Simultaneous Measurements of Nanoaerosols and Radioactive Aerosols Containing the Short-lived Radon Isotopes.

Abstract:

:The activity size distribution of the Equilibrium-Equivalent Concentration (EER) of 222Rn is one of the most important parameters for the estimation of radiation dose by inhalation of radon decay products. A series of measurements of the EER activity size distribution were performed by the screen diffusion battery in Radon-Aerosol chamber (10 m3) at the National Institute for Nuclear, Chemical, and Biological Protection (SUJCHBO). These measurements were performed at different levels of radon concentration. For this study, the Graded Screen Array Diffusion Battery (GSA DB), developed by the SUJCHBO (based on Earl Knutson and Robert F Holub design), consists of 10 screens and backup filter used to collect all particles that penetrated the screens. The measuring range of this GSA DB allows measuring the radioactive nanoaerosols in the size range from 0.5 to 100 nm. The Earl Knutson algorithm was used for EER activity size distribution evaluation. The results of EER activity size distribution were subsequently compared with the aerosol particle size distribution measured by Scanning Mobility Particle Sizer Spectrometer (SMPS 3936 N, TSI Inc., MN, USA).

journal_name

Radiat Prot Dosimetry

authors

Otahal PPS,Burian I,Ondracek J,Zdimal V,Holub RF

doi

10.1093/rpd/ncx157

subject

Has Abstract

pub_date

2017-11-01 00:00:00

pages

53-56

issue

1-2

eissn

0144-8420

issn

1742-3406

pii

4161658

journal_volume

177

pub_type

杂志文章
  • Design of a multi-element TEPC for neutron monitoring.

    abstract::Tissue-equivalent proportional counters (TEPCs) have long been considered suitable candidate instruments for more accurate neutron monitors in nuclear power plants. It has also been recognised that the production of truly light-weight devices based on TEPCs requires further effort directed towards increasing their sen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq538

    authors: Waker AJ,Aslam,Lori J

    更新日期:2011-02-01 00:00:00

  • PARALLELISATION OF THE MODEL-BASED ITERATIVE RECONSTRUCTION ALGORITHM DIRA.

    abstract::New paradigms for parallel programming have been devised to simplify software development on multi-core processors and many-core graphical processing units (GPU). Despite their obvious benefits, the parallelisation of existing computer programs is not an easy task. In this work, the use of the Open Multiprocessing (Op...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv430

    authors: Örtenberg A,Magnusson M,Sandborg M,Alm Carlsson G,Malusek A

    更新日期:2016-06-01 00:00:00

  • Radioactive waste management and decommissioning of accelerator facilities.

    abstract::During the operation of high-energy accelerators, the interaction of radiation with matter can lead to the activation of the machine components and of the surrounding infrastructures. As a result of maintenance operation and during decommissioning of the installation, considerable amounts of radioactive waste are evac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp196

    authors: Ulrici L,Magistris M

    更新日期:2009-11-01 00:00:00

  • Investigation of combined unfolding of neutron spectra using the UMG unfolding codes.

    abstract::An investigation of the simultaneous unfolding of data from neutron spectrometers using the UMG codes MAXED and GRAVEL has been performed. This approach involves combining the data from the spectrometers before unfolding, thereby performing a single combined unfolding of all the data to yield a final combined spectrum...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm082

    authors: Roberts NJ

    更新日期:2007-01-01 00:00:00

  • Measurements of radon gas concentrations in dwellings of Al-Madinah Al-Munawarah province in Saudi Arabia.

    abstract::Indoor radon concentration levels in a large number of dwellings in Al-Madinah Al-Munawarah Province have been measured. Al-Madinah Al-Munawarah is in the western region of Saudi Arabia. It is the second holiest city in Islam after Mecca, because it is the burial place of the Islamic Prophet Muhammad. The city was div...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct219

    authors: Mohamed RI,Alfull ZZ,Dawood ND

    更新日期:2014-01-01 00:00:00

  • The analysis of thermoluminescent glow peaks of natural calcite after beta irradiation.

    abstract::In this study, the thermoluminescence properties of natural calcite samples were examined in detail. The glow curve of the sample irradiated with beta radiation shows two main peaks, P1 (at 115 °C) and P4 (at 254 °C). The additive dose, variable heating rate, computer glow curve deconvolution, peak shape and three poi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs020

    authors: Yildirim RG,Kafadar VE,Yazici AN,Gün E

    更新日期:2012-09-01 00:00:00

  • Quality assurance (QA) procedures for software: evaluation of an ADC quality system.

