Comparison of synchrotron radiation calculations between analytical codes (STAC8, photon) and Monte Carlo codes (FLUKA, EGS4).

Abstract:

:STAC8 is a significant improvement upon its predecessor PHOTON and is a valuable analytical code for quick and conservative beamline shielding designs for synchrotron radiation (SR) facilities. In order to check the applicability, accuracy and limitations of STAC8, studies were conducted to compare the results of STAC8 with those of PHOTON with calculations using the FLUKA and EGS4 Monte Carlo codes. Doses and spectra for scattered SR in a few beam-target-shield geometries were calculated, with and without photon linear polarisation effects. Areas for expanding the STAC8 capabilities, for example, features of the mirror-reflected lights and double-Compton light calculations and the use of monochromatic light have been identified. Some of these features have been implemented and benchmarked against Monte Carlo calculations. Reasonable agreements were found between the STAC8 and Monte Carlo calculations.

journal_name

Radiat Prot Dosimetry

authors

Liu JC,Fasso A,Prinz A,Rokni S,Asano Y

doi

10.1093/rpd/nci207

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

658-61

issue

1-4 Pt 2

eissn

0144-8420

issn

1742-3406

journal_volume

116

pub_type

杂志文章
  • Minimising activity and dose with enhanced image quality by radiopharmaceutical administrations.

    abstract::Owing to the introduction of new diagnostic procedures, such as computed tomography (CT), positron emission tomography (PET) and single photon emission computed tomography (SPECT), the individual dose caused by medical exposures has grown rapidly in the last years. This is especially a subject to radiation protection ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq104

    authors: Hoeschen C,Mattsson S,Cantone MC,Mikuz M,Lacasta C,Ebel G,Clinthorne N,Giussani A

    更新日期:2010-04-01 00:00:00

  • Monte Carlo calculations for efficiency calibration of a whole-body monitor using BOMAB phantoms of different sizes.

    abstract::Internal contamination due to high-energy photon (HEP) emitters is assessed using a scanning bed whole-body monitor housed in a steel room at the Bhabha Atomic Research Centre (BARC). The monitor consists of a (203 mm diameter × 102 mm thickness) NaI(Tl) detector and is calibrated using a Reference BOMAB phantom repre...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr203

    authors: Bhati S,Patni HK,Ghare VP,Singh IS,Nadar MY

    更新日期:2012-03-01 00:00:00

  • A combination study of indoor radon and in situ gamma spectrometry measurements in Greek dwellings.

    abstract::The aim of the present study was to investigate of a possible correlation between indoor radon and indoor gamma dose rates deduced by in situ gamma spectrometry measurements by using a portable HPGe detector. Indoor radon and high resolution in situ gamma spectrometry measurements were performed in 60 apartments in Th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006154

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2003-01-01 00:00:00

  • DEVELOPMENT OF A NATIONAL EMERGENCY PLAN FOR MEDICAL DIAGNOSTICS AND THERAPY OF DETERMINISTIC EFFECTS AFTER RADIATION ACCIDENTS.

    abstract::The focus of nuclear emergency planning in Austria has been so far on mitigating effects of widespread contamination (e.g. after NPP accidents); however, these plans did not contain provisions on the medical management of an acute radiation syndrome. To close this gap, a 'Medical Radiation Emergency Plan' was created ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw210

    authors: Ziegler A

    更新日期:2016-09-01 00:00:00

  • Considerations and preliminary design of patient exposure registry.

    abstract::To aid in protecting patients from unnecessary exposures and to reduce radiation burdens to the public, a system for tracking a patient's medical exposure history and related radiation doses would be a useful tool. A patient-centred exposure registry, the Patient Exposure Registry (PER), is a mechanism that provides t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq280

    authors: Chen J,Moir D,Cornett J

    更新日期:2010-12-01 00:00:00

  • Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED project.

    abstract::The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in differen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq508

    authors: Domienik J,Brodecki M,Carinou E,Donadille L,Jankowski J,Koukorava C,Krim S,Nikodemova D,Ruiz-Lopez N,Sans-Mercé M,Struelens L,Vanhavere F

    更新日期:2011-03-01 00:00:00

  • A survey on uncertainty in bioassay measurements carried out within the OMINEX project.

