Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter.

Abstract:

:In the present paper, we report the indigenous development of a neutron-sensitive thermoluminescent dosemeter (TLD) based on CaSO4:Dy Teflon TL disc. The study includes indigenous development of a neutron dosemeter and its response in terms of operational quantity to different energies of neutrons under various irradiation conditions. It was found that the thermal neutron sensitivity of the CaSO4:Dy Teflon neutron disc is about one-third of TLD-600. However, the thermal neutron sensitivity with respect to CaSO4:Dy Teflon gamma disc is about 42 times for in-air irradiation and about 84 times for on-phantom irradiation condition. This newly developed neutron dosemeter can be used as a routine TLD with a slight change in the design of the TLD badge system in the mixed fields of gamma and neutrons of energy up to 500 keV for radiation workers engaged in nuclear fuel cycle operation and other applications.

journal_name

Radiat Prot Dosimetry

authors

Bakshi AK,Pradhan AS,Kher RK,Srivastava K,Varadharajan G,Chatterjee S,Sathian V

doi

10.1093/rpd/ncp019

subject

Has Abstract

pub_date

2009-01-01 00:00:00

pages

73-80

issue

2

eissn

0144-8420

issn

1742-3406

pii

ncp019

journal_volume

133

pub_type

杂志文章
  • Internal dose assessment in radiation accidents.

    abstract::Although numerous models have been developed for occupational and medical internal dosimetry, they may not be applicable to an accident situation. Published dose coefficients relate effective dose to intake, but if acute deterministic effects are possible, effective dose is not a useful parameter. Consequently, dose r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006250

    authors: Toohey RE

    更新日期:2003-01-01 00:00:00

  • Energy dependence of W values of protons in water.

    abstract::The W values of protons in water vapour were measured for energies from 1 keV to 100 keV with uncertainties lower than 1%. To study the energy and phase dependence of W values, the W values of protons in water vapour and liquid water were calculated for energies from 0.1 keV and 10 MeV and then compared to the experim...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006798

    authors: Willems G,Back WY,Grosswendt B

    更新日期:2002-01-01 00:00:00

  • European Study of Occupational Radiation Exposure (ESOREX).

    abstract::The European Study of Occupational Radiation Exposure (ESOREX) project was initiated by the general directive EC DG XI and carried out by the Bundesamt für Strahlenschutz, Germany (BfS). It consists of surveys carried out in the 28 European states. The study provides comparable descriptions of the national administrat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006602

    authors: Frasch G,Anatschkowa E,Kragh P

    更新日期:2001-01-01 00:00:00

  • A combination study of indoor radon and in situ gamma spectrometry measurements in Greek dwellings.

    abstract::The aim of the present study was to investigate of a possible correlation between indoor radon and indoor gamma dose rates deduced by in situ gamma spectrometry measurements by using a portable HPGe detector. Indoor radon and high resolution in situ gamma spectrometry measurements were performed in 60 apartments in Th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006154

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2003-01-01 00:00:00

  • Radon in earthquake prediction research.

    abstract::The observation of anomalies in the radon concentration in soil gas and ground water before earthquakes initiated systematic investigations on earthquake precursor phenomena. The question what is needed for a meaningful earthquake prediction as well as what types of precursory effects can be expected is shortly discus...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr229

    authors: Friedmann H

    更新日期:2012-04-01 00:00:00

  • Assessment of natural radioactivity and the associated hazards in Iranian cement.

    abstract::This paper presents the finding of a study undertaken to determine natural radioactivity and associated hazards in local types of cement in Iran. A total of 42 samples were collected from various manufacturers and suppliers and analysed using a shielded HPGe gamma-ray spectrometer. The specific activities of 232Th, 22...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl549

    authors: Fathivand AA,Amidi J

    更新日期:2007-01-01 00:00:00

  • Modelling urinary excretion of molybdenum after oral and intravenous administration of stable tracers.

