Abstract:
:Classical methods of assessing the uncertainty associated with radiation doses estimated using cytogenetic techniques are now extremely well defined. However, several authors have suggested that a Bayesian approach to uncertainty estimation may be more suitable for cytogenetic data, which are inherently stochastic in nature. The Bayesian analysis framework focuses on identification of probability distributions (for yield of aberrations or estimated dose), which also means that uncertainty is an intrinsic part of the analysis, rather than an 'afterthought'. In this paper Bayesian, as well as some more advanced classical, data analysis methods for radiation cytogenetics are reviewed that have been proposed in the literature. A practical overview of Bayesian cytogenetic dose estimation is also presented, with worked examples from the literature.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Ainsbury EA,Vinnikov VA,Puig P,Higueras M,Maznyk NA,Lloyd DC,Rothkamm Kdoi
10.1093/rpd/nct301subject
Has Abstractpub_date
2014-12-01 00:00:00pages
185-96issue
3eissn
0144-8420issn
1742-3406pii
nct301journal_volume
162pub_type
杂志文章,评审abstract::In this work, indoor radon radioactivity concentration levels have been measured in dwellings of Turkey within the frame of the National Radon Monitoring Programme. The (222)Rn concentrations were measured with time-integrating passive nuclear etched track detectors in 7293 dwellings in 153 residential units of 81 pro...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu329
更新日期:2015-12-01 00:00:00
abstract::A recoil-proton spectrometer was created by coupling a p-i-n diode with a polyethylene converter. The maximum detectable energy, imposed by the thickness of the totally depleted layer, is approximately 6 MeV. The minimum detectable energy is limited by the contribution of secondary electrons generated by photons in th...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch237
更新日期:2004-01-01 00:00:00
abstract::In 2011, national diagnostic reference levels (DRLs) were proposed for pain management fluoroscopic procedures in Belgium. The primary goal of this work is to compare the dose area product values (DAP) recorded at the Saint-Luc University Hospital to these DRLs. From 2012 to 2015, 7664 interventional pain management p...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx271
更新日期:2018-05-01 00:00:00
abstract::The occupational exposure incurred by the radiation workers due to the external radiation is estimated using personal dosemeter placed on the human body during the monitoring period. In certain situations, it is required to determine whether the dosemeter alone was exposed accidentally/intentionally in radiation field...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx011
更新日期:2017-11-01 00:00:00
abstract::Described are functions, models and approaches of software tool Emergency Source Term code (ESTE), which is decision support system for crisis staff in case of nuclear or radiological accidents. The first task of ESTE in emergency situation at nuclear facility is to evaluate state of reactor core or state of fuel in s...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz226
更新日期:2019-12-31 00:00:00
abstract::In this research, the effect of magnesium (Mg), copper (Cu) and phosphorus (P) impurities on dosimetry response of LiF:Mg,Cu,P phosphors is studied experimentally and by the simulation procedure. In the experimental procedure, LiF:Mg,Cu,P phosphors in the powder form were synthesised by chemical co-precipitation metho...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv002
更新日期:2016-01-01 00:00:00
abstract::An international programme of work is currently under way to develop methods for calculating doses to infants from ingestion of radionuclides present in mothers' milk. This paper considers the special case of the alkaline earth elements. Models have been developed for 45Ca, 90Sr and 226Ra and the sensitivity of result...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006239
更新日期:2003-01-01 00:00:00
abstract::Radioiodine therapy is often the method of choice for treatment of hyperthyroidism because it is considered safe, is relatively inexpensive, and is convenient for the patient and except for occasional hypothyroidism, almost without side effects. Even though radioiodine treatment has been performed for over 50 years, t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch013
更新日期:2004-01-01 00:00:00
abstract::This study assesses the level of natural radioactivity due to radionuclides, ²³⁸U, ²³²Th and ⁴⁰K, in 50 soil samples collected from South Konkan, Maharashtra, India. The mean activity concentrations of ²³⁸U, ²³²Th and ⁴⁰K are 44.97 ± 1.22 Bq kg⁻¹, 59.70 ± 2.17 Bq kg⁻¹ and 217.51 ± 8.75 Bq kg⁻¹, respectively, measured ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct131
更新日期:2013-12-01 00:00:00
abstract::In support of the effort to begin high-dose rate 252Cf brachytherapy treatments at Tufts-New England Medical Center, the shielding capabilities of a clinical accelerator vault against the neutron and photon emissions from a 1.124 mg 252Cf source were examined. Outside the clinical accelerator vault, the fast neutron d...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch473
更新日期:2005-01-01 00:00:00
abstract::The central motto 'Radiation Protection Culture-A Global Challenge' of the fourth European IRPA Congress is discussed on the basis of the IRPA Guiding Principles Establishing a Radiation Protection Culture and the contributions presented in the plenary sessions of the conference. ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu325
更新日期:2015-04-01 00:00:00
abstract::The project 'Radiological Analysis of Environmental Samples in the Gulf of Mexico and the coast of Quintana Roo', had the aim of identifying and quantifying anthropogenic radionuclides in environmental samples consisting of silt, sand and sea water. This paper presents the results of the radiological analysis of these...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv250
更新日期:2015-11-01 00:00:00
abstract::The localisation of an unknown neutron source in various bulky homogeneous media was studied. For the planar case two (3)He detectors on the opposite faces of a box were used. It is shown that the location of a single small neutron emitting source in a large box can be found to a better than 7% by using two neutron de...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm048
更新日期:2007-01-01 00:00:00
