Development and validation of a technique for the determination of 226Ra and 228Ra by liquid scintillation in liquid samples.

Abstract:

:Radium isotopes are dispersed in the environment according to their physicochemical characteristics. Considering their long half-lives and radiological effects, (226)Ra and (228)Ra are very important issues in radiological protection. In Brazil, radium isotopes represent an exposure problem both in nuclear fuel cycle installations and in high natural radiation background areas. The experimental part of this work includes the development of a technique for the determination of (226)Ra and (228)Ra by liquid scintillation with potential application in biological samples. Radium was concentrated and then separated from other constituents of the sample by co-precipitation/precipitation with Ba(Ra)SO(4). The precipitate was filtered and weighted to calculate the chemical yield. The filter containing the precipitate of Ba(Ra)SO(4) was transferred to a scintillation vial. Two methods were used to prepare the sources. The first one consisted of the addition of water (8 ml), Instagel XF (8 ml) and UltimaGold (4 ml) in the vial containing the filter and the precipitate, forming a gel suspension. In the second method, the precipitate was dissolved with 0.2 M ethylene-diamine-tetra-acetic-acid solution (9 ml) and 11 ml of scintillation solution (Optiphase Hisafe 3) was added to the vial, forming an aqueous and an organic phase. The solutions obtained were counted in a low background scintillation spectrometry system (Quantulus) suitable for the detection and identification of both alpha and beta particles for the determination of (226)Ra and (228)Ra. The activity values of (226)Ra and (228)Ra calculated by the two methods are in good agreement with the reference values, indicating that both methods are suitable for the determination of (226)Ra and (228)Ra.

journal_name

Radiat Prot Dosimetry

authors

Fernandes PC,Sousa WO,Julião LM,Dantas BM

doi

10.1093/rpd/ncq434

subject

Has Abstract

pub_date

2011-03-01 00:00:00

pages

335-8

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

ncq434

journal_volume

144

pub_type

杂志文章
  • AMANDE: a new facility for monoenergetic neutron fields production between 2 keV and 20 MeV.

    abstract::The variation of the response of the instruments with the neutron energy has to be determined in well-characterized monoenergetic neutron fields. The AMANDE facility will deliver such neutron fields between 2 keV and 20 MeV in an experimental hall designed with metallic walls for neutron scattering minimisation. The n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch185

    authors: Gressier V,Guerre-Chaley JF,Lacoste V,Lebreton L,Pelcot G,Pochat JL,Bolognese-Milstajn T,Champion D

    更新日期:2004-01-01 00:00:00

  • Nuclear theory for high-energy nuclear reactions of biomedical relevance.

    abstract::A full description of all possible nuclear reactions that take place in a macroscopic device can only be accomplished with a nuclear model code in combination with key experimental data. To address this issue, the authors demonstrate some of the capabilities of TALYS, a nuclear reaction program which simulates nuclear...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm008

    authors: Koning AJ,Duijvestijn MC

    更新日期:2007-01-01 00:00:00

  • COMPARISON OF DIFFERENT TECHNIQUES FOR EVALUATION OF DOSE DISTRIBUTIONS IN RADIOTHERAPY USING RADIOCHROMIC EBT3 FILMS.

    abstract::In radiotherapy, radiochromic films can be used for verification of delivery of dose distributions calculated by treatment planning systems. The main objective of this work was to compare three different techniques for evaluation of dose distributions for prostate cancer treatment plans using radiochromic EBT3 films. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz231

    authors: Dufek V,Horakova I,Koniarova I

    更新日期:2019-12-31 00:00:00

  • Relative implications of protective responses versus damage induction at low dose and low-dose-rate exposures, using the microdose approach.

    abstract::In reviewing the tissue effects of low-dose radiation (1) absorbed dose to tissue is replaced by the sum of energy deposited with track events in cell-equivalent tissue micromasses, i.e. with microdose hits, in the number of exposed micromasses and (2) induced cell damage and adaptive protection are related to microdo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006197

    authors: Feinendegen LE

    更新日期:2003-01-01 00:00:00

  • Sub-slab depressurisation systems used in the Czech Republic and verification of their efficiency.

