Time-integrated monitoring of thoron progeny concentration around closed uranium mine sites in Japan.

Abstract:

:Thoron progeny concentrations were determined using the time-integrated method around closed uranium mine sites in Japan. Because the time-integrated radon progeny monitor developed by the authors has the function to detect (212)Po, time-integrated monitoring of thoron progeny concentration is also available with the monitor. Assuming that contribution of (216)Po is negligible, equilibrium equivalent concentration of thoron (EECTn) is theoretically calculated from the etch-pit counts by (212)Po. The annual averages of EECTn observed in the investigation area were about 0.2 Bq m(-3), and they had no remarkable differences from one another.

journal_name

Radiat Prot Dosimetry

authors

Ishimori Y

doi

10.1093/rpd/ncq242

subject

Has Abstract

pub_date

2010-10-01 00:00:00

pages

452-6

issue

4

eissn

0144-8420

issn

1742-3406

pii

ncq242

journal_volume

141

pub_type

杂志文章
  • Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter.

    abstract::In the present paper, we report the indigenous development of a neutron-sensitive thermoluminescent dosemeter (TLD) based on CaSO4:Dy Teflon TL disc. The study includes indigenous development of a neutron dosemeter and its response in terms of operational quantity to different energies of neutrons under various irradi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp019

    authors: Bakshi AK,Pradhan AS,Kher RK,Srivastava K,Varadharajan G,Chatterjee S,Sathian V

    更新日期:2009-01-01 00:00:00

  • Review of the correlation between results of cytogenetic dosimetry from blood lymphocytes and EPR dosimetry from tooth enamel for victims of radiation accidents.

    abstract::The goal of this study was to compare dose estimates from electron paramagnetic resonance (EPR) dosimetry with teeth and cytogenetic dosimetry with blood lymphocytes for 30 victims of radiation accidents. The whole-body exposures estimated by tooth enamel EPR dosimetry were ranging from 0.01 to 9.3 Gy. Study group com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu203

    authors: Khvostunov IK,Ivannikov AI,Skvortsov VG,Nugis VY,Golub EV

    更新日期:2015-03-01 00:00:00

  • Managing Internal Radiation Contamination Following an Emergency: Identification of Gaps and Priorities.

    abstract::Following a radiological or nuclear emergency, first responders and the public may become internally contaminated with radioactive materials, as demonstrated during the Goiânia, Chernobyl and Fukushima accidents. Timely monitoring of the affected populations for potential internal contamination, assessment of radiatio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw199

    authors: Li C,Ansari A,Etherington G,Jourdain JR,Kukhta B,Kurihara O,Lopez MA,Ménétrier F,Alves Dos Reis A,Solomon S,Zhang J,Carr Z

    更新日期:2016-09-01 00:00:00

  • BAYESIAN SPECTRUM DECONVOLUTION INCLUDING UNCERTAINTIES AND MODEL SELECTION: APPLICATION TO X-RAY EMISSION DATA USING WINBUGS.

    abstract::Spectrum deconvolution is an important task in ionizing radiation measurements, as the pulse height spectra, or, in general, the measured data from spectrometers or other measuring instruments are usually determined by the convolution of the response function with the fluence spectra. The method presented here for obt...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy286

    authors: Behrens R,Reginatto M

    更新日期:2019-12-23 00:00:00

  • Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter.

    abstract::Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 microm thick CVD diamon...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci667

    authors: Preciado-Flores S,Schreck M,Meléndrez R,Chernov V,Bernal R,Cruz-Vázquez C,Cruz-Zaragoza E,Barboza-Flores M

    更新日期:2006-01-01 00:00:00

  • MITOCHONDRIAL MEMBRANE POTENTIAL, MORPHOLOGY AND ATP PRODUCTION IN MAMMALIAN CELLS EXPOSED TO X-RAYS.

