Measurements of environmental background radiation at location of coal-fired power plants.

Abstract:

:Environmental radiation monitoring in the vicinity of coal-fired power plants which are used primarily to determine the variability in measured background exposures are presented in this article; this is in order to estimate the contribution due to the plants' operation. Measurements have been done using a multi-element, high sensitive dosemeter system composed of three solid, properly filtered, sintered CaSO4:Dy thermoluminescent detectors, and one low-atomic number, MgB4O7:Dy,Na thermoluminiscencent detector produced at the Vinca Institute. The dosemeters were deployed quarterly 1 m above ground level at locations within 20 km of the power plants. Twenty urban and suburban measured stations were established. Measurements were carried out over one year period, from the beginning of the summer of 1995 to the end of the spring of 1996. The registered annual absorbed dose in air, from all of the 20 stations, vary from 0.91 to 1.46 mGy a(-1). One of the highest values of the annual absorbed dose was measured at the station near to the plant, i.e. at the place the most exposed to the lighter fly ash from the plant stack, as it was expected. The annual absorbed dose registered at the measuring stations that were selected as a control because they were situated practically away from possible influence of the plants were from 0.91 to 0.98 mGy a(-1). The above values of absorbed doses become very important, by concurrence of the circumstances, because they represent the zero background radiation level before the incidence of depleted uranium over former Yougoslav territory in the Kosovo region in the spring of 1999. These measured absorbed dose exposures have to be compared with corresponding absorbed dose rates from the natural sources, such as soil having an exposure of 18-93 nGy h(-1) (average 35 nGy h(-1)) according to the UNSCEAR 2000 Report. This investigation has been primarily done in order to check the impact of coal-fired power plants on the background radiation level in its vicinity. According to the experimental results, influence was confirmed both qualitatively and quantitatively.

journal_name

Radiat Prot Dosimetry

authors

Adrovic F,Prokić M,Ninković MM,Glisić R

doi

10.1093/rpd/nch401

keywords:

subject

Has Abstract

pub_date

2004-01-01 00:00:00

pages

439-42

issue

3

eissn

0144-8420

issn

1742-3406

pii

nch401

journal_volume

112

pub_type

杂志文章
  • A fast response and gamma-insensitive neutron detector based on parallel-plate avalanche counter.

    abstract::The use of the parallel-plate avalanche counter for slow-neutron counting is described. The choice of a suitable neutron converter is discussed on the basis of Monte Carlo simulation, and some experimental results are shown. Excellent gamma-insensitivity, high rate capability, possibility of construction in large sens...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncm462

    authors: Nakhostin M,Baba M,Itoga T,Oishi T,Unno Y,Kamada S,Okuji T

    更新日期:2008-01-01 00:00:00

  • Assessment of radiation doses to Australian participants in British nuclear tests.

    abstract::Between 1952 and 1957, the UK exploded a total of 12 nuclear devices in Australia, and also conducted about 600 'minor trials' that did not involve a nuclear explosion. Over 16 000 Australian servicemen and civilians were involved in the UK tests in Australia. This paper reports the estimation of doses that the Austra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp164

    authors: Crouch P,Robotham FR,Williams G,Wise K

    更新日期:2009-09-01 00:00:00

  • The response of a bonner sphere spectrometer to charged hadrons.

    abstract::Bonner sphere spectrometers (BSSs) are employed in neutron spectrometry and dosimetry since many years. Recent developments have seen the addition to a conventional BSS of one or more detectors (moderator plus thermal neutron counter) specifically designed to improve the overall response of the spectrometer to neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch187

    authors: Agosteo S,Dimovasili E,Fassò A,Silari M

    更新日期:2004-01-01 00:00:00

  • Dose trends in occupational radiation exposure in Europe results from the ESOREX project.

    abstract::The ESOREX project was initiated in 1997 by the EC DG TREN and it was executed by the BfS/Germany in close co-operation with the State Office for Nuclear Safety/Czech Republic). It consists of surveys on radiation monitoring and exposure carried out in the 30 European states. The study provides comparable descriptions...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl566

    authors: Frasch G,Petrová K

    更新日期:2007-01-01 00:00:00

  • Monte Carlo dosimetry for targeted irradiation of individual cells using a microbeam facility.

