Individual monitoring in mixed neutron/photon fields using a single silicon detector.

Abstract:

:A device based on a single silicon detector of special converter/detector design optimised for the determination of the neutron dose equivalent is also used for the determination of the photon dose equivalent. While the neutron dose is determined on the basis of signals corresponding to energy depositions above 1.5 MeV, depositions between 80 keV and 150 keV are used for the photon dose equivalent. In this way, a photon response is achieved which varies by less than 30% in the energy region from 80 keV to 7 MeV for irradiation at normal incidence and at 60 degrees to the normal. The lower limit of detection is of the order of 1 microSv. Neutrons contribute to the photon reading by less than 2% in mixed fields with a comparable dose equivalent from neutrons and photons.

journal_name

Radiat Prot Dosimetry

authors

Luszik-Bhadra M

doi

10.1093/oxfordjournals.rpd.a005962

keywords:

subject

Has Abstract

pub_date

2002-01-01 00:00:00

pages

179-82

issue

1-4

eissn

0144-8420

issn

1742-3406

journal_volume

101

pub_type

杂志文章
  • Cellular signal transduction events as a function of linear energy transfer (LET).

    abstract::In order to obtain a deeper insight into the molecular mechanism controlling the cellular response to high-linear energy transfer (LET) radiation, the number and size of pATM (S1981) and gamma-H2AX foci were compared in cultures of diploid human fibroblasts after exposure to charged particles of varying species, energ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm086

    authors: Fürweger C,Hajek M,Vana N,Kodym R,Okayasu R

    更新日期:2007-01-01 00:00:00

  • DETERMINATION OF THE TOTAL EFFECTIVE DOSE OF EXTERNAL AND INTERNAL EXPOSURE BY DIFFERENT IONIZING RADIATION SOURCES.

    abstract::The purpose of the research is to develop an integrated technique for determining the effective dose (E) of external and internal exposure by different sources of ionizing radiation. The proposing technique for determining the total effective dose is based on three methods of calculation. The first one is multiplying ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz170

    authors: Kudryashev VA,Kim DS

    更新日期:2019-12-31 00:00:00

  • RADON SURVEY IN SCHOOL AND ESTIMATION OF EFFECTIVE DOSE USING CORRECTED RADON CONCENTRATION.

    abstract::Radon exposure in schools is different from that in dwellings because the residence pattern is very different each other. So, when effective dose is calculated in schools, different approach should be considered from in dwellings. The aim of this study was to estimate actual effective dose due to inhaled radon conside...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx216

    authors: Lee ER,Chang BU,Kim YJ

    更新日期:2018-04-01 00:00:00

  • Discussion on optimisation below dose limit for public using background-cancer-risk-based approach.

    abstract::To improve a radiological protection system, the lower bound of optimisation was discussed using a newly proposed background-cancer-risk-based approach. This approach provides a new finding that the standard deviation of the background cancer risk in Japan is 7.4 × 10(-5) y(-1). If this risk level corresponding to 1σ ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr150

    authors: Hattori T

    更新日期:2011-07-01 00:00:00

  • KINETIC SIMULATIONS OF THE THERMOLUMINESCENCE CHARACTERISTICS OF LiF:Mg, Ti INCORPORATING LOCALISED AND DELOCALISED RECOMBINATION.

    abstract::Kinetic simulations of the thermoluminescence characteristics of LiF:Mg, Ti are reviewed in the framework of conduction band/valence band models. Delocalised recombination models have been mainly applied to the simulation of glow peak shapes, although comparison with experimental data has proven difficult if not impos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa209

    authors: Eliyahu I,Oster L

    更新日期:2021-01-13 00:00:00

  • Determination of committed effective doses to skin due to ²³⁸U, ²³²Th and ²²²Rn from the application of various Moroccan black soap (Saboun Beldi) samples by members of the general public.