    abstract::This study aimed to reveal the effect of X-irradiation on mitochondrial function in terms of mitochondrial membrane potential (ΔΨm) and ATP productivity. At the cellular level, ΔΨm was quantified using JC-1, a mitochondrial probe that emits red or green fluorescence at high or low ΔΨm sites, respectively. The fluoresc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy254

    authors: Hamada R,Kaminaga K,Suzuki K,Yokoya A

    更新日期:2019-05-01 00:00:00

  • A minimally invasive method to evaluate 131I kinetics in blood.

    abstract::The dose limiting factor for 131I therapy in patients with thyroid cancer is myelotoxicity, thus an accurate determination of radioiodine activity in the red marrow is of paramount importance. The reference method for red marrow dosimetry in radiometabolic therapy is based on the measurement of radioiodine kinetics, p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch041

    authors: Traino AC,Di Martino F,Boni G,Mariani G,Lazzeri M

    更新日期:2004-01-01 00:00:00

  • Environmental gamma dosimetry with OSL of alpha-Al(2)O(3):C for in situ sediment measurements.

    abstract::The physical properties of alpha-Al(2)O(3):C are very similar to that of quartz, which make it an attractive dosimetric material for geological and archaeological dating applications. Storage experiments in an ultra-low-radiation underground environment (UDO at PTB) and gamma-ray spectrometry show that the optically s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq146

    authors: Richter D,Dombrowski H,Neumaier S,Guibert P,Zink AC

    更新日期:2010-09-01 00:00:00

  • High survival of frozen cells irradiated with gamma radiation.

    abstract::Cell storage in liquid nitrogen (LN) offers the most secure method of cell preservation even if cryopreserved cells are exposed to natural background of ionising radiation (IR). A lot of experiments have demonstrated that IR can induce damages in living cells, but only a little information regarding the response of cr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq541

    authors: Cugia G,Centis F,Del Zotto G,Lucarini A,Argazzi E,Zini G,Valentini M,Bono M,Picardi F,Stramigioli S,Cesarini W,Zamai L

    更新日期:2011-02-01 00:00:00

  • Radiation protection issues for laser-based accelerators.

    abstract::Radiation particles, besides their application to fundamental research, are widely applied in all fields of science (medicine, material science, chemistry, etc.). Up to today the radiations were produced by radiation sources such as accelerators, X-ray tubes, radioactive sources with the well-known problems of costs, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr239

    authors: Esposito A

    更新日期:2011-07-01 00:00:00

  • Worldwide bioassay data resources for plutonium/americium internal dosimetry studies.

    abstract::Biokinetic models are the scientific underpinning of internal dosimetry and depend, ultimately, for their scientific validation on comparisons with human bioassay data. Three significant plutonium/americium bioassay databases, known to the authors, are described: (1) Sellafield, (2) Los Alamos and (3) the United State...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm164

    authors: Miller G,Riddell AE,Filipy R,Bertelli L,Little T,Guilmette R

    更新日期:2007-01-01 00:00:00

  • Czech results at criticality dosimetry intercomparison 2002.

    abstract::Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters use...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/nch276

    authors: Frantisek S,Jaroslav T

    更新日期:2004-01-01 00:00:00

  • Blood tritium level as an estimate of soft tissue dose.

    abstract::To test the blood tritium level as an estimate of free water tritium (FWT) and organically bound tritium (OBT) in human soft tissues, a tritiated amino acid mixture (TAA) and tritiated water (HTO) were injected or orally administered to mice. Relatively high tritium retention in the blood was found after TAA injection...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006272

    authors: Saito M

    更新日期:2003-01-01 00:00:00

  • A comparison of the response of PADC neutron dosemeters in high-energy neutron fields.