    abstract::Microbeam facilities provide a unique opportunity to investigate the effects of ionising radiation on living biological cells with a precise control of the delivered dose. This paper describes dosimetry calculations performed at the single-cell level in the microbeam irradiation facility available at the Centre d'Etud...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp003

    authors: Incerti S,Seznec H,Simon M,Barberet P,Habchi C,Moretto P

    更新日期:2009-01-01 00:00:00

  • PRUDENCE AND CONSERVATISM IN RADIATION PROTECTION: A CASE STUDY.

    abstract::Prudence is a cornerstone of radiation protection philosophy. However, whilst the concept is clearly valid at the level of principle, it is nonetheless necessary to ask 'How should prudence be applied in the context of various practical situations.' This is perhaps particularly important where exposures are low-within...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw310

    authors: Coates R

    更新日期:2017-04-01 00:00:00

  • A legally approved personal dosemeter for photon and beta radiation based on direct ion storage.

    abstract::The novel DIS-1 dosemeter developed by RADOS is based on ionisation chambers with so-called Direct Ion Storage (DIS). The dosemeter can measure Hp(10) and Hp(0.07) of photon and Hp(0.07) of beta irradiation. The characteristics of the commercially available DIS-1 dosemeter were studied at the Paul Scherrer Institute, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005984

    authors: Boschung M,Fiechtner A,Wernli C

    更新日期:2002-01-01 00:00:00

  • Occupational radiation exposure to norms in a gold mine.

    abstract::Preliminary studies have been conducted into the occupational radiation exposure to NORMS from surface and underground mining operations in a gold mine in the Ashanti Region of Ghana. A brief description of the methods and instrumentation is presented. The annual effective dose has been estimated to be 0.26 +/- 0.11 m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci300

    authors: Darko EO,Tetteh GK,Akaho EH

    更新日期:2005-01-01 00:00:00

  • Broadband Direct UVA irradiance measurement for clear skies evaluated using a smartphone.

    abstract::UVA wavelengths (320-400 nm) have been implicated in recent studies to contribute to melanoma induction and skin photoaging in humans and damage to plants. The use of smartphones in UVA observations is a way to supplement measurements made by traditional radiometric and spectroradiometric technology. Although the smar...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu344

    authors: Igoe D,Parisi AV

    更新日期:2015-12-01 00:00:00

  • Population dose in the vicinity of closed Hungarian uranium mine.

    abstract::In order to determine the exposure to natural sources of radiation for people in the vicinity of remediated Hungarian uranium mine regional surveys were carried out. The surveys evaluated indoor radon concentrations and outdoor and indoor external gamma dose rates. Radon concentration has been measured with nuclear et...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci363

    authors: Gorjánácz Z,Várhegyi A,Kovács T,Somlai J

    更新日期:2006-01-01 00:00:00

  • RADIOLOGICAL HAZARD INDICES OF GRANITIC ROCKS USED FOR THE CONSTRUCTION OF BUILDINGS FROM NUBA MOUNTAINS SUDAN.

    abstract::This study was conducted to assess the level of radioactivity and the radiation hazards associated with granite rocks used for construction of buildings. The measurement of radioactivity content of the rock samples was performed with gamma-spectrometry equipped with Nal (TI) detector. From the results obtained in this...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx295

    authors: Fadol N,Idriss H,Salih I,Ragab NA,Osman S,Sam AK

    更新日期:2018-06-01 00:00:00

  • Looking into future: challenges in radiation protection in medicine.

    abstract::Radiation protection in medicine is becoming more and more important with increasing wider use of X-rays, documentation of effects besides the potential for long-term carcinogenic effects. With computed tomography (CT) likely to become sub-mSv in coming years, positron emission tomography (PET), single photon emission...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv071

    authors: Rehani MM

    更新日期:2015-07-01 00:00:00

  • Intercomparison of patient CTDI surveys in three countries.

    abstract::The results of large-scale computed tomography (CT) patient dose surveys from the USA, UK and Germany undertaken during the period 1999-2001 were reviewed. The mean values for volume-weighted CT dose index (CTDI(vol)) and dose length product (DLP) were extracted. For head CT examinations, the reported values for the t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs123

    authors: Martin CJ,Huda W

    更新日期:2013-01-01 00:00:00

  • UNATTACHED 212PB FRACTION IN THE WORKER'S BREATHING ZONE AT HIGH THORON CONCENTRATIONS.

