CALCULATION OF SKIN DOSE DUE TO BETA CONTAMINATION USING THE NEW QUANTITY OF THE ICRP 116: THE 'LOCAL SKIN DOSE'.

Abstract:

:Values of the new protection quantity 'Local Skin Dose' LSD, introduced by the International Commission on Radiological Protection (ICRP) Publication 116, were calculated for 134 β- or β+ emitting radionuclides, using the Monte Carlo code MCNP6. Two types of source geometry are considered: a point source and disc-type surface contamination (the source is placed in contact with the skin). This new protection quantity is compared with the operational quantity H'(0.07,0°), leading us to conclude that, in accordance with the rules of the ICRP, the operational quantity over-estimates the protection quantity to a reasonable extent, except in very rare cases for very low average beta energies. Thus, with the new skin model described in ICRP 116, there are no longer any major differences between the operational quantities and protection quantities estimated with the skin model described in ICRP 74.

journal_name

Radiat Prot Dosimetry

authors

Bourgois L,Ménard S,Comte N

doi

10.1093/rpd/ncx019

subject

Has Abstract

pub_date

2017-11-01 00:00:00

pages

365-379

issue

4

eissn

0144-8420

issn

1742-3406

pii

3058924

journal_volume

176

pub_type

杂志文章
  • A legally approved personal dosemeter for photon and beta radiation based on direct ion storage.

    abstract::The novel DIS-1 dosemeter developed by RADOS is based on ionisation chambers with so-called Direct Ion Storage (DIS). The dosemeter can measure Hp(10) and Hp(0.07) of photon and Hp(0.07) of beta irradiation. The characteristics of the commercially available DIS-1 dosemeter were studied at the Paul Scherrer Institute, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005984

    authors: Boschung M,Fiechtner A,Wernli C

    更新日期:2002-01-01 00:00:00

  • GAMMA DOSE RATES IN THE HIGH BACKGROUND RADIATION AREA OF MANGALORE REGION, INDIA.

    abstract::Elevated levels of natural background radiation due to scattered patches of monazite sand around the beaches of Mangalore, India, have been reported earlier. A comparative study of gamma dose rates was performed in both normal background and high natural background radiation areas around Mangalore using different type...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz063

    authors: Al-Azmi D,Kumara S,Mohan MP,Karunakara N

    更新日期:2019-10-01 00:00:00

  • Evaluating the performance of the Harshaw™ DXTRAD LiF:Mg,Cu,P finger ring with two different thickness filters.

    abstract::Amongst the dosemeters offered by the Health Protection Agency (HPA) Personal Dosimetry Service are finger rings, which use the Harshaw™ DXTRAD element. This paper describes restricted-type testing carried out by HPA on the previously untried combination of the LiF:Mg,Cu,P material and a thicker filter (42 mg cm(-2))....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq564

    authors: Baker ST,Roberts GH,Gilvin PJ

    更新日期:2011-03-01 00:00:00

  • Independent evaluation of optically stimulated luminescence (OSL) 'dot' dosemeters for environmental monitoring.

    abstract::Optically stimulated luminescence (OSL) 'dot' dosemeters (manufactured by Landauer®) are reported to have a high degree of environmental stability, high level of sensitivity and provide wide range of dose measuring capabilities from 0.05 mGy to 100 Gy. The optical read out method is fast and relatively simple and perm...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq289

    authors: Timilsina B,Gesell TF

    更新日期:2011-01-01 00:00:00

  • VALIDATION OF A BEAMNRC MONTE CARLO SIMULATION OF A BROAD BEAM DIAGNOSTIC X-RAY UNIT.

    abstract::A BEAMnrc Monte Carlo simulation of a diagnostic X-ray unit in a broad beam geometry intended for the derivation of effective linear attenuation coefficients was validated against measurements made on the X-ray unit on which the simulation was based. The validation process assessed the size of the beam, the first and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz032

    authors: Worrall M,Sutton DG

    更新日期:2019-12-31 00:00:00

  • Dosimetric data and radiation risk analysis for new procedures in interventional cardiology.

    abstract::The purpose of this study was to evaluate radiation doses to the patients and operators during interventional cardiology procedures, with a particular focus on the transcatheter aortic valve implantation (TAVI). Patient doses for 5549 diagnostic and therapeutic procedures and 76 TAVI were examined, as well as occupati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq208

    authors: Signorotto P,del Vecchio A,Montorfano M,Maisano F,Giagnorio M,Bellanca R,Colombo A,Calandrino R

