EXPERIMENTAL VALIDATION OF ALGORITHMS USED TO ESTIMATE EFFECTIVE DOSE DURING INTERVENTIONAL RADIOLOGY PROCEDURES.

Abstract:

:In IR procedures, in order to evaluate the effective dose, the importance of the double dosemeter has been recognised, one worn above and one under the apron. Over the last few decades several algorithms have been developed to combine the readings of the dosemeters, however currently there is no international consensus on which is the best one. In this work, eight irradiations, corresponding to typical interventional radiology procedures, were carried out in order to experimentally verify the accuracy of the algorithms. The patient was substituted by solid water-equivalent (RW3) layers, while effective dose to personnel was calculated by TLDs inside the Alderson Rando phantom. The results show that most of the algorithms, with a few exceptions, are too conservative, however there are many factors which can affect their accuracy, so it is impossible to achieve a high level of precision in the evaluation of the effective dose.

journal_name

Radiat Prot Dosimetry

authors

Negri P,Campi F,De Crescenzo S,Garlati L,Tambussi O

doi

10.1093/rpd/ncz136

subject

Has Abstract

pub_date

2019-12-31 00:00:00

pages

42-49

issue

1

eissn

0144-8420

issn

1742-3406

pii

5492618

journal_volume

187

pub_type

杂志文章
  • Validating a MCNPX model of Mg(Ar) and TE(TE) ionisation chambers exposed to 60CO gamma rays.

    abstract::For an accurate determination of the absorbed doses in complex radiation fields (e.g. mixed neutron-gamma fields), a better interpretation of the response of ionisation chambers is required. This study investigates a model of the ionisation chambers using a different approach, analysing the collected charge per minute...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm484

    authors: Roca A,Nievaart VA,Moss RL,Stecher-Rasmussen F,Zamfir NV

    更新日期:2008-01-01 00:00:00

  • STRUCTURAL ANALYSIS OF DNA REPAIR PROTEIN XRCC4 APPLYING CIRCULAR DICHROISM IN AN AQUEOUS SOLUTION.

    abstract::We applied circular dichroism (CD) spectral analysis to obtain the secondary structure of the DNA repair protein XRCC4, with a focus on its C-terminus. Using synchrotron radiation as a light source across a wide range of wavelengths, including vacuum ultraviolet (UV) light from 180 to 200 nm and UV light from 200 to 2...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy275

    authors: Nishikubo K,Izumi Y,Matsumoto Y,Fujii K,Matsuo K,Yokoya A

    更新日期:2019-05-01 00:00:00

  • Biodosimetry using chromosome aberrations in human lymphocytes.

    abstract::In vitro dose-response calibration curves for (60)Co gamma rays have been established for unstable chromosome aberrations in human peripheral blood lymphocytes. The observed dose-response data were fitted to a linear quadratic model. The calibration curve parameters were used to estimate the equivalent whole-body dose...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl109

    authors: Senthamizhchelvan S,Pant GS,Rath GK,Julka PK,Nair O,Joshi RC,Malhotra A,Pandey RM

    更新日期:2007-01-01 00:00:00

  • Fast neutron spectrometry and dosimetry using a spherical moderator with position-sensitive detectors.

    abstract::A neutron spectrometry and dosimetry measurement system has been developed based on a different design of the divided regions for a sphere, with three position-sensitive counters. The characteristics of the measurement system have been investigated in the reference radiation fields of Am-Be and (252)Cf sources. When r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl077

    authors: Li T,Yang L,Ma J,Fang D

    更新日期:2007-01-01 00:00:00

  • Radon in waterworks: dose assessment, analysis of influence parameters and improved methods of measurement.

    abstract::In Austria a comprehensive study on radiation exposure in waterworks was conducted. The aim of this study was to evaluate the risks for the affected employees. On the basis of geographical, geological and hydrological aspects, 21 waterworks were selected. A total of 85 passive short-term measurements and measurements ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu067

    authors: Michael S,Andreas B,Claudia S,Fabian R,Ringer W,Josef MF

    更新日期:2014-07-01 00:00:00

  • Collective effective dose from diagnostic radiology in Ukraine.