    abstract::An extensive study using stable isotopes of molybdenum as tracers was undertaken to investigate intestinal uptake, systemic kinetics and urinary excretion of molybdenum in healthy human volunteers. In total 63 experiments with 17 volunteers were performed administering the tracers in different chemical forms and measu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm263

    authors: Giussani A,Cantone MC,Höllriegl V,Oeh U,Tavola F,Veronese I

    更新日期:2007-01-01 00:00:00

  • Personal radon dosimetry from eyeglass lenses.

    abstract::Eyeglass lenses are commonly composed of allyl-diglycol carbonate (CR-39), an alpha-particle detecting plastic, thus making such lenses personal radon dosemeters. Samples of such lenses have been obtained, etched to reveal that radon and radon progeny alpha tracks can be seen in abundance, and sensitivities have been ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006670

    authors: Fleischer RL,Meyer NR,Hadley SA,MacDonald J,Cavallo A

    更新日期:2001-01-01 00:00:00

  • Radioactivity and dose assessment of marble samples from Igbeti mines, Nigeria.

    abstract::The concentration and distribution of natural radionuclides in marble around Igbeti marble mines, Nigeria, were measured to evaluate the environmental radioactivity and health effects which the marble samples may posses. The concentration of radionuclides was determined using gamma-ray spectrometry with NaI (Tl) detec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn279

    authors: Ademola AK,Hammed OS,Adejumobi CA

    更新日期:2008-01-01 00:00:00

  • The influence of novel CT reconstruction technique and ECG-gated technique on image quality and patient dose of cardiac computed tomography.

    abstract::The aim of the present study was to compare image quality and patient dose in cardiac computed tomography angiography (CTA) in terms of volume computed tomography dose index (CTDI vol), dose length product (DLP) and effective dose, when changing from filtered back projection (FBP) to adaptive iterative dose reduction ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv114

    authors: Dyakov I,Stoinova V,Groudeva V,Vassileva J

    更新日期:2015-07-01 00:00:00

  • Studies on internal exposure doses received by the cuban population due to the intake of radionuclides from the environmental sources.

    abstract::Studies for the determination of radionuclide concentrations in foodstuffs, water and air were carried out in Cuba for the estimation of annual committed effective doses to members of the public as a result of environmental radionuclides via ingestion and inhalation. As a result of these studies, it was possible to de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl002

    authors: Tomás Zerquera J,Prendes Alonso M,Fernández Gómez IM,Rodríguez Castro GV,Martínez Ricardo N,López Bejerano G,Ara do López JO,Acosta Rodríguez N,Carrazana González J,Brígido Flores O,Hernández Pérez A,Díaz Rizo O

    更新日期:2006-01-01 00:00:00

  • Induced radioactivity in and around high-energy particle accelerators.

    abstract::Particle accelerators and their surroundings are locations of residual radioactivity production that is induced by the interaction of high-energy particles with matter. This paper gives an overview of the principles of activation caused at proton accelerators, which are the main machines operated at Conseil Européen p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr245

    authors: Vincke H,Theis C,Roesler S

    更新日期:2011-07-01 00:00:00

  • ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.

    abstract::The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protect...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci702

    authors: Vano E,Faulkner K

    更新日期:2005-01-01 00:00:00

  • Foods found in the wild around nuclear sites: an evaluation of radiological impact.

    abstract::Habit surveys were carried out around four licensed nuclear sites to identify people who collect foodstuffs from the wild (so-called 'free foods'). In total, around 800 collectors were readily identified, most of whom collected more than one free food. The data indicated that estimates of higher than average doses cou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006415

    authors: Green N,Wilkins BT,Hammond DJ,Davidson MF,Richmond S,Brooker S

    更新日期:2001-01-01 00:00:00

  • Specific absorbed fraction for Korean adult voxel phantom from internal photon source.