    abstract::Image viewing and processing software in computed radiography manipulates image contrast in such a way that all relevant image features are rendered to an appropriate degree of visibility, and improves image quality using enhancement algorithms. The purpose of this study was to investigate procedures for the quality a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci742

    authors: Efstathopoulos EP,Benekos O,Molfetas M,Charou E,Kottou S,Argentos S,Kelekis NL

    更新日期:2005-01-01 00:00:00

  • Reconstruction of cluster distributions at 100% detection efficiency for a track-nanodosimetric counter through a Bayesian analysis.

    abstract::A Bayesian unfolding has been applied to ionisation distributions due to 5.4 MeV alpha particles in a 20-nm site obtained using Monte Carlo simulations, taking into account different detection efficiency conditions. The ideal case of a target volume with uniform efficiency has been investigated to study the dependence...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch143

    authors: De Nardo L,Lesimple M,Canella S,Grosswendt B

    更新日期:2004-01-01 00:00:00

  • Hp(3)/Φ conversion coefficients for neutrons: discussion on the basis of the new ICRP recommended limit for the eye lens.

    abstract::The new recommendation issued by the International Commission on Radiological Protection (ICRP) introducing a 20-mSv annual dose limit for the eye lens stimulated an interesting debate among the radiation protection community. In the present work the problem of estimating Hp(3) for neutron realistic workplace spectra ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct246

    authors: Ferrari P,Gualdrini G,Tanner R,Fantuzzi E

    更新日期:2014-10-01 00:00:00

  • A legally approved personal dosemeter for photon and beta radiation based on direct ion storage.

    abstract::The novel DIS-1 dosemeter developed by RADOS is based on ionisation chambers with so-called Direct Ion Storage (DIS). The dosemeter can measure Hp(10) and Hp(0.07) of photon and Hp(0.07) of beta irradiation. The characteristics of the commercially available DIS-1 dosemeter were studied at the Paul Scherrer Institute, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005984

    authors: Boschung M,Fiechtner A,Wernli C

    更新日期:2002-01-01 00:00:00

  • Thermal diffusion of radon in porous media.

    abstract::Based on the non-intersection model of cylindrical capillaries, the mean radius of the pores of some soils and building materials are estimated. In size, the above-mentioned radii are usually of the order of the free path of gas molecules at atmospheric pressure. A review of pore size distribution data also reveals th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006360

    authors: Minkin L

    更新日期:2003-01-01 00:00:00

  • The study of activity median aerodynamic diameter using imaging plate technique for assessment of effective dose from radon and its decay products.

    abstract::The indoor workplace environment was evaluated for exposure to radon and its decay products at two Universities in two metropolises of Japan. The mean radon concentrations in Nagoya University (NU) and Hokkaido University (HU) were 16.7 Bq m(-3) and 18.0 Bq m(-3), respectively. Activity median aerodynamic diameter (AM...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncm221

    authors: Rahman NM,Iida T,Yamazawa H,Yokoyama S,Moriizumi J,Saito F,Ito T

    更新日期:2007-01-01 00:00:00

  • The IUR Forum: Worldwide Harmonisation of Networks to Support Integration of Scientific Knowledge and Consensus Development in Radioecology.

    abstract::During the past decades, many specialised networks have formed to meet specific radioecological objectives, whether regional or sectorial (purpose-oriented). Regional networks deal with an array of radioecological issues related to their territories. Examples include the South Pacific network of radioecologists, and t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw290

    authors: Bréchignac F,Alexakhin R,Bollhöfer A,Frogg KE,Hardeman F,Higley K,Hinton TG,Kapustka LA,Kuhne W,Leonard K,Masson O,Nanba K,Smith G,Smith K,Strand P,Vandenhove H,Yankovich T,Yoshida S

    更新日期:2017-04-01 00:00:00

  • Dose assessment for ingestion of a 330 kilobecquerel 60Co hot particle.

    abstract::On leaving the irradiated fuel bay at Pickering A nuclear power station, a worker triggered a whole body monitor alarm with activity in or on his head, and despite careful decontamination techniques he subsequently swallowed a hot particle. Over the next 3 d, the radioactivity was tracked through the body. It was then...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm256

    authors: Whillans DW,Chase WJ,Wolodarsky WH

    更新日期:2007-01-01 00:00:00

  • A comparison of the response of PADC neutron dosemeters in high-energy neutron fields.

