Abstract:
:Polycrystalline CaSO4 powder, doped with different elements but mainly rare earths, is one of the most interesting thermoluminescent (TL) materials. Although many electron spin resonance (ESR) analyses have been reported for these materials few studies have been published about the potential of CaSO4 for ESR dosimetry; almost all studies used CaSO4:Dy with a very low Dy concentration as the material for TL measurements. Pure CaSO4 from Merck was used to prepare CaSO4:Dy and CaSO4:P:Dy with different Dy concentrations. Samples were annealed at 600 degrees C for 1 h before irradiation in a Gammacell 220 irradiator with a 60Co gamma source at a dose rate of 100 Gy x min(-1). The ESR spectra of the pure CaSO4 and CaSO4 doped with P and Dy show the lines usually observed with these types of material, with the factor g around 2.036 and an intense line at g = 2.0011 found only in the pure material. This line, probably an axial SO4-, grows linearly with absorbed dose until 1.0 kGy and shows good stability with time. The line should be stabilized by matrix impurities because it can be removed by a simple treatment with hot sulphuric acid.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
de Jesus EF,Rossi AM,Lopes RTdoi
10.1093/oxfordjournals.rpd.a006047keywords:
subject
Has Abstractpub_date
2002-01-01 00:00:00pages
553-6issue
1-4eissn
0144-8420issn
1742-3406journal_volume
101pub_type
杂志文章abstract::For the calibration of personal dosemeters in terms of H(p)(10), the ISO water slab phantom shall be used. The irradiation geometry must be chosen such that the field diameter at the phantom front surface is large enough to irradiate the phantom completely and, in addition, homogeneously. However, in practice it is no...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq036
更新日期:2010-06-01 00:00:00
abstract::Since December 2006, approximately 3800 clinical chest tomosynthesis examinations have been performed at our department at Sahlgrenska University Hospital. A subset of the examinations has been included in studies of the detectability of pulmonary nodules, using computed tomography (CT) as the gold standard. Visibilit...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq059
更新日期:2010-04-01 00:00:00
abstract::Lignite burning is one of the sources of technologically enhanced exposure to humans from natural radionuclides. In the preliminary study, part of the survey, the activity concentrations of (226)Ra, (232)Th and (40)K in 112 samples of feed lignites from seven lignite-fired power plants in Western Anatolia (Seyitömer, ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq210
更新日期:2010-12-01 00:00:00
abstract::In the present paper, we report the indigenous development of a neutron-sensitive thermoluminescent dosemeter (TLD) based on CaSO4:Dy Teflon TL disc. The study includes indigenous development of a neutron dosemeter and its response in terms of operational quantity to different energies of neutrons under various irradi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp019
更新日期:2009-01-01 00:00:00
abstract::The activity size distribution of the Equilibrium-Equivalent Concentration (EER) of 222Rn is one of the most important parameters for the estimation of radiation dose by inhalation of radon decay products. A series of measurements of the EER activity size distribution were performed by the screen diffusion battery in ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx157
更新日期:2017-11-01 00:00:00
abstract::The aim of this work was to experimentally compare the contrast improvement factors (CIFs) of a newly developed software-based scatter correction to the CIFs achieved by an antiscatter grid. To this end, three aluminium discs were placed in the lung, the retrocardial and the abdominal areas of a thorax phantom, and di...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv432
更新日期:2016-06-01 00:00:00
abstract::A new official albedo dosemeter based on thermoluminescent detectors has been introduced in 2015 by the individual monitoring service of the Helmholtz Zentrum München for monitoring persons who are exposed occupationally against photon and neutron radiation. To enhance the sensitivity for fast neutrons, a new badge wi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv406
更新日期:2016-09-01 00:00:00
abstract::The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminesce...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw100
更新日期:2017-04-20 00:00:00
abstract::The entrance surface dose (ESD) (skin dose) and its variation due to overlapping radiation fields at mammography have been experimentally investigated on patients during two-view mammography screening examinations of both breasts and on phantoms of silicon gel. Measurements were done using multiple thermoluminescence ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq077
更新日期:2010-04-01 00:00:00
abstract::The study of spatial distribution of the indoor radon has assumed in the last years a lot of interest. The geostatistical techniques turn out to be particularly promising. The present work presents the results of a study where around 4000 indoor radon data from Veneto, Friuli Venezia-Giulia and Alto Adige, collected d...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp252
更新日期:2009-12-01 00:00:00
abstract::To test the blood tritium level as an estimate of free water tritium (FWT) and organically bound tritium (OBT) in human soft tissues, a tritiated amino acid mixture (TAA) and tritiated water (HTO) were injected or orally administered to mice. Relatively high tritium retention in the blood was found after TAA injection...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006272
更新日期:2003-01-01 00:00:00
abstract::Comparative studies on the translocation and retention of intramuscularly (i.m.) injected thorium nitrate (234Th 46 ng + 232Th 5 microg per rat) in solutions of citrate, CaDTPA or citrate + CaDTPA in rats have been conducted. Results showed that only thorium in mixed-ligand solution was entirely translocated from the ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006294
更新日期:2003-01-01 00:00:00
abstract::Digital breast tomosynthesis is a new three-dimensional (3D) breast-imaging modality that produces images of cross-sectional planes parallel to the detector plane from a limited number of X-ray projections over a limited angular range. Several technical and clinical parameters have not yet been completely optimised. S...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq084