    abstract::The frequencies and effective doses for the most common X-ray diagnostic examinations in Ukraine were assessed in the frame of the European Commission (EC) Study on European Population Doses from Medical Exposure (Dose Datamed 2). The average effective doses for all radiographic procedures were estimated using the ODS...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv121

    authors: Stadnyk L,Shalopa O,Nosyk O

    更新日期:2015-07-01 00:00:00

  • A fast and simple approach for the estimation of a radiological source from localised measurements after the explosion of a radiological dispersal device.

    abstract::After an explosion of a radiological dispersal device, decision-makers need to implement countermeasures as soon as possible to minimise the radiation-induced risks to the population. In this work, the authors present a tool, which can help providing information about the approximate size of source term and radioactiv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct263

    authors: Urso L,Kaiser JC,Woda C,Helebrant J,Hulka J,Kuca P,Prouza Z

    更新日期:2014-03-01 00:00:00

  • Improved chelation therapy of intramuscularly deposited thorium by CaDTPA in the rat.

    abstract::Comparative studies on the translocation and retention of intramuscularly (i.m.) injected thorium nitrate (234Th 46 ng + 232Th 5 microg per rat) in solutions of citrate, CaDTPA or citrate + CaDTPA in rats have been conducted. Results showed that only thorium in mixed-ligand solution was entirely translocated from the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006294

    authors: Rencová J,Vlková A,Veselá G

    更新日期:2003-01-01 00:00:00

  • Radon in earthquake prediction research.

    abstract::The observation of anomalies in the radon concentration in soil gas and ground water before earthquakes initiated systematic investigations on earthquake precursor phenomena. The question what is needed for a meaningful earthquake prediction as well as what types of precursory effects can be expected is shortly discus...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr229

    authors: Friedmann H

    更新日期:2012-04-01 00:00:00

  • Mammography dose in relation to body mass index, race, and menopausal status.

    abstract::Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006733

    authors: Schubauer-Berigan MK,Frey GD,Baron L,Hoel DG

    更新日期:2002-01-01 00:00:00

  • Time-integrated monitoring of thoron progeny concentration around closed uranium mine sites in Japan.

    abstract::Thoron progeny concentrations were determined using the time-integrated method around closed uranium mine sites in Japan. Because the time-integrated radon progeny monitor developed by the authors has the function to detect (212)Po, time-integrated monitoring of thoron progeny concentration is also available with the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq242

    authors: Ishimori Y

    更新日期:2010-10-01 00:00:00

  • Screen-film versus digital radiography of sacroiliac joints: evaluation of image quality and dose to patients.

    abstract::The purpose of this paper is to evaluate the image quality and dose to patients in the radiography of sacroiliac joints and to perform a clinical comparative study of digital and conventional screen-film radiography. Routine radiography of sacroiliac joint was performed in 60 patients using digital and screen-film rad...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs315

    authors: Jablanovic D,Ciraj-Bjelac O,Damjanov N,Seric S,Radak-Perovic M,Arandjic D,Maksimovic R

    更新日期:2013-06-01 00:00:00

  • A probabilistic safety analysis of incidents in nuclear research reactors.

    abstract::This work aims to evaluate the potential risks of incidents in nuclear research reactors. For its development, two databases of the International Atomic Energy Agency (IAEA) were used: the Research Reactor Data Base (RRDB) and the Incident Report System for Research Reactor (IRSRR). For this study, the probabilistic s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr387

    authors: Lopes VM,Agostinho Angelo Sordi GM,Moralles M,Filho TM

    更新日期:2012-06-01 00:00:00

  • Shielding Effect of Lead Glasses on Radiologists' Eye Lens Exposure in Interventional Procedures.

    abstract::To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw098

    authors: Hu P,Kong Y,Chen B,Liu Q,Zhuo W,Liu H

    更新日期:2017-04-20 00:00:00

  • CALCULATION OF SKIN DOSE DUE TO BETA CONTAMINATION USING THE NEW QUANTITY OF THE ICRP 116: THE 'LOCAL SKIN DOSE'.

