DETERMINATION OF THE TOTAL EFFECTIVE DOSE OF EXTERNAL AND INTERNAL EXPOSURE BY DIFFERENT IONIZING RADIATION SOURCES.

Abstract:

:The purpose of the research is to develop an integrated technique for determining the effective dose (E) of external and internal exposure by different sources of ionizing radiation. The proposing technique for determining the total effective dose is based on three methods of calculation. The first one is multiplying the value of the individual dose equivalent $H_{p}(10)$ by the factor of 0.642 to account for radiation shielding by various organs and tissues and its backscattering. The second method is multiplying $H_{p}(10)$ by the conversion factor of air kerma in free air in a plate phantom, depending on the photon energy. The third method is multiplying $H_{p}(10)$ by the sum of the radiosensitivity coefficients of various organs and tissues. As a result of research, a complex method was developed for determining the total effective dose, composed of doses of cosmic radiation, external gamma-, beta- and neutron radiation, internal exposure from radionuclides, including CDP of radon and thoron, entering the body through the organs of digestion and respiration. The proposed technique for determining the total effective dose allows one to take into account the comprehensive effect of ionizing radiation sources on a person and to obtain a more accurate measure of radiation risk than the existing methods provide.

journal_name

Radiat Prot Dosimetry

authors

Kudryashev VA,Kim DS

doi

10.1093/rpd/ncz170

subject

Has Abstract

pub_date

2019-12-31 00:00:00

pages

129-137

issue

1

eissn

0144-8420

issn

1742-3406

pii

5566649

journal_volume

187

pub_type

杂志文章
  • Liulin-type spectrometry-dosimetry instruments.

    abstract::The main purpose of Liulin-type spectrometry-dosimetry instruments (LSDIs) is cosmic radiation monitoring at the workplaces. An LSDI functionally is a low mass, low power consumption or battery-operated dosemeter. LSDIs were calibrated in a wide range of radiation fields, including radiation sources, proton and heavy-...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq506

    authors: Dachev Ts,Dimitrov P,Tomov B,Matviichuk Y,Spurny F,Ploc O,Brabcova K,Jadrnickova I

    更新日期:2011-03-01 00:00:00

  • EVALUATION OF NEUTRON SCATTERING CORRECTION USING THE SEMI-EMPIRICAL METHOD AND THE SHADOW-CONE METHOD FOR THE NEUTRON FIELD OF THE KOREA ATOMIC ENERGY RESEARCH INSTITUTE.

    abstract::When neutron survey metres are calibrated in neutron fields, the results for room- and air-scattered neutrons vary according to the distance from the source and the size, shape and construction of the neutron calibration room. ISO 8529-2 recommends four approaches for correcting these effects: the shadow-cone method, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx219

    authors: Lee SK,Kim SI,Lee J,Chang I,Kim JL,Kim H,Kim MC,Kim BH

    更新日期:2018-08-01 00:00:00

  • EPR DOSIMETRY STUDY FOR POPULATION RESIDING IN THE VICINITY OF FALLOUT TRACE FOR NUCLEAR TEST ON 7 AUGUST 1962.

    abstract::The method of electron paramagnetic resonance (EPR) dosimetry using extracted teeth has been applied to human tooth enamel to obtain individual absorbed doses of residents of settlements in the vicinity of the central axis of radioactive fallout trace from the contaminating surface nuclear test on 7 August 1962. Most ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw178

    authors: Zhumadilov KS,Ivannikov AI,Stepanenko VF,Toyoda S,Skvortsov VG,Hoshi M

    更新日期:2016-12-01 00:00:00

  • Radiation protection culture: a global challenge.

    abstract::The central motto 'Radiation Protection Culture-A Global Challenge' of the fourth European IRPA Congress is discussed on the basis of the IRPA Guiding Principles Establishing a Radiation Protection Culture and the contributions presented in the plenary sessions of the conference. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu325

    authors: Michel R,Henrichs K,Wernli C

    更新日期:2015-04-01 00:00:00

  • Occupational radiation protection of health workers in imaging.

    abstract::Occupational radiological protection (RP) is still a challenge in several clinical practices. ICRP has included specific recommendations and advice for occupational protection in most of the documents published in recent years and its current programme of work includes the preparation of documents with specific conten...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu354

    authors: Vano E

    更新日期:2015-04-01 00:00:00

  • Application of a Ge semi-conductor detector to whole-body counter.