    abstract::Within the framework of the EURADOS Working Group 11, a comparison of passive neutron dosemeters in high-energy neutron fields was organised in 2011. The aim of the exercise was to evaluate the response of poly-allyl-glycol-carbonate neutron dosemeters from various European dosimetry laboratories to high-energy neutro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct275

    authors: Trompier F,Boschung M,Buffler A,Domingo C,Cale E,Chevallier MA,Esposito A,Ferrarini M,Geduld DR,Hager L,Hohmann E,Mayer S,Musso A,Romero-Esposito M,Röttger S,Smit FD,Sashala Naik A,Tanner R,Wissmann F,Caresana M

    更新日期:2014-10-01 00:00:00

  • A review of the properties of the dosimetric systems and the quality assurance programmes of 48 dosimetric services in the European Union and Switzerland.

    abstract::This paper summarises the evaluation of the 1997 EURADOS questionnaire on dosimetric systems able to assess personal dose equivalent. In total, 56 approved dosimetric services in the European Union and Switzerland responded, together monitoring approximately 615,000 occupationally exposed persons. Of these services, 4...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006572

    authors: van Dijk JW,Bordy JM,Vanhavere F,Wernli C,Zamani-Valasiadou M

    更新日期:2001-01-01 00:00:00

  • Optically stimulated luminescent glass optical fibre dosemeter.

    abstract::An optical fibre radiation dosemeter has been developed that utilises optically stimulated luminescence and scintillation to provide independent, remote, real-time dose measurements. The radiation sensitive element consists of a 1 mm long, 0.4 mm diameter piece of copper-ion-doped fused quartz that is attached to a 1 ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005974

    authors: Huston AL,Justus BL,Falkenstein PL,Miller RW,Ning H,Altemus R

    更新日期:2002-01-01 00:00:00

  • Assessment of effective dose in paediatric CT examinations.

    abstract::Current concerns focus on the high doses encountered in computed tomography (CT) examinations as they are extending towards younger and more radiosensitive patients. Previous work produced conversion coefficients for effective dose (E) from dose-length product (DLP) for four anatomical body regions applicable to any p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr288

    authors: Dougeni E,Chapple CL,Willis J,Panayiotakis G

    更新日期:2011-09-01 00:00:00

  • Calibration of EPR signal dose response of tooth enamel to photons: experiment and Monte Carlo simulation.

    abstract::The experimental energy dependence of the electron paramagnetic resonance (EPR) radiation-induced signal at irradiation by photons in the energy range of 13 keV-1.25 MeV was analysed in terms of the absorbed dose in human tooth enamel. The latter was calculated using a Monte Carlo simulation of the photon and electron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch040

    authors: Ivannikov AI,Tikunov DD,Borysheva NB,Trompier F,Skvortsov VG,Stepanenko VF,Hoshi M

    更新日期:2004-01-01 00:00:00

  • Results of field trials using the NPL simulated reactor neutron field facility.

    abstract::The NPL simulated reactor neutron field facility provides neutron spectra similar to those found in the environs of UK gas-cooled reactors. Neutrons are generated by irradiating a thick lithium-alloy target with monoenergetic protons between 2.5 and 3.5 MeV (depending on the desired spectrum), and then moderated by a ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm018

    authors: Taylor GC,Thomas DJ,Bennett A

    更新日期:2007-01-01 00:00:00

  • Radon in waterworks: dose assessment, analysis of influence parameters and improved methods of measurement.

    abstract::In Austria a comprehensive study on radiation exposure in waterworks was conducted. The aim of this study was to evaluate the risks for the affected employees. On the basis of geographical, geological and hydrological aspects, 21 waterworks were selected. A total of 85 passive short-term measurements and measurements ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu067

    authors: Michael S,Andreas B,Claudia S,Fabian R,Ringer W,Josef MF

    更新日期:2014-07-01 00:00:00

  • A fast and simple approach for the estimation of a radiological source from localised measurements after the explosion of a radiological dispersal device.

