30-y follow-up of a Pu/Am inhalation case.

Abstract:

:In 1983, a young man inhaled accidentally a large amount of plutonium and americium. This case was carefully followed until 2013. Since no decorporation measures had been taken, the undisturbed metabolism of Pu and Am can be derived from the data. First objective was to determine the amount of inhaled radionuclides and to estimate committed effective dose. In vivo and excretion measurements started immediately after the inhalation, and for quality assurance, all types of measurements were performed by different labs in Europe and the USA. After dose assessment by various international groups were completed, the measurements were continued to produce scientific data for model validation. The data have been analysed here to estimate lung absorption parameter values for the inhaled plutonium and americium oxide using the proposed new ICRP Human Respiratory Tract Model. As supplement to the biokinetic modelling, biological data from three different cytogenetic markers have been added. The estimated committed effective dose is in the order of 1 Sv. The subject is 30 y after the inhalation, of good health, according to a recent medical check-up.

journal_name

Radiat Prot Dosimetry

authors

Wernli C,Eikenberg J,Marzocchi O,Breustedt B,Oestreicher U,Romm H,Gregoratto D,Marsh J

doi

10.1093/rpd/ncu342

subject

Has Abstract

pub_date

2015-04-01 00:00:00

pages

57-64

issue

1-2

eissn

0144-8420

issn

1742-3406

pii

ncu342

journal_volume

164

pub_type

杂志文章
  • CONCEPTS OF OPERATIONS FOR A US DOSIMETRY AND BIODOSIMETRY NETWORK.

    abstract::The USA must be prepared to provide a prompt, coordinated and integrated response for radiation dose and injury assessment for suspected radiation exposure, whether it involves isolated cases or mass casualties. Dose estimation for radiation accidents typically necessitates a multiple parameter diagnostics approach th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy294

    authors: Dainiak N,Albanese J,Kaushik M,Balajee AS,Romanyukha A,Sharp TJ,Blakely WF

    更新日期:2019-12-31 00:00:00

  • Comparison of synchrotron radiation calculations between analytical codes (STAC8, photon) and Monte Carlo codes (FLUKA, EGS4).

    abstract::STAC8 is a significant improvement upon its predecessor PHOTON and is a valuable analytical code for quick and conservative beamline shielding designs for synchrotron radiation (SR) facilities. In order to check the applicability, accuracy and limitations of STAC8, studies were conducted to compare the results of STAC...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci207

    authors: Liu JC,Fasso A,Prinz A,Rokni S,Asano Y

    更新日期:2005-01-01 00:00:00

  • Digital dual-parameter data acquisition for SP2 hydrogen-filled proportional counters.

    abstract::Hydrogen-filled proportional counters perform well as neutron spectrometers in the energy region from a few tens of keV up to ∼1.5 MeV. Unfortunately, gamma rays also generate signals in these detectors. It is possible in principle to distinguish the two types of event via the rise time of their respective signal puls...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct262

    authors: Hawkes NP,Roberts NJ

    更新日期:2014-10-01 00:00:00

  • The Mayak Worker Dosimetry System (MWDS-2013): Estimate of Pu Content in Lungs and Thoracic Lymph Nodes From a Limited Set of Organ Autopsy Samples.

    abstract::A method to estimate plutonium content from a limited number of samples of lungs and pulmonary lymph nodes obtained at autopsies of former Mayak Production Association (MPA) workers is described. Historically from one to five samples of lung lobes and one to three respiratory lymph nodes (bronchopulmonary, tracheobron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw218

    authors: Sokolova AB,Suslova KG,Miller SC

    更新日期:2017-11-01 00:00:00

  • OCCUPATIONAL EXPOSURE TO RADON IN DIFFERENT KINDS OF NON-URANIUM MINES.

    abstract::For more accurate assessments of the occupational exposure to radon for miners, the individual monitoring was conducted by using an improved passive integrating (222)Rn monitor. A total of 120 miners in 3 different kinds of mines were monitored throughout a year. The results showed that the individual exposure to rado...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw026

    authors: Fan D,Zhuo W,Zhang Y

    更新日期:2016-09-01 00:00:00

  • A fast response and gamma-insensitive neutron detector based on parallel-plate avalanche counter.

