Measured and calculated angular responses of panasonic UD-809 thermoluminescence dosemeters to neutrons.

Abstract:

:Multi-element thermoluminescence dosemeters (TLD), such as the Panasonic UD-809, are used in personal dosimetry. The Panasonic UD-809 dosemeter consists of one gamma sensitive and three neutron sensitive TLD elements with different filter materials. In this work, the neutron energy responses (the number of (n,alpha) reactions per neutron) of the neutron-sensitive TLD elements of the Panasonic UD-809 dosemeter were calculated using the MCNP Monte Carlo transport code. Experiments were performed in a calibration geometry with an unmoderated 252Cf neutron source. These measurements were made with the dosemeter placed on the centre front face of a polymethylmethacrylate (PMMA) slab phantom. The phantom was rotated in the horizontal plane from -90 to +90 degrees, in 15 degree increments. Good agreement between calculated and measured element responses was observed. The angular dependency of personal dose equivalent was also calculated for parallel beams of 252Cf neutrons and compared to the TLD element angular responses.

journal_name

Radiat Prot Dosimetry

authors

Veinot KG,Hertel NE

doi

10.1093/oxfordjournals.rpd.a006517

keywords:

subject

Has Abstract

pub_date

2001-01-01 00:00:00

pages

25-30

issue

1

eissn

0144-8420

issn

1742-3406

journal_volume

95

pub_type

杂志文章
  • Calculation of conversion coefficients for clinical photon spectra using the MCNP code.

    abstract::In this work, the MCNP4B code has been employed to calculate conversion coefficients from air kerma to the ambient dose equivalent, H*(10)/Ka, for monoenergetic photon energies from 10 keV to 50 MeV, assuming the kerma approximation. Also estimated are the H*(10)/Ka for photon beams produced by linear accelerators, su...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch351

    authors: Lima MA,Silva AX,Crispim VR

    更新日期:2004-01-01 00:00:00

  • Luminescence dosimetry using building materials and personal objects.

    abstract::There is a growing public awareness of the risk of accidental radiation exposure due to ageing nuclear power installations, illegal dumping of nuclear waste and terrorist activities, and of the consequential health risks to populations in addition to social and economic disturbance extending beyond national boundaries...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci699

    authors: Göksu HY,Bailiff IK

    更新日期:2006-01-01 00:00:00

  • Performance of pellets and composites of natural colourless topaz as radiation dosemeters.

    abstract::The aim of the present work is to investigate the possibility of using the properties of the thermoluminescent emission (TL) of Brazilian natural topaz for dosimetric applications. Topaz is an aluminium fluorsilicate with general composition of Al2(SiO4)(F,OH)2 found with relative abundance in Brazil and in other part...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005902

    authors: Souza DN,Lima JF,Valerio ME,Caldas LV

    更新日期:2002-01-01 00:00:00

  • Issues, considerations and recommendations on emergency preparedness for vulnerable population groups.

    abstract::The Workshop on Emergency Preparedness for Vulnerable Population Groups was held on 2 and 3 March 2009 in Ottawa, ON, Canada. The purpose of the workshop was to enhance communications within the emergency community response network and to identify the needs and gaps of emergency preparedness against chemical, biologic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp083

    authors: Chen J,Wilkinson D,Richardson RB,Waruszynski B

    更新日期:2009-06-01 00:00:00

  • Applicability of convex hull in multiple detector response space for neutron dose measurements.

    abstract::A novel neutron dose measurement method that flexibly responds to variations in the neutron field is being developed by Japan Atomic Energy Agency. This is an implementation of the multi-detector method (first introduced in 1960s) for neutron dose evaluation using a convex hull in the response space defined for multip...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp134

    authors: Hashimoto M,Iimoto T,Kosako T

    更新日期:2009-08-01 00:00:00

  • CYTOGENETIC BIODOSIMETRY OF ACCIDENTAL EXPOSURES IN THE LONG TERMS AFTER IRRADIATION.

