors: Khvostunov IK,Ivannikov AI,Skvortsov VG,Nugis VY,Golub EV

    更新日期:2015-03-01 00:00:00

  • Emission rate estimation through data assimilation of gamma dose measurements in a Lagrangian atmospheric dispersion model.

    abstract::This paper presents an efficient algorithm for estimating the unknown emission rate of radionuclides in the atmosphere following a nuclear accident. The algorithm is based on assimilation of gamma dose rate measured data in a Lagrangian atmospheric dispersion model. Such models are used in the framework of nuclear eme...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq592

    authors: Tsiouri V,Kovalets I,Andronopoulos S,Bartzis JG

    更新日期:2012-01-01 00:00:00

  • Deposition of tritiated water vapour to water surface in an outdoor field.

    abstract::Deposition of tritiated water vapour in the atmosphere to a water surface was studied in an outdoor field, where elevated concentrations of tritiated water vapour existed in the atmosphere over twelve days. Exchange velocities of tritiated water vapour between air and water were evaluated from tritium concentrations i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006425

    authors: Noguchi H,Fukutani S,Yokoyama S,Kinouchi N

    更新日期:2001-01-01 00:00:00

  • CHARACTERISATION AND EVALUATION OF AL2O3:C-BASED OPTICALLY STIMULATED LUMINESCENT DOSEMETER SYSTEM FOR DIAGNOSTIC X-RAYS: PERSONAL AND IN VIVO DOSIMETRY.

    abstract::This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reade...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz186

    authors: Wong JHD,Bakhsh M,Cheah YY,Jong WL,Khor JS,Ng KH

    更新日期:2019-12-31 00:00:00

  • EMISSION OF SOIL GAS RADON CONCENTRATION AROUND MAIN CENTRAL THRUST IN UKHIMATH (RUDRAPRAYAG) REGION OF GARHWAL HIMALAYA.

    abstract::In this paper, the result of systematic measurement of the soil gas radon concentrations is discussed and the background values are defined along and around the Main Central Thrust (MCT) in Ukhimath region of Garhwal Himalaya, India. The Ukhimath region is being subjected to intense neotectonic activities like earthqu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw067

    authors: Aswal S,Kandari T,Sahoo BK,Bourai AA,Ramola RC

    更新日期:2016-10-01 00:00:00

  • MITOCHONDRIAL MEMBRANE POTENTIAL, MORPHOLOGY AND ATP PRODUCTION IN MAMMALIAN CELLS EXPOSED TO X-RAYS.

    abstract::This study aimed to reveal the effect of X-irradiation on mitochondrial function in terms of mitochondrial membrane potential (ΔΨm) and ATP productivity. At the cellular level, ΔΨm was quantified using JC-1, a mitochondrial probe that emits red or green fluorescence at high or low ΔΨm sites, respectively. The fluoresc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy254

    authors: Hamada R,Kaminaga K,Suzuki K,Yokoya A

    更新日期:2019-05-01 00:00:00

  • Fishing for radiation quality: chromosome aberrations and the role of radiation track structure.

    abstract::The yield of chromosome aberrations is not only dependent on dose but also on radiation quality, with high linear energy transfer (LET) typically having a greater biological effectiveness per unit dose than those of low-LET radiation. Differences in radiation track structure and cell morphology can also lead to quanti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv151

    authors: Hill MA

    更新日期:2015-09-01 00:00:00

  • Indoor radon measurements in the dwellings of Punjab and Himachal Pradesh, India.

    abstract::The measurement of indoor radon concentrations were performed in the dwellings of the Punjab and Himachal Pradesh, India by using LR-115 type II Solid-State Nuclear Track Detectors in the bare mode. The annual average indoor radon concentrations in the dwellings are found to vary from 114 to 400 Bq m(-3) with an avera...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct041

    authors: Rani A,Singh S,Duggal V

    更新日期:2013-01-01 00:00:00

  • Combined TL and 10B-alanine ESR dosimetry for BNCT.

    abstract::The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with (10)B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch110

    authors: Bartolotta A,D'Oca MC,Lo Giudice B,Brai M,Borio R,Forini N,Salvadori P,Manera S

    更新日期:2004-01-01 00:00:00

  • Thorium isotopic analysis by alpha spectrometry.

    abstract::The technique of alpha spectrometry is used to detect alpha particles and to determine their energy. In this way the technique is able to provide simultaneously quantitative information (i.e. the activity) and qualitative information (the identity) on any radionuclide that emits an alpha particle. The longer-lived nat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006646

    authors: Gingell T

    更新日期:2001-01-01 00:00:00

  • DETERMINATION OF DIAGNOSTIC REFERENCE LEVEL IN ROUTINE EXAMINATIONS OF DIGITAL RADIOGRAPHY IN MAZANDARAN PROVINCE.