    abstract::The use of the parallel-plate avalanche counter for slow-neutron counting is described. The choice of a suitable neutron converter is discussed on the basis of Monte Carlo simulation, and some experimental results are shown. Excellent gamma-insensitivity, high rate capability, possibility of construction in large sens...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncm462

    authors: Nakhostin M,Baba M,Itoga T,Oishi T,Unno Y,Kamada S,Okuji T

    更新日期:2008-01-01 00:00:00

  • PARALLELISATION OF THE MODEL-BASED ITERATIVE RECONSTRUCTION ALGORITHM DIRA.

    abstract::New paradigms for parallel programming have been devised to simplify software development on multi-core processors and many-core graphical processing units (GPU). Despite their obvious benefits, the parallelisation of existing computer programs is not an easy task. In this work, the use of the Open Multiprocessing (Op...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv430

    authors: Örtenberg A,Magnusson M,Sandborg M,Alm Carlsson G,Malusek A

    更新日期:2016-06-01 00:00:00

  • Internal dosimetry verification and validation database.

    abstract::Simulated-data internal dosimetry cases for use in intercomparison exercises or as a software verification and validation tool have been published on the internet (www.lanl.gov/bayesian/software Bayesian software package II). A user may validate their internal dosimetry code or method using this simulated bioassay dat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm470

    authors: Miller G,Bertelli L,Little T,Guilmette RA

    更新日期:2007-01-01 00:00:00

  • In situ occupational and general public exposure to VHF/UHF transmission for air traffic communication.

    abstract::Occupational and general public exposure due to very high frequency (VHF)/ultra high frequency (UHF) transmission centres for verbal communication for air traffic control is investigated in situ for the first time. These systems are used for communication with aircraft, resulting in different human exposure from that ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs016

    authors: Joseph W,Goeminne F,Verloock L,Vermeeren G,Martens L

    更新日期:2012-09-01 00:00:00

  • Analysis of computational problems expressing the overall uncertainties: photons, neutrons and electrons.

    abstract::In the frame of the EU Coordination Action CONRAD (coordinated network for radiation dosimetry), WP4 was dedicated to work on computational dosimetry with an action entitled 'Uncertainty assessment in computational dosimetry: an intercomparison of approaches'. Participants attempted one or more of eight problems. This...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn221

    authors: de Carlan L,Price R,Chartier JL,Kodeli I,Siebert B,Henninger J,Posselt J,Gualdrini G,Agosteo S,Bedogni R,Bordy JM,Cassette P,Ferrari P,Gomez Ros JM,Grosswendt B,Lacoste V,Pola A,Rollet S,Schultz F,Simakov SP,Tanne

    更新日期:2008-01-01 00:00:00

  • Contribution of different foodstuffs to the internal exposure of rural inhabitants in Russia after the Chernobyl accident.

    abstract::In a large village, Veprin of the Bryansk region of Russia contaminated with radionuclides as a result of the Chernobyl accident, 137Cs concentration in food products of agricultural produce and natural origin was regularly measured, local inhabitants were polled on the composition of their diet, and the 137Cs content...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006445

    authors: Travnikova IG,Bruk GJ,Shutov VN,Bazjukin AB,Balonov MI,Rahola T,Tillander M

    更新日期:2001-01-01 00:00:00

  • Application of a CZT detector to in situ environmental radioactivity measurement in the Fukushima area.

    abstract::Instead of conventional Ge semiconductor detectors and NaI(Tl) scintillation spectrometers, an application of a CdZnTe semiconductor (CZT) whose crystal has the dimension of 1 cm cubic to the in situ environmental radioactivity measurement was attempted in deeply affected areas in Fukushima region. Results of depositi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv277

    authors: Kowatari M,Kubota T,Shibahara Y,Fujii T,Fukutani S,Takamiya K,Mizuno S,Yamana H

    更新日期:2015-11-01 00:00:00

  • Radioactive waste management and decommissioning of accelerator facilities.

    abstract::During the operation of high-energy accelerators, the interaction of radiation with matter can lead to the activation of the machine components and of the surrounding infrastructures. As a result of maintenance operation and during decommissioning of the installation, considerable amounts of radioactive waste are evac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp196

    authors: Ulrici L,Magistris M

    更新日期:2009-11-01 00:00:00

  • INITIAL EVALUATION OF INDIVIDUAL DOSES IN THE EARLY PHASE OF A NUCLEAR REACTOR ACCIDENT BASED ON IN-VIVO MONITORING DATA AND SIMULATED RADIOLOGICAL CONSEQUENCES.