    abstract::The group of radiation victims who had received radiation injures similar to those of Chernobyl accident victims was evaluated in terms of retrospective cytogenetic biodosimetry in the long term period of from 17 y up to 50 y after irradiation. Based on the existing results of the long-term cytogenetic examination of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz040

    authors: Nugis VY,Kozlova MG,Nadejina NM,Galstyan IA,Nikitina VA,Khvostunov IK,Golub EV

    更新日期:2019-12-31 00:00:00

  • Long-term monitoring of radiation exposure of employees in the department of nuclear medicine (Szczecin, Poland) in the years 1991-2007.

    abstract::Occupational radiation exposure is a hazard that should be avoided or at least minimised. This study aimed to evaluate the radiation exposure of nuclear medicine department employees monitored during the 1991-2007 period, and to investigate the relationship between the annual effective doses of the personnel and the n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq117

    authors: Piwowarska-Bilska H,Birkenfeld B,Listewnik M,Zorga P

    更新日期:2010-08-01 00:00:00

  • On the use of LiF TLD-600 in neutron-gamma mixed fields.

    abstract::A new procedure allowing the separate estimation of neutron and gamma dose in mixed radiation fields has been developed in our laboratory. In this communication, a description of the main features of the discrimination procedure and some preliminary results obtained by its use are presented. The procedure is based on ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm210

    authors: Delgado A,Muñiz JL,Gómez Ros JM,Romero AM,Rodríguez R

    更新日期:2007-01-01 00:00:00

  • Diagnostic reference levels in digital mammography: a systematic review.

    abstract::This study aims to review the literature on existing diagnostic reference levels (DRLs) in digital mammography and methodologies for establishing them. To this end, a systematic search through Medline, Cinahl, Web of Science, Scopus and Google scholar was conducted using search terms extracted from three terms: DRLs, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncu365

    authors: Suleiman ME,Brennan PC,McEntee MF

    更新日期:2015-12-01 00:00:00

  • 226Ra AND 228Ra CONCENTRATIONS IN SOILS WITH INTENSE GROUNDWATER IRRIGATION IN AN ARID ENVIRONMENT.

    abstract::The enhancing effect due to long-time irrigation with radium-containing groundwater on soil was investigated in this work. Samples from the Al-Qassim and Hail areas in Saudi Arabia were studied for their 226Ra and 228Ra inventories. Groundwater and soil samples were collected from 32 farms where agricultural activitie...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz287

    authors: Ebaid YY

    更新日期:2020-06-24 00:00:00

  • Natural radioactivity measurements in building materials used in Samsun, Turkey.

    abstract::In this study, radioactivity levels of 35 different samples of 11 commonly used building materials in Samsun were measured by using a gamma spectrometry system. The analysis carried out with the high purity Germanium gamma spectrometry system. Radioactivity concentrations of (226)Ra, (232)Th and (40)K range from 6 to ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct047

    authors: Tufan MÇ,Disci T

    更新日期:2013-01-01 00:00:00

  • A TLD-based personal dosemeter system for aircrew monitoring.

    abstract::Evaluation of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) according to the high-temperature ratio (HTR) method enables the determination of the dose-average linear energy transfer (LET), the mean quality factor and the dose equivalent in mixed radiation fields of unknown composition. The neutron contribution is ass...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch209

    authors: Hajek M,Berger T,Vana N

    更新日期:2004-01-01 00:00:00

  • A comparative study of dielectric response function models for liquid water.

    abstract::Various methodologies that aim at an analytic representation of the dielectric response function (DRF) of liquid water with emphasis on the Bethe ridge region are compared. The use of optical data is a common feature to all models presented providing an empirical ground for modelling the valence energy losses where ma...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl414

    authors: Emfietzoglou D,Nikjoo H,Pathak A

    更新日期:2006-01-01 00:00:00

  • Canadian national internal dosimetry performance testing programme: results of the pilot programme.

    abstract::This paper describes the design and construction of a new performance testing programme that was implemented in Canada in 2008. The Canadian Regulator (Canadian Nuclear Safety Commission) had determined that their licensees, in addition to participating in the existing in vivo and in vitro performance tests, needed to...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp088

    authors: Kramer GH

    更新日期:2009-06-01 00:00:00

  • One cubic metre NIST traceable radon test chamber.