    abstract::Absorbed fraction (AF) and specific absorbed fraction (SAF) are crucial values for the calculation of radionuclide S-values and consequently for internal dose estimates. The formalism of the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine (SNM) has been utilised as a standard in the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl167

    authors: Lee C,Park S,Lee JK

    更新日期:2007-01-01 00:00:00

  • Assessment of paediatric CT exposure in a Portuguese hospital.

    abstract::In this study, the characterisation of radiation exposure of paediatric patients in computerised tomography (CT) procedures was performed for a Portuguese hospital. Dosimetric data and technical parameters used for CT examinations were retrieved, compiled and analysed over a period of 1 y. Five paediatric age groups w...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs037

    authors: Neves A,Nunes A,Rufino M,Madeira P,Vaz P,Pascoal A

    更新日期:2012-09-01 00:00:00

  • Radiological emergency: Malaysian preparedness and response.

    abstract::Planning and preparation in advance for radiological emergencies can help to minimise potential public health and environmental threats if and when an actual emergency occurs. During the planning process, emergency response organisations think through how they would respond to each type of incident and the resources t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr102

    authors: Yusof MA,Ali HM

    更新日期:2011-07-01 00:00:00

  • Electron spin resonance evaluation of pure CaSO4 and as a phosphor doped with P and Dy.

    abstract::Polycrystalline CaSO4 powder, doped with different elements but mainly rare earths, is one of the most interesting thermoluminescent (TL) materials. Although many electron spin resonance (ESR) analyses have been reported for these materials few studies have been published about the potential of CaSO4 for ESR dosimetry...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006047

    authors: de Jesus EF,Rossi AM,Lopes RT

    更新日期:2002-01-01 00:00:00

  • Intercomparison of patient CTDI surveys in three countries.

    abstract::The results of large-scale computed tomography (CT) patient dose surveys from the USA, UK and Germany undertaken during the period 1999-2001 were reviewed. The mean values for volume-weighted CT dose index (CTDI(vol)) and dose length product (DLP) were extracted. For head CT examinations, the reported values for the t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs123

    authors: Martin CJ,Huda W

    更新日期:2013-01-01 00:00:00

  • Applicability of convex hull in multiple detector response space for neutron dose measurements.

    abstract::A novel neutron dose measurement method that flexibly responds to variations in the neutron field is being developed by Japan Atomic Energy Agency. This is an implementation of the multi-detector method (first introduced in 1960s) for neutron dose evaluation using a convex hull in the response space defined for multip...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp134

    authors: Hashimoto M,Iimoto T,Kosako T

    更新日期:2009-08-01 00:00:00

  • Indoor radon and thoron levels in Neendakara and Chavara regions of southern coastal Kerala, India.

    abstract::Some areas of the world, called high background radiation areas (HBRAs), have anomalously high levels of natural background radiation and the population residing in the areas is exposed to higher levels of radiation doses than other parts of the world where the natural radioactivity contents are normal. In the present...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr399

    authors: Pereira CE,Vaidyan VK,Chougaonkar MP,Mayya YS,Sahoo BK,Jojo PJ

    更新日期:2012-07-01 00:00:00

  • THE DECADE OF THE RABiT (2005-15).

    abstract::The RABiT (Rapid Automated Biodosimetry Tool) is a dedicated Robotic platform for the automation of cytogenetics-based biodosimetry assays. The RABiT was developed to fulfill the critical requirement for triage following a mass radiological or nuclear event. Starting from well-characterized and accepted assays we deve...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw172

    authors: Garty G,Turner HC,Salerno A,Bertucci A,Zhang J,Chen Y,Dutta A,Sharma P,Bian D,Taveras M,Wang H,Bhatla A,Balajee A,Bigelow AW,Repin M,Lyulko OV,Simaan N,Yao YL,Brenner DJ

    更新日期:2016-12-01 00:00:00

  • Biokinetics of radionuclides and treatment of accidental intakes.