    abstract::One of the topics covered by the OMINEX (Optimisation of Monitoring for Internal Exposure) project was to look at the bioassay measurements performed in the European laboratories. Questionnaires on bioassay measurements by alpha spectrometry or inductively coupled plasma-mass spectrometry (ICP-MS) were sent to Europea...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006261

    authors: Hurtgen C,Cossonnet C

    更新日期:2003-01-01 00:00:00

  • Dosimetry on sub-cellular level for intracellular incorporated auger-electron-emitting radionuclides: a comparison of Monte Carlo simulations and analytic calculations.

    abstract::A quantitative dosimetric comparison was performed between Monte Carlo (MC) simulations and analytic calculations at the (sub) cellular level (V79 cells) for four nucleus-incorporated radiochemicals ((125)I/(123)I/(77)Br-UdR and A (125)IP) and two radiochemicals that localised mainly in the cytoplasm of cells ((125)I-...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq293

    authors: Bousis C

    更新日期:2011-01-01 00:00:00

  • Full spectrum analysis in environmental monitoring.

    abstract::In environmental radiation monitoring, the time-variable natural gamma radiation background complicates the nuclide identification and analysis of a gamma spectrum. A full spectrum analysis based on the noise adjusted singular value decomposition method for the description of the time-variable background and adjustmen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu144

    authors: Reinhardt S

    更新日期:2014-08-01 00:00:00

  • Radon in the Exhaled Air of Patients in Radon Therapy.

    abstract::In the Gastein valley, numerous facilities use radon for the treatment of various diseases either by exposure to radon in air or in radon rich thermal water. In this study, six test persons were exposed to radon thermal water in a bathtub and the time-dependent radon activity concentration in the exhaled air was recor...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx153

    authors: Lettner H,Hubmer A,Hofmann W,Landrichinger J,Gaisberger M,Winkler-Heil R

    更新日期:2017-11-01 00:00:00

  • Lithium fluoride: from LiF:Mg,Ti to LiF:Mg,Cu,P.

    abstract::Differences and similarities between LiF-based LiF:Mg,Ti and LiF:Mg,Cu,P are discussed, with respect to their dosimetric properties--sensitivity, non-linearity of dose response and heavy charged particle efficiency, as related to the concentration and the individual role of the Mg, Ti, Cu and P dopants. To study furth...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005847

    authors: Bilski P

    更新日期:2002-01-01 00:00:00

  • PATIENT DOSE ASSESSMENT AFTER INTERVENTIONAL CARDIOLOGY PROCEDURES: A MULTI-CENTRIC APPROACH TO TRIGGER OPTIMISATION.

    abstract::As the number and complexity of fluoroscopically guided interventions increase, a serious effort has to be put on the optimisation of the X-ray dose delivered to the patient. In order to set up this optimisation process, the clinical practice for a given cardiology centre has to be analysed with relevant statistical p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncv525

    authors: Ryckx N,Goy JJ,Stauffer JC,Verdun FR

    更新日期:2016-06-01 00:00:00

  • Luminescence dosimetry using building materials and personal objects.

    abstract::There is a growing public awareness of the risk of accidental radiation exposure due to ageing nuclear power installations, illegal dumping of nuclear waste and terrorist activities, and of the consequential health risks to populations in addition to social and economic disturbance extending beyond national boundaries...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci699

    authors: Göksu HY,Bailiff IK

    更新日期:2006-01-01 00:00:00

  • Effective dose to a patient undergoing coronary angiography.

    abstract::Detailed data relating to patient dose have been acquired for 18, randomly chosen, patients undergoing coronary angiographies. During the procedure, dose-area product (DAP), kV and beam collimation were recorded for each projection. Total DAP, fluoroscopy time and number of cine frames were also noted. Patient effecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006466

    authors: Lobotessi H,Karoussou A,Neofotistou V,Louisi A,Tsapaki V

    更新日期:2001-01-01 00:00:00

  • Evaluation of radionuclide concentrations and associated radiological hazard indexes in building materials used in Egypt.

