OCCUPATIONAL DOSE DURING ADULT INTERVENTIONAL CARDIOLOGY: FIRST VALUES WITH PERSONAL ACTIVE DOSIMETERS IN CHILE.

Abstract:

:The objective of this article is to present initial occupational dose values using digital active personal dosimeters for medical staff during adult interventional cardiology procedures in a public hospital in Chile. Personal dose equivalent Hp(10) over the lead apron of physician, nurse and radiographer were measured during 59 procedures. Mean values of occupational dose Hp(10) per procedure were 47.6, 6.2 and 4.3 μSv for physician, nurse and radiographer, respectively. If no protective tools are used, physician dose can exceed the new eye lens dose limit.

journal_name

Radiat Prot Dosimetry

authors

Ubeda C,Morales C,Gutiérrez D,Oliveira M,Manterola C

doi

10.1093/rpd/ncy057

subject

Has Abstract

pub_date

2018-12-01 00:00:00

pages

294-297

issue

2

eissn

0144-8420

issn

1742-3406

pii

4995043

journal_volume

182

pub_type

杂志文章
  • Population dose due to building materials in Ibadan, Nigeria.

    abstract::The natural radionuclide contents of some concrete building blocks randomly sampled in the city of Ibadan have been determined using NaI(Tl) gamma ray spectrometry. The radionuclides 226Ra, 232Th and 40K were determined with city mean specific activities 47 +/- 21 Bq.kg-1, 52 +/- 21 Bq.kg-1, and 352 +/- 222 Bq.kg-1, r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006527

    authors: Farai IP,Ademola JA

    更新日期:2001-01-01 00:00:00

  • A software tool for increased efficiency in observer performance studies in radiology.

    abstract::Observer performance studies are time-consuming tasks, both for the participating observers and for the scientists collecting and analysing the data. A possible way to optimise such studies is to perform them in a completely digital environment. A software tool-ViewDEX (Viewer for Digital Evaluation of X-ray images)-h...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch550

    authors: Börjesson S,Håkansson M,Båth M,Kheddache S,Svensson S,Tingberg A,Grahn A,Ruschin M,Hemdal B,Mattsson S,Månsson LG

    更新日期:2005-01-01 00:00:00

  • CT equipment and performance issues: radiation protection 162.

    abstract::Since the development of the CT scanner in the early 1970s, CT scanner technology has continuously developed through technical advancement, faster computer processing, superior detectors and helical and multi-detector scanning modes. As a result, the scope of clinical examinations has broadened considerably, and in pa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs285

    authors: Edyvean S

    更新日期:2013-02-01 00:00:00

  • Determination of 137Cs and 60Co pollution in the area of the Laguna Verde Nuclear Power Plant, Mexico.

    abstract::The project 'Radiological Analysis of Environmental Samples in the Gulf of Mexico and the coast of Quintana Roo', had the aim of identifying and quantifying anthropogenic radionuclides in environmental samples consisting of silt, sand and sea water. This paper presents the results of the radiological analysis of these...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv250

    authors: Salas Mar B

    更新日期:2015-11-01 00:00:00

  • Measuring aerosols generated inside armoured vehicles perforated by depleted uranium ammunition.

    abstract::In response to questions raised after the Gulf War about the health significance of exposure to depleted uranium (DU), the US Department of Defense initiated a study designed to provide an improved scientific basis for assessment of possible health effects on soldiers in vehicles struck by these munitions. As part of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006215

    authors: Parkhurst MA

    更新日期:2003-01-01 00:00:00

  • Current status of radiological protection at nuclear power stations in Japan.

    abstract::The radiation dose to workers at nuclear power stations (NPSs) in Japan was drastically reduced between the late-1970s and the early-1990s by continuous dose-reduction programmes. The total collective dose of radiation workers in FY 2008 was 84.04 person Sv, while the average collective dose was 1.5 person Sv per reac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr185

    authors: Suzuki A,Hori S

    更新日期:2011-07-01 00:00:00

  • Measurement of the 250Cf component in a 252Cf neutron source at KRISS.