    abstract::To calibrate a whole-body counter, it is necessary to find a determination method for peak efficiencies of detectors used in the whole-body counter. For this purpose, peak efficiencies of a Ge semiconductor detector for point and volume sources were evaluated in the photon energy range 60-1836 keV by Monte Carlo simul...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006283

    authors: Kinase S,Noguchi H,Nakamura T

    更新日期:2003-01-01 00:00:00

  • STUDY OF 222RN CONTINUOUS MONITORING TIME SERIES AND DOSE ASSESSMENT IN SIX EUROPEAN CAVES.

    abstract::The present work aims to assess the effective doses from long-term continual radon monitoring in six European caves (Slovenia, Slovakia and the Czech Republic), including influencing environmental factors. Caves are important radiation protection subjects because of elevated radon activity concentration (~kBq/m3), mos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa159

    authors: Ambrosino F,Thinová L,Briestenský M,Sabbarese C

    更新日期:2020-11-27 00:00:00

  • Can default ICRP f1 values be applied to determine radiation dose from the intake of diet-incorporated thorium?

    abstract::Data on the daily urinary excretion of thorium (Th) was obtained from 15 non-exposed adult German subjects. A radiochemical neutron activation analysis method was developed and standardised especially for this purpose. The daily urinary excretion of 232Th was found to be in the range 1.9-14.9 microBq d(-1) with a mean...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch482

    authors: Höllriegl V,Li WB,Oeh U,Röhmuss M,Roth P

    更新日期:2005-01-01 00:00:00

  • MICRODOSIMETRIC SIMULATIONS OF CARBON IONS USING THE MONTE CARLO CODE FLUKA.

    abstract::Therapeutic carbon ion beams produce a complex and variable radiation field that changes along the penetration depth due to the high density of energy loss along the particle track together with the secondary particles produced by nuclear fragmentation reactions. An accurate physical characterisation of such complex m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx201

    authors: Chiriotti S,Conte V,Colautti P,Selva A,Mairani A

    更新日期:2018-08-01 00:00:00

  • Modelling the 137Cs ingestion dose from consumption of marine fish in Hong Kong.

    abstract::This paper presents a compartmental model for estimating the ingestion dose, due to 137Cs, arising from the consumption of marine fish in Hong Kong. 137Cs is one of the more important radionuclides released in routine liquid effluents discharged from the Guangdong Nuclear Power Station at Daya Bay, which began commerc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006710

    authors: Poon CB,Au SM

    更新日期:2002-01-01 00:00:00

  • Radiation doses potentially received on-board aeroplanes during recent solar particle events.

    abstract::Because the doses received on-board aeroplanes are now monitored to fulfil legal requirements in some countries, including the European Community, the models to calculate doses received during solar events have left their purely academic status to become a part of operational systems as well. The present work consider...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci356

    authors: Lantos P

    更新日期:2006-01-01 00:00:00

  • Long-term monitoring of radiation exposure of employees in the department of nuclear medicine (Szczecin, Poland) in the years 1991-2007.

    abstract::Occupational radiation exposure is a hazard that should be avoided or at least minimised. This study aimed to evaluate the radiation exposure of nuclear medicine department employees monitored during the 1991-2007 period, and to investigate the relationship between the annual effective doses of the personnel and the n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq117

    authors: Piwowarska-Bilska H,Birkenfeld B,Listewnik M,Zorga P

    更新日期:2010-08-01 00:00:00

  • Levels of depleted uranium in Kosovo soils.

    abstract::The United Nations Environment Programme (UNEP) has performed a field survey at 11 sites located in Kosovo, where depleted uranium (DU) ammunitions were used by the North Atlantic Treaty Organization (NATO) during the last Balkans conflict (1999). Soil sampling was performed to assess the spread of DU ground contamina...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006679

    authors: Sansone U,Stellato L,Jia G,Rosamilia S,Gaudino S,Barbizzi S,Belli M

    更新日期:2001-01-01 00:00:00

  • Patient dose in neonatal units.

    abstract::Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is therefore the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn237

    authors: Smans K,Struelens L,Smet M,Bosmans H,Vanhavere F

    更新日期:2008-01-01 00:00:00

  • Non-radiation induced signals in TL dosimetry.

