Anatomical data and development of geometric models for the knee region bones.

Abstract:

:Analytical geometric models for the bones of the knee region have been developed. A survey was done on real pieces to obtain the dimensions of the geometric sections used in each model. The dependence of the section dimensions on the bone length and the estimated dimensions of the bones for a 1.70 m tall person are presented. A parameter that attempts to relate the person's height to the bone length was included. Using reference data for the tissues and for bone composition, the models represent 8.7% (each knee) of a 10 kg skeleton and present the following densities: femur and tibia 1590 kg m(-3), fibula 1660 kg m(-3) and patella 1720 kg m(-3).

journal_name

Radiat Prot Dosimetry

authors

Venturini L,Sordi GM,Fernandes F

doi

10.1093/rpd/ncm445

subject

Has Abstract

pub_date

2008-01-01 00:00:00

pages

486-90

issue

4

eissn

0144-8420

issn

1742-3406

pii

ncm445

journal_volume

129

pub_type

杂志文章
  • One cubic metre NIST traceable radon test chamber.

    abstract::With the availability of the National Institute of Standards and Technology (NIST) Radon Emanation Standard with a content of approximately 5000 Bq of 226Ra, it is possible to build a flow through a practical radon test chamber. A standard glove box with four gloves and a transfer port is used. Air is pumped through a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm430

    authors: Kotrappa P,Stieff F

    更新日期:2008-01-01 00:00:00

  • Energy dependence of W values of protons in water.

    abstract::The W values of protons in water vapour were measured for energies from 1 keV to 100 keV with uncertainties lower than 1%. To study the energy and phase dependence of W values, the W values of protons in water vapour and liquid water were calculated for energies from 0.1 keV and 10 MeV and then compared to the experim...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006798

    authors: Willems G,Back WY,Grosswendt B

    更新日期:2002-01-01 00:00:00

  • Neutron spectrometry in a PET cyclotron with a Bonner sphere system.

    abstract::Positron emission tomography (PET) is a non-invasive medical imaging technique normally used for diagnostic purposes to determine the location and concentration of physiologically active compounds in a human body. An unshielded cyclotron is used for PET at the Clinica Universitaria de Navarra to produce short-lived po...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm077

    authors: Fernández F,Amgarou K,Domingo C,García MJ,Quincoces G,Martí-Climent JM,Méndez R,Barquero R

    更新日期:2007-01-01 00:00:00

  • CHARACTERIZATION OF FLUORESCENT NUCLEAR TRACK DETECTORS AS CRITICALITY DOSIMETERS II.

    abstract::Fluorescent nuclear track detectors (FNTDs) as criticality dosimeters for both neutrons and gamma are further characterized in terms of angular dependence and quick dose assessment. The power spectrum integral depth profiles obtained from stacks of fluorescent images acquired within FNTDs exposed to a broad spectrum n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx236

    authors: Harrison J,Moreno B,Van Hoey O,Mihailescu LC,Vanhavere F,Million M,Fomenko V,Akselrod M

    更新日期:2018-08-01 00:00:00

  • Dose trends in occupational radiation exposure in Europe results from the ESOREX project.

    abstract::The ESOREX project was initiated in 1997 by the EC DG TREN and it was executed by the BfS/Germany in close co-operation with the State Office for Nuclear Safety/Czech Republic). It consists of surveys on radiation monitoring and exposure carried out in the 30 European states. The study provides comparable descriptions...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl566

    authors: Frasch G,Petrová K

    更新日期:2007-01-01 00:00:00

  • Detection system built from commercial integrated circuits for real-time measurement of radiation dose and quality using the variance method.

    abstract::A small, specialised amplifier using commercial integrated circuits (ICs) was developed to measure radiation dose and quality in real time using a microdosimetric ion chamber and the variance method. The charges from a microdosimetric ion chamber, operated in the current mode, were repeatedly collected for a fixed per...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm231

    authors: Hsu WH,Braby LA,Reece WD

    更新日期:2008-01-01 00:00:00

  • Magnetic field tracking with MCNP5.