    abstract::Neutron emission rate measurements have been carried out at the Korea Research Institute of Standards and Science using a manganese sulphate bath system for (252)Cf and (241)Am-Be sources since 2004. The relative measurement method was chosen in 2012, and the neutron emission rates agreed with those by the absolute me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct327

    authors: Kim J,Park H,Choi KO

    更新日期:2014-10-01 00:00:00

  • Application of a Ge semi-conductor detector to whole-body counter.

    abstract::To calibrate a whole-body counter, it is necessary to find a determination method for peak efficiencies of detectors used in the whole-body counter. For this purpose, peak efficiencies of a Ge semiconductor detector for point and volume sources were evaluated in the photon energy range 60-1836 keV by Monte Carlo simul...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006283

    authors: Kinase S,Noguchi H,Nakamura T

    更新日期:2003-01-01 00:00:00

  • How to prepare head tissue-equivalent liquids for SAR calculations, dosimetry and hyperthermia researches at 900 and 1800 MHz GSM frequencies.

    abstract::The potential harmful effect of electromagnetic fields on human health is an important issue that has been widely discussed in the scientific community. The investigation of temperature rise in human body following exposure to electromagnetic fields has been found impractical in many aspects. Therefore, fabrication of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv351

    authors: Sorgucu U,Develi I,Ozen S

    更新日期:2016-03-01 00:00:00

  • EXPERIMENTAL VALIDATION OF ALGORITHMS USED TO ESTIMATE EFFECTIVE DOSE DURING INTERVENTIONAL RADIOLOGY PROCEDURES.

    abstract::In IR procedures, in order to evaluate the effective dose, the importance of the double dosemeter has been recognised, one worn above and one under the apron. Over the last few decades several algorithms have been developed to combine the readings of the dosemeters, however currently there is no international consensu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz136

    authors: Negri P,Campi F,De Crescenzo S,Garlati L,Tambussi O

    更新日期:2019-12-31 00:00:00

  • Radiation-induced micronucleus frequencies in female peripheral blood lymphocytes collected during the first and second half of the menstrual cycle.

    abstract::Biological dosimetry relies on the assessment of dose in peripheral blood lymphocytes (PBL) of a victim. Variability in the individual radiosensitivity of PBL has an impact on the precision of dose estimate and radiation-induced micronuclei show a strong individual variability. A factor which can influence the radiose...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl545

    authors: Krol M,Lankoff A,Buraczewska I,Derezinska E,Wojcik A

    更新日期:2007-01-01 00:00:00

  • Determination of diagnostic reference levels in general radiography in Latin America.

    abstract::The International Atomic Energy Agency (IAEA) through the International Action Plan on Radiation Protection of Patients and the International Commission on Radiological Protection have for some time carried out important efforts to assure that in the medical applications of the ionising radiations, the optimisation of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct069

    authors: Blanco S,Mora P,Almonte N,Benavente T,Benson N,Blanco D,Cárdenas J,Defaz Gómez Y,Edding O,Escobar C,Fonseca M,Gamarra M,García Aguilar J,Khoury HJ,Quintero AR,Roas Zuniga N,Zaire E,Nader A

    更新日期:2013-09-01 00:00:00

  • Shielding design of the ITER NBI duct for nuclear and bremsstrahlung radiation.

    abstract::Three-dimensional Monte Carlo shielding analyses are conducted on the ITER Neutral Beam Injection (NBI) duct for the nuclear and bremsstrahlung radiation. The detailed distribution is evaluated about the nuclear heating rate and surface heat load of the NBI duct wall by the neutron and photon transport calculation. Th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci195

    authors: Sato S,Iida H,Yamauchi M,Nishitani T

    更新日期:2005-01-01 00:00:00

  • Radiation exposure and disease questionnaires of early entrants after the Hiroshima bombing.

    abstract::It is popularly known that people who entered into the ground-zero area shortly after the atomic bombings in Hiroshima and Nagasaki suffered from various syndromes similar to acute radiation effects. External exposures from neutron-induced radionuclides in soil have recently been reassessed based on DS02 calculations ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr370

    authors: Imanaka T,Endo S,Kawano N,Tanaka K

    更新日期:2012-03-01 00:00:00

  • Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters.

