DOSIMETRIC PROPERTIES OF THE NEW TLD ALBEDO NEUTRON DOSEMETER AWST-TL-GD 04.

Abstract:

:A new official albedo dosemeter based on thermoluminescent detectors has been introduced in 2015 by the individual monitoring service of the Helmholtz Zentrum München for monitoring persons who are exposed occupationally against photon and neutron radiation. To enhance the sensitivity for fast neutrons, a new badge with an enlarged albedo window has been developed at TU Dresden. The properties of the new albedo dosemeter are discussed, and the results of official intercomparisons and field calibrations are shown.

journal_name

Radiat Prot Dosimetry

authors

Haninger T,Henniger J

doi

10.1093/rpd/ncv406

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

150-3

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

ncv406

journal_volume

170

pub_type

杂志文章
  • Exposures from nuclear medicine diagnostic procedures: the dose impact on the Aosta Valley population.

    abstract::The present work evaluates the per-procedure, annual collective and per-capita effective doses to the Aosta Valley region population from nuclear medicine (NM) examinations performed from 2005 to 2011 at the regional NM department. Based on its demographical and socioeconomics characteristics, this area can be conside...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct158

    authors: Aimonetto S,Arrichiello C,Peruzzo Cornetto A,Catuzzo P,Zeverino M,Poti C,Meloni T,Pasquino M,Tofani S

    更新日期:2013-12-01 00:00:00

  • No evidence for a low linear energy transfer adaptive response in irradiated RKO cells.

    abstract::It has become increasingly evident from reports in the literature that there are many confounding factors capable of modulating radiation-induced non-targeted responses, such as the bystander effect and the adaptive response. In this paper, we examine recent data which suggest that the observation of non-targeted resp...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq487

    authors: Sowa MB,Goetz W,Baulch JE,Lewis AJ,Morgan WF

    更新日期:2011-02-01 00:00:00

  • INVESTIGATION OF THERMOLUMINESCENCE CHARACTERISTICS OF Y2O3:Er3+ NANOPHOSPHORS.

    abstract::Thermoluminescence (TL) characteristics of Y2O3:Er3+ nanophosphor exposed to UV radiations were investigated. Combustion synthesis method was employed to synthesise the nanophosphors. The confirmation for the pure cubic phase was done by powder X-ray diffraction. The particles formed were found to have 23.19 nm size a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw014

    authors: Kaur M,Bisen DP,Brahme N,Singh P

    更新日期:2017-04-15 00:00:00

  • Radon diffusion coefficients in 360 waterproof materials of different chemical composition.

    abstract::This paper summarises the results of radon diffusion coefficient measurements in 360 common waterproof materials available throughout Europe. The materials were grouped into 26 categories according to their chemical composition. It was found that the diffusion coefficients of materials used for protecting houses again...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr043

    authors: Jiránek M,Kotrbatá M

    更新日期:2011-05-01 00:00:00

  • High-Dose TL Dosimetry of Reactor Neutrons.

    abstract::Radiation dose was measured with set of TL dosimeters during checkout of neutron radiation hardness of the ORTEC preamplifier type 142A in the experiment at the MARIA nuclear reactor at the National Centre for Nuclear Research (NCBJ), Otwock-Świerk, Poland. Different types of LiF-based TL detectors have been used for ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx244

    authors: Obryk B,Malik K,Bilski P,Igielski A,Dankowski J,Kurowski A,Prokopowicz R,Pytel K

    更新日期:2018-08-01 00:00:00

  • Patient dose in digital projection radiography.

    abstract::In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and direct radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Radiology Emergency Department of our hospital, a flat-panel DR equipment (Siemens Axiom Ari...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn013

    authors: Compagnone G,Pagan L,Baleni MC,Calzolaio FL,Barozzi L,Bergamini C

    更新日期:2008-01-01 00:00:00

  • FEASIBILITY OF DISPLAYED EXPOSURE INDEX IN IEC STANDARD FRAMEWORK AS A DOSE OPTIMISATION TOOL FOR DIGITAL RADIOGRAPHY SYSTEMS.