    abstract::(238)U, (232)Th, (222)Rn and (220)Rn concentrations were measured inside various Moroccan black soap samples widely used by the Moroccan population in traditional baths (Hammans) by using both CR-39 and LR-115 type II solid state nuclear track detectors. The measured (238)U, (232)Th, (222)Rn and (220)Rn concentrations...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq275

    authors: Misdaq MA,Outeqablit K

    更新日期:2010-12-01 00:00:00

  • Dose surveys and DRLs: critical look and way forward.

    abstract::The main purpose of dose surveys has been to detect and bring down wide variation in radiation doses for any particular radiological examination and to avoid doses that are on higher side. Diagnostic reference levels (DRLs) have been used for over two decades as an aid in this objective. With very limited success that...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv063

    authors: Rehani MM

    更新日期:2015-07-01 00:00:00

  • Nuclear reactions in Monte Carlo codes.

    abstract::The physics foundations of hadronic interactions as implemented in most Monte Carlo codes are presented together with a few practical examples. The description of the relevant physics is presented schematically split into the major steps in order to stress the different approaches required for the full understanding o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006788

    authors: Ferrari A,Sala PR

    更新日期:2002-01-01 00:00:00

  • On the use of LiF TLD-600 in neutron-gamma mixed fields.

    abstract::A new procedure allowing the separate estimation of neutron and gamma dose in mixed radiation fields has been developed in our laboratory. In this communication, a description of the main features of the discrimination procedure and some preliminary results obtained by its use are presented. The procedure is based on ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm210

    authors: Delgado A,Muñiz JL,Gómez Ros JM,Romero AM,Rodríguez R

    更新日期:2007-01-01 00:00:00

  • Low air exchange rate causes high indoor radon concentration in energy-efficient buildings.

    abstract::Since 1995, requirements on energy-efficient building construction were established in Russian Building Codes. In the course of time, utilisation of such technologies became prevailing, especially in multi-storey building construction. According to the results of radon survey in buildings constructed meeting new requi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv319

    authors: Vasilyev AV,Yarmoshenko IV,Zhukovsky MV

    更新日期:2015-06-01 00:00:00

  • Suppression methods of radon emanation from phosphorus fertiliser and diatomaceous earth.

    abstract::The present paper shows methods to suppress radon emanation from artificial porous materials such as phosphorous fertiliser or diatomaceous earth with a small amount of radium. The basic concept of suppression is making the radon emanation mechanism 'null', which comes from the fact that recoil is the main mechanism o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm420

    authors: Sasaki T,Gunji Y,Okuda T

    更新日期:2007-01-01 00:00:00

  • Radiological emergency: Malaysian preparedness and response.

    abstract::Planning and preparation in advance for radiological emergencies can help to minimise potential public health and environmental threats if and when an actual emergency occurs. During the planning process, emergency response organisations think through how they would respond to each type of incident and the resources t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr102

    authors: Yusof MA,Ali HM

    更新日期:2011-07-01 00:00:00

  • Occupational exposure to electromagnetic fields in physiotherapy departments.

    abstract::To assess occupational exposure to electromagnetic fields, 11 microwave (MW), 4 short-wave diathermy and 15 magneto therapy devices were analysed in eight physiotherapy departments. Measurements taken at consoles and environmental mapping showed values above European Directive 2004/40/EC and ACGIH exposure limits at a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm309

    authors: Maccà I,Scapellato ML,Carrieri M,Pasqua di Bisceglie A,Saia B,Bartolucci GB

    更新日期:2008-01-01 00:00:00

  • Measurement of neutron inelastic scattering cross sections for 52Cr from threshold up to 18 MeV.

    abstract::The powerful white neutron spectrum from Gelina is used for the investigation of gamma ray production cross sections in the reaction 52Cr(n,n'gamma)52Cr. The gamma rays from the inelastic process are detected with two large volume HPGe detectors placed at 110 degrees and 150 degrees with respect to the beam direction....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci199

    authors: Mihailescu LC,Borcea C,Plompen AJ

    更新日期:2005-01-01 00:00:00

  • Risk management policies and practices regarding radio frequency electromagnetic fields: results from a WHO survey.