    abstract::Radionuclide concentrations of ²²⁶Ra, ²³²Th and ⁴⁰K in different types of building materials used in Egypt were measured using gamma-ray spectroscopy. The results showed relatively moderate radionuclide concentrations for all samples except granite, which showed extremely high concentrations of 78.75 ± 2.36, 2.82 ± 0....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct129

    authors: Hassan NM,Mansour NA,Fayez-Hassan M

    更新日期:2013-12-01 00:00:00

  • The measurements of thoron, radon and their decay products thanks to Pinocchio, Tengu and Trolls.

    abstract::In the present paper, the long noses of Pinocchio, Tengu and Trolls are used to measure, respectively, radon, thoron, and their decay products both by track-etch detectors and by Geiger-Müller (G-M) counters. Just recently, four new passive samplers (termed quatrefoil) have been developed which greatly simplify the de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq248

    authors: Tommasino L,Tokonami S,Tommasino PM

    更新日期:2010-10-01 00:00:00

  • Population dose due to building materials in Ibadan, Nigeria.

    abstract::The natural radionuclide contents of some concrete building blocks randomly sampled in the city of Ibadan have been determined using NaI(Tl) gamma ray spectrometry. The radionuclides 226Ra, 232Th and 40K were determined with city mean specific activities 47 +/- 21 Bq.kg-1, 52 +/- 21 Bq.kg-1, and 352 +/- 222 Bq.kg-1, r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006527

    authors: Farai IP,Ademola JA

    更新日期:2001-01-01 00:00:00

  • Population dose in the vicinity of closed Hungarian uranium mine.

    abstract::In order to determine the exposure to natural sources of radiation for people in the vicinity of remediated Hungarian uranium mine regional surveys were carried out. The surveys evaluated indoor radon concentrations and outdoor and indoor external gamma dose rates. Radon concentration has been measured with nuclear et...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci363

    authors: Gorjánácz Z,Várhegyi A,Kovács T,Somlai J

    更新日期:2006-01-01 00:00:00

  • Magnetic field tracking with MCNP5.

    abstract::With the introduction of continuous-energy heavy charged particle transport in MCNP5, the need for tracking charged particles in a magnetic field becomes increasingly important. Two methods for including magnetic field effects on charged particles are included in the proton transport version of the code. The first tec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci048

    authors: Bul JS,Hughes HG,Walstrom PL,Zumbro JD,Mokhov NV

    更新日期:2005-01-01 00:00:00

  • Calibration of EPR signal dose response of tooth enamel to photons: experiment and Monte Carlo simulation.

    abstract::The experimental energy dependence of the electron paramagnetic resonance (EPR) radiation-induced signal at irradiation by photons in the energy range of 13 keV-1.25 MeV was analysed in terms of the absorbed dose in human tooth enamel. The latter was calculated using a Monte Carlo simulation of the photon and electron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch040

    authors: Ivannikov AI,Tikunov DD,Borysheva NB,Trompier F,Skvortsov VG,Stepanenko VF,Hoshi M

    更新日期:2004-01-01 00:00:00

  • EPR properties of intact and deproteinated dentin.

    abstract::The effect of sample preparation on dentin electron paramagnetic resonance (EPR) spectra was investigated. The analysis was performed on dentin samples prepared by pure mechanical treatment or by an alkaline deproteination method. It was observed that (1) mechanical treatment induces both stable and transient signals,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci631

    authors: Fattibene P,Carosi A,De Coste V,Onori S

    更新日期:2006-01-01 00:00:00

  • Dose assessment from activated sodium within a body in criticality accidents.

    abstract::Some data were derived using recent sophisticated methods to rapidly convert specific activity of induced 24Na to average dose over a whole body in criticality accidents. Monte Carlo calculations using the MCNP-4B code were performed to study energy spectra of neutrons and gamma rays for some criticality systems with ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006350

    authors: Takahashi F,Endo A,Yamaguchi Y

    更新日期:2003-01-01 00:00:00

  • Set-up of a passive Bonner sphere system for neutron spectrometry at mixed fields with predominant photon component based on activation detector.

