Shielding design of a brachytherapy unit at the Korle Bu teaching hospital in Ghana: comparison of theoretical calculations and experimental study.

Abstract:

:A theoretical study was carried out to re-evaluate the integrity of the biological shielding of (137)Cs brachytherapy unit at the Korle Bu Teaching Hospital, Ghana, and the results were verified by measurement of the dose rates at selected locations. The primary objective was to determine the current state of protection and safety of staff and the general public. Shielding design of the brachytherapy unit at the hospital was based on postulated workload and occupancy factors of the facility. The facility has been in existence for 12 y and has accumulated operational workload data that differs from the postulated one. The results show that despite the variation in actual and postulated workloads, the dose rates were below the reference values 0.5 microSv h(-1) for public areas and 7.5 microSv h(-1) for controlled areas. These values were in the range of 0.10-0.12 microSv h(-1) for public areas and of 0.50-2.10 microSv h(-1) for controlled areas.

journal_name

Radiat Prot Dosimetry

authors

Arwui CC,Schandorf C,Nani K,Darko EO,Deatanyah P

doi

10.1093/rpd/ncq001

subject

Has Abstract

pub_date

2010-06-01 00:00:00

pages

59-66

issue

1

eissn

0144-8420

issn

1742-3406

pii

ncq001

journal_volume

140

pub_type

杂志文章
  • Biophysical analysis of radiation induced initial DNA fragmentation.

    abstract::Production of double strand breaks (DSBs) and double-stranded DNA fragments after irradiation with high energy nitrogen ions was simulated with stochastic track generation and a high-order chromatin structure (HOCS) model representing a segment of interphase chromosome. The non-random distribution of DNA fragments is ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006748

    authors: Khvostunov IK,Andreev SG,Eidelman Y

    更新日期:2002-01-01 00:00:00

  • Experimental simulation of A-bomb gamma ray spectra for radiobiology studies.

    abstract::Improved radiation protection of humans requires a better understanding of the mechanisms of radiation action and accurate estimates of radiation risk for both internal and external radiations. The Japanese atomic bomb survivors represent one of the most important sources of human data on the late carcinogenic effects...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006532

    authors: Pattison JE,Hugtenburg RP,Charles MW,Beddoe AH

    更新日期:2001-01-01 00:00:00

  • A study of the correlation between dose area product and effective dose in vascular radiology.

    abstract::The purpose of the multi-centre study was to assess dose area product (DAP) and effective dose of patients undergoing angiography of the lower limbs in Belgium and to investigate the correlation between DAP and effective dose. DAP values were measured in 12 centres and compared with the national diagnostic reference l...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn050

    authors: Smans K,Struelens L,Hoornaert MT,Bleeser F,Buls N,Berus D,Clerinx P,Malchair F,Vanhavere F,Bosmans H

    更新日期:2008-01-01 00:00:00

  • Patient dose in digital projection radiography.

    abstract::In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and direct radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Radiology Emergency Department of our hospital, a flat-panel DR equipment (Siemens Axiom Ari...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn013

    authors: Compagnone G,Pagan L,Baleni MC,Calzolaio FL,Barozzi L,Bergamini C

    更新日期:2008-01-01 00:00:00

  • Radon in underground waters as a natural analogue to study the escape of CO2 in geological repositories.

    abstract::Activity concentrations of dissolved (222)Rn and (226)Ra were measured in several underground aquifers, which are candidates for repositories or for the study of analogue natural escapes of CO2. The concentration of both radionuclides in water was determined using liquid scintillation counting. The values obtained for...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv232

    authors: Martín Sánchez A,Ruano Sánchez AB,de la Torre Pérez J,Jurado Vargas M

    更新日期:2015-11-01 00:00:00

  • Dose estimation using quartz OSL in the non-linear region of the growth curve.

    abstract::The reliability of equivalent-dose determinations on quartz made with the single-aliquot regenerative-dose (SAR) protocol is examined using a suite of sedimentary samples for which the equivalent dose is expected to be >200 Gy. Experiments on one sample were used to evaluate the precision obtained using the standard m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006004

    authors: Murray AS,Wintle AG,Wallinga J

    更新日期:2002-01-01 00:00:00

  • Development of thermal neutron-sensitive glass dosemeter containing lithium.