    abstract::This study aims to describe current risk management practices and policies across the world in relation to personal exposures from devices emitting radiofrequency fields, environmental exposures from fixed installations and exposures in the work environment. Data from 86 countries representing all WHO regions were col...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu324

    authors: Dhungel A,Zmirou-Navier D,van Deventer E

    更新日期:2015-04-01 00:00:00

  • Radical distributions in ammonium tartrate single crystals exposed to photon and neutron beams.

    abstract::The radiation therapy carried out by means of heavy charged particles (such as carbon ions) and neutrons is rapidly becoming widespread worldwide. The success of these radiation therapies relies on the high density of energy released by these particles or by secondary particles produced after primary interaction with ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu033

    authors: Marrale M,Longo A,Barbon A,Brustolon M,Brai M

    更新日期:2014-10-01 00:00:00

  • New diagnostic reference level for full-field digital mammography units.

    abstract::The diagnostic reference level (DRL) has generally been defined as the 75th percentile of the distributions of mean doses observed on a sample of standard-sized patients, but for mammography, the 95th percentile has been used. In this study, the 75th and 95th percentiles are estimated for 26 full-field digital mammogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct136

    authors: Hauge IH,Bredholt K,Olerud HM

    更新日期:2013-12-01 00:00:00

  • Variation in indoor thoron levels in Mexico City dwellings.

    abstract::This paper presents the results obtained for thoron concentration in 50 single-family dwellings in normal occupancy conditions (open house conditions), measured by a passive electret system (type E-PERM, SSTB configuration) in a 2001-2002 monitoring survey in the Metropolitan Zone of Mexico City. The results show the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch371

    authors: Martinez T,Navarrete M,Gonzalez P,Ramírez A

    更新日期:2004-01-01 00:00:00

  • FLEXIBLE, WIRELESS, INDUCTIVELY COUPLED SURFACE COIL RESONATOR FOR EPR TOOTH DOSIMETRY.

    abstract::Managing radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation relies on the availability of biodosimetry to assess whether individuals need to be triaged for care. Electron Paramagnetic Resonance (EPR) tooth dosimetry is a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw153

    authors: Schreiber W,Petryakov SV,Kmiec MM,Feldman MA,Meaney PM,Wood VA,Boyle HK,Flood AB,Williams BB,Swartz HM

    更新日期:2016-12-01 00:00:00

  • A comparative study of quality control in diagnostic radiology.

    abstract::The main objective of this comparative study was to evaluate the national quality assurance program for X-ray diagnostic radiology in Syrian governmental hospitals. Two periods were covered in this study, the first period was from 1986 to 1998 (52 hospitals and 149 X-ray machines were considered) and the second period...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn096

    authors: Kharita MH,Khedr MS,Wannus KM

    更新日期:2008-01-01 00:00:00

  • Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

    abstract::The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci627

    authors: Kim JL,Lee JI,Ji YH,Kim BH,Kim JS,Chang SY

    更新日期:2006-01-01 00:00:00

  • Biomarkers specific to densely-ionising (high LET) radiations.

    abstract::There have been several suggestions of biomarkers that are specific to high LET radiation. Such a biomarker could significantly increase the power of epidemiological studies of individuals exposed to densely-ionising radiations such as alpha particles (e.g. radon, plutonium workers, individuals exposed to depleted ura...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006640

    authors: Brenner DJ,Okladnikova N,Hande P,Burak L,Geard CR,Azizova T

    更新日期:2001-01-01 00:00:00

  • EXPOSURE ASSESSMENT OF PORTABLE WIRELESS DEVICES ABOVE 6 GHz.