    abstract::With the availability of the National Institute of Standards and Technology (NIST) Radon Emanation Standard with a content of approximately 5000 Bq of 226Ra, it is possible to build a flow through a practical radon test chamber. A standard glove box with four gloves and a transfer port is used. Air is pumped through a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm430

    authors: Kotrappa P,Stieff F

    更新日期:2008-01-01 00:00:00

  • Methods and materials for the measurement of subjective and objective measurements of image quality.

    abstract::The evaluation of medical imaging systems may be performed using both subjective (e.g. high contrast limiting resolution, and low contrast detail detectability), and objective/physical (e.g. characteristic curve, signal-to-noise ratio, modulation transfer function, and Wiener spectra) indices of image quality. For the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006476

    authors: Marsh DM,Malone JF

    更新日期:2001-01-01 00:00:00

  • The analysis of thermoluminescent glow peaks of natural calcite after beta irradiation.

    abstract::In this study, the thermoluminescence properties of natural calcite samples were examined in detail. The glow curve of the sample irradiated with beta radiation shows two main peaks, P1 (at 115 °C) and P4 (at 254 °C). The additive dose, variable heating rate, computer glow curve deconvolution, peak shape and three poi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs020

    authors: Yildirim RG,Kafadar VE,Yazici AN,Gün E

    更新日期:2012-09-01 00:00:00

  • A comparative review of charged particle microbeam facilities.

    abstract::At the low doses (and low dose rates) relevant to environmental and occupational radiation exposure (0-50 mSv), which are of practical concern for radiation protection, very few cells in the human organism experience more than one traversal by densely ionising particles in their lifetime, the intervals between the tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncl444

    authors: Gerardi S

    更新日期:2006-01-01 00:00:00

  • Assessment of occupational exposure to uranium by indirect methods needs information on natural background variations.

    abstract::Urine monitoring is the preferred method to determine exposure to soluble compounds of uranium in workplaces. The interpretation of uranium contents in workers bioassay samples requires knowledge on uranium excretion and its dependence on intake by diet. Exceptionally high concentrations of natural uranium in private ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm155

    authors: Muikku M,Heikkinen T,Puhakainen M,Rahola T,Salonen L

    更新日期:2007-01-01 00:00:00

  • Review of Bayesian statistical analysis methods for cytogenetic radiation biodosimetry, with a practical example.

    abstract::Classical methods of assessing the uncertainty associated with radiation doses estimated using cytogenetic techniques are now extremely well defined. However, several authors have suggested that a Bayesian approach to uncertainty estimation may be more suitable for cytogenetic data, which are inherently stochastic in ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/nct301

    authors: Ainsbury EA,Vinnikov VA,Puig P,Higueras M,Maznyk NA,Lloyd DC,Rothkamm K

    更新日期:2014-12-01 00:00:00

  • Minimising activity and dose with enhanced image quality by radiopharmaceutical administrations.

    abstract::Owing to the introduction of new diagnostic procedures, such as computed tomography (CT), positron emission tomography (PET) and single photon emission computed tomography (SPECT), the individual dose caused by medical exposures has grown rapidly in the last years. This is especially a subject to radiation protection ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq104

    authors: Hoeschen C,Mattsson S,Cantone MC,Mikuz M,Lacasta C,Ebel G,Clinthorne N,Giussani A

    更新日期:2010-04-01 00:00:00

  • Exposures from nuclear medicine diagnostic procedures: the dose impact on the Aosta Valley population.

    abstract::The present work evaluates the per-procedure, annual collective and per-capita effective doses to the Aosta Valley region population from nuclear medicine (NM) examinations performed from 2005 to 2011 at the regional NM department. Based on its demographical and socioeconomics characteristics, this area can be conside...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct158

    authors: Aimonetto S,Arrichiello C,Peruzzo Cornetto A,Catuzzo P,Zeverino M,Poti C,Meloni T,Pasquino M,Tofani S