    abstract::With the introduction of continuous-energy heavy charged particle transport in MCNP5, the need for tracking charged particles in a magnetic field becomes increasingly important. Two methods for including magnetic field effects on charged particles are included in the proton transport version of the code. The first tec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci048

    authors: Bul JS,Hughes HG,Walstrom PL,Zumbro JD,Mokhov NV

    更新日期:2005-01-01 00:00:00

  • Extremity dosimetry trial: Devonport Royal Dockyard.

    abstract::This trial was undertaken to assess extremity dosemeters, which were made available to Devonport Royal Dockyard and determine the most suitable to the site. The trial included operational and laboratory-based exposures. Operational exposures were within a submarine reactor compartment and a waste storage area. Laborat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn052

    authors: Kenyon R,Collison R

    更新日期:2008-01-01 00:00:00

  • EURADOS coordinated action on research, quality assurance and training of internal dose assessments.

    abstract::EURADOS working group on 'Internal Dosimetry (WG7)' represents a frame to develop activities in the field of internal exposures as coordinated actions on quality assurance (QA), research and training. The main tasks to carry out are the update of the IDEAS Guidelines as a reference document for the internal dosimetry ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq435

    authors: Lopez MA,Balásházy I,Bérard P,Blanchardon E,Breustedt B,Broggio D,Castellani CM,Franck D,Giussani A,Hurtgen C,James AC,Klein W,Kramer GH,Li WB,Marsh JW,Malatova I,Nosske D,Oeh U,Pan G,Puncher M,Peixoto Telles P,

    更新日期:2011-03-01 00:00:00

  • Computed tomography dose index for head CT in northern Nigeria.

    abstract::Computed tomography dose index w and dose length product were recorded for the purpose of developing diagnostic reference levels (DRLs) for radiation dose optimisation. The study was conducted in three radiology departments with CT centres in Northern Nigeria. Data were collected from 54 consenting adult participants ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncv188

    authors: Garba I,Engel-Hills P,Davidson F,Tabari AM

    更新日期:2015-07-01 00:00:00

  • SOIL 222Rn CONCENTRATION, CO2 AND CH4 FLUX MEASUREMENTS AROUND THE JWALAMUKHI AREA OF NORTH-WEST HIMALAYAS, INDIA.

    abstract::Soil 222Rn concentration, CO2 and CH4 flux measurements were conducted around the Jwalamukhi area of North-West Himalayas, India. During this study, around 37 soil gas points and flux measurements were taken with the aim to assure the suitability of this method in the study of fault zones. For this purpose, RAD 7 (Dur...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw071

    authors: Kumar A,Walia V,Yang TF,Fu CC,Singh S,Bajwa BS,Arora V

    更新日期:2016-10-01 00:00:00

  • Spatial distribution of indoor radon in Triveneto (Northern Italy): a geostatistical approach.

    abstract::The study of spatial distribution of the indoor radon has assumed in the last years a lot of interest. The geostatistical techniques turn out to be particularly promising. The present work presents the results of a study where around 4000 indoor radon data from Veneto, Friuli Venezia-Giulia and Alto Adige, collected d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp252

    authors: Bertolo A,Bigliotto C,Giovani C,Garavaglia M,Spinella M,Verdi L,Pegoretti S

    更新日期:2009-12-01 00:00:00

  • Neutron spectra unfolding in Bonner spheres spectrometry using neural networks.

    abstract::The neural network method has been used for the unfolding of neutron spectra in neutron spectrometry by Bonner spheres. A back propagation algorithm was used for training of neural networks. 4 mm x 4 mm bare LiI (Eu) and in a polyethylene sphere set: 2, 3, 4, 5, 6, 7, 8, 10, 12, 18 inch diameter have been used for unf...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006158

    authors: Kardan MR,Setayeshi S,Koohi-Fayegh R,Ghiassi-Nejad M

    更新日期:2003-01-01 00:00:00

  • THE CONVERSION OF EXPOSURES DUE TO RADON INTO THE EFFECTIVE DOSE TAKING INTO ACCOUNT THE EQUIVALENCE OF RISKS FROM SHORT- AND LONG-TERM EXPOSURES.