    abstract::The emerging 5 G wireless devices working at frequencies above 6 GHz are expected to have antenna arrays formed by dipoles, slots, patches or their combination. At lower frequencies, the accepted criteria for exposure compliance is stated in terms of specific absorption rate. IEEE and ICNIRP are adopting epithelial or...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy177

    authors: Carrasco E,Colombi D,Foster KR,Ziskin M,Balzano Q

    更新日期:2019-06-01 00:00:00

  • Entrances skin dose distribution maps for interventional neuroradiological procedures: a preliminary study.

    abstract::Dose estimation in interventional neuroradiology can be useful to limit skin radiation injuries. The purpose of this study was to evaluate the role of entrance skin dose (ESD) maps in planning exposure condition optimisation. Thirteen cerebral angiography and five embolisation procedures were monitored, measuring ESD,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci759

    authors: Rampado O,Ropolo R

    更新日期:2005-01-01 00:00:00

  • Optically stimulated luminescence signals of polymineral fine grains in the JSC Mars-1 soil simulant sample.

    abstract::The results of various experiments which characterise the optically stimulated luminescence (OSL) signals from polymineral fine grains of a Martian soil simulant sample (JSC Mars-1) are presented. The blue-green stimulated luminescence signal has greater thermal stability than the infrared stimulated luminescence sign...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005994

    authors: Banerjee D,Blair M,Lepper K,McKeever SW

    更新日期:2002-01-01 00:00:00

  • SAR distribution in human beings when using body-worn RF transmitters.

    abstract::This study analyzes the exposure of the human torso to electromagnetic fields caused by wireless body-mounted or handheld devices. Because of the frequency and distance ranges from 30-5800 MHz and 10 to 200 mm, respectively, both near-field and far-field effects are considered. A generic body model and simulations of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm377

    authors: Christ A,Samaras T,Neufeld E,Klingenböck A,Kuster N

    更新日期:2007-01-01 00:00:00

  • Induced radioactivity in and around high-energy particle accelerators.

    abstract::Particle accelerators and their surroundings are locations of residual radioactivity production that is induced by the interaction of high-energy particles with matter. This paper gives an overview of the principles of activation caused at proton accelerators, which are the main machines operated at Conseil Européen p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr245

    authors: Vincke H,Theis C,Roesler S

    更新日期:2011-07-01 00:00:00

  • Determination of radon concentration levels in well water in Konya, Turkey.

    abstract::Radon ((222)Rn) measurements were undertaken in 16 samples of well water representing different depths and different types of aquifers found at the city centre of Konya, Central Turkey. The radon activity concentrations of the well water samples collected in the spring and summer seasons of 2012 were measured by using...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct099

    authors: Erdogan M,Eren N,Demirel S,Zedef V

    更新日期:2013-10-01 00:00:00

  • Minimising activity and dose with enhanced image quality by radiopharmaceutical administrations.

    abstract::Owing to the introduction of new diagnostic procedures, such as computed tomography (CT), positron emission tomography (PET) and single photon emission computed tomography (SPECT), the individual dose caused by medical exposures has grown rapidly in the last years. This is especially a subject to radiation protection ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq104

    authors: Hoeschen C,Mattsson S,Cantone MC,Mikuz M,Lacasta C,Ebel G,Clinthorne N,Giussani A

    更新日期:2010-04-01 00:00:00

  • A software tool for increased efficiency in observer performance studies in radiology.

    abstract::Observer performance studies are time-consuming tasks, both for the participating observers and for the scientists collecting and analysing the data. A possible way to optimise such studies is to perform them in a completely digital environment. A software tool-ViewDEX (Viewer for Digital Evaluation of X-ray images)-h...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch550

    authors: Börjesson S,Håkansson M,Båth M,Kheddache S,Svensson S,Tingberg A,Grahn A,Ruschin M,Hemdal B,Mattsson S,Månsson LG

    更新日期:2005-01-01 00:00:00