Review of Bayesian statistical analysis methods for cytogenetic radiation biodosimetry, with a practical example.

Abstract:

:Classical methods of assessing the uncertainty associated with radiation doses estimated using cytogenetic techniques are now extremely well defined. However, several authors have suggested that a Bayesian approach to uncertainty estimation may be more suitable for cytogenetic data, which are inherently stochastic in nature. The Bayesian analysis framework focuses on identification of probability distributions (for yield of aberrations or estimated dose), which also means that uncertainty is an intrinsic part of the analysis, rather than an 'afterthought'. In this paper Bayesian, as well as some more advanced classical, data analysis methods for radiation cytogenetics are reviewed that have been proposed in the literature. A practical overview of Bayesian cytogenetic dose estimation is also presented, with worked examples from the literature.

journal_name

Radiat Prot Dosimetry

authors

Ainsbury EA,Vinnikov VA,Puig P,Higueras M,Maznyk NA,Lloyd DC,Rothkamm K

doi

10.1093/rpd/nct301

subject

Has Abstract

pub_date

2014-12-01 00:00:00

pages

185-96

issue

3

eissn

0144-8420

issn

1742-3406

pii

nct301

journal_volume

162

pub_type

杂志文章,评审
  • Indoor radon measurements in Turkey dwellings.

    abstract::In this work, indoor radon radioactivity concentration levels have been measured in dwellings of Turkey within the frame of the National Radon Monitoring Programme. The (222)Rn concentrations were measured with time-integrating passive nuclear etched track detectors in 7293 dwellings in 153 residential units of 81 pro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu329

    authors: Celebi N,Ataksor B,Taskın H,Bingoldag NA

    更新日期:2015-12-01 00:00:00

  • A recoil-proton spectrometer based on a p-i-n diode implementing pulse-shape discrimination.

    abstract::A recoil-proton spectrometer was created by coupling a p-i-n diode with a polyethylene converter. The maximum detectable energy, imposed by the thickness of the totally depleted layer, is approximately 6 MeV. The minimum detectable energy is limited by the contribution of secondary electrons generated by photons in th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch237

    authors: Agosteo S,D'Angelo G,Fazzi A,Foglio Para A,Pola A,Ventura L,Zotto P

    更新日期:2004-01-01 00:00:00

  • DOSE AREA PRODUCT VALUES OF FLUOROSCOPICALLY GUIDED PAIN MANAGEMENT PROCEDURES: COMPARISON OF A BELGIAN TEACHING HOSPITAL WITH NATIONAL DIAGNOSTIC REFERENCE LEVELS.

    abstract::In 2011, national diagnostic reference levels (DRLs) were proposed for pain management fluoroscopic procedures in Belgium. The primary goal of this work is to compare the dose area product values (DAP) recorded at the Saint-Luc University Hospital to these DRLs. From 2012 to 2015, 7664 interventional pain management p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx271

    authors: Hustinx N,Steyaert A,le Polain de Waroux B,Forget P

    更新日期:2018-05-01 00:00:00

  • FEASIBILITY STUDY FOR IDENTIFICATION OF STATIC AND DYNAMIC EXPOSURE USING CCD IMAGING TECHNIQUE FOR Caso4:Dy TL DOSEMETERS.

    abstract::The occupational exposure incurred by the radiation workers due to the external radiation is estimated using personal dosemeter placed on the human body during the monitoring period. In certain situations, it is required to determine whether the dosemeter alone was exposed accidentally/intentionally in radiation field...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx011

    authors: Srivastava K,Soin S,Sapra BK,Ratna P,Datta D

    更新日期:2017-11-01 00:00:00

  • ESTE-DECISION SUPPORT SYSTEM FOR NUCLEAR AND RADIOLOGICAL ACCIDENTS.

    abstract::Described are functions, models and approaches of software tool Emergency Source Term code (ESTE), which is decision support system for crisis staff in case of nuclear or radiological accidents. The first task of ESTE in emergency situation at nuclear facility is to evaluate state of reactor core or state of fuel in s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz226

    authors: Fojcíková E,Lipták Ľ,Krpelanová M,Chylý M,Čarný P

    更新日期:2019-12-31 00:00:00

  • The effect of Mg, Cu and P impurities on dose response of LiF:Mg,Cu,P phosphors: simulation versus experiments.