abstract::The performance of radiation dosemeters that are issued by approved individual monitoring services generally meet international standards, with typical results within a few tens of per cent of the reference value. Experienced dosimetry practitioners will understand the uncertainties and treat monitoring results with d...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq298
更新日期:2011-03-01 00:00:00
abstract::Dose metrics on intraoral and panoramic dental radiography were analyzed to preliminarily indicate dose trend of dental radiology equipment in Indonesia. Measurements were performed in 71 healthcare institutions involving a total of 92 dental X-ray devices. Imaging modes are categorized into 'low dose' and 'high dose'...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,多中心研究
doi:10.1093/rpd/ncy123
更新日期:2019-05-01 00:00:00
abstract::This paper presents an efficient algorithm for estimating the unknown emission rate of radionuclides in the atmosphere following a nuclear accident. The algorithm is based on assimilation of gamma dose rate measured data in a Lagrangian atmospheric dispersion model. Such models are used in the framework of nuclear eme...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq592
更新日期:2012-01-01 00:00:00
abstract::The observation of anomalies in the radon concentration in soil gas and ground water before earthquakes initiated systematic investigations on earthquake precursor phenomena. The question what is needed for a meaningful earthquake prediction as well as what types of precursory effects can be expected is shortly discus...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr229
更新日期:2012-04-01 00:00:00
abstract::The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdome...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu321
更新日期:2015-12-01 00:00:00
abstract::Protons are the dominant particles both in galactic cosmic rays and in solar particle events and, furthermore, proton irradiation becomes increasingly used in tumour treatment. It is believed that complex DNA damage is the determining factor for the consequent cellular response to radiation. DNA plasmid pBR322 was irr...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv159
更新日期:2015-09-01 00:00:00
abstract::Radiation dose was measured with set of TL dosimeters during checkout of neutron radiation hardness of the ORTEC preamplifier type 142A in the experiment at the MARIA nuclear reactor at the National Centre for Nuclear Research (NCBJ), Otwock-Świerk, Poland. Different types of LiF-based TL detectors have been used for ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx244
更新日期:2018-08-01 00:00:00
abstract::Naturally occurring radioactive materials (NORM) wastes with different radiological characteristics are generated in several industries. The appropriate options for NORM waste management including disposal options should be discussed and established based on the act and regulation guidelines. Several studies calculate...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy041
更新日期:2018-11-01 00:00:00
abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx024
更新日期:2017-11-01 00:00:00
abstract::This study aims to provide more insight in attenuation characteristics and corresponding lead (Pb) equivalences of a broad range of commercially available lead composite and nonlead protective garments. Thirty garments of five manufacturers (listed as 0.25-0.35-0.50 mm Pb equivalent) were tested. Transmission values w...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw373
更新日期:2017-08-01 00:00:00
abstract::Radiation protection in medicine is becoming more and more important with increasing wider use of X-rays, documentation of effects besides the potential for long-term carcinogenic effects. With computed tomography (CT) likely to become sub-mSv in coming years, positron emission tomography (PET), single photon emission...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv071
更新日期:2015-07-01 00:00:00
abstract::Recently, NASA established a consortium involving the University of Tennessee (lead institution), the University of Houston, Roanoke College and various government and national laboratories, to accelerate the development of a standard set of radiation transport computer codes for NASA human exploration applications. T...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci092
更新日期:2005-01-01 00:00:00
abstract::The W values of protons in water vapour were measured for energies from 1 keV to 100 keV with uncertainties lower than 1%. To study the energy and phase dependence of W values, the W values of protons in water vapour and liquid water were calculated for energies from 0.1 keV and 10 MeV and then compared to the experim...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006798
更新日期:2002-01-01 00:00:00
abstract::The material for this study comprised control protocols from 248 mammography screening facilities, prepared by physicists employed at 16 Regional Coordinating Centres and the results from the clinical evaluation of mammographic images in 248 facilities in Poland. All mammograms were evaluated independently by three ex...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,多中心研究
doi:10.1093/rpd/ncr321
更新日期:2011-09-01 00:00:00
abstract::Polycrystalline CaSO4 powder, doped with different elements but mainly rare earths, is one of the most interesting thermoluminescent (TL) materials. Although many electron spin resonance (ESR) analyses have been reported for these materials few studies have been published about the potential of CaSO4 for ESR dosimetry...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006047
更新日期:2002-01-01 00:00:00
abstract::The neural network method has been used for the unfolding of neutron spectra in neutron spectrometry by Bonner spheres. A back propagation algorithm was used for training of neural networks. 4 mm x 4 mm bare LiI (Eu) and in a polyethylene sphere set: 2, 3, 4, 5, 6, 7, 8, 10, 12, 18 inch diameter have been used for unf...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006158
更新日期:2003-01-01 00:00:00
abstract::The aim of this study is to calculate total cruising route effective doses using three commonly used algorithm codes CARI-6, EPCARD and SIEVERT. Further, the impact of flight cruising duration, altitude and latitude on the estimated effective doses will also be investigated. A total of 24 commercial UAE flight data we...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy280
更新日期:2019-11-30 00:00:00