    abstract::Values of the new protection quantity 'Local Skin Dose' LSD, introduced by the International Commission on Radiological Protection (ICRP) Publication 116, were calculated for 134 β- or β+ emitting radionuclides, using the Monte Carlo code MCNP6. Two types of source geometry are considered: a point source and disc-type...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx019

    authors: Bourgois L,Ménard S,Comte N

    更新日期:2017-11-01 00:00:00

  • ESTABLISHMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON PROCEDURES OF COMPUTED TOMOGRAPHY IN YAZD PROVINCE.

    abstract:OBJECTIVE:The aim of this study was to propose first established diagnostic reference levels (DRLs) in computed tomography (CT) for adults, based on volume-averaged CTDI and dose length product (DLP) metrics in Yazd Province. MATERIALS AND METHODS:Six multislice CT scanners located at diverse areas of Yazd Province an...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz279

    authors: Zamani H,Masjedi H,Omidi R,Hosein Zare M

    更新日期:2020-06-13 00:00:00

  • VISUALIZATION OF THE DNA REPAIR PROCESS IN MAMMALIAN CELLS TRANSFECTED WITH EGFP-EXPRESSING PLASMID DNA AFTER EXPOSURE TO X-RAYS IN VITRO.

    abstract::To investigate the repair process of DNA damage induced by ionizing radiation in isolation from various types of cytoplasmic damage, we transfected X-irradiated enhanced green fluorescent protein (EGFP)-expressing plasmid DNA into non-irradiated mammalian cells using lipofectamine. The repair kinetics of the irradiate...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy241

    authors: Nakaue H,Obata Y,Kaminaga K,Akimitsu N,Yokoya A

    更新日期:2019-05-01 00:00:00

  • Environmental gamma dosimetry with OSL of alpha-Al(2)O(3):C for in situ sediment measurements.

    abstract::The physical properties of alpha-Al(2)O(3):C are very similar to that of quartz, which make it an attractive dosimetric material for geological and archaeological dating applications. Storage experiments in an ultra-low-radiation underground environment (UDO at PTB) and gamma-ray spectrometry show that the optically s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq146

    authors: Richter D,Dombrowski H,Neumaier S,Guibert P,Zink AC

    更新日期:2010-09-01 00:00:00

  • One cubic metre NIST traceable radon test chamber.

    abstract::With the availability of the National Institute of Standards and Technology (NIST) Radon Emanation Standard with a content of approximately 5000 Bq of 226Ra, it is possible to build a flow through a practical radon test chamber. A standard glove box with four gloves and a transfer port is used. Air is pumped through a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm430

    authors: Kotrappa P,Stieff F

    更新日期:2008-01-01 00:00:00

  • Use of various microdosimetric models for the prediction of radon induced damage in human lungs.

    abstract::Exposure to radon and radon decay products in some residential areas and at workplaces constitutes one of the greatest risks from natural sources of ionising radiation. Recently, increasing attention has been paid to the precise estimations of this health risk by numerous models. The compartmental model published in I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006173

    authors: Böhm R,Nikodémová D,Holý K

    更新日期:2003-01-01 00:00:00

  • A MULTI-ELEMENT THICK GAS ELECTRON MULTIPLIER-BASED MICRODOSEMETER FOR MEASUREMENT OF NEUTRONS DOSE-EQUIVALENT: A MONTE CARLO STUDY.

    abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx024

    authors: Moslehi A,Raisali G

    更新日期:2017-11-01 00:00:00

  • FEASIBILITY OF DISPLAYED EXPOSURE INDEX IN IEC STANDARD FRAMEWORK AS A DOSE OPTIMISATION TOOL FOR DIGITAL RADIOGRAPHY SYSTEMS.

    abstract::International Electrotechnical Commission (IEC) established the framework for the use of exposure index (EI) for evaluating the exposure conditions with various digital systems. In this study, we investigated the feasibility of EI, as per the IEC, by comparing the EIs obtained through manual calculated and that displa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa052

    authors: Park H,Yoon Y,Tanaka N,Kim J,Kim J,Morishita J

    更新日期:2020-07-17 00:00:00

  • Dosimetry of clinical neutron and proton beams: an overview of recommendations.

    abstract::Neutron therapy beams are obtained by accelerating protons or deuterons on Beryllium. These neutron therapy beams present comparable dosimetric characteristics as those for photon beams obtained with linear accelerators; for instance, the penetration of a p(65)+Be neutron beam is comparable with the penetration of an ...

    journal_title:Radiation protection dosimetry

    pub_type: 指南,杂志文章,实务指引,评审

    doi:10.1093/rpd/nch221

    authors: Vynckier S,International Atomic Energy Agency.,International Commission on Radiation Units and Measurements.