    abstract::The theoretical basis for comparing risks from short- and long-term exposures is developed aiming at implementing long-term exposures into a unique and consistent system of radiation protection. Based on system-analytical considerations, the equivalence of population-averaged risk rates due to prolonged exposures and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv553

    authors: Beck TR

    更新日期:2016-12-01 00:00:00

  • On the equivalence of propane-based tissue-equivalent gas and liquid water with respect to the ionisation-yield formation by electrons and alpha-particles.

    abstract::One encouraging way, at present, to put the investigation of ionisation-yield formation in sub-cellular structures or, at least, in nanometric volumes of liquid water on an experimental basis is the use of highly sophisticated counters filled with gases at low operating pressure to simulate target volumes a few nm in ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006818

    authors: Grosswendt B

    更新日期:2002-01-01 00:00:00

  • QUADOS intercomparison: a summary of photon and charged particle problems.

    abstract::QUADOS, a Concerted Action of the European Commission, has promoted an intercomparison aimed at evaluating the use of computational codes for dosimetry in radiation protection and medical physics. This intercomparison was open to all users of radiation transport codes. Eight problems were selected for their relevance ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci197

    authors: Gualdrini G,Agosteo S,Ménard S,Price RA,Chartier JL,Grosswendt B,Kodeli I,Leuthold GP,Siebert BR,Tagziria H,Tanner RJ,Terrissol M,Zankl M

    更新日期:2005-01-01 00:00:00

  • Monte carlo study of MOSFET packaging, optimised for improved energy response: single MOSFET filtration.

    abstract::Monte Carlo simulations of the energy response of a conventionally packaged single metal-oxide field effect transistors (MOSFET) detector were performed with the goal of improving MOSFET energy dependence for personal accident or military dosimetry. The MOSFET detector packaging was optimised. Two different 'drop-in' ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq144

    authors: Othman MA,Cutajar DL,Hardcastle N,Guatelli S,Rosenfeld AB

    更新日期:2010-09-01 00:00:00

  • Levels of depleted uranium in Kosovo soils.

    abstract::The United Nations Environment Programme (UNEP) has performed a field survey at 11 sites located in Kosovo, where depleted uranium (DU) ammunitions were used by the North Atlantic Treaty Organization (NATO) during the last Balkans conflict (1999). Soil sampling was performed to assess the spread of DU ground contamina...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006679

    authors: Sansone U,Stellato L,Jia G,Rosamilia S,Gaudino S,Barbizzi S,Belli M

    更新日期:2001-01-01 00:00:00

  • Radical distributions in ammonium tartrate single crystals exposed to photon and neutron beams.

    abstract::The radiation therapy carried out by means of heavy charged particles (such as carbon ions) and neutrons is rapidly becoming widespread worldwide. The success of these radiation therapies relies on the high density of energy released by these particles or by secondary particles produced after primary interaction with ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu033

    authors: Marrale M,Longo A,Barbon A,Brustolon M,Brai M

    更新日期:2014-10-01 00:00:00

  • Optically stimulated luminescent glass optical fibre dosemeter.

    abstract::An optical fibre radiation dosemeter has been developed that utilises optically stimulated luminescence and scintillation to provide independent, remote, real-time dose measurements. The radiation sensitive element consists of a 1 mm long, 0.4 mm diameter piece of copper-ion-doped fused quartz that is attached to a 1 ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005974

    authors: Huston AL,Justus BL,Falkenstein PL,Miller RW,Ning H,Altemus R

    更新日期:2002-01-01 00:00:00

  • AMANDE: a new facility for monoenergetic neutron fields production between 2 keV and 20 MeV.

    abstract::The variation of the response of the instruments with the neutron energy has to be determined in well-characterized monoenergetic neutron fields. The AMANDE facility will deliver such neutron fields between 2 keV and 20 MeV in an experimental hall designed with metallic walls for neutron scattering minimisation. The n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch185

    authors: Gressier V,Guerre-Chaley JF,Lacoste V,Lebreton L,Pelcot G,Pochat JL,Bolognese-Milstajn T,Champion D

    更新日期:2004-01-01 00:00:00

  • PARALLELISATION OF THE MODEL-BASED ITERATIVE RECONSTRUCTION ALGORITHM DIRA.