    abstract::Within the framework of the EURADOS Working Group 11, a comparison of passive neutron dosemeters in high-energy neutron fields was organised in 2011. The aim of the exercise was to evaluate the response of poly-allyl-glycol-carbonate neutron dosemeters from various European dosimetry laboratories to high-energy neutro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct275

    authors: Trompier F,Boschung M,Buffler A,Domingo C,Cale E,Chevallier MA,Esposito A,Ferrarini M,Geduld DR,Hager L,Hohmann E,Mayer S,Musso A,Romero-Esposito M,Röttger S,Smit FD,Sashala Naik A,Tanner R,Wissmann F,Caresana M

    更新日期:2014-10-01 00:00:00

  • A Monte-Carlo code for the detailed simulation of electron and light-ion tracks in condensed matter.

    abstract::In an effort to understand the basic mechanism of the action of charged particles in solid radiation dosimeters, we extend our Monte-Carlo code (MC4) to condensed media (liquids/solids) and present new track-structure calculations for electrons and protons. Modeling the energy dissipation process is based on a model d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci671

    authors: Emfietzoglou D,Papamichael G,Karava K,Androulidakis I,Pathak A,Phillips GW,Moscovitch M,Kostarelos K

    更新日期:2006-01-01 00:00:00

  • ISO 4037:2019 VALIDATION OF RADIATION QUALITIES BY MEANS OF HALF-VALUE LAYER AND HP(10) DOSIMETRY.

    abstract::Radiation qualities were characterised and validated at the fully automated X-ray calibration facility of the Individual Monitoring Service at Helmholtz Zentrum München by using half-value layer and Hp(10) dosimetry approaches specified in the updated ISO 4037:2019 standard. As the ISO 4037 contains a somewhat vague d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz185

    authors: Bandalo V,Greiter MB,Brönner J,Hoedlmoser H

    更新日期:2019-12-31 00:00:00

  • INVESTIGATION OF THERMOLUMINESCENCE CHARACTERISTICS OF Y2O3:Er3+ NANOPHOSPHORS.

    abstract::Thermoluminescence (TL) characteristics of Y2O3:Er3+ nanophosphor exposed to UV radiations were investigated. Combustion synthesis method was employed to synthesise the nanophosphors. The confirmation for the pure cubic phase was done by powder X-ray diffraction. The particles formed were found to have 23.19 nm size a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw014

    authors: Kaur M,Bisen DP,Brahme N,Singh P

    更新日期:2017-04-15 00:00:00

  • A survey of patient dose and clinical factors in a full-field digital mammography system.

    abstract::In this work, we analyse the dose to 5034 patients (20 137 images) who underwent mammographic examinations with a full-field digital mammography (FFDM) system over a 2-y period. The information relevant to this study has been extracted from the image Digital Imaging and Communications in Medicine (DICOM) headers. Entr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch514

    authors: Morán P,Chevalier M,Ten JI,Fernández Soto JM,Vañó E

    更新日期:2005-01-01 00:00:00

  • Anatomical data and development of geometric models for the knee region bones.

    abstract::Analytical geometric models for the bones of the knee region have been developed. A survey was done on real pieces to obtain the dimensions of the geometric sections used in each model. The dependence of the section dimensions on the bone length and the estimated dimensions of the bones for a 1.70 m tall person are pr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm445

    authors: Venturini L,Sordi GM,Fernandes F

    更新日期:2008-01-01 00:00:00

  • Development of a new thoron progeny detector based on SSNTD and the collection by an electric field.

    abstract::The importance of (220)Rn (thoron) progeny for human exposure has been widely recognised in the past decades. Since no stable equilibrium factor was found between indoor thoron and its progeny, and the concentration of thoron progeny varies with time, it is necessary to develop detectors for long-term measurement that...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr078

    authors: Bi L,Tschiersch J,Meisenberg O,Wielunski M,Li JL,Shang B

    更新日期:2011-05-01 00:00:00

  • Minimising activity and dose with enhanced image quality by radiopharmaceutical administrations.

    abstract::Owing to the introduction of new diagnostic procedures, such as computed tomography (CT), positron emission tomography (PET) and single photon emission computed tomography (SPECT), the individual dose caused by medical exposures has grown rapidly in the last years. This is especially a subject to radiation protection ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq104

    authors: Hoeschen C,Mattsson S,Cantone MC,Mikuz M,Lacasta C,Ebel G,Clinthorne N,Giussani A