    更新日期:2010-12-01 00:00:00

  • A recoil-proton spectrometer based on a p-i-n diode implementing pulse-shape discrimination.

    abstract::A recoil-proton spectrometer was created by coupling a p-i-n diode with a polyethylene converter. The maximum detectable energy, imposed by the thickness of the totally depleted layer, is approximately 6 MeV. The minimum detectable energy is limited by the contribution of secondary electrons generated by photons in th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch237

    authors: Agosteo S,D'Angelo G,Fazzi A,Foglio Para A,Pola A,Ventura L,Zotto P

    更新日期:2004-01-01 00:00:00

  • Occurrence of natural radioactivity in public water supplies in Germany: (238)U, (234)U, (235)U, (228)RA, (226)RA, (222)RN, (210)PB, (210)PO and gross alpha activity concentrations.

    abstract::The Federal Office for Radiation Protection performed a representative survey on the radiological quality of drinking water in Germany. The aim of this study was to determine regional variations of natural radionuclide concentrations and to estimate radiation exposures caused by drinking water consumption. The study i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq139

    authors: Beyermann M,Bünger T,Schmidt K,Obrikat D

    更新日期:2010-09-01 00:00:00

  • Radon progeny in hydrometeors at the earth's surface.

    abstract::During atmospheric thermal inversions, dew and hoarfrost concentrate gamma emitting radionuclides of the short-lived (222)Rn progeny ((214)Pb and (214)Bi), causing an increase in the total natural gamma background from the ground. To highlight this phenomenon, a volcanic zone of high (222)Rn flux was studied during th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr402

    authors: Voltaggio M

    更新日期:2012-07-01 00:00:00

  • Contribution of different foodstuffs to the internal exposure of rural inhabitants in Russia after the Chernobyl accident.

    abstract::In a large village, Veprin of the Bryansk region of Russia contaminated with radionuclides as a result of the Chernobyl accident, 137Cs concentration in food products of agricultural produce and natural origin was regularly measured, local inhabitants were polled on the composition of their diet, and the 137Cs content...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006445

    authors: Travnikova IG,Bruk GJ,Shutov VN,Bazjukin AB,Balonov MI,Rahola T,Tillander M

    更新日期:2001-01-01 00:00:00

  • On a model-based approach to radiation protection.

    abstract::There is a preoccupation with linearity and absorbed dose as the basic quantifiers of radiation hazard. An alternative is the fluence approach, whereby radiation hazard may be evaluated, at least in principle, via an appropriate action cross section. In order to compare these approaches, it may be useful to discuss th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006828

    authors: Waligórski MP

    更新日期:2002-01-01 00:00:00

  • Dosimetric monitoring in Ukraine--present status and path to the future.

    abstract::Despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralised dose accounting system in Ukraine; existing dosimetry services operate obsolete manual thermoluminescence dosemeter (TLD) readers and do not meet modern proficiency standards. Currently, dosimetric monitoring is ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl128

    authors: Chumak V,Boguslavskaya A

    更新日期:2007-01-01 00:00:00

  • Keeping up with the neighbours--measuring the bystander response.

    abstract::Ionising radiation can induce responses within non-exposed neighbouring (bystander) cells, which potentially have important implications on the estimates of risk at environmentally relevant doses. Using human skin fibroblasts (AG1522), a range of methods were used to investigate the nature of the signal(s) arising fro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl430

    authors: Pyke EL,Stevens DL,Hill MA

    更新日期:2006-01-01 00:00:00

  • A solid state microdosimeter based on a monolithic silicon telescope.

    abstract::A monolithic silicon telescope, consisting of a DeltaE and an E stage-detector ( approximately 1.9 microm and 500 microm thick, respectively), was coupled to a polyethylene converter in order to investigate the feasibility of a solid state microdosimeter with respect to the field-funnelling effect. This work discusses...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl468

    authors: Agosteo S,Colautti P,Fazzi A,Moro D,Pola A

    更新日期:2006-01-01 00:00:00

  • Neutron area survey instrument measurements in the EVIDOS project.