    abstract::One source of background signals, which are non-radiation related, is the reader system and it includes dark current, external contaminants and electronic spikes. These factors can induce signals equivalent to several hundredths of mSv. Mostly, the effects are minimised by proper design of the TLD reader, but some eff...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006064

    authors: German U,Weinstein M

    更新日期:2002-01-01 00:00:00

  • PUBLIC HEALTH ENGLAND-CENTRE FOR RADIATION, CHEMICAL AND ENVIRONMENTAL HAZARDS (PHE-CRCE) EXTERNAL EXPERT EXPERIENCE IN THE JOINT EXTERNAL EVALUATION (JEE) MISSION FOR THE RADIATION EMERGENCIES TECHNICAL AREA.

    abstract::From August 2016 to June 2017, the Public Health England-Centre for Radiation Chemical and Environmental Hazards (PHE-CRCE), collaborating centre of the WHO, through its Radiation Hazards and Emergencies Department Emergency Response Group has successfully supported five WHO Joint External Evaluation (JEE) missions in...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy142

    authors: de Ruvo A,Cox D

    更新日期:2018-12-01 00:00:00

  • A comparison of the response of PADC neutron dosemeters in high-energy neutron fields.

    abstract::Within the framework of the EURADOS Working Group 11, a comparison of passive neutron dosemeters in high-energy neutron fields was organised in 2011. The aim of the exercise was to evaluate the response of poly-allyl-glycol-carbonate neutron dosemeters from various European dosimetry laboratories to high-energy neutro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct275

    authors: Trompier F,Boschung M,Buffler A,Domingo C,Cale E,Chevallier MA,Esposito A,Ferrarini M,Geduld DR,Hager L,Hohmann E,Mayer S,Musso A,Romero-Esposito M,Röttger S,Smit FD,Sashala Naik A,Tanner R,Wissmann F,Caresana M

    更新日期:2014-10-01 00:00:00

  • MEASUREMENTS OF RADIATION EXPOSURE OF RADIOGRAPHY STUDENTS DURING THEIR CLINICAL TRAINING USING THERMOLUMINESCENT DOSIMETRY.

    abstract::Radiation dose monitoring for radiography students during clinical training is necessary to demonstrate the extent of radiation protection issues present, as well as to instill in them an awareness of safe practices that they will carry with them throughout their careers. The study assess the radiation dose incurred b...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx261

    authors: Abuzaid MM,Elshami W,Steelman C

    更新日期:2018-05-01 00:00:00

  • Worldwide bioassay data resources for plutonium/americium internal dosimetry studies.

    abstract::Biokinetic models are the scientific underpinning of internal dosimetry and depend, ultimately, for their scientific validation on comparisons with human bioassay data. Three significant plutonium/americium bioassay databases, known to the authors, are described: (1) Sellafield, (2) Los Alamos and (3) the United State...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm164

    authors: Miller G,Riddell AE,Filipy R,Bertelli L,Little T,Guilmette R

    更新日期:2007-01-01 00:00:00

  • Shielding Effect of Lead Glasses on Radiologists' Eye Lens Exposure in Interventional Procedures.

    abstract::To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw098

    authors: Hu P,Kong Y,Chen B,Liu Q,Zhuo W,Liu H

    更新日期:2017-04-20 00:00:00

  • THE CONVERSION OF EXPOSURES DUE TO RADON INTO THE EFFECTIVE DOSE TAKING INTO ACCOUNT THE EQUIVALENCE OF RISKS FROM SHORT- AND LONG-TERM EXPOSURES.

    abstract::The theoretical basis for comparing risks from short- and long-term exposures is developed aiming at implementing long-term exposures into a unique and consistent system of radiation protection. Based on system-analytical considerations, the equivalence of population-averaged risk rates due to prolonged exposures and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv553

    authors: Beck TR

    更新日期:2016-12-01 00:00:00

  • Absorbed dose rate estimation for protons, leptons and helium observed with AMS01 experiment in low earth orbit during STS-91 mission.

    abstract::The Alpha Magnetic Spectrometer (AMS01), a high-sensitivity particle spectrometer, was successfully flown for 10 d in June 1998 (STS91) in the orbit of the International Space Station (51.7 degrees, -380 km). A high-statistics dataset of galactic cosmic rays were measured as a function of geomagnetic latitude, includi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci071

    authors: Ionica M,Alpat B,Ambrosi G,Battiston R,Bertucci B,Burger WJ,Caraffini D,Cecchi C,Dinu N,Esposito G,Fiandrini E,Ionica R,Menichelli M,Pauluzzi M,Zuccon P