    更新日期:2004-01-01 00:00:00

  • Radioactive waste management and decommissioning of accelerator facilities.

    abstract::During the operation of high-energy accelerators, the interaction of radiation with matter can lead to the activation of the machine components and of the surrounding infrastructures. As a result of maintenance operation and during decommissioning of the installation, considerable amounts of radioactive waste are evac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp196

    authors: Ulrici L,Magistris M

    更新日期:2009-11-01 00:00:00

  • The TRADE experiment: shielding calculations for the building hosting the subcritical system.

    abstract::The TRADE project (TRiga Accelerator Driven Experiment), to be performed at the existing TRIGA reactor at ENEA Casaccia, has been proposed as a validation of the accelerator-driven system (ADS) concept. TRADE will be the first experiment in which the three main components of an ADS--the accelerator, spallation target ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci219

    authors: Burn KW,Carta M,Casalini L,Kadi Y,Monti S,Nava E,Palomba M,Petrovich C,Picardi L,Rubbia C,Troiani F

    更新日期:2005-01-01 00:00:00

  • PARALLELISATION OF THE MODEL-BASED ITERATIVE RECONSTRUCTION ALGORITHM DIRA.

    abstract::New paradigms for parallel programming have been devised to simplify software development on multi-core processors and many-core graphical processing units (GPU). Despite their obvious benefits, the parallelisation of existing computer programs is not an easy task. In this work, the use of the Open Multiprocessing (Op...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv430

    authors: Örtenberg A,Magnusson M,Sandborg M,Alm Carlsson G,Malusek A

    更新日期:2016-06-01 00:00:00

  • Cytogenic investigations of serious overexposures to an industrial gamma radiography source.

    abstract::This paper describes the sequence of events, medical aspects and dose estimations for two radiographers and their driver who were seriously exposed to an iridium-192 industrial radiography source that became detached from its wind-out cable. The men came to medical attention about 1 month later by which time all three...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006090

    authors: Sevan'kaev AV,Lloyd DC,Edwards AA,Moquet JE,Nugis VY,Mikhailova GM,Potetnya OI,Khvostunov IK,Guskova AK,Baranov AE,Nadejina NM

    更新日期:2002-01-01 00:00:00

  • Dose imaging with gel-dosemeter layers: optical analysis and dedicated software.

    abstract::In radiotherapy involving thermal and epithermal neutrons, the knowledge of dose distributions, with separation of the contribution of each secondary radiation component, is of utmost importance. Layers of Fricke-Xylenol-Orange-infused gel dosemeters give the possibility of achieving such requirements because, owing t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci625

    authors: Gambarini G,Carrara M,Gay S,Tomatis S

    更新日期:2006-01-01 00:00:00

  • Assessment of radiographic screen-film systems: a comparison between the use of a microdensitometer and a drum film digitiser.

    abstract::A high-end drum film digitiser (Tango, Germany) and a calibrated linear microdensitometer developed by PTB were used to assess the modulation transfer function (MTF) and the noise power spectra (NPS) of 3 mammographic screen film systems at optical density levels of 0.8, 1.5 and 2.5. The use of a drum scanner to asses...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch563

    authors: Verdun FR,Pachoud M,Bergmann D,Buhr E

    更新日期:2005-01-01 00:00:00

  • Environmental contamination and external radiation dose rates from radionuclides released from the Fukushima Nuclear Power Plant.

    abstract::To evaluate the environmental contamination and contributory external exposure after the accident at the Fukushima Nuclear Power Plant (FNPP), the concentrations of artificial radionuclides in soil samples from each area were analysed by gamma spectrometry. Six artificial radionuclides ((131)I, (134)Cs, (137)Cs, (129m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs040

    authors: Taira Y,Hayashida N,Yamashita S,Kudo T,Matsuda N,Takahashi J,Gutevitc A,Kazlovsky A,Takamura N

    更新日期:2012-09-01 00:00:00