    abstract::This paper describes the objectives and reviews the progress of EULEP Working Party 5, convened under the auspices of the European Union's Fifth Framework Programme, to 'cluster' two EU-supported contracts, Biokinetics and Dosimetry of Internal Contamination (BIODOS (EU Contract FIS5-1999-00214)) and Radionuclide Biok...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006318

    authors: Taylor DM,Stradling GN,Ménétrier F

    更新日期:2003-01-01 00:00:00

  • EFFECTIVE INDOOR DOSE OF GAMMA RADIATION FROM BUILDING MATERIALS: COMPARISON OF SEVERAL METHODS FOR ESTIMATION AND POSSIBLE UNDERESTIMATE.

    abstract::This paper compares several methods for estimation of the effective indoor dose of gamma radiation from building materials. It was found that specific dose ratios proposed for 3 cm thick layers in one recommendation gives 2.8 times lower value of gamma dose than other methods. The most common case is that granite has ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa125

    authors: Krmar M,Milić K,Arsenić I,Hansman J

    更新日期:2020-10-16 00:00:00

  • Indoor radon measurements in the dwellings of Punjab and Himachal Pradesh, India.

    abstract::The measurement of indoor radon concentrations were performed in the dwellings of the Punjab and Himachal Pradesh, India by using LR-115 type II Solid-State Nuclear Track Detectors in the bare mode. The annual average indoor radon concentrations in the dwellings are found to vary from 114 to 400 Bq m(-3) with an avera...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct041

    authors: Rani A,Singh S,Duggal V

    更新日期:2013-01-01 00:00:00

  • Effective dose calculations in conventional diagnostic X-ray examinations for adult and paediatric patients in a large Italian hospital.

    abstract::The effective dose E is an efficient and powerful parameter to study the radioprotection of the patient. In our hospital, eight radiological departments and more than 100 radiological X-ray tubes are present. The effective doses were calculated for adults and paediatric patients in 10 standard projections. To calculat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch508

    authors: Compagnone G,Pagan L,Bergamini C

    更新日期:2005-01-01 00:00:00

  • RADIATION DOSE IS OF LIMITED CLINICAL USEFULNESS IN PERSONS WITH ACUTE RADIATION SYNDROME.

    abstract::The relation of radiation exposure (dose) with acute radiation syndrome (ARS) depends on many factors. In this overview, we reconsider (1) radiation exposure characteristics (e.g. radiation quality, fractionation, dose rate, partial/total body irradiation) and (2) biological processes (e.g. radiosensitivity, cell cycl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz058

    authors: Port M,Majewski M,Abend M

    更新日期:2019-12-31 00:00:00

  • Radiation-induced DNA damage responses.

    abstract::The amazing feature of ionising radiation (IR) as a DNA damaging agent is the range of lesions it induces. Such lesions include base damage, single strand breaks (SSBs), double strand breaks (DSBs) of varying complexity and DNA cross links. A range of DNA damage response mechanisms operate to help maintain genomic sta...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncl495

    authors: Jeggo P,Löbrich M

    更新日期:2006-01-01 00:00:00

  • Low-dose spine CT: optimisation and clinical implementation.

    abstract::Spinal deformities affect young individuals predominantly girls who are usually subjected to regular and intensive radiological investigation especially before and after corrective surgery. Optimisation of spine computed tomography (CT) and the implementation of the low-dose CT in the work-up of spinal deformities wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp306

    authors: Abul-Kasim K

    更新日期:2010-04-01 00:00:00

  • COMPARISON OF MCNP AND VISIPLAN DOSE-FIELD CALCULATIONS FOR MULTILAYER SHIELDING.

    abstract::An important factor in calculation of quantities describing the radiation situation is the selection of a calculation code. In this article, the radiation situation for selected geometries with multilayer shields was judged. Calculations were carried out using deterministic code VISIPLAN and stochastic code MCNP5. Int...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz224

    authors: Bednár D,Lištjak M,Slimák A,Nečas V

    更新日期:2019-12-31 00:00:00