更新日期:2010-04-01 00:00:00
abstract::Gadolinium is a competent neutron conversion material for neutron detection due to its extremely high neutron capture cross section. It differs from the other neutron reactive materials by emitting large amounts of low-energy electrons for the consequent signal generation in a detector. Such low-energy electrons, thou...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs031
更新日期:2012-09-01 00:00:00
abstract::The use of Monte Carlo track structure is a choice method in biophysical modelling and calculations. To precisely model 3D and 4D tracks, the cross section for the ionisation by an incoming ion, double differential in the outgoing electron energy and angle, is required. However, the double differential cross section c...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq397
更新日期:2011-02-01 00:00:00
abstract::A newly developed thermoluminescence dosemeter system is presented that is suitable for application in fields where personal monitoring of a large number of users is required. The system presented here is intended to be used as the upcoming main dosemeter for whole body dosimetry at the dosimetry service of the MPA NR...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv478
更新日期:2016-09-01 00:00:00
abstract::Absorbed dose and average linear energy transfer (LET) were assessed by means of (7)LiF:Mg,Ti (TLD-700) thermoluminescent (TL) detectors for different panels on-board the Russian Segment of the International Space Station in the timeframe between March and November 2002 (233 d). A technique is presented to correct the...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci566
更新日期:2006-01-01 00:00:00
abstract::The radiation dose to workers at nuclear power stations (NPSs) in Japan was drastically reduced between the late-1970s and the early-1990s by continuous dose-reduction programmes. The total collective dose of radiation workers in FY 2008 was 84.04 person Sv, while the average collective dose was 1.5 person Sv per reac...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr185
更新日期:2011-07-01 00:00:00
abstract::A Japanese voxel phantom in upright posture, JM2, has been developed on the basis of CT images of a healthy Japanese adult male. Body characteristics of JM2 were compared with those of the supine voxel phantom, JM, previously developed using CT images of the same person. Differences were found in the shapes of the spi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm272
更新日期:2007-01-01 00:00:00
abstract::Because the doses received on-board aeroplanes are now monitored to fulfil legal requirements in some countries, including the European Community, the models to calculate doses received during solar events have left their purely academic status to become a part of operational systems as well. The present work consider...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci356
更新日期:2006-01-01 00:00:00
abstract::Although numerous models have been developed for occupational and medical internal dosimetry, they may not be applicable to an accident situation. Published dose coefficients relate effective dose to intake, but if acute deterministic effects are possible, effective dose is not a useful parameter. Consequently, dose r...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006250
更新日期:2003-01-01 00:00:00
abstract::Production of double strand breaks (DSBs) and double-stranded DNA fragments after irradiation with high energy nitrogen ions was simulated with stochastic track generation and a high-order chromatin structure (HOCS) model representing a segment of interphase chromosome. The non-random distribution of DNA fragments is ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006748
更新日期:2002-01-01 00:00:00
abstract::In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiati...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu315
更新日期:2015-04-01 00:00:00
abstract::The technique of alpha spectrometry is used to detect alpha particles and to determine their energy. In this way the technique is able to provide simultaneously quantitative information (i.e. the activity) and qualitative information (the identity) on any radionuclide that emits an alpha particle. The longer-lived nat...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006646
更新日期:2001-01-01 00:00:00
abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx024
更新日期:2017-11-01 00:00:00
abstract::The goal of this study was to compare dose estimates from electron paramagnetic resonance (EPR) dosimetry with teeth and cytogenetic dosimetry with blood lymphocytes for 30 victims of radiation accidents. The whole-body exposures estimated by tooth enamel EPR dosimetry were ranging from 0.01 to 9.3 Gy. Study group com...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu203
更新日期:2015-03-01 00:00:00
abstract::In the light of a growing awareness of the risks of inducing skin injuries as a consequence of fluoroscopically guided interventional procedures (FGIPs), this paper reports measurements of ESDs made during the period August 1998 to June 1999 on 137 patients undergoing cardiac, neurological and general FGIPs in the Sou...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006486
更新日期:2001-01-01 00:00:00
abstract::Monitoring of radon in underground mines is important in order to assess the radiological hazards to occupational workers. Radon concentration levels in three underground lignite mines (Tunçbilek, Omerler and Eynez) of Turkey were obtained in this study. For this reason, atmospheric radon level measurements were carri...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp179
更新日期:2010-01-01 00:00:00
abstract::The radon content in groundwater sources depends on the radium concentration in the rock of the aquifer. Radon was measured in water in many parts of the world, mostly for the risk assessment due to consumption of drinking water. The exposure to radon through drinking water is largely by inhalation and ingestion. Airb...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs186
更新日期:2012-11-01 00:00:00
abstract::In the Gastein valley, numerous facilities use radon for the treatment of various diseases either by exposure to radon in air or in radon rich thermal water. In this study, six test persons were exposed to radon thermal water in a bathtub and the time-dependent radon activity concentration in the exhaled air was recor...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx153
更新日期:2017-11-01 00:00:00