Abstract:
:A method to estimate plutonium content from a limited number of samples of lungs and pulmonary lymph nodes obtained at autopsies of former Mayak Production Association (MPA) workers is described. Historically from one to five samples of lung lobes and one to three respiratory lymph nodes (bronchopulmonary, tracheobronchial and paratracheal) were collected. The samples were used to estimate organ plutonium contents for cases where incomplete sets of samples were obtained, i.e. one to four lung lobes and one to two lymph nodes. This method was developed and validated using individual measurement data from 259 MPA autopsy cases with complete lung samples (five lobes) and three lymph nodes. A good correlation of plutonium content in measurements of two and four lung samples with the content estimate by five lung samples was obtained. The correlations with the individual lymph nodes were less robust than with the lung. The data are used to develop biokinetic, dosimetry and risk models for humans exposed to plutonium.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Sokolova AB,Suslova KG,Miller SCdoi
10.1093/rpd/ncw218subject
Has Abstractpub_date
2017-11-01 00:00:00pages
132-143issue
1-2eissn
0144-8420issn
1742-3406pii
ncw218journal_volume
176pub_type
杂志文章abstract::Risks of childhood leukaemia and lymphoma were investigated for specific work-related exposures of mothers in the UK Childhood Cancer Study. Interviews with parents of 1881 leukaemia and lymphoma cases (0-14 years) and 3742 controls collected job histories recording exposure to eight specific agents. Exposure was (1) ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn265
更新日期:2008-01-01 00:00:00
abstract::Classical methods of assessing the uncertainty associated with radiation doses estimated using cytogenetic techniques are now extremely well defined. However, several authors have suggested that a Bayesian approach to uncertainty estimation may be more suitable for cytogenetic data, which are inherently stochastic in ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/nct301
更新日期:2014-12-01 00:00:00
abstract::To estimate internal doses due to the inhalation of radionuclides produced by the nuclear spallation of the air nuclei in high-energy proton accelerator facilities, the physicochemical properties of radionuclides are very important. Thus, the ratio of aerosol and gases of 38Cl and 39Cl formed by irradiating argon gas-...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm475
更新日期:2007-01-01 00:00:00
abstract::During the 7th European Conference on Protection Against Radon at Home and at Work held in the autumn of 2013 in Prague, the second intercomparison of measuring instruments for radon and its short-lived decay products and the first intercomparison of radon/thoron gas discriminative passive detectors in mix field of ra...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu079
更新日期:2014-07-01 00:00:00
abstract::This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reade...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz186
更新日期:2019-12-31 00:00:00
abstract::It is popularly known that people who entered into the ground-zero area shortly after the atomic bombings in Hiroshima and Nagasaki suffered from various syndromes similar to acute radiation effects. External exposures from neutron-induced radionuclides in soil have recently been reassessed based on DS02 calculations ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr370
更新日期:2012-03-01 00:00:00
abstract::There are several occurrences of thermal waters in the south-eastern part of Serbia, which are originating from igneous and metamorphic rocks. These waters are mainly used in balneology, but some of them are used for drinking purposes and in water supply to heat buildings, for greenhouses and to irrigate land. In this...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu094
更新日期:2014-07-01 00:00:00
abstract::Is atmospheric dispersion forecasting an important asset of the early-phase nuclear emergency response management? Is there a 'perfect atmospheric dispersion model'? Is there a way to make the results of dispersion models more reliable and trustworthy? While seeking to answer these questions the multi-model ensemble d...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch261
更新日期:2004-01-01 00:00:00
abstract::The purpose of the study was to evaluate the dose performance of a flat-panel (FP) and an image intensifier (II) charge coupled device (CCD) digital fluoroscopy X-ray systems newly installed in an Interventional Cardiology (IC) department. Filter entrance dose rate, detector dose rate (during fluoroscopy) and filter e...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch344
更新日期:2004-01-01 00:00:00
abstract::The study is aimed at optimising the glow curve structure of CaSO4:Dy phosphor for dosimetric purpose and also to understand the observed changes owing to thermal treatment in the thermoluminescence (TL) sensitivity and glow curve structure. The reversible changes in the intensities of the lower temperature satellite ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci561
更新日期:2006-01-01 00:00:00
abstract::This trial was undertaken to assess extremity dosemeters, which were made available to Devonport Royal Dockyard and determine the most suitable to the site. The trial included operational and laboratory-based exposures. Operational exposures were within a submarine reactor compartment and a waste storage area. Laborat...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn052
更新日期:2008-01-01 00:00:00
abstract::The use of a custom-made cylindrical graphite proportional counter (Cy-GPC) along with a cylindrical tissue equivalent proportional counter (TEPC) for neutron-gamma mixed-field dosimetry has been studied in the following steps: first, the consistency of the gamma dose measurement between the Cy-TEPC and the Cy-GPC was...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx291
更新日期:2018-08-01 00:00:00
abstract::From August 2016 to June 2017, the Public Health England-Centre for Radiation Chemical and Environmental Hazards (PHE-CRCE), collaborating centre of the WHO, through its Radiation Hazards and Emergencies Department Emergency Response Group has successfully supported five WHO Joint External Evaluation (JEE) missions in...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy142
更新日期:2018-12-01 00:00:00
abstract::Dosimetric monitoring and protection of the personnel involved into interventional procedures is one of the key issues nowadays, yet doses received by their brains were left without rigorous consideration so far. The paper is the fast track of the results of the pilot study of possible magnitude of operator's doses wi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw091