    abstract::After an explosion of a radiological dispersal device, decision-makers need to implement countermeasures as soon as possible to minimise the radiation-induced risks to the population. In this work, the authors present a tool, which can help providing information about the approximate size of source term and radioactiv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct263

    authors: Urso L,Kaiser JC,Woda C,Helebrant J,Hulka J,Kuca P,Prouza Z

    更新日期:2014-03-01 00:00:00

  • Screen-film versus digital radiography of sacroiliac joints: evaluation of image quality and dose to patients.

    abstract::The purpose of this paper is to evaluate the image quality and dose to patients in the radiography of sacroiliac joints and to perform a clinical comparative study of digital and conventional screen-film radiography. Routine radiography of sacroiliac joint was performed in 60 patients using digital and screen-film rad...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs315

    authors: Jablanovic D,Ciraj-Bjelac O,Damjanov N,Seric S,Radak-Perovic M,Arandjic D,Maksimovic R

    更新日期:2013-06-01 00:00:00

  • Luminescence dosimetry using building materials and personal objects.

    abstract::There is a growing public awareness of the risk of accidental radiation exposure due to ageing nuclear power installations, illegal dumping of nuclear waste and terrorist activities, and of the consequential health risks to populations in addition to social and economic disturbance extending beyond national boundaries...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci699

    authors: Göksu HY,Bailiff IK

    更新日期:2006-01-01 00:00:00

  • Parallel FD-TD simulation of radiobase antennae.

    abstract::The rigorous characterisation of the behaviour of a radiobase antenna for wireless communication systems is a hot topic both for antenna or communication system design and for radioprotection-hazard reasons. Such a characterisation deserves a numerical solution, and the use of a finite-difference time-domain (FD-TD) a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006699

    authors: Catarinucci L,Palazzari P,Tarricone L

    更新日期:2001-01-01 00:00:00

  • Study of the dosimetric characteristics of cosmic radiation at civil aviation altitudes.

    abstract::The dependence of the doses on solar activity for intermediate levels of the solar modulation parameter has been studied by means of simulations carried out by the Monte Carlo transport code FLUKA. The vertical cut-off rigidities investigated lie between 0.4 and 6.1 GV. The calculated results show that the linear depe...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006099

    authors: Ferrari A,Pellicioni M,Rancati T

    更新日期:2002-01-01 00:00:00

  • Energy dependence of W values of protons in water.

    abstract::The W values of protons in water vapour were measured for energies from 1 keV to 100 keV with uncertainties lower than 1%. To study the energy and phase dependence of W values, the W values of protons in water vapour and liquid water were calculated for energies from 0.1 keV and 10 MeV and then compared to the experim...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006798

    authors: Willems G,Back WY,Grosswendt B

    更新日期:2002-01-01 00:00:00

  • ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.

    abstract::The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protect...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci702

    authors: Vano E,Faulkner K

    更新日期:2005-01-01 00:00:00

  • New Correction Factors Based on Seasonal Variability of Outdoor Temperature for Estimating Annual Radon Concentrations in UK.

    abstract::Indoor radon concentrations generally vary with season. Radon gas enters buildings from beneath due to a small air pressure difference between the inside of a house and outdoors. This underpressure which draws soil gas including radon into the house depends on the difference between the indoor and outdoor temperatures...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw270

    authors: Daraktchieva Z

    更新日期:2017-06-01 00:00:00

  • Radioactive waste management and decommissioning of accelerator facilities.

    abstract::During the operation of high-energy accelerators, the interaction of radiation with matter can lead to the activation of the machine components and of the surrounding infrastructures. As a result of maintenance operation and during decommissioning of the installation, considerable amounts of radioactive waste are evac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp196

    authors: Ulrici L,Magistris M

    更新日期:2009-11-01 00:00:00

  • Radon concentration measurements in bituminous coal mines.

    abstract::Radon measurements were carried out in Kozlu, Karadon and Uzülmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch449

    authors: Fisne A,Okten G,Celebi N

    更新日期:2005-01-01 00:00:00