    abstract::Neutron survey instruments have been exposed at all the measurement locations used in the EVIDOS project. These results have an important impact in the interpretation of the results from the project, since operationally the survey instrument will be used for an initial assessment of and routine monitoring of the ambie...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm160

    authors: Tanner RJ,Bolognese-Milsztajn T,Boschung M,Coeck M,Curzio G,d'Errico F,Fiechtner A,Hager LG,Hussien M,Kyllönen JE,Lacoste V,Lindborg L,Luszik-Bhadra M,Molinos C,Reginatto M,Schuhmacher H,Vanhavere F

    更新日期:2007-01-01 00:00:00

  • The present ICRP protection quantitites are seriously flawed. Opposing the proposition.

    abstract::Our debaters have agreed to defend positions that appear to be diametrically opposed; nevertheless, they have acknowledged some common ground. Although it was not explicitly stated, they would no doubt agree that workers and the public are adequately protected by our present system of radiation regulations. Our debate...

    journal_title:Radiation protection dosimetry

    pub_type: 评论,杂志文章

    doi:

    authors: Edwards AA

    更新日期:2003-01-01 00:00:00

  • Electron spin resonance evaluation of pure CaSO4 and as a phosphor doped with P and Dy.

    abstract::Polycrystalline CaSO4 powder, doped with different elements but mainly rare earths, is one of the most interesting thermoluminescent (TL) materials. Although many electron spin resonance (ESR) analyses have been reported for these materials few studies have been published about the potential of CaSO4 for ESR dosimetry...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006047

    authors: de Jesus EF,Rossi AM,Lopes RT

    更新日期:2002-01-01 00:00:00

  • Development of a voxel phantom of Japanese adult male in upright posture.

    abstract::A Japanese voxel phantom in upright posture, JM2, has been developed on the basis of CT images of a healthy Japanese adult male. Body characteristics of JM2 were compared with those of the supine voxel phantom, JM, previously developed using CT images of the same person. Differences were found in the shapes of the spi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm272

    authors: Sato K,Noguchi H,Endo A,Emoto Y,Koga S,Saito K

    更新日期:2007-01-01 00:00:00

  • Radon concentrations in three underground lignite mines in Turkey.

    abstract::Monitoring of radon in underground mines is important in order to assess the radiological hazards to occupational workers. Radon concentration levels in three underground lignite mines (Tunçbilek, Omerler and Eynez) of Turkey were obtained in this study. For this reason, atmospheric radon level measurements were carri...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp179

    authors: Cile S,Altinsoy N,Celebi N

    更新日期:2010-01-01 00:00:00

  • Ratio of aerosol and gases of radioactive chlorine and particle size distribution of aerosol formed by high-energy proton irradiation.

    abstract::To estimate internal doses due to the inhalation of radionuclides produced by the nuclear spallation of the air nuclei in high-energy proton accelerator facilities, the physicochemical properties of radionuclides are very important. Thus, the ratio of aerosol and gases of 38Cl and 39Cl formed by irradiating argon gas-...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm475

    authors: Yokoyama S,Sato K,Manabe K,Noguchi H,Kaneko H,Oki Y,Iida T,Tanaka S

    更新日期:2007-01-01 00:00:00

  • Evaluation of risk of deterministic effects in fluoroscopically guided procedures.

    abstract::A methodology for the evaluation of skin dose distribution and possible skin injuries on patients undergoing interventional procedures has been developed as part of the European DIMOND programme. Relevant dosimetric data from the procedures are recorded and other specific measurements for skin dose evaluation (slow fi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci714

    authors: Vano E,Gonzalez L,Guibelalde E,Aviles P,Fernandez JM,Prieto C,Galvan C

    更新日期:2005-01-01 00:00:00

  • Type Testing of Model 7200 Automatic TLD Reader.

    abstract::The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminesce...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw100

    authors: Malek Mohammadi M,Hosseini Pooya SM

    更新日期:2017-04-20 00:00:00

  • LESSONS LEARNED FROM THE EURADOS SURVEY ON INDIVIDUAL MONITORING DATA AND INTERNAL DOSE ASSESSMENTS OF FOREIGNERS EXPOSED IN JAPAN FOLLOWING THE FUKUSHIMA DAIICHI NPP ACCIDENT.