    abstract::Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolní Rozínka' at Rozná, Czech Republic. The sampling flow...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm455

    authors: Becková V,Malátová I

    更新日期:2008-01-01 00:00:00

  • Terrestrial gamma radioactivity levels and their corresponding extent exposure of environmental samples from Wadi El Assuity protective area, Assuit, Upper Egypt.

    abstract::Representative environmental samples (sandy soil, limestone, marble and gravels) collected from Wadi El Assuity, protective area, Assuit governorate in Upper Egypt have been investigated radiometrically using NaI (Tl) gamma-ray spectrometer. The specific activity of the radionuclides in Bq kg⁻¹ for soil ranged between...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq425

    authors: El-Taher A

    更新日期:2011-06-01 00:00:00

  • Evaluation of radionuclide concentrations and associated radiological hazard indexes in building materials used in Egypt.

    abstract::Radionuclide concentrations of ²²⁶Ra, ²³²Th and ⁴⁰K in different types of building materials used in Egypt were measured using gamma-ray spectroscopy. The results showed relatively moderate radionuclide concentrations for all samples except granite, which showed extremely high concentrations of 78.75 ± 2.36, 2.82 ± 0....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct129

    authors: Hassan NM,Mansour NA,Fayez-Hassan M

    更新日期:2013-12-01 00:00:00

  • The use of a figure-of-merit (FOM) for optimisation in digital mammography: a literature review.

    abstract::The use of image quality parameters in digital mammography such as contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) has been widespread, with the intention of detector evaluation and/or quantitative evaluation of the system performance. These parameters are useful in en...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncr465

    authors: Borg M,Badr I,Royle GJ

    更新日期:2012-08-01 00:00:00

  • A survey of patient dose and clinical factors in a full-field digital mammography system.

    abstract::In this work, we analyse the dose to 5034 patients (20 137 images) who underwent mammographic examinations with a full-field digital mammography (FFDM) system over a 2-y period. The information relevant to this study has been extracted from the image Digital Imaging and Communications in Medicine (DICOM) headers. Entr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch514

    authors: Morán P,Chevalier M,Ten JI,Fernández Soto JM,Vañó E

    更新日期:2005-01-01 00:00:00

  • Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

    abstract::The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci627

    authors: Kim JL,Lee JI,Ji YH,Kim BH,Kim JS,Chang SY

    更新日期:2006-01-01 00:00:00

  • COMPARISON OF MCNP AND VISIPLAN DOSE-FIELD CALCULATIONS FOR MULTILAYER SHIELDING.

    abstract::An important factor in calculation of quantities describing the radiation situation is the selection of a calculation code. In this article, the radiation situation for selected geometries with multilayer shields was judged. Calculations were carried out using deterministic code VISIPLAN and stochastic code MCNP5. Int...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz224

    authors: Bednár D,Lištjak M,Slimák A,Nečas V

    更新日期:2019-12-31 00:00:00

  • A large-scale measurement, analysis and modelling of electromagnetic radiation levels in the vicinity of GSM/UMTS base stations in an urban area.

    abstract::The present study analyses the electric field radiating from the GSM/UMTS base stations located in central Malatya, a densely populated urban area in Turkey. The authors have conducted both instant and continuous measurements of high-frequency electromagnetic fields throughout their research by using non-ionising radi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv008

    authors: Karadağ T,Yüceer M,Abbasov T

    更新日期:2016-01-01 00:00:00

  • In situ occupational and general public exposure to VHF/UHF transmission for air traffic communication.

    abstract::Occupational and general public exposure due to very high frequency (VHF)/ultra high frequency (UHF) transmission centres for verbal communication for air traffic control is investigated in situ for the first time. These systems are used for communication with aircraft, resulting in different human exposure from that ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs016

    authors: Joseph W,Goeminne F,Verloock L,Vermeeren G,Martens L

    更新日期:2012-09-01 00:00:00

  • Dosimetry of a set-up for the exposure of newborn mice to 2.45-GHZ WiFi frequencies.