    abstract::In this research, the effect of magnesium (Mg), copper (Cu) and phosphorus (P) impurities on dosimetry response of LiF:Mg,Cu,P phosphors is studied experimentally and by the simulation procedure. In the experimental procedure, LiF:Mg,Cu,P phosphors in the powder form were synthesised by chemical co-precipitation metho...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv002

    authors: Mohammadi K,Khayat O,Afarideh H

    更新日期:2016-01-01 00:00:00

  • Transfer of alkaline earth elements in mothers' milk and doses from 45Ca, 90Sr and 226Ra.

    abstract::An international programme of work is currently under way to develop methods for calculating doses to infants from ingestion of radionuclides present in mothers' milk. This paper considers the special case of the alkaline earth elements. Models have been developed for 45Ca, 90Sr and 226Ra and the sensitivity of result...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006239

    authors: Smith TJ,Phipps AW,Fell TP,Harrison JD

    更新日期:2003-01-01 00:00:00

  • Excess radiation absorbed doses from non-optimised radioiodine treatment of hyperthyroidism.

    abstract::Radioiodine therapy is often the method of choice for treatment of hyperthyroidism because it is considered safe, is relatively inexpensive, and is convenient for the patient and except for occasional hypothyroidism, almost without side effects. Even though radioiodine treatment has been performed for over 50 years, t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch013

    authors: Jönsson H,Mattsson S

    更新日期:2004-01-01 00:00:00

  • Natural radioactivity study in soil samples of South Konkan, Maharashtra, India.

    abstract::This study assesses the level of natural radioactivity due to radionuclides, ²³⁸U, ²³²Th and ⁴⁰K, in 50 soil samples collected from South Konkan, Maharashtra, India. The mean activity concentrations of ²³⁸U, ²³²Th and ⁴⁰K are 44.97 ± 1.22 Bq kg⁻¹, 59.70 ± 2.17 Bq kg⁻¹ and 217.51 ± 8.75 Bq kg⁻¹, respectively, measured ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct131

    authors: Dhawal SJ,Phadatare MR,Thorat ND,Kulkarni GS,Pawar SH

    更新日期:2013-12-01 00:00:00

  • Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote afterloader.

    abstract::In support of the effort to begin high-dose rate 252Cf brachytherapy treatments at Tufts-New England Medical Center, the shielding capabilities of a clinical accelerator vault against the neutron and photon emissions from a 1.124 mg 252Cf source were examined. Outside the clinical accelerator vault, the fast neutron d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch473

    authors: Melhus CS,Rivard MJ,Kurkomelis J,Liddle CB,Massé FX

    更新日期:2005-01-01 00:00:00

  • Radiation protection culture: a global challenge.

    abstract::The central motto 'Radiation Protection Culture-A Global Challenge' of the fourth European IRPA Congress is discussed on the basis of the IRPA Guiding Principles Establishing a Radiation Protection Culture and the contributions presented in the plenary sessions of the conference. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu325

    authors: Michel R,Henrichs K,Wernli C

    更新日期:2015-04-01 00:00:00

  • Determination of 137Cs and 60Co pollution in the area of the Laguna Verde Nuclear Power Plant, Mexico.

    abstract::The project 'Radiological Analysis of Environmental Samples in the Gulf of Mexico and the coast of Quintana Roo', had the aim of identifying and quantifying anthropogenic radionuclides in environmental samples consisting of silt, sand and sea water. This paper presents the results of the radiological analysis of these...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv250

    authors: Salas Mar B

    更新日期:2015-11-01 00:00:00

  • Determination of a neutron source position in an unknown homogeneous medium; the 2D case.

    abstract::The localisation of an unknown neutron source in various bulky homogeneous media was studied. For the planar case two (3)He detectors on the opposite faces of a box were used. It is shown that the location of a single small neutron emitting source in a large box can be found to a better than 7% by using two neutron de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm048

    authors: Dubinski S,Presler O,Alfassi ZB

    更新日期:2007-01-01 00:00:00

  • Different versions of the right answer: the importance of measurement uncertainty in radiation dosimetry.