    abstract::New paradigms for parallel programming have been devised to simplify software development on multi-core processors and many-core graphical processing units (GPU). Despite their obvious benefits, the parallelisation of existing computer programs is not an easy task. In this work, the use of the Open Multiprocessing (Op...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv430

    authors: Örtenberg A,Magnusson M,Sandborg M,Alm Carlsson G,Malusek A

    更新日期:2016-06-01 00:00:00

  • Determination of natural radioactivity in building materials used in Tunisian dwellings by gamma ray spectrometry.

    abstract::The radioisotopic content of 17 samples of natural and manufactured building materials collected in Tunisia have been analysed by using gamma spectrometry. From the measured gamma ray spectra, activity concentrations are determined for (232)Th, (226)Ra, (235)U and (40)K. The total effective dose and the activity conce...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch489

    authors: Hizem N,Ben Fredj A,Ghedira L

    更新日期:2005-01-01 00:00:00

  • Benchmarking of MCNP for calculating dose rates at an interim storage facility for nuclear waste.

    abstract::During the operation of research facilities at Research Centre Jülich, Germany, nuclear waste is stored in drums and other vessels in an interim storage building on-site, which has a concrete shielding at the side walls. Owing to the lack of a well-defined source, measured gamma spectra were unfolded to determine the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci185

    authors: Heuel-Fabianek B,Hille R

    更新日期:2005-01-01 00:00:00

  • Criteria and suspension levels in diagnostic radiology.

    abstract::The EC (European Council) Directive on radiation protection of patients requires that criteria for acceptability of equipment in diagnostic radiology, nuclear medicine and radiotherapy be established throughout the member states. This study reviews the background to this requirement and to its implementation in practi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncs295

    authors: Malone J,Baldelli P,Balter S,Bischof N,Bosmans H,Dowling A,Edyvean S,Gallagher A,Faulkner K,Horner K,Malone L,Mclean ID,O'Connor U,Schreiner A,Vassileva J,Vano E,Zoetelief J

    更新日期:2013-02-01 00:00:00

  • Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses.

    abstract::The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdome...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu321

    authors: Suliman II,Khamis HM,Ombada TH,Alzimami K,Alkhorayef M,Sulieman A

    更新日期:2015-12-01 00:00:00

  • TOWARDS A PERSONALISED AND INTERACTIVE ASSESSMENT OF OCCUPATIONAL EXPOSURE TO MAGNETIC FIELD DURING DAILY ROUTINE IN MAGNETIC RESONANCE.

    abstract::Magnetic resonance imaging (MRI) is one of the most common sources of electromagnetic (EM) fields as a diagnostic technique widely used in medicine. MRI staff during the working day is constantly exposed to static and spatially heterogeneous magnetic field. Also, moving around the MRI room to perform their functions, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy114

    authors: Hartwig V,Virgili G,Ferrante Vero LF,De Marchi D,Landini L,Giovannetti G

    更新日期:2018-12-01 00:00:00

  • Soil gas radon measurements in a region of the Bohemian Massif: investigations in the framework of an Austrian pilot study.

    abstract::Soil gas radon measurements are carried out in a pilot study in three municipalities in Upper Austria. The selected municipalities are characterised by a high radon potential. Sixty measuring sites--well distributed over the region and over the different geological areas--were selected. Additionally, the permeability ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr089

    authors: Seidel C,Baumgartner A,Ringer W,Gräser J,Friedmann H,Kaineder H,Maringer FJ

    更新日期:2011-05-01 00:00:00

  • Effective dose assessment for workers in caves in the Czech Republic: experiments with passive radon detectors.

    abstract::The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN system consists of a plastic chamber that is conically cylindrical in shape and about 0.5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn118

    authors: Thinová L,Burian I

    更新日期:2008-01-01 00:00:00

  • Development of a voxel phantom of Japanese adult male in upright posture.

    abstract::A Japanese voxel phantom in upright posture, JM2, has been developed on the basis of CT images of a healthy Japanese adult male. Body characteristics of JM2 were compared with those of the supine voxel phantom, JM, previously developed using CT images of the same person. Differences were found in the shapes of the spi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm272

    authors: Sato K,Noguchi H,Endo A,Emoto Y,Koga S,Saito K

    更新日期:2007-01-01 00:00:00