    abstract::Classical aerosol physics predicts that it is impossible to observe noticeable values of the unattached fraction of decay products of thoron at typical concentrations of aerosol particles. The experimental data have shown that the unattached fraction of the thoron decay products in a monazite storage facility is in th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa154

    authors: Zhukovsky M,Vasyanovich M,Onishchenko A

    更新日期:2020-11-27 00:00:00

  • RESULTS AND DISCUSSION ON JAPANESE PUBLIC OPINION SURVEYS (2006-17) ABOUT NUCLEAR AND RADIATION APPLICATIONS.

    abstract::Public opinion on the application of nuclear technology and radiation could change when a nuclear related event occurs. Japan Atomic Energy Relations Organization has tracked its variation through a nationwide opinion survey in Japan by almost the same way every year since FY 2006. We can identify a continuous long-te...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz127

    authors: Iimoto T,Takashima R,Kimura H,Kawakami K,Endo H,Yasuda H,Nagata N,Sakai N,Kawasaki Y,Funakoshi M

    更新日期:2019-10-01 00:00:00

  • Entrance surface, organ and effective doses for some of the patients undergoing different types of X ray procedures in Bangladesh.

    abstract::Entrance surface doses (ESDs) were measured for the most common types of X ray procedures, such as chest PA, lumber spine AP, lumber spine lateral, skull AP, skull lateral and pelvis AP in four major hospitals of Dhaka, the capital city of Bangladesh. Organ/tissue doses for 29 organs/tissues and effective doses for th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006549

    authors: Begum Z

    更新日期:2001-01-01 00:00:00

  • Thermoluminescence properties of LiMgF3 doped with Ce, Er and Dy.

    abstract::The main dosimetric properties are reported of a new perovskite, LiMgF3, doped with Ce, Er and Dy impurities. An annealing temperature of 400 degrees C for one hour is necessary to erase any previous signal and to stabilise its sensitivity. A readout up to 450 degrees C gives the same result. The glow curve structure ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005858

    authors: Kitis G,Furetta C,Sanipoli C

    更新日期:2002-01-01 00:00:00

  • Digital dual-parameter data acquisition for SP2 hydrogen-filled proportional counters.

    abstract::Hydrogen-filled proportional counters perform well as neutron spectrometers in the energy region from a few tens of keV up to ∼1.5 MeV. Unfortunately, gamma rays also generate signals in these detectors. It is possible in principle to distinguish the two types of event via the rise time of their respective signal puls...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct262

    authors: Hawkes NP,Roberts NJ

    更新日期:2014-10-01 00:00:00

  • The effect of dose heterogeneity on radiation risk in medical imaging.

    abstract::The current estimations of risk associated with medical imaging procedures rely on assessing the organ dose via direct measurements or simulation. The dose to each organ is assumed to be homogeneous. To take into account the differences in radiation sensitivities, the mean organ doses are weighted by a corresponding t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs275

    authors: Samei E,Li X,Chen B,Reiman R

    更新日期:2013-06-01 00:00:00

  • Considerations and preliminary design of patient exposure registry.

    abstract::To aid in protecting patients from unnecessary exposures and to reduce radiation burdens to the public, a system for tracking a patient's medical exposure history and related radiation doses would be a useful tool. A patient-centred exposure registry, the Patient Exposure Registry (PER), is a mechanism that provides t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq280

    authors: Chen J,Moir D,Cornett J

    更新日期:2010-12-01 00:00:00

  • Accreditation in radiation protection for cardiologists and interventionalists.

    abstract::Training in radiation protection is widely recognised as one of the basic components of optimisation programmes for medical exposures. Occupational and patient radiation risks in interventional radiology can be quite high and international bodies have shown concern on this item. Following recommendations of the Intern...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci730

    authors: Vano E,Gonzalez L

    更新日期:2005-01-01 00:00:00

  • Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter.

    abstract::Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 microm thick CVD diamon...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci667

    authors: Preciado-Flores S,Schreck M,Meléndrez R,Chernov V,Bernal R,Cruz-Vázquez C,Cruz-Zaragoza E,Barboza-Flores M