    abstract:INTRODUCTION:The main purpose of this study was to determine the diagnostic reference level (DRL) for routine digital radiography examinations in Mazandaran province. MATERIALS AND METHODS:Thirteen digital radiographic examinations at 18 high-patient-load radiography centres were investigated. The indirect dosimetry m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa074

    authors: Hoseini Motlagh Z,Shabestani Monfared A,Deevband MR,Abedi-Firouzjah R,Ghaemian N,Abdi R,Ebrahimnejad Gorji K

    更新日期:2020-08-03 00:00:00

  • MODELLING THE INDOOR RADIATION DOSES: A REVIEW AND PERSPECTIVE.

    abstract::Theoretical models to calculate the indoor gamma and radon doses are reviewed, refined and applied. The model for gamma doses is built based on the relative effects of the different room elements that control the amount of radiation. The relative doses are calculated by the MCNP5 simulation software. The gamma sources...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncz008

    authors: Orabi M

    更新日期:2019-12-31 00:00:00

  • Design and manufacturing of anthropomorphic thyroid-neck phantom for use in nuclear medicine centres in Chile.

    abstract::Anthropomorphic phantoms are used in nuclear medicine for imaging quality control, calibration of gamma spectrometry system for the study of internal contamination with radionuclides and for internal dosimetric studies. These are constructed of materials that have radiation attenuation coefficients similar to those of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu022

    authors: Hermosilla A,Díaz Londoño G,García M,Ruíz F,Andrade P,Pérez A

    更新日期:2014-12-01 00:00:00

  • INFLUENCE OF STATIC ELECTRICITY ON RADON MEASUREMENT USING PASSIVE DETECTORS.

    abstract::In order to investigate the influence of the static electricity on the measurement using passive radon detector, detectors were charged at the surface of chamber and its CR-39 elements respectively on purpose before the exposure in this study. The results of in-chamber experiments revealed that the static electricity ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz067

    authors: Chen B,Zhao C,Fan D,Zhuo W

    更新日期:2019-10-01 00:00:00

  • Diagnostic reference levels in digital mammography: a systematic review.

    abstract::This study aims to review the literature on existing diagnostic reference levels (DRLs) in digital mammography and methodologies for establishing them. To this end, a systematic search through Medline, Cinahl, Web of Science, Scopus and Google scholar was conducted using search terms extracted from three terms: DRLs, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncu365

    authors: Suleiman ME,Brennan PC,McEntee MF

    更新日期:2015-12-01 00:00:00

  • Effective dose calculations in conventional diagnostic X-ray examinations for adult and paediatric patients in a large Italian hospital.

    abstract::The effective dose E is an efficient and powerful parameter to study the radioprotection of the patient. In our hospital, eight radiological departments and more than 100 radiological X-ray tubes are present. The effective doses were calculated for adults and paediatric patients in 10 standard projections. To calculat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch508

    authors: Compagnone G,Pagan L,Bergamini C

    更新日期:2005-01-01 00:00:00

  • A quality control programme for medical X-ray films in India.

    abstract::Medical X-ray films are continued to be the major image receptors in diagnostic radiology in India. About 9×10⁶ m² of medical X-ray films are used per annum for diagnostic imaging in India, and its magnitude may further increase as the number of diagnostic X-ray units is increasing rapidly. A national quality control ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq595

    authors: Sharma R,Sharma SD

    更新日期:2012-01-01 00:00:00

  • CALCULATION OF SKIN DOSE DUE TO BETA CONTAMINATION USING THE NEW QUANTITY OF THE ICRP 116: THE 'LOCAL SKIN DOSE'.

    abstract::Values of the new protection quantity 'Local Skin Dose' LSD, introduced by the International Commission on Radiological Protection (ICRP) Publication 116, were calculated for 134 β- or β+ emitting radionuclides, using the Monte Carlo code MCNP6. Two types of source geometry are considered: a point source and disc-type...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx019

    authors: Bourgois L,Ménard S,Comte N

    更新日期:2017-11-01 00:00:00

  • Long-term monitoring of radiation exposure of employees in the department of nuclear medicine (Szczecin, Poland) in the years 1991-2007.

    abstract::Occupational radiation exposure is a hazard that should be avoided or at least minimised. This study aimed to evaluate the radiation exposure of nuclear medicine department employees monitored during the 1991-2007 period, and to investigate the relationship between the annual effective doses of the personnel and the n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq117

    authors: Piwowarska-Bilska H,Birkenfeld B,Listewnik M,Zorga P

    更新日期:2010-08-01 00:00:00

  • BYSTANDER WI-38 CELLS MODULATE DNA DOUBLE-STRAND BREAK REPAIR IN MICROBEAM-TARGETED A549 CELLS THROUGH GAP JUNCTION INTERCELLULAR COMMUNICATION.