    abstract::New radiophotoluminescence (RPL) phosphate glass containing (6)Li was successfully made from the powder of NaPO(3), Al(PO(3))(3), LiOH, HPO(3) and AgCl. The ternary diagram of NaPO(3)-Al(PO(3))(3)-LiPO(3) has clarified the region where satisfactory RPL characteristics of the glass are kept up. The synthesised phosphat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq552

    authors: Maki D,Kobayashi H,Sato F,Murata I,Kato Y,Tanaka T,Yamamoto T,Iida T

    更新日期:2011-03-01 00:00:00

  • Contribution of different foodstuffs to the internal exposure of rural inhabitants in Russia after the Chernobyl accident.

    abstract::In a large village, Veprin of the Bryansk region of Russia contaminated with radionuclides as a result of the Chernobyl accident, 137Cs concentration in food products of agricultural produce and natural origin was regularly measured, local inhabitants were polled on the composition of their diet, and the 137Cs content...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006445

    authors: Travnikova IG,Bruk GJ,Shutov VN,Bazjukin AB,Balonov MI,Rahola T,Tillander M

    更新日期:2001-01-01 00:00:00

  • A minimally invasive method to evaluate 131I kinetics in blood.

    abstract::The dose limiting factor for 131I therapy in patients with thyroid cancer is myelotoxicity, thus an accurate determination of radioiodine activity in the red marrow is of paramount importance. The reference method for red marrow dosimetry in radiometabolic therapy is based on the measurement of radioiodine kinetics, p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch041

    authors: Traino AC,Di Martino F,Boni G,Mariani G,Lazzeri M

    更新日期:2004-01-01 00:00:00

  • Quality control of micro-computed tomography systems.

    abstract::The rapid proliferation of micro-computed tomography (micro-CT) scanners in preclinical small animal studies has created a need for a method on scanner performance evaluation and scan parameter optimisation. The purpose of this study was to investigate the performance of the scanner with a dedicated micro-CT phantom. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq088

    authors: Eloot L,Buls N,Covens P,Willekens I,Lahoutte T,de Mey J

    更新日期:2010-04-01 00:00:00

  • Different versions of the right answer: the importance of measurement uncertainty in radiation dosimetry.

    abstract::The performance of radiation dosemeters that are issued by approved individual monitoring services generally meet international standards, with typical results within a few tens of per cent of the reference value. Experienced dosimetry practitioners will understand the uncertainties and treat monitoring results with d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq298

    authors: Gilvin P,McWhan A

    更新日期:2011-03-01 00:00:00

  • Radioactive pollution from Fukushima Daiichi nuclear power plant in the terrestrial environment.

    abstract::Major contaminants from venting and hydrogen explosions at the Fukushima Daiichi nuclear reactors between 12 and 15 March 2011 were transported northwestward and deposited on soil and plants via precipitation. Surface soils and plant leaves were sampled at 64 sites in the Fukushima Prefecture. The highest concentratio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs222

    authors: Tazoe H,Hosoda M,Sorimachi A,Nakata A,Yoshida MA,Tokonami S,Yamada M

    更新日期:2012-11-01 00:00:00

  • Recent results of irradiations of DIS-1 dosemeters with an XR200 X-ray flash unit.

    abstract::Earlier measurements have revealed that active electronic dosemeters have deficiencies in pulsed fields of ionising radiation due to the counting technique used. The DIS-1 dosemeter uses a promising technology, which should be basically suitable for measurements in pulsed fields. In this paper, first measurements with...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs265

    authors: Zutz H,Hupe O

    更新日期:2013-05-01 00:00:00

  • Organ dose conversions from ESR measurements using tooth enamel of atomic bomb survivors.

    abstract::Dose conversions were studied for dosimetry of atomic bomb survivors based upon electron spin resonance (ESR) measurements of tooth enamel. Previously analysed data had clarified that the tooth enamel dose could be much larger than other organ doses from a low-energy photon exposure. The radiation doses to other organ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr408

    authors: Takahashi F,Sato K

    更新日期:2012-03-01 00:00:00

  • Harmonization of individual dosimetry quality control within metrology system of a small country.