    abstract::Design principles for sub-slab depressurisation systems recently used in the Czech Republic for remediating existing buildings are described. Results of an efficiency analysis performed on the basis of data from >60 single-family houses are presented. It was found out that the efficiency varies between 70 and 98 %, wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu219

    authors: Jiránek M

    更新日期:2014-11-01 00:00:00

  • PUBLIC HEALTH ENGLAND-CENTRE FOR RADIATION, CHEMICAL AND ENVIRONMENTAL HAZARDS (PHE-CRCE) EXTERNAL EXPERT EXPERIENCE IN THE JOINT EXTERNAL EVALUATION (JEE) MISSION FOR THE RADIATION EMERGENCIES TECHNICAL AREA.

    abstract::From August 2016 to June 2017, the Public Health England-Centre for Radiation Chemical and Environmental Hazards (PHE-CRCE), collaborating centre of the WHO, through its Radiation Hazards and Emergencies Department Emergency Response Group has successfully supported five WHO Joint External Evaluation (JEE) missions in...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy142

    authors: de Ruvo A,Cox D

    更新日期:2018-12-01 00:00:00

  • DOSIMETRIC PROPERTIES OF THE NEW TLD ALBEDO NEUTRON DOSEMETER AWST-TL-GD 04.

    abstract::A new official albedo dosemeter based on thermoluminescent detectors has been introduced in 2015 by the individual monitoring service of the Helmholtz Zentrum München for monitoring persons who are exposed occupationally against photon and neutron radiation. To enhance the sensitivity for fast neutrons, a new badge wi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv406

    authors: Haninger T,Henniger J

    更新日期:2016-09-01 00:00:00

  • Full spectrum analysis in environmental monitoring.

    abstract::In environmental radiation monitoring, the time-variable natural gamma radiation background complicates the nuclide identification and analysis of a gamma spectrum. A full spectrum analysis based on the noise adjusted singular value decomposition method for the description of the time-variable background and adjustmen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu144

    authors: Reinhardt S

    更新日期:2014-08-01 00:00:00

  • HOW DO HOSPITAL STERILISATION PROCEDURES AFFECT THE RESPONSE OF PERSONAL EXTREMITY RINGS AND OF EYE LENS TL DOSEMETERS?

    abstract::Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv539

    authors: Kopeć R,Bubak A,Budzanowski M,Sas-Bieniarz A,Szumska A

    更新日期:2016-09-01 00:00:00

  • Can default ICRP f1 values be applied to determine radiation dose from the intake of diet-incorporated thorium?

    abstract::Data on the daily urinary excretion of thorium (Th) was obtained from 15 non-exposed adult German subjects. A radiochemical neutron activation analysis method was developed and standardised especially for this purpose. The daily urinary excretion of 232Th was found to be in the range 1.9-14.9 microBq d(-1) with a mean...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch482

    authors: Höllriegl V,Li WB,Oeh U,Röhmuss M,Roth P

    更新日期:2005-01-01 00:00:00

  • Ten years of monitoring the occupational radiation exposure in Bosnia and Herzegovina.

    abstract::Monitoring of occupationally exposed persons in Bosnia and Herzegovina started in 1960s and it was interrupted in 1992. Dosimetry service resumed in 1999 when the International Atomic Energy Agency provided Harshaw 4500 TLD-reader and the first set of TLDs for the Radiation Protection Centre (RPC) of the Institute of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq006

    authors: Basić B,Beganović A,Samek D,Skopljak-Beganović A,Gazdić-Santić M

    更新日期:2010-04-01 00:00:00

  • Quality assurance (QA) procedures for software: evaluation of an ADC quality system.

    abstract::Image viewing and processing software in computed radiography manipulates image contrast in such a way that all relevant image features are rendered to an appropriate degree of visibility, and improves image quality using enhancement algorithms. The purpose of this study was to investigate procedures for the quality a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci742

    authors: Efstathopoulos EP,Benekos O,Molfetas M,Charou E,Kottou S,Argentos S,Kelekis NL

    更新日期:2005-01-01 00:00:00

  • Variation in indoor thoron levels in Mexico City dwellings.

    abstract::This paper presents the results obtained for thoron concentration in 50 single-family dwellings in normal occupancy conditions (open house conditions), measured by a passive electret system (type E-PERM, SSTB configuration) in a 2001-2002 monitoring survey in the Metropolitan Zone of Mexico City. The results show the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch371

    authors: Martinez T,Navarrete M,Gonzalez P,Ramírez A

    更新日期:2004-01-01 00:00:00

  • Radiation dose management in CT, SPECT/CT and PET/CT techniques.