    abstract::International Electrotechnical Commission (IEC) established the framework for the use of exposure index (EI) for evaluating the exposure conditions with various digital systems. In this study, we investigated the feasibility of EI, as per the IEC, by comparing the EIs obtained through manual calculated and that displa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa052

    authors: Park H,Yoon Y,Tanaka N,Kim J,Kim J,Morishita J

    更新日期:2020-07-17 00:00:00

  • Lessons of the 3rd international intercomparison on EPR dosimetry with teeth: similarities and differences of two successful techniques.

    abstract::Despite the considerable improvement in accuracy in comparison with previous intercomparison programmes, the outcome of the recent 3rd International Intercomparison on EPR Tooth Dosimetry has demonstrated that performance of various protocols practised in different laboratories significantly varies. SCRM and MUG took ...

    journal_title:Radiation protection dosimetry

    pub_type:

    doi:10.1093/rpd/nci644

    authors: Chumak V,Ciesielski B,Sholom S,Schultka K

    更新日期:2006-01-01 00:00:00

  • THE CONVERSION OF EXPOSURES DUE TO RADON INTO THE EFFECTIVE DOSE TAKING INTO ACCOUNT THE EQUIVALENCE OF RISKS FROM SHORT- AND LONG-TERM EXPOSURES.

    abstract::The theoretical basis for comparing risks from short- and long-term exposures is developed aiming at implementing long-term exposures into a unique and consistent system of radiation protection. Based on system-analytical considerations, the equivalence of population-averaged risk rates due to prolonged exposures and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv553

    authors: Beck TR

    更新日期:2016-12-01 00:00:00

  • Set-up of a passive Bonner sphere system for neutron spectrometry at mixed fields with predominant photon component based on activation detector.

    abstract::A passive Bonner sphere system (BSS), based on thermal neutron activation detectors, was developed to perform neutron spectrometry in pulsed and very intense (n-gamma) fields with predominant photon component, as those produced by high energy (>10 MV) medical linear electron accelerators. In this paper, a description ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm070

    authors: Amgarou K,Lacoste V,Muller H,Fernández F

    更新日期:2007-01-01 00:00:00

  • Estimation of absorbed doses from paediatric cone-beam CT scans: MOSFET measurements and Monte Carlo simulations.

    abstract::The purpose of this study was to establish a dose estimation tool with Monte Carlo (MC) simulations. A 5-y-old paediatric anthropomorphic phantom was computed tomography (CT) scanned to create a voxelised phantom and used as an input for the abdominal cone-beam CT in a BEAMnrc/EGSnrc MC system. An X-ray tube model of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp257

    authors: Kim S,Yoshizumi TT,Toncheva G,Frush DP,Yin FF

    更新日期:2010-03-01 00:00:00

  • Bremsstrahlung and photoneutron production in a steel shield for 15-22-MeV clinical electron beams.

    abstract::The physical data regarding bremsstrahlung and neutrons produced in a steel shield by high-energy electron beams from a medical linear accelerator were investigated. These data are required to allow the accurate prediction of shielding performance for high-energy electron beams and in the design of radiotherapy facili...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu153

    authors: Fujita Y,Myojoyama A,Saitoh H

    更新日期:2015-02-01 00:00:00

  • 131I DOSE ESTIMATION FROM INTAKE OF TAP WATER IN THE EARLY PHASE AFTER FUKUSHIMA DAIICHI NUCLEAR POWER PLANT ACCIDENT.

    abstract::In March 2011, the Fukushima Daiichi Nuclear Power Plant Accident occurred and a large amount of radionuclides was released. To study its effect, we estimated the internal exposure due to intake of tap water in the early phase after the accident. As the number of measured values of tap water following the accident was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx208

    authors: Kawai M,Yoshizawa N,Suzuki G

    更新日期:2018-04-01 00:00:00

  • Radon in underground waters as a natural analogue to study the escape of CO2 in geological repositories.

    abstract::Activity concentrations of dissolved (222)Rn and (226)Ra were measured in several underground aquifers, which are candidates for repositories or for the study of analogue natural escapes of CO2. The concentration of both radionuclides in water was determined using liquid scintillation counting. The values obtained for...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv232

    authors: Martín Sánchez A,Ruano Sánchez AB,de la Torre Pérez J,Jurado Vargas M

    更新日期:2015-11-01 00:00:00

  • STUDY OF DOSES TO HIPPOCAMPUS OF INTERVENTIONAL CARDIOLOGISTS AND THEIR IMPLICATION FOR DOSIMETRIC MONITORING.