    abstract::The performance of radiation dosemeters that are issued by approved individual monitoring services generally meet international standards, with typical results within a few tens of per cent of the reference value. Experienced dosimetry practitioners will understand the uncertainties and treat monitoring results with d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq298

    authors: Gilvin P,McWhan A

    更新日期:2011-03-01 00:00:00

  • RADIATION DOSE FROM DENTAL RADIOGRAPHY IN INDONESIA: A FIVE-YEAR SURVEY.

    abstract::Dose metrics on intraoral and panoramic dental radiography were analyzed to preliminarily indicate dose trend of dental radiology equipment in Indonesia. Measurements were performed in 71 healthcare institutions involving a total of 92 dental X-ray devices. Imaging modes are categorized into 'low dose' and 'high dose'...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncy123

    authors: Lubis LE,Bayuadi I,Bayhaqi YA,Ardiansyah F,Setiadi AR,Sugandi RD,Craig LA,Nasir A,Basith RA,Pawiro SA,Soejoko DS

    更新日期:2019-05-01 00:00:00

  • Emission rate estimation through data assimilation of gamma dose measurements in a Lagrangian atmospheric dispersion model.

    abstract::This paper presents an efficient algorithm for estimating the unknown emission rate of radionuclides in the atmosphere following a nuclear accident. The algorithm is based on assimilation of gamma dose rate measured data in a Lagrangian atmospheric dispersion model. Such models are used in the framework of nuclear eme...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq592

    authors: Tsiouri V,Kovalets I,Andronopoulos S,Bartzis JG

    更新日期:2012-01-01 00:00:00

  • Radon in earthquake prediction research.

    abstract::The observation of anomalies in the radon concentration in soil gas and ground water before earthquakes initiated systematic investigations on earthquake precursor phenomena. The question what is needed for a meaningful earthquake prediction as well as what types of precursory effects can be expected is shortly discus...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr229

    authors: Friedmann H

    更新日期:2012-04-01 00:00:00

  • Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses.

    abstract::The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdome...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu321

    authors: Suliman II,Khamis HM,Ombada TH,Alzimami K,Alkhorayef M,Sulieman A

    更新日期:2015-12-01 00:00:00

  • Contribution of indirect effects to clustered damage in DNA irradiated with protons.

    abstract::Protons are the dominant particles both in galactic cosmic rays and in solar particle events and, furthermore, proton irradiation becomes increasingly used in tumour treatment. It is believed that complex DNA damage is the determining factor for the consequent cellular response to radiation. DNA plasmid pBR322 was irr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv159

    authors: Pachnerová Brabcová K,Štěpán V,Karamitros M,Karabín M,Dostálek P,Incerti S,Davídková M,Sihver L

    更新日期:2015-09-01 00:00:00

  • High-Dose TL Dosimetry of Reactor Neutrons.

    abstract::Radiation dose was measured with set of TL dosimeters during checkout of neutron radiation hardness of the ORTEC preamplifier type 142A in the experiment at the MARIA nuclear reactor at the National Centre for Nuclear Research (NCBJ), Otwock-Świerk, Poland. Different types of LiF-based TL detectors have been used for ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx244

    authors: Obryk B,Malik K,Bilski P,Igielski A,Dankowski J,Kurowski A,Prokopowicz R,Pytel K

    更新日期:2018-08-01 00:00:00

  • ESTIMATION OF EXPOSURE DOSES FOR THE SAFE MANAGEMENT OF NORM WASTE DISPOSAL.

    abstract::Naturally occurring radioactive materials (NORM) wastes with different radiological characteristics are generated in several industries. The appropriate options for NORM waste management including disposal options should be discussed and established based on the act and regulation guidelines. Several studies calculate...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy041

    authors: Jeong J,Ko NY,Cho DK,Baik MH,Yoon KH

    更新日期:2018-11-01 00:00:00

  • A MULTI-ELEMENT THICK GAS ELECTRON MULTIPLIER-BASED MICRODOSEMETER FOR MEASUREMENT OF NEUTRONS DOSE-EQUIVALENT: A MONTE CARLO STUDY.

    abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx024

    authors: Moslehi A,Raisali G

    更新日期:2017-11-01 00:00:00

  • LEAD COMPOSITE VS. NONLEAD PROTECTIVE GARMENTS: WHICH ARE BETTER? A MULTIVENDOR COMPARISON.

    abstract::This study aims to provide more insight in attenuation characteristics and corresponding lead (Pb) equivalences of a broad range of commercially available lead composite and nonlead protective garments. Thirty garments of five manufacturers (listed as 0.25-0.35-0.50 mm Pb equivalent) were tested. Transmission values w...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw373

    authors: Peters SMB,Zweers D,de Lange F,Mourik JEM

    更新日期:2017-08-01 00:00:00

  • Looking into future: challenges in radiation protection in medicine.

    abstract::Radiation protection in medicine is becoming more and more important with increasing wider use of X-rays, documentation of effects besides the potential for long-term carcinogenic effects. With computed tomography (CT) likely to become sub-mSv in coming years, positron emission tomography (PET), single photon emission...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv071

    authors: Rehani MM

    更新日期:2015-07-01 00:00:00

  • NASA Space Radiation Transport Code Development Consortium.

    abstract::Recently, NASA established a consortium involving the University of Tennessee (lead institution), the University of Houston, Roanoke College and various government and national laboratories, to accelerate the development of a standard set of radiation transport computer codes for NASA human exploration applications. T...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci092

    authors: Townsend LW

    更新日期:2005-01-01 00:00:00

  • Energy dependence of W values of protons in water.

    abstract::The W values of protons in water vapour were measured for energies from 1 keV to 100 keV with uncertainties lower than 1%. To study the energy and phase dependence of W values, the W values of protons in water vapour and liquid water were calculated for energies from 0.1 keV and 10 MeV and then compared to the experim...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006798

    authors: Willems G,Back WY,Grosswendt B

    更新日期:2002-01-01 00:00:00

  • Comparison of results from quality control of physical parameters and results from clinical evaluation of mammographic images for the mammography screening facilities in Poland.

    abstract::The material for this study comprised control protocols from 248 mammography screening facilities, prepared by physicists employed at 16 Regional Coordinating Centres and the results from the clinical evaluation of mammographic images in 248 facilities in Poland. All mammograms were evaluated independently by three ex...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncr321

    authors: Fabiszewska E,Grabska I,Jankowska K,Wesolowska E,Bulski W

    更新日期:2011-09-01 00:00:00

  • Electron spin resonance evaluation of pure CaSO4 and as a phosphor doped with P and Dy.

    abstract::Polycrystalline CaSO4 powder, doped with different elements but mainly rare earths, is one of the most interesting thermoluminescent (TL) materials. Although many electron spin resonance (ESR) analyses have been reported for these materials few studies have been published about the potential of CaSO4 for ESR dosimetry...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006047

    authors: de Jesus EF,Rossi AM,Lopes RT

    更新日期:2002-01-01 00:00:00

  • Neutron spectra unfolding in Bonner spheres spectrometry using neural networks.

    abstract::The neural network method has been used for the unfolding of neutron spectra in neutron spectrometry by Bonner spheres. A back propagation algorithm was used for training of neural networks. 4 mm x 4 mm bare LiI (Eu) and in a polyethylene sphere set: 2, 3, 4, 5, 6, 7, 8, 10, 12, 18 inch diameter have been used for unf...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006158

    authors: Kardan MR,Setayeshi S,Koohi-Fayegh R,Ghiassi-Nejad M

    更新日期:2003-01-01 00:00:00

  • ESTIMATE OF UAE COMMERCIAL AIRCREW EFFECTIVE DOSES USING CARI-6, EPCARD AND SIEVERT CODES.

    abstract::The aim of this study is to calculate total cruising route effective doses using three commonly used algorithm codes CARI-6, EPCARD and SIEVERT. Further, the impact of flight cruising duration, altitude and latitude on the estimated effective doses will also be investigated. A total of 24 commercial UAE flight data we...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy280

    authors: Dalah EZ,Elmahdi HM,Al Humaidan KS,Semerjian L

    更新日期:2019-11-30 00:00:00