    abstract::New imaging technologies utilising X rays and radiopharmaceuticals are continuously under development. The benefit of computed tomography (CT) has been so dramatic that there is a tendency to overuse it and not to place enough efforts into optimisation of the technique. It is also now more and more common to combine t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncr261

    authors: Mattsson S,Söderberg M

    更新日期:2011-09-01 00:00:00

  • High patient doses in interventional cardiology due to physicians' negligence: how can they be prevented?

    abstract::Interventional cardiology procedures are usually associated with high patient doses and even deterministic radiation effects may occur. Expensive digital flat panels are preferably used to lower doses, and Athens General Hospital has recently installed one. However, this study shows that it is the cardiologists' pract...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn005

    authors: Mavrikou I,Kottou S,Tsapaki V,Neofotistou V

    更新日期:2008-01-01 00:00:00

  • AUTOMATIC BRAIN DOSE ESTIMATION IN COMPUTED TOMOGRAPHY USING PATIENT DICOM IMAGES.

    abstract::This study aims to develop an Automatic Brain Dose Estimation (ABDE) methodology for head computed tomography examinations. The ABDE is to be applied first to an anthropomorphic Alderson phantom to obtain a Correction factor (Cf) between the ABDE and the direct absorbed brain dose using dosemeters positioned within th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa006

    authors: Gharbi S,Labidi S,Mars M

    更新日期:2020-07-02 00:00:00

  • Evaluation of occupational exposure to naturally occurring radioactive materials in the Iranian ceramics industry.

    abstract::Zircon contains small amounts of uranium, thorium and radium in its crystalline structure. The ceramic industry is one of the major consumers of zirconium compounds that are used as an ingredient at ∼10-20 % by weight in glaze. In this study, seven different ceramic factories have been investigated regarding the prese...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq441

    authors: Fathabadi N,Farahani MV,Amani S,Moradi M,Haddadi B

    更新日期:2011-06-01 00:00:00

  • INVESTIGATION OF EXTERNAL RADIATION DOSES DURING RESIDENTS' TEMPORAL STAY TO NAMIE TOWN, FUKUSHIMA PREFECTURE.

    abstract::Namie Town in Fukushima Prefecture, the majority of which was an evacuation area as a result of the effects of the Fukushima Daiichi Nuclear Power Plant accident, carried out a 'temporal stay' in September 2016 so that residents could check their houses. Therefore, in cooperation with the town authorities, the authors...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz107

    authors: Tsujiguchi T,Shiroma Y,Suzuki T,Tamakuma Y,Yamaguchi M,Iwaoka K,Hosoda M,Tokonami S,Kashiwakura I

    更新日期:2019-10-01 00:00:00

  • A high-sensitivity method for the measurement of 222Rn based on liquid scintillation counting of polycarbonate powder.

    abstract::This work describes a technique for the measurement of 222Rn by absorption in polycarbonate (PC) powder and liquid scintillation counting (LSC). The work is an improvement of the recently proposed method for 222Rn measurements by LSC of exposed PC grains. It is demonstrated that the use of PC powder as a 222Rn sampler...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu075

    authors: Mitev K,Georgiev S,Pressyanov D,Dimitrova I,Zhivkova V,Boshkova T

    更新日期:2014-07-01 00:00:00

  • DEVELOPMENT AND APPLICATION OF SOLID FORMS OF CaSO4:Dy THERMOLUMINESCENT DOSEMETERS IN RADIATION PROTECTION DOSIMETRY-A REVIEW.

    abstract::CaSO4:Dy is a reliable high-sensitive themoluminescent phosphor useful for low-level and high-level radiation measurements as it exhibits fading free linear dose response with a single glow peak at ~230°C in these dose regions. For large-scale radiation protection dosimetry service, it is embedded in Teflon matrix wit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncx287

    authors: Lakshmanan A

    更新日期:2018-10-01 00:00:00

  • Influence of the uniformity of the slab phantom illumination on the calibration of personal dosemeters.