    更新日期:2010-04-01 00:00:00

  • A study of the correlation between dose area product and effective dose in vascular radiology.

    abstract::The purpose of the multi-centre study was to assess dose area product (DAP) and effective dose of patients undergoing angiography of the lower limbs in Belgium and to investigate the correlation between DAP and effective dose. DAP values were measured in 12 centres and compared with the national diagnostic reference l...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn050

    authors: Smans K,Struelens L,Hoornaert MT,Bleeser F,Buls N,Berus D,Clerinx P,Malchair F,Vanhavere F,Bosmans H

    更新日期:2008-01-01 00:00:00

  • Panel discussion: Do non-targeted effects impact the relation between microdosimetry and risk?

    abstract::An invited panel discussed with the participants of the Symposium their views on the impact of non-targeted effects on the relationship between microdosimetry and risk. The discussion was wide ranging and lively, with divergences of opinion. At one end was the view that understanding microscopic features and distribut...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq393

    authors: Goodhead DT

    更新日期:2011-02-01 00:00:00

  • Development of thermal neutron-sensitive glass dosemeter containing lithium.

    abstract::New radiophotoluminescence (RPL) phosphate glass containing (6)Li was successfully made from the powder of NaPO(3), Al(PO(3))(3), LiOH, HPO(3) and AgCl. The ternary diagram of NaPO(3)-Al(PO(3))(3)-LiPO(3) has clarified the region where satisfactory RPL characteristics of the glass are kept up. The synthesised phosphat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq552

    authors: Maki D,Kobayashi H,Sato F,Murata I,Kato Y,Tanaka T,Yamamoto T,Iida T

    更新日期:2011-03-01 00:00:00

  • EURADOS coordinated action on research, quality assurance and training of internal dose assessments.

    abstract::EURADOS working group on 'Internal Dosimetry (WG7)' represents a frame to develop activities in the field of internal exposures as coordinated actions on quality assurance (QA), research and training. The main tasks to carry out are the update of the IDEAS Guidelines as a reference document for the internal dosimetry ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq435

    authors: Lopez MA,Balásházy I,Bérard P,Blanchardon E,Breustedt B,Broggio D,Castellani CM,Franck D,Giussani A,Hurtgen C,James AC,Klein W,Kramer GH,Li WB,Marsh JW,Malatova I,Nosske D,Oeh U,Pan G,Puncher M,Peixoto Telles P,

    更新日期:2011-03-01 00:00:00

  • Determination of committed effective doses to skin due to ²³⁸U, ²³²Th and ²²²Rn from the application of various Moroccan black soap (Saboun Beldi) samples by members of the general public.

    abstract::(238)U, (232)Th, (222)Rn and (220)Rn concentrations were measured inside various Moroccan black soap samples widely used by the Moroccan population in traditional baths (Hammans) by using both CR-39 and LR-115 type II solid state nuclear track detectors. The measured (238)U, (232)Th, (222)Rn and (220)Rn concentrations...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq275

    authors: Misdaq MA,Outeqablit K

    更新日期:2010-12-01 00:00:00

  • On the use of LiF TLD-600 in neutron-gamma mixed fields.

    abstract::A new procedure allowing the separate estimation of neutron and gamma dose in mixed radiation fields has been developed in our laboratory. In this communication, a description of the main features of the discrimination procedure and some preliminary results obtained by its use are presented. The procedure is based on ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm210

    authors: Delgado A,Muñiz JL,Gómez Ros JM,Romero AM,Rodríguez R

    更新日期:2007-01-01 00:00:00

  • Plutonium isotopes in marine sediments and some biota from the Sudanese coast of the Red Sea.

    abstract::Measurements of (239+240)Pu and (238)Pu were carried out on marine biota as well as on sediments from the fringing reefs area extending towards north and south (Flamingo Bay) of PortSudan harbour. The analyses were performed using radiochemical separation and alpha spectrometry. The range of the activity concentration...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn193

    authors: Sirelkhatim DA,Sam AK,Hassona RK

    更新日期:2008-01-01 00:00:00

  • CT equipment and performance issues: radiation protection 162.

    abstract::Since the development of the CT scanner in the early 1970s, CT scanner technology has continuously developed through technical advancement, faster computer processing, superior detectors and helical and multi-detector scanning modes. As a result, the scope of clinical examinations has broadened considerably, and in pa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs285

    authors: Edyvean S

    更新日期:2013-02-01 00:00:00