    abstract::A programme of harmonization of individual dosimetry quality control organized in the framework of a distributed metrology system is presented as seen from the experiences gained in Slovenia. As a part of the programme intercomparison of dosimetry services was organized and basic characteristics of dosimetry systems c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm198

    authors: Stuhec M,Zorko B,Vekić B,Miljanić S,Ban R,Basić B

    更新日期:2007-01-01 00:00:00

  • THE CHALLENGE IN USING THE RETROSPECTIVE ASSESSMENT OF RESIDENTIAL RADON CONCENTRATION.

    abstract::In the present study, the contemporary indoor radon activity concentration and the surface-deposited 210Po activity were measured in 65 Romanian dwellings. The activity of trapped 210Po on the glass surface was measured using the (CR-LR) difference technique. The retrospective radon activity concentration estimated on...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy095

    authors: Dicu T,Burghele BD,Lupulescu D,Cucos A

    更新日期:2018-09-01 00:00:00

  • Occupational radiation protection of health workers in imaging.

    abstract::Occupational radiological protection (RP) is still a challenge in several clinical practices. ICRP has included specific recommendations and advice for occupational protection in most of the documents published in recent years and its current programme of work includes the preparation of documents with specific conten...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu354

    authors: Vano E

    更新日期:2015-04-01 00:00:00

  • Dosimetry of clinical neutron and proton beams: an overview of recommendations.

    abstract::Neutron therapy beams are obtained by accelerating protons or deuterons on Beryllium. These neutron therapy beams present comparable dosimetric characteristics as those for photon beams obtained with linear accelerators; for instance, the penetration of a p(65)+Be neutron beam is comparable with the penetration of an ...

    journal_title:Radiation protection dosimetry

    pub_type: 指南,杂志文章,实务指引,评审

    doi:10.1093/rpd/nch221

    authors: Vynckier S,International Atomic Energy Agency.,International Commission on Radiation Units and Measurements.

    更新日期:2004-01-01 00:00:00

  • IMPROVEMENT OF GAMMA-RAY SUBTRACTION PROCEDURE FOR A CURRENT-MODE NEUTRON DETECTOR WITH A PAIR OF 6Li- AND 7Li-GLASS SCINTILLATORS.

    abstract::A current-mode neutron detector with a pair of 6Li- and 7Li-glass scintillators has been developed to measure high-flux neutrons in a boron neutron capture therapy field. Neutrons are basically measured by subtracting gamma-ray component using current outputs from the 7Li-glass scintillator. In the present study, the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz266

    authors: Matsumoto T,Masuda A,Harano H,Hori JI,Sano T

    更新日期:2020-06-12 00:00:00

  • Fetal radiation dose in computed tomography.

    abstract::The connection between recorded volumetric CT dose index (CTDI vol) and determined mean fetal dose (Df) was examined from metal-oxide-semiconductor field-effect transistor dose measurements on an anthropomorphic female phantom in four stages of pregnancy in a 64-slice CT scanner. Automated tube current modulation kept...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv097

    authors: Kelaranta A,Kaasalainen T,Seuri R,Toroi P,Kortesniemi M

    更新日期:2015-07-01 00:00:00

  • Achievements in workplace neutron dosimetry in the last decade: lessons learned from the EVIDOS project.

    abstract::The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm095

    authors: Tanner RJ,Bolognese-Milsztajn T,Boschung M,Coeck M,Curzio G,d'Errico F,Fiechtner A,Lillhök JE,Lacoste V,Lindborg L,Luszik-Bhadra M,Reginatto M,Schuhmacher H,Vanhavere F

    更新日期:2007-01-01 00:00:00

  • Comparison of results from quality control of physical parameters and results from clinical evaluation of mammographic images for the mammography screening facilities in Poland.