    abstract::For the calibration of personal dosemeters in terms of H(p)(10), the ISO water slab phantom shall be used. The irradiation geometry must be chosen such that the field diameter at the phantom front surface is large enough to irradiate the phantom completely and, in addition, homogeneously. However, in practice it is no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq036

    authors: Ankerhold U,Ambrosi P

    更新日期:2010-06-01 00:00:00

  • A large-scale measurement, analysis and modelling of electromagnetic radiation levels in the vicinity of GSM/UMTS base stations in an urban area.

    abstract::The present study analyses the electric field radiating from the GSM/UMTS base stations located in central Malatya, a densely populated urban area in Turkey. The authors have conducted both instant and continuous measurements of high-frequency electromagnetic fields throughout their research by using non-ionising radi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv008

    authors: Karadağ T,Yüceer M,Abbasov T

    更新日期:2016-01-01 00:00:00

  • Indoor radon levels in primary schools of Patras, Greece.

    abstract::Radon activity concentrations have been measured in 53 from a total of 66 public primary schools throughout of Patras, Greece, during December 1999 to May 2000 using solid-state nuclear track detectors (LR-115 II). The indoor radon levels in the classrooms were generally low, ranging from 10 to 89 Bqm(-3). The mean (a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm180

    authors: Papaefthymiou H,Georgiou CD

    更新日期:2007-01-01 00:00:00

  • Luminescence dosimetry using building materials and personal objects.

    abstract::There is a growing public awareness of the risk of accidental radiation exposure due to ageing nuclear power installations, illegal dumping of nuclear waste and terrorist activities, and of the consequential health risks to populations in addition to social and economic disturbance extending beyond national boundaries...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci699

    authors: Göksu HY,Bailiff IK

    更新日期:2006-01-01 00:00:00

  • Dose effect for South Serbians due to 238U in natural drinking water.

    abstract::The use of depleted uranium ammunition in South Serbia during the 1999 Kosovo conflict raised a great deal of public concern in the Balkans. Radioactivity levels of 238U in 20 wells and lake water samples were checked from the viewpoint of internal radiation exposure for South Serbian subjects. We have measured 238U c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm294

    authors: Sahoo SK,Matsumoto M,Shiraishi K,Fujimoto K,Cuknic O,Zunic ZS

    更新日期:2007-01-01 00:00:00

  • Numerical solution of the transport equation describing the radon transport from subsurface soil to buildings.

    abstract::A theoretical evaluation of the properties and processes affecting the radon transport from subsurface soil into buildings is presented in this work. The solution of the relevant transport equation is obtained using the explicit finite difference method (EFDM). Results are compared with analytical steady-state solutio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr397

    authors: Savović S,Djordjevich A,Ristić G

    更新日期:2012-06-01 00:00:00

  • Low air exchange rate causes high indoor radon concentration in energy-efficient buildings.

    abstract::Since 1995, requirements on energy-efficient building construction were established in Russian Building Codes. In the course of time, utilisation of such technologies became prevailing, especially in multi-storey building construction. According to the results of radon survey in buildings constructed meeting new requi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv319

    authors: Vasilyev AV,Yarmoshenko IV,Zhukovsky MV

    更新日期:2015-06-01 00:00:00

  • Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation.

    abstract::Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equiv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005933

    authors: Yasuda H,Fujitaka K

    更新日期:2002-01-01 00:00:00

  • Blood tritium level as an estimate of soft tissue dose.

    abstract::To test the blood tritium level as an estimate of free water tritium (FWT) and organically bound tritium (OBT) in human soft tissues, a tritiated amino acid mixture (TAA) and tritiated water (HTO) were injected or orally administered to mice. Relatively high tritium retention in the blood was found after TAA injection...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006272

    authors: Saito M

    更新日期:2003-01-01 00:00:00

  • The measurements of thoron, radon and their decay products thanks to Pinocchio, Tengu and Trolls.

    abstract::In the present paper, the long noses of Pinocchio, Tengu and Trolls are used to measure, respectively, radon, thoron, and their decay products both by track-etch detectors and by Geiger-Müller (G-M) counters. Just recently, four new passive samplers (termed quatrefoil) have been developed which greatly simplify the de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq248

    authors: Tommasino L,Tokonami S,Tommasino PM

    更新日期:2010-10-01 00:00:00