    更新日期:2006-01-01 00:00:00

  • Review of Bayesian statistical analysis methods for cytogenetic radiation biodosimetry, with a practical example.

    abstract::Classical methods of assessing the uncertainty associated with radiation doses estimated using cytogenetic techniques are now extremely well defined. However, several authors have suggested that a Bayesian approach to uncertainty estimation may be more suitable for cytogenetic data, which are inherently stochastic in ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/nct301

    authors: Ainsbury EA,Vinnikov VA,Puig P,Higueras M,Maznyk NA,Lloyd DC,Rothkamm K

    更新日期:2014-12-01 00:00:00

  • COMPARISON OF DIFFERENT TECHNIQUES FOR EVALUATION OF DOSE DISTRIBUTIONS IN RADIOTHERAPY USING RADIOCHROMIC EBT3 FILMS.

    abstract::In radiotherapy, radiochromic films can be used for verification of delivery of dose distributions calculated by treatment planning systems. The main objective of this work was to compare three different techniques for evaluation of dose distributions for prostate cancer treatment plans using radiochromic EBT3 films. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz231

    authors: Dufek V,Horakova I,Koniarova I

    更新日期:2019-12-31 00:00:00

  • Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses.

    abstract::The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdome...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu321

    authors: Suliman II,Khamis HM,Ombada TH,Alzimami K,Alkhorayef M,Sulieman A

    更新日期:2015-12-01 00:00:00

  • A high-sensitivity method for the measurement of 222Rn based on liquid scintillation counting of polycarbonate powder.

    abstract::This work describes a technique for the measurement of 222Rn by absorption in polycarbonate (PC) powder and liquid scintillation counting (LSC). The work is an improvement of the recently proposed method for 222Rn measurements by LSC of exposed PC grains. It is demonstrated that the use of PC powder as a 222Rn sampler...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu075

    authors: Mitev K,Georgiev S,Pressyanov D,Dimitrova I,Zhivkova V,Boshkova T

    更新日期:2014-07-01 00:00:00

  • SOIL 222Rn CONCENTRATION, CO2 AND CH4 FLUX MEASUREMENTS AROUND THE JWALAMUKHI AREA OF NORTH-WEST HIMALAYAS, INDIA.

    abstract::Soil 222Rn concentration, CO2 and CH4 flux measurements were conducted around the Jwalamukhi area of North-West Himalayas, India. During this study, around 37 soil gas points and flux measurements were taken with the aim to assure the suitability of this method in the study of fault zones. For this purpose, RAD 7 (Dur...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw071

    authors: Kumar A,Walia V,Yang TF,Fu CC,Singh S,Bajwa BS,Arora V

    更新日期:2016-10-01 00:00:00

  • Novel developments in the MOSFET dosemeter for neutron dosimetry applications.

    abstract::The feasibility of large-geometry Metal Oxide Semiconductor Field Effect Transistor (MOSFET) devices has been assessed for both active and passive neutron dosimetry and use in radiotherapy environments. Neutron sensitivity has been enhanced with the use of polymeric cement surrounding the gate region. Neutron activati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch202

    authors: Price RA,Benson C,Joyce MJ,Kestell DJ,Silvie J

    更新日期:2004-01-01 00:00:00

  • Performance of pellets and composites of natural colourless topaz as radiation dosemeters.

    abstract::The aim of the present work is to investigate the possibility of using the properties of the thermoluminescent emission (TL) of Brazilian natural topaz for dosimetric applications. Topaz is an aluminium fluorsilicate with general composition of Al2(SiO4)(F,OH)2 found with relative abundance in Brazil and in other part...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005902

    authors: Souza DN,Lima JF,Valerio ME,Caldas LV

    更新日期:2002-01-01 00:00:00

  • Defect complexes in Re3+-doped magnesium sulphate phosphors.

    abstract::A series of magnesium sulphate phosphors MgSO4:RE3+,X ( RE = Dy, Tm, Eu and X = P, Mn) have been prepared and studied. Based on the experimental results of thermoluminescence (TL) emission spectra and dose responses studies, it is proposed that in these phosphors large defect complexes are formed, which include intrin...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci680

    authors: Luo DL,Tang Q,Zhang CX

    更新日期:2006-01-01 00:00:00