    abstract::The material for this study comprised control protocols from 248 mammography screening facilities, prepared by physicists employed at 16 Regional Coordinating Centres and the results from the clinical evaluation of mammographic images in 248 facilities in Poland. All mammograms were evaluated independently by three ex...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncr321

    authors: Fabiszewska E,Grabska I,Jankowska K,Wesolowska E,Bulski W

    更新日期:2011-09-01 00:00:00

  • Characterisation of neutron fields: challenges in assessing the directional distribution.

    abstract::The SCK·CEN has carried out neutron field characterisation campaigns at several nuclear reactors. The main goal of these measurement campaigns was to evaluate the performance of different neutron personal dosemeters. To be able to evaluate the performance of neutron personal dosemeters in terms of Hp(10), knowledge of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu193

    authors: Cauwels V,Vanhavere F,Reginatto M

    更新日期:2014-10-01 00:00:00

  • ANALYSIS BY SCANNER OF TRACKS PRODUCED BY RADON ALPHA PARTICLES IN CR-39 DETECTORS.

    abstract::The most used passive detectors for Radon measurement are the CR39s, both for the good stability of the material and for the practicality of use. But, commercial reading systems are expensive and not always fast. The aim of the present work was the development of a method for a rapid, efficient and economic evaluation...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa140

    authors: Sabbarese C,Ambrosino F,Roca V

    更新日期:2020-11-27 00:00:00

  • Studies on the current 137Cs body burden of children in Belarus--can the dose be further reduced?

    abstract::After the Chernobyl reactor accident wide areas of Belarus were contaminated with radioactive fallout. The verification and documentation of the long-term development of radiation doses is still going on. A population group of special concern are the children living in contaminated regions. The annual dose limit of 1 ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm153

    authors: Hill P,Schläger M,Vogel V,Hille R,Nesterenko AV,Nesterenko VB

    更新日期:2007-01-01 00:00:00

  • Measurement of neutron dose with an organic liquid scintillator coupled with a spectrum weight function.

    abstract::A dose evaluation method for neutrons in the energy range of a few MeV to 100 MeV has been developed using a spectrum weight function (G-function), which is applied to an organic liquid scintillator of 12.7 cm in diameter and 12.7 cm in length. The G-function that converts the pulse height spectrum of the scintillator...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006071

    authors: Kim E,Endo A,Yamaguchi Y,Yoshizawa M,Nakamura T

    更新日期:2002-01-01 00:00:00

  • Childhood leukaemia near British nuclear installations: methodological issues and recent results.

    abstract::In 2008, the German Childhood Cancer Registry published the results of the Kinderkrebs in der Umgebung von Kernkraftwerken (KiKK) study of childhood cancer and leukaemia around German nuclear power stations. The positive findings appeared to conflict with the results of a recent British analysis carried out by the Com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncn254

    authors: Bithell JF,Keegan TJ,Kroll ME,Murphy MF,Vincent TJ

    更新日期:2008-01-01 00:00:00

  • Radiation-induced DNA damage responses.

    abstract::The amazing feature of ionising radiation (IR) as a DNA damaging agent is the range of lesions it induces. Such lesions include base damage, single strand breaks (SSBs), double strand breaks (DSBs) of varying complexity and DNA cross links. A range of DNA damage response mechanisms operate to help maintain genomic sta...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncl495

    authors: Jeggo P,Löbrich M

    更新日期:2006-01-01 00:00:00

  • Terrestrial gamma radioactivity levels and their corresponding extent exposure of environmental samples from Wadi El Assuity protective area, Assuit, Upper Egypt.

    abstract::Representative environmental samples (sandy soil, limestone, marble and gravels) collected from Wadi El Assuity, protective area, Assuit governorate in Upper Egypt have been investigated radiometrically using NaI (Tl) gamma-ray spectrometer. The specific activity of the radionuclides in Bq kg⁻¹ for soil ranged between...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq425

    authors: El-Taher A

    更新日期:2011-06-01 00:00:00

  • Dutch distribution zones of stable iodine tablets based on atmospheric dispersion modelling of accidental releases from nuclear power plants.

    abstract::Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq114

    authors: Kok-Palma Y,Leenders M,Meulenbelt J

    更新日期:2010-08-01 00:00:00