    更新日期:2005-01-01 00:00:00

  • Measuring aerosols generated inside armoured vehicles perforated by depleted uranium ammunition.

    abstract::In response to questions raised after the Gulf War about the health significance of exposure to depleted uranium (DU), the US Department of Defense initiated a study designed to provide an improved scientific basis for assessment of possible health effects on soldiers in vehicles struck by these munitions. As part of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006215

    authors: Parkhurst MA

    更新日期:2003-01-01 00:00:00

  • Mechanistic modelling of genetic and epigenetic events in radiation carcinogenesis.

    abstract::Methodological problems arise on the way of radiation carcinogenesis modelling with the incorporation of radiobiological and cancer biology mechanistic data. The results of biophysical modelling of different endpoints [DNA DSB induction, repair, chromosome aberrations (CA) and cell proliferation] are presented and app...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl463

    authors: Andreev SG,Eidelman YA,Salnikov IV,Khvostunov IK

    更新日期:2006-01-01 00:00:00

  • Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter.

    abstract::Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 microm thick CVD diamon...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci667

    authors: Preciado-Flores S,Schreck M,Meléndrez R,Chernov V,Bernal R,Cruz-Vázquez C,Cruz-Zaragoza E,Barboza-Flores M

    更新日期:2006-01-01 00:00:00

  • A recoil-proton spectrometer based on a p-i-n diode implementing pulse-shape discrimination.

    abstract::A recoil-proton spectrometer was created by coupling a p-i-n diode with a polyethylene converter. The maximum detectable energy, imposed by the thickness of the totally depleted layer, is approximately 6 MeV. The minimum detectable energy is limited by the contribution of secondary electrons generated by photons in th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch237

    authors: Agosteo S,D'Angelo G,Fazzi A,Foglio Para A,Pola A,Ventura L,Zotto P

    更新日期:2004-01-01 00:00:00

  • Detection of primary and secondary cosmic ray particles aboard the ISS using SSNTD stacks.

    abstract::To study the radiation environment inside the International Space Station, solid state nuclear track detector stacks were used. Within the BRADOS experiments, Phase 1, seven stacks were exposed at different locations of the Russian segment 'Zvezda' for 248 days in 2001. It was supposed that the radiation field inside ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci673

    authors: Pálfalvi JK,Akatov Y,Szabó J,Sajó-Bohus L,Eördögh I

    更新日期:2006-01-01 00:00:00

  • CAPABILITIES OF THE ARADOS-WG03 REGIONAL NETWORK FOR LARGE-SCALE RADIOLOGICAL AND NUCLEAR EMERGENCY SITUATIONS IN ASIA.

    abstract::In 2015, the Asian Radiation Dosimetry Group established a regional network of biological dosimetry laboratories known as the ARADOS-WG03 (Working Group 03; Biological Dosimetry). A survey was conducted in 2017 to evaluate the capabilities and capacities of the participating laboratories for emergency preparedness and...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy279

    authors: Jang S,Suto Y,Liu J,Liu Q,Zuo Y,Duy PN,Miura T,Abe Y,Hamasaki K,Suzuki K,Kodama S

    更新日期:2019-12-31 00:00:00

  • The Mayak Worker Dosimetry System (MWDS-2013): Estimate of Pu Content in Lungs and Thoracic Lymph Nodes From a Limited Set of Organ Autopsy Samples.

    abstract::A method to estimate plutonium content from a limited number of samples of lungs and pulmonary lymph nodes obtained at autopsies of former Mayak Production Association (MPA) workers is described. Historically from one to five samples of lung lobes and one to three respiratory lymph nodes (bronchopulmonary, tracheobron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw218

    authors: Sokolova AB,Suslova KG,Miller SC

    更新日期:2017-11-01 00:00:00

  • Assessment of natural radioactivity and the associated hazards in Iranian cement.

    abstract::This paper presents the finding of a study undertaken to determine natural radioactivity and associated hazards in local types of cement in Iran. A total of 42 samples were collected from various manufacturers and suppliers and analysed using a shielded HPGe gamma-ray spectrometer. The specific activities of 232Th, 22...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl549

    authors: Fathivand AA,Amidi J

    更新日期:2007-01-01 00:00:00