    abstract::Bi-directional signaling involved in radiation-induced bystander effect (RIBE) between irradiated carcinoma cells and their surrounding non-irradiated normal cells is relevant to radiation cancer therapy. Using the SPICE-NIRS microbeam, we delivered 500 protons to A549-GFP lung carcinoma cells, stably expressing H2B-G...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy249

    authors: Kobayashi A,Autsavapromporn N,Ahmad TAFT,Oikawa M,Homma-Takeda S,Furusawa Y,Wang J,Konishi T

    更新日期:2019-05-01 00:00:00

  • Bremsstrahlung and photoneutron production in a steel shield for 15-22-MeV clinical electron beams.

    abstract::The physical data regarding bremsstrahlung and neutrons produced in a steel shield by high-energy electron beams from a medical linear accelerator were investigated. These data are required to allow the accurate prediction of shielding performance for high-energy electron beams and in the design of radiotherapy facili...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu153

    authors: Fujita Y,Myojoyama A,Saitoh H

    更新日期:2015-02-01 00:00:00

  • Natural radioactivity levels in lake sediment samples.

    abstract::The radioactivity concentrations of nuclides (238)U, (232)Th and (40)K in lake sediments collected from 15 different stations at Altınkaya dam lake and 12 different stations at Derbent dam lake in Turkey were measured using high-resolution gamma-ray spectrometry. The measurement was done using a coaxial HPGe detector ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct071

    authors: Eroğlu H,Kabadayi Ö

    更新日期:2013-09-01 00:00:00

  • A fast response and gamma-insensitive neutron detector based on parallel-plate avalanche counter.

    abstract::The use of the parallel-plate avalanche counter for slow-neutron counting is described. The choice of a suitable neutron converter is discussed on the basis of Monte Carlo simulation, and some experimental results are shown. Excellent gamma-insensitivity, high rate capability, possibility of construction in large sens...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncm462

    authors: Nakhostin M,Baba M,Itoga T,Oishi T,Unno Y,Kamada S,Okuji T

    更新日期:2008-01-01 00:00:00

  • Uncertainty evaluation of radon measurements with LR115 detector and spark counter.

    abstract::To evaluate the uncertainties for nuclear track detectors used in radon measurements, a full understanding is required of the physical phenomena involved and the behaviour of the instruments utilised in the measuring process. As it concerns the LR115 nuclear track detector, an overall evaluation of uncertainty was giv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch361

    authors: Campi F,Caresana M,Ferrarini M,Garlati L,Palermo M,Rusconi R

    更新日期:2004-01-01 00:00:00

  • Dose trends in occupational radiation exposure in Europe results from the ESOREX project.

    abstract::The ESOREX project was initiated in 1997 by the EC DG TREN and it was executed by the BfS/Germany in close co-operation with the State Office for Nuclear Safety/Czech Republic). It consists of surveys on radiation monitoring and exposure carried out in the 30 European states. The study provides comparable descriptions...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl566

    authors: Frasch G,Petrová K

    更新日期:2007-01-01 00:00:00

  • A follow-up study on indoor 222Rn, 220Rn their decay product concentrations in a mineralised zone of Himachal Pradesh, India.

    abstract::A follow-up study was taken up in a mineralised zone situated in Hamirpur district, Himachal Pradesh, India, to investigate high values of radon concentrations reported in past studies as well to update the old radon data based on bare SSNTD technique. In the present investigation, the concentrations of indoor radon, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv367

    authors: Bajwa BS,Singh P,Singh P,Saini K,Singh S,Sahoo BK,Sapra BK

    更新日期:2016-03-01 00:00:00

  • Radiation effects in cultured tumour cells examined by 1H MRS: mobile lipids modulation and proliferative arrest.

    abstract::Much attention has been devoted in the past to monitor changes of mobile lipid (ML) (1)H MRS signals in spectra of tumour cells. The purpose of this work is to exploit ML signals to provide information on cell metabolism after irradiation, comparing tumour cells characterised by different radiosensitivity and relating...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl517

    authors: Grande S,Giovannini C,Luciani AM,Palma A,Rosi A,Sapora O,Viti V,Guidoni L

    更新日期:2006-01-01 00:00:00

  • Preliminary study of using imaging plates to map skin dose of patients in interventional radiology procedures.

    abstract::A method using europium-doped BaFBr imaging plates (IPs) has been studied for mapping entrance skin doses during interventional radiology (IR); the mapping is useful for detecting overlap between irradiation fields and determining the most exposed skin areas. IPs, which are two-dimensional radiation sensors made of ph...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch468

    authors: Ohuchi H,Satoh T,Eguchi Y,Mori K

    更新日期:2005-01-01 00:00:00

  • Evaluation of the radioactivity of the pre-dominant gamma emitters in components used at high-energy proton accelerator facilities.

    abstract::At a high-energy, high-intensity proton accelerator facility, the accelerator components inside the beam-line tunnel and the concrete wall of the tunnel are activated due to beam loss during operation. During maintenance work inside the tunnel, radiation emitted from these activated materials can cause exposure to rad...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl475

    authors: Numajiri M

    更新日期:2007-01-01 00:00:00