    abstract::In the early phase of a nuclear reactor accident, in-vivo monitoring of impacted population would be highly useful to detect potential contamination during the passage of the cloud and to estimate the dose from inhalation of measured radionuclides. However, it would be important to take into account other exposure com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy277

    authors: Challeton-de Vathaire C,Quentric E,Didier D,Blanchardon E,Davesne E,Rannou A,Agarande M,Renaud-Salis V,Franck D

    更新日期:2019-11-30 00:00:00

  • A follow-up study on indoor 222Rn, 220Rn their decay product concentrations in a mineralised zone of Himachal Pradesh, India.

    abstract::A follow-up study was taken up in a mineralised zone situated in Hamirpur district, Himachal Pradesh, India, to investigate high values of radon concentrations reported in past studies as well to update the old radon data based on bare SSNTD technique. In the present investigation, the concentrations of indoor radon, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv367

    authors: Bajwa BS,Singh P,Singh P,Saini K,Singh S,Sahoo BK,Sapra BK

    更新日期:2016-03-01 00:00:00

  • Survey of patient dose in computed tomography in Syria 2009.

    abstract::The radiation doses to patient in computed tomography (CT) in Syria have been investigated and compared with similar studies in different countries. This work surveyed 30 CT scanners from six different manufacturers distributed all over Syria. Some of the results in this paper were part of a project launched by the In...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq155

    authors: Kharita MH,Khazzam S

    更新日期:2010-09-01 00:00:00

  • Studies of patient doses in interventional radiological examinations.

    abstract::In Russia, especially in big cities like St. Petersburg, the annual number of interventional radiological (IR) examinations for both diagnostic and treatment purposes is increasing continuously. However, IR examinations might involve high patient doses and even the risk of skin injures that should be prevented. In thi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncq021

    authors: Sarycheva S,Golikov V,Kalnicky S

    更新日期:2010-04-01 00:00:00

  • PRACTICAL METHODS FOR INTERNAL DOSE ASSESSMENT FOR RADIOIODINE INTAKE AFTER THYROID BLOCKING: CLASSIFICATION OF DEGREE OF BLOCKAGE AND DETERMINATION OF INSENSITIVE MEASUREMENT POINT.

    abstract::Iodine thyroid blocking (ITB) suppresses the uptake of iodine to the thyroid and reduces internal doses after radioiodine intake; however, its disturbance of thyroid biokinetics causes considerable uncertainty in the use of dosimetric data intended for assessment of unblocked normal thyroid. To more accurately assess ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz139

    authors: Kwon TE,Park M,Jung GH,Chung Y,Ha WH,Jin YW

    更新日期:2019-12-31 00:00:00

  • TOWARDS A PERSONALISED AND INTERACTIVE ASSESSMENT OF OCCUPATIONAL EXPOSURE TO MAGNETIC FIELD DURING DAILY ROUTINE IN MAGNETIC RESONANCE.

    abstract::Magnetic resonance imaging (MRI) is one of the most common sources of electromagnetic (EM) fields as a diagnostic technique widely used in medicine. MRI staff during the working day is constantly exposed to static and spatially heterogeneous magnetic field. Also, moving around the MRI room to perform their functions, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy114

    authors: Hartwig V,Virgili G,Ferrante Vero LF,De Marchi D,Landini L,Giovannetti G

    更新日期:2018-12-01 00:00:00

  • A fast and simple approach for the estimation of a radiological source from localised measurements after the explosion of a radiological dispersal device.

    abstract::After an explosion of a radiological dispersal device, decision-makers need to implement countermeasures as soon as possible to minimise the radiation-induced risks to the population. In this work, the authors present a tool, which can help providing information about the approximate size of source term and radioactiv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct263

    authors: Urso L,Kaiser JC,Woda C,Helebrant J,Hulka J,Kuca P,Prouza Z

    更新日期:2014-03-01 00:00:00

  • A co-ordinated network for radiation dosimetry (CONRAD): an overview.