    abstract::A passive Bonner sphere system (BSS), based on thermal neutron activation detectors, was developed to perform neutron spectrometry in pulsed and very intense (n-gamma) fields with predominant photon component, as those produced by high energy (>10 MV) medical linear electron accelerators. In this paper, a description ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm070

    authors: Amgarou K,Lacoste V,Muller H,Fernández F

    更新日期:2007-01-01 00:00:00

  • BASELINE STUDIES ON RADIONUCLIDE CONCENTRATION IN FOOD MATERIALS AND ESTIMATION OF THE COMMITTED RADIATION DOSE AROUND THE PHOSPHATE INDUSTRIAL AREA OF SOUTH TUNISIA.

    abstract::The activity concentration of natural and anthropogenic radionuclides was determined in different vegetable samples, and foods derived from animal origin, from different locations in the four cities of Southern Tunisia, where large-scale phosphate industries are operating. The aim of the studies was to establish a bas...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy208

    authors: Machraoui S,Mohan MP,Naregundi K,Labidi S

    更新日期:2019-08-01 00:00:00

  • OCCUPATIONAL DOSE DURING ADULT INTERVENTIONAL CARDIOLOGY: FIRST VALUES WITH PERSONAL ACTIVE DOSIMETERS IN CHILE.

    abstract::The objective of this article is to present initial occupational dose values using digital active personal dosimeters for medical staff during adult interventional cardiology procedures in a public hospital in Chile. Personal dose equivalent Hp(10) over the lead apron of physician, nurse and radiographer were measured...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy057

    authors: Ubeda C,Morales C,Gutiérrez D,Oliveira M,Manterola C

    更新日期:2018-12-01 00:00:00

  • RADIATION DOSE FROM DENTAL RADIOGRAPHY IN INDONESIA: A FIVE-YEAR SURVEY.

    abstract::Dose metrics on intraoral and panoramic dental radiography were analyzed to preliminarily indicate dose trend of dental radiology equipment in Indonesia. Measurements were performed in 71 healthcare institutions involving a total of 92 dental X-ray devices. Imaging modes are categorized into 'low dose' and 'high dose'...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncy123

    authors: Lubis LE,Bayuadi I,Bayhaqi YA,Ardiansyah F,Setiadi AR,Sugandi RD,Craig LA,Nasir A,Basith RA,Pawiro SA,Soejoko DS

    更新日期:2019-05-01 00:00:00

  • WHO's health risk assessment of ELF fields.

    abstract::The World Health Organization (WHO), the International Commission on Non-Ionizing Radiation Protection (ICNIRP), WHO's scientific collaborating centres (including the UK's National Radiological Protection Board (NRPB)) and over 50 participating Member States are participants of WHO's International EMF Project. As part...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006363

    authors: Repacholi MH

    更新日期:2003-01-01 00:00:00

  • EXPERIMENTAL VALIDATION OF ALGORITHMS USED TO ESTIMATE EFFECTIVE DOSE DURING INTERVENTIONAL RADIOLOGY PROCEDURES.

    abstract::In IR procedures, in order to evaluate the effective dose, the importance of the double dosemeter has been recognised, one worn above and one under the apron. Over the last few decades several algorithms have been developed to combine the readings of the dosemeters, however currently there is no international consensu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz136

    authors: Negri P,Campi F,De Crescenzo S,Garlati L,Tambussi O

    更新日期:2019-12-31 00:00:00

  • CT equipment and performance issues: radiation protection 162.

    abstract::Since the development of the CT scanner in the early 1970s, CT scanner technology has continuously developed through technical advancement, faster computer processing, superior detectors and helical and multi-detector scanning modes. As a result, the scope of clinical examinations has broadened considerably, and in pa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs285

    authors: Edyvean S

    更新日期:2013-02-01 00:00:00

  • RESULTS AND DISCUSSION ON JAPANESE PUBLIC OPINION SURVEYS (2006-17) ABOUT NUCLEAR AND RADIATION APPLICATIONS.

    abstract::Public opinion on the application of nuclear technology and radiation could change when a nuclear related event occurs. Japan Atomic Energy Relations Organization has tracked its variation through a nationwide opinion survey in Japan by almost the same way every year since FY 2006. We can identify a continuous long-te...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz127

    authors: Iimoto T,Takashima R,Kimura H,Kawakami K,Endo H,Yasuda H,Nagata N,Sakai N,Kawasaki Y,Funakoshi M

    更新日期:2019-10-01 00:00:00