    abstract::European Radiation Dosimetry Group e.V. (EURADOS) survey on individual monitoring data and dose assessment has been carried out for 550 foreigners returning home after being exposed in Japan to intakes of radionuclides (mainly (131)I, (132)I, (132)Te, (134)Cs and (137)Cs) as a consequence of the Fukushima Daiichi NPP ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv510

    authors: Lopez MA,Fojtik P,Franck D,Osko J,Gerstmann U,Scholl C,Lebacq AL,Breustedt B,Del Risco Norrlid L

    更新日期:2016-09-01 00:00:00

  • Determination of radon concentration levels in well water in Konya, Turkey.

    abstract::Radon ((222)Rn) measurements were undertaken in 16 samples of well water representing different depths and different types of aquifers found at the city centre of Konya, Central Turkey. The radon activity concentrations of the well water samples collected in the spring and summer seasons of 2012 were measured by using...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct099

    authors: Erdogan M,Eren N,Demirel S,Zedef V

    更新日期:2013-10-01 00:00:00

  • Accreditation of testing laboratories in dosimetry: the use of a flexible scope at the Competent Incorporation Measuring Body Jülich.

    abstract::The accreditation of the Competent Incorporation Measuring Body at Jülich includes incorporation monitoring by means of direct measurements of the body activity as well as by means of indirect determination of the body activity by radiochemical analysis of excreta samples. In both testing areas, it proved to be very u...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq360

    authors: Hill P,Froning M,Schläger M,Zoriy MV,Lennartz R

    更新日期:2011-03-01 00:00:00

  • INVESTIGATION OF EXTERNAL RADIATION DOSES DURING RESIDENTS' TEMPORAL STAY TO NAMIE TOWN, FUKUSHIMA PREFECTURE.

    abstract::Namie Town in Fukushima Prefecture, the majority of which was an evacuation area as a result of the effects of the Fukushima Daiichi Nuclear Power Plant accident, carried out a 'temporal stay' in September 2016 so that residents could check their houses. Therefore, in cooperation with the town authorities, the authors...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz107

    authors: Tsujiguchi T,Shiroma Y,Suzuki T,Tamakuma Y,Yamaguchi M,Iwaoka K,Hosoda M,Tokonami S,Kashiwakura I

    更新日期:2019-10-01 00:00:00

  • 30-y follow-up of a Pu/Am inhalation case.

    abstract::In 1983, a young man inhaled accidentally a large amount of plutonium and americium. This case was carefully followed until 2013. Since no decorporation measures had been taken, the undisturbed metabolism of Pu and Am can be derived from the data. First objective was to determine the amount of inhaled radionuclides an...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu342

    authors: Wernli C,Eikenberg J,Marzocchi O,Breustedt B,Oestreicher U,Romm H,Gregoratto D,Marsh J

    更新日期:2015-04-01 00:00:00

  • Assessing The Risk Associated with Simultaneous Exposure To Mobile Communication Signals Within 900-2500 MHz in Nigeria.

    abstract::In this study, the total exposure due to signals within GSM 900, GSM 1800, CDMA-1900 and 3G-2100 frequency bands at 200 m from the foot of 120, 100 and 80 base station masts in the Nigerian cities of Lagos, Ibadan and Abuja, respectively, was assessed. A calibrated hand-held spectrum analyser was used to measure the l...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa203

    authors: Ayinmode BO,Farai IP

    更新日期:2020-12-31 00:00:00

  • Radiation dose to premature new-borns in the Belgian neonatal intensive care units.

    abstract::In the neonatal intensive care units (NICU), premature new-borns may be exposed to important doses. Because of their increased radiosensitivity and longer life expectancy, dose optimisation is of importance. The present study aimed at evaluating the dose of the most common radiographs in the Belgian NICU. Entrance sur...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct184

    authors: Dabin J,Struelens L,Vanhavere F

    更新日期:2014-01-01 00:00:00

  • Managing Internal Radiation Contamination Following an Emergency: Identification of Gaps and Priorities.

    abstract::Following a radiological or nuclear emergency, first responders and the public may become internally contaminated with radioactive materials, as demonstrated during the Goiânia, Chernobyl and Fukushima accidents. Timely monitoring of the affected populations for potential internal contamination, assessment of radiatio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw199

    authors: Li C,Ansari A,Etherington G,Jourdain JR,Kukhta B,Kurihara O,Lopez MA,Ménétrier F,Alves Dos Reis A,Solomon S,Zhang J,Carr Z

    更新日期:2016-09-01 00:00:00