更新日期:2016-09-01 00:00:00
abstract::The diagnostic reference level (DRL) has generally been defined as the 75th percentile of the distributions of mean doses observed on a sample of standard-sized patients, but for mammography, the 95th percentile has been used. In this study, the 75th and 95th percentiles are estimated for 26 full-field digital mammogr...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct136
更新日期:2013-12-01 00:00:00
abstract::New paradigms for parallel programming have been devised to simplify software development on multi-core processors and many-core graphical processing units (GPU). Despite their obvious benefits, the parallelisation of existing computer programs is not an easy task. In this work, the use of the Open Multiprocessing (Op...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv430
更新日期:2016-06-01 00:00:00
abstract::The present study concerns measurements of radon emissions from soil carried out during March to July 2013 at Chite fault in Aizawl district, Mizoram, India. In this study, continuous radon monitoring in soil was done by using LR-115 type II nuclear track detector (Kodak-Pathe, France make), and the exposed films were...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu221
更新日期:2014-11-01 00:00:00
abstract::Biokinetic models are the scientific underpinning of internal dosimetry and depend, ultimately, for their scientific validation on comparisons with human bioassay data. Three significant plutonium/americium bioassay databases, known to the authors, are described: (1) Sellafield, (2) Los Alamos and (3) the United State...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm164
更新日期:2007-01-01 00:00:00
abstract::Tritium present in the environment gradually decreased in the last decades and nowadays it has reached extremely low activity concentrations. The purpose of the present work is the implementation of a tritium enrichment system in water samples using electrolytic techniques and pure nickel and iron electrodes. In the p...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp244
更新日期:2009-12-01 00:00:00
abstract::The use of high-energy linear electron accelerators (LINACs) for medical cancer treatments is widespread on an international scale. The associated bremsstrahlung X rays may produce neutrons as a result of subsequent photonuclear reactions with the different materials constituting the accelerator head. The generated ne...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm075
更新日期:2007-01-01 00:00:00
abstract::With the introduction of continuous-energy heavy charged particle transport in MCNP5, the need for tracking charged particles in a magnetic field becomes increasingly important. Two methods for including magnetic field effects on charged particles are included in the proton transport version of the code. The first tec...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci048
更新日期:2005-01-01 00:00:00
abstract::Kinetic simulations of the thermoluminescence characteristics of LiF:Mg, Ti are reviewed in the framework of conduction band/valence band models. Delocalised recombination models have been mainly applied to the simulation of glow peak shapes, although comparison with experimental data has proven difficult if not impos...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa209
更新日期:2021-01-13 00:00:00
abstract::To develop retrospective dosimetry of unexpected radiation accident, basic studies on violet thermoluminescence (VTL) phenomena were conducted using natural quartz grains. All VTL glowcurves of as-received samples did not exhibit peaks <250 degrees C, although for artificially irradiated quartz samples there were VTL ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl108
更新日期:2007-01-01 00:00:00
abstract::A high-end drum film digitiser (Tango, Germany) and a calibrated linear microdensitometer developed by PTB were used to assess the modulation transfer function (MTF) and the noise power spectra (NPS) of 3 mammographic screen film systems at optical density levels of 0.8, 1.5 and 2.5. The use of a drum scanner to asses...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch563
更新日期:2005-01-01 00:00:00
abstract::This study presents the seasonal variations of indoor radon levels in dwellings located in the Ramallah province and East Jerusalem suburbs, Palestine. The measurements were performed during the summer and winter of the year 2006/2007 using CR-39 solid-state-nuclear-track detectors. The total number of investigated bu...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr013
更新日期:2012-01-01 00:00:00
abstract::A new official albedo dosemeter based on thermoluminescent detectors has been introduced in 2015 by the individual monitoring service of the Helmholtz Zentrum München for monitoring persons who are exposed occupationally against photon and neutron radiation. To enhance the sensitivity for fast neutrons, a new badge wi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv406
更新日期:2016-09-01 00:00:00
abstract::To evaluate the environmental contamination and contributory external exposure after the accident at the Fukushima Nuclear Power Plant (FNPP), the concentrations of artificial radionuclides in soil samples from each area were analysed by gamma spectrometry. Six artificial radionuclides ((131)I, (134)Cs, (137)Cs, (129m...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs040
更新日期:2012-09-01 00:00:00
abstract::A widely used method in the planning of protective actions is to establish a stakeholder network to generate a comprehensive set of generic protective actions. The aim is to increase competence and build links for communication and coordination. The approach of this work was to systematically evaluate protective actio...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch258
更新日期:2004-01-01 00:00:00
abstract::The paper deals with the physical skull phantoms Bundesinstitut fuer Strahlenschutz and BPAM-001, which are used in order to calibrate in vivo detection systems for estimation of (241)Am activity in the skeleton. Their voxel models were made and used in the Monte Carlo simulations. The results of the simulation were c...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq491
更新日期:2011-03-01 00:00:00
abstract::Superlinear behaviour has been observed in dose dependence measurements of optically stimulated luminescence (OSL). Previous theoretical work has shown that superlinearity of the integral under the OSL decay curve may occur, resulting from competition with either radiationless luminescence centres or disconnected trap...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005938
更新日期:2002-01-01 00:00:00