    abstract::The European Radiation Dosimetry Group (EURADOS) carried out a co-ordinated action, supported within the 6th Framework Programme of the European Commission entitled 'A Co-ordinated Network for Radiation Dosimetry (CONRAD)'. The project, executed from January 2005 to March 2008, yielded a large number of scientific res...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn209

    authors: Schuhmacher H,Fantuzzi E

    更新日期:2008-01-01 00:00:00

  • Modelling the energy-loss mechanism of charged particles in organic solids.

    abstract::The present study examines the energy-loss mechanism of charged particles in organic solids as determined by the inelastic interactions with the electronic sub-system of the target. The dielectric approach was applied to non-conducting valence electrons while an appropriate binary collision theory was used for core-el...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005836

    authors: Emfietzoglou D

    更新日期:2002-01-01 00:00:00

  • Radon in earthquake prediction research.

    abstract::The observation of anomalies in the radon concentration in soil gas and ground water before earthquakes initiated systematic investigations on earthquake precursor phenomena. The question what is needed for a meaningful earthquake prediction as well as what types of precursory effects can be expected is shortly discus...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr229

    authors: Friedmann H

    更新日期:2012-04-01 00:00:00

  • Measurements of radon gas concentrations in dwellings of Al-Madinah Al-Munawarah province in Saudi Arabia.

    abstract::Indoor radon concentration levels in a large number of dwellings in Al-Madinah Al-Munawarah Province have been measured. Al-Madinah Al-Munawarah is in the western region of Saudi Arabia. It is the second holiest city in Islam after Mecca, because it is the burial place of the Islamic Prophet Muhammad. The city was div...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct219

    authors: Mohamed RI,Alfull ZZ,Dawood ND

    更新日期:2014-01-01 00:00:00

  • The natural radioactivity contents in feed coals from the lignite-fired power plants in Western Anatolia, Turkey.

    abstract::Lignite burning is one of the sources of technologically enhanced exposure to humans from natural radionuclides. In the preliminary study, part of the survey, the activity concentrations of (226)Ra, (232)Th and (40)K in 112 samples of feed lignites from seven lignite-fired power plants in Western Anatolia (Seyitömer, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq210

    authors: Cam NF,Yaprak G,Eren E

    更新日期:2010-12-01 00:00:00

  • Detection system built from commercial integrated circuits for real-time measurement of radiation dose and quality using the variance method.

    abstract::A small, specialised amplifier using commercial integrated circuits (ICs) was developed to measure radiation dose and quality in real time using a microdosimetric ion chamber and the variance method. The charges from a microdosimetric ion chamber, operated in the current mode, were repeatedly collected for a fixed per...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm231

    authors: Hsu WH,Braby LA,Reece WD

    更新日期:2008-01-01 00:00:00

  • Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters.

    abstract::Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolní Rozínka' at Rozná, Czech Republic. The sampling flow...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm455

    authors: Becková V,Malátová I

    更新日期:2008-01-01 00:00:00

  • Effective dose to a patient undergoing coronary angiography.

    abstract::Detailed data relating to patient dose have been acquired for 18, randomly chosen, patients undergoing coronary angiographies. During the procedure, dose-area product (DAP), kV and beam collimation were recorded for each projection. Total DAP, fluoroscopy time and number of cine frames were also noted. Patient effecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006466

    authors: Lobotessi H,Karoussou A,Neofotistou V,Louisi A,Tsapaki V

    更新日期:2001-01-01 00:00:00

  • RADIOLOGICAL HAZARD INDICES OF GRANITIC ROCKS USED FOR THE CONSTRUCTION OF BUILDINGS FROM NUBA MOUNTAINS SUDAN.

    abstract::This study was conducted to assess the level of radioactivity and the radiation hazards associated with granite rocks used for construction of buildings. The measurement of radioactivity content of the rock samples was performed with gamma-spectrometry equipped with Nal (TI) detector. From the results obtained in this...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx295

    authors: Fadol N,Idriss H,Salih I,Ragab NA,Osman S,Sam AK

    更新日期:2018-06-01 00:00:00

  • Spot measurements of intermediate frequency electric fields in the vicinity of compact fluorescent lamps.

    abstract::Starting in 2009, certain types of incandescent light bulbs will be withdrawn from the market in the European Union and elsewhere. However, compact fluorescent lamps that are among the candidates to replace them produce intermediate frequency electric fields (EFs) much higher than any other device or appliance previou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq276

    authors: Bakos J,Nagy N,Juhász P,Thuróczy G

    更新日期:2010-12-01 00:00:00