    更新日期:2013-12-01 00:00:00

  • Calculation and Validation of the Response Matrix for a Neutron Multisphere Spectrometer with an Indium Central Detector.

    abstract::Expansion of accelerator technologies into different application areas brings the need for neutron-field measurements in their vicinity. The measurements of neutron energy spectra and neutron dose rates can be done with the aid of neutron multisphere spectrometers with passive neutron detectors. In addition to the usu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx183

    authors: Vlk P,Pavlovic M

    更新日期:2018-04-01 00:00:00

  • Defect complexes in Re3+-doped magnesium sulphate phosphors.

    abstract::A series of magnesium sulphate phosphors MgSO4:RE3+,X ( RE = Dy, Tm, Eu and X = P, Mn) have been prepared and studied. Based on the experimental results of thermoluminescence (TL) emission spectra and dose responses studies, it is proposed that in these phosphors large defect complexes are formed, which include intrin...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci680

    authors: Luo DL,Tang Q,Zhang CX

    更新日期:2006-01-01 00:00:00

  • Mechanistic modelling of radiation-induced bystander effects.

    abstract::A model of radiation-induced bystander effects is presented that explicitly takes into account the transient nature of bystander signal emission post-irradiation, signal lifetime and the non-linear cellular response to the signals. Data are analysed on mutagenesis induced in human lymphoblasts in medium transfer exper...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv170

    authors: Kundrát P,Friedland W

    更新日期:2015-09-01 00:00:00

  • Dose distribution in the Russian Segment of the International Space Station.

    abstract::Absorbed dose and average linear energy transfer (LET) were assessed by means of (7)LiF:Mg,Ti (TLD-700) thermoluminescent (TL) detectors for different panels on-board the Russian Segment of the International Space Station in the timeframe between March and November 2002 (233 d). A technique is presented to correct the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci566

    authors: Hajek M,Berger T,Fugger M,Fürstner M,Vana N,Akatov Y,Shurshakov V,Arkhangelsky V

    更新日期:2006-01-01 00:00:00

  • Measurements of environmental background radiation at location of coal-fired power plants.

    abstract::Environmental radiation monitoring in the vicinity of coal-fired power plants which are used primarily to determine the variability in measured background exposures are presented in this article; this is in order to estimate the contribution due to the plants' operation. Measurements have been done using a multi-eleme...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch401

    authors: Adrovic F,Prokić M,Ninković MM,Glisić R

    更新日期:2004-01-01 00:00:00

  • Radiation exposure from radioactive iodine 131I in and surrounding the patients' room.

    abstract::The purpose of this study is to measure the environmental radiation exposure in and surrounding the room of patients treated with (131)I. Absorbed dose rates were measured using thermoluminescence dosemeters, type TLD-200 (CaF(2):Dy), in a continuous monitoring programme. It is found that the estimated annual shallow ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp093

    authors: Abu-Khaled YS,Sandouqa AS,Haddadin IM

    更新日期:2009-07-01 00:00:00

  • Neutron and photon fields in the BNCT room with closed beam shutters.

    abstract::The epithermal neutron beam at the LVR-15 reactor was designed for the Boron Neutron Capture Therapy (BNCT) of cancers, but it has also been used for material testing. In the case where the beam is closed with two designed shutters, there is still an indispensable background in the irradiation room, which limits the m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci112

    authors: Marek M,Viererbl L

    更新日期:2005-01-01 00:00:00

  • Can default ICRP f1 values be applied to determine radiation dose from the intake of diet-incorporated thorium?

    abstract::Data on the daily urinary excretion of thorium (Th) was obtained from 15 non-exposed adult German subjects. A radiochemical neutron activation analysis method was developed and standardised especially for this purpose. The daily urinary excretion of 232Th was found to be in the range 1.9-14.9 microBq d(-1) with a mean...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch482

    authors: Höllriegl V,Li WB,Oeh U,Röhmuss M,Roth P

    更新日期:2005-01-01 00:00:00