    abstract::This work describes the dosimetry of a two waveguide cell system designed to expose newborn mice to electromagnetic fields associated with wireless fidelity signals in the frequency band of 2.45 GHz. The dosimetric characterisation of the exposure system was performed both numerically and experimentally. Specific meas...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq129

    authors: Pinto R,Lopresto V,Galloni P,Marino C,Mancini S,Lodato R,Pioli C,Lovisolo GA

    更新日期:2010-08-01 00:00:00

  • LESSONS LEARNED FROM THE EURADOS SURVEY ON INDIVIDUAL MONITORING DATA AND INTERNAL DOSE ASSESSMENTS OF FOREIGNERS EXPOSED IN JAPAN FOLLOWING THE FUKUSHIMA DAIICHI NPP ACCIDENT.

    abstract::European Radiation Dosimetry Group e.V. (EURADOS) survey on individual monitoring data and dose assessment has been carried out for 550 foreigners returning home after being exposed in Japan to intakes of radionuclides (mainly (131)I, (132)I, (132)Te, (134)Cs and (137)Cs) as a consequence of the Fukushima Daiichi NPP ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv510

    authors: Lopez MA,Fojtik P,Franck D,Osko J,Gerstmann U,Scholl C,Lebacq AL,Breustedt B,Del Risco Norrlid L

    更新日期:2016-09-01 00:00:00

  • Early effects comparison of X-rays delivered at high-dose-rate pulses by a plasma focus device and at low dose rate on human tumour cells.

    abstract::A comparative study has been performed on the effects of high-dose-rate (DR) X-ray beams produced by a plasma focus device (PFMA-3), to exploit its potential medical applications (e.g. radiotherapy), and low-DR X-ray beams produced by a conventional source (XRT). Experiments have been performed at 0.5 and 2 Gy doses o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv163

    authors: Virelli A,Zironi I,Pasi F,Ceccolini E,Nano R,Facoetti A,Gavoçi E,Fiore MR,Rocchi F,Mostacci D,Cucchi G,Castellani G,Sumini M,Orecchia R

    更新日期:2015-09-01 00:00:00

  • Shielding design of a brachytherapy unit at the Korle Bu teaching hospital in Ghana: comparison of theoretical calculations and experimental study.

    abstract::A theoretical study was carried out to re-evaluate the integrity of the biological shielding of (137)Cs brachytherapy unit at the Korle Bu Teaching Hospital, Ghana, and the results were verified by measurement of the dose rates at selected locations. The primary objective was to determine the current state of protecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq001

    authors: Arwui CC,Schandorf C,Nani K,Darko EO,Deatanyah P

    更新日期:2010-06-01 00:00:00

  • Bayesian approach for quantifying the uncertainty of neutron doses derived from spectrometric measurements.

    abstract::Bayesian methods provide a unified framework for combining information in the presence of uncertainty. All uncertainties that enter into the description of a measurement are modelled using probability distributions, and these are handled according to the rules of probability theory, ensuring that the approach is free ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl096

    authors: Reginatto M

    更新日期:2006-01-01 00:00:00

  • Comparison of two JAERI phantoms and the problems discovered.

    abstract::During the course of an intercomparison exercise it was possible to compare two JAERI phantoms with each other by using a multi-energy photon emitting lung set (241Am/152Eu). One belonged to the IAEA (Vienna), the other belonged to the Human Monitoring Laboratory (Ottawa). The intercomparison of the phantoms showed th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006511

    authors: Kramer GH,Hauck BM

    更新日期:2001-01-01 00:00:00

  • Biomarkers specific to densely-ionising (high LET) radiations.

    abstract::There have been several suggestions of biomarkers that are specific to high LET radiation. Such a biomarker could significantly increase the power of epidemiological studies of individuals exposed to densely-ionising radiations such as alpha particles (e.g. radon, plutonium workers, individuals exposed to depleted ura...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006640

    authors: Brenner DJ,Okladnikova N,Hande P,Burak L,Geard CR,Azizova T

    更新日期:2001-01-01 00:00:00