    abstract::Dosimetric monitoring and protection of the personnel involved into interventional procedures is one of the key issues nowadays, yet doses received by their brains were left without rigorous consideration so far. The paper is the fast track of the results of the pilot study of possible magnitude of operator's doses wi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw091

    authors: Chumak V,Morgun A,Bakhanova E,Voloskyi V

    更新日期:2016-09-01 00:00:00

  • Inter-laboratory test program (PTI) in 'neutron dosimetry'.

    abstract::The Laboratory of External Dosimetry Studies and Researches (LRDE), associated laboratory to the Bureau National de Métrologie, is strongly involved in the reference establishment and calibration of instruments in neutron radiation fields provided by 241Am-Be, 252Cf and (252Cf + D2O)/Cd sources. In 1997, on the reques...

    journal_title:Radiation protection dosimetry

    pub_type: 指南,杂志文章,多中心研究

    doi:10.1093/rpd/nch193

    authors: Van-Ryckeghem L,Pelcot G,Suder F,Bureau National de Métrologie.

    更新日期:2004-01-01 00:00:00

  • EXPOSURE ASSESSMENT OF PORTABLE WIRELESS DEVICES ABOVE 6 GHz.

    abstract::The emerging 5 G wireless devices working at frequencies above 6 GHz are expected to have antenna arrays formed by dipoles, slots, patches or their combination. At lower frequencies, the accepted criteria for exposure compliance is stated in terms of specific absorption rate. IEEE and ICNIRP are adopting epithelial or...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy177

    authors: Carrasco E,Colombi D,Foster KR,Ziskin M,Balzano Q

    更新日期:2019-06-01 00:00:00

  • High patient doses in interventional cardiology due to physicians' negligence: how can they be prevented?

    abstract::Interventional cardiology procedures are usually associated with high patient doses and even deterministic radiation effects may occur. Expensive digital flat panels are preferably used to lower doses, and Athens General Hospital has recently installed one. However, this study shows that it is the cardiologists' pract...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn005

    authors: Mavrikou I,Kottou S,Tsapaki V,Neofotistou V

    更新日期:2008-01-01 00:00:00

  • FISH analysis of translocations induced by chronic exposure to Sr radioisotopes: second set of analysis of the Techa River Cohort.

    abstract::Fluorescent in situ hybridisation analysis of stable translocations was performed for 26 residents living along the Techa River (Russia), who were predominantly (95%) exposed to ingested strontium radioisotopes ((89)Sr and (90)Sr) resulting in exposure of their red bone marrow (RBM). Analysis was conducted at the Ural...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu131

    authors: Vozilova AV,Shagina NB,Degteva MO,Moquet J,Ainsbury EA,Darroudi F

    更新日期:2014-06-01 00:00:00

  • Ethical issues in radiology: perspectives from the Christian tradition.

    abstract::The Christian ethical tradition introduces a number of key values into the clinical context. Moreover, although some denominational differences exist, these are essentially differences of emphasis rather than of substance. Among the central values which the Christian tradition promotes are: the dignity of the person, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp044

    authors: Hogan L

    更新日期:2009-07-01 00:00:00

  • MCNPX CALCULATIONS OF SPECIFIC ABSORBED FRACTIONS IN SOME ORGANS OF THE HUMAN BODY DUE TO APPLICATION OF 133Xe, 99mTc and 81mKr RADIONUCLIDES.

    abstract::Monte Carlo simulations were performed to evaluate treatment doses with wide spread used radionuclides 133Xe, 99mTc and 81mKr. These different radionuclides are used in perfusion or ventilation examinations in nuclear medicine and as indicators for cardiovascular and pulmonary diseases. The objective of this work was ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx181

    authors: Jovanovic Z,Krstic D,Nikezic D,Ros JMG,Ferrari P

    更新日期:2018-03-01 00:00:00

  • A new method for determining HT deposition velocity and dependence of the velocity on environmental factors.

    abstract::A new method was developed to determine HT deposition velocity and to investigate how environmental factors affect the deposition processes including the diffusion into soil and the biochemical conversion by microorganisms to HTO in soil. This method, using a chamber and two tritium samplers, enables determination of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006435

    authors: Koarashi J,Amano H,Andoh M,Iida T,Koma T

    更新日期:2001-01-01 00:00:00

  • Determination of diagnostic reference levels in general radiography in Latin America.

    abstract::The International Atomic Energy Agency (IAEA) through the International Action Plan on Radiation Protection of Patients and the International Commission on Radiological Protection have for some time carried out important efforts to assure that in the medical applications of the ionising radiations, the optimisation of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct069

    authors: Blanco S,Mora P,Almonte N,Benavente T,Benson N,Blanco D,Cárdenas J,Defaz Gómez Y,Edding O,Escobar C,Fonseca M,Gamarra M,García Aguilar J,Khoury HJ,Quintero AR,Roas Zuniga N,Zaire E,Nader A

    更新日期:2013-09-01 00:00:00

  • Radon as a potential health hazard for clients and workers of selected thermal spas in Poland.

    abstract::The radiation exposure due to 222Rn and its progeny inhalation for clients and employees of selected thermal water spas was assessed. The radon risk was calculated using the measured 222Rn activity concentrations in the investigated thermal waters and radon transfer coefficient, defined as a fraction of radon released...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw359

    authors: Nowak J,Nguyen Dinh C

    更新日期:2017-07-01 00:00:00

  • Proposal for a patient database on cardiac interventional exposures for epidemiological studies.

    abstract::Relatively high organ doses absorbed by patients in interventional cardiology suggest the opportunity to define these patients as a cohort to be followed forward in time in an epidemiological study of the cancer risks associated with exposure to low-dose ionising radiation. In this paper, the UNSCEAR 2000 Report risk ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncn036

    authors: Malisan MR,Padovani R,Faulkner K,Malone JF,Vaño E,Jankowski J,Kosunen A

    更新日期:2008-01-01 00:00:00

  • The efficiency of various thermoluminescence dosemeter types to heavy ions.

    abstract::Dose verification in heavy-ion beams using passive dosemeter systems, e.g. thermoluminescence dosemeters (TLDs), is crucial due to the changing efficiency of the dosemeters for different ion species and linear energy transfer (LET) values. This behaviour leads to a falsification of absorbed dose that can be significan...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci582

    authors: Berger T,Hajek M,Summerer L,Fugger M,Vana N

    更新日期:2006-01-01 00:00:00

  • Radiation protection at Hadron therapy facilities.

    abstract::The Italian National Centre for Oncological Hadrontherapy is currently under construction in Pavia. It is designed for the treatment of deep-seated tumours (up to a depth of 27 cm of water equivalent) with proton and C-ion beams as well as for both clinical and radiobiological research. The particles will be accelerat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr242

    authors: Pelliccioni M

    更新日期:2011-07-01 00:00:00

  • DETERMINATION OF ACTIVITY PROFILE OF 137CS IN CONCRETE CORE SAMPLES.

    abstract::Decommissioning of nuclear building structures usually leads to large amounts of low-level radioactive waste. Using a reliable method to determine the contamination depth, it is indispensable prior to the start of decontamination works and for minimising the radioactive waste volume and the total workload. This paper ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz223

    authors: Dolniak J,Lištjak M,Slaninka A,Nečas V

    更新日期:2019-12-31 00:00:00

  • Occupational radiation protection of health workers in imaging.

    abstract::Occupational radiological protection (RP) is still a challenge in several clinical practices. ICRP has included specific recommendations and advice for occupational protection in most of the documents published in recent years and its current programme of work includes the preparation of documents with specific conten...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu354

    authors: Vano E

    更新日期:2015-04-01 00:00:00

  • DEVELOPMENT OF A NEW SECONDARY STANDARD FOR H*(10).

    abstract::A secondary standard for ambient dose equivalent, H*(10), is necessary for the dissemination of the unit Sievert (Sv), but there is no such standard commercially available currently. Furthermore, the measurement of H*(10) instead of calculating H*(10) from air kerma and conversion coefficients is needed for unknown ra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz296

    authors: Bairlein K,Behnke B,Hupe O

    更新日期:2020-06-24 00:00:00