DEVELOPMENT AND APPLICATION OF SOLID FORMS OF CaSO4:Dy THERMOLUMINESCENT DOSEMETERS IN RADIATION PROTECTION DOSIMETRY-A REVIEW.

Abstract:

:CaSO4:Dy is a reliable high-sensitive themoluminescent phosphor useful for low-level and high-level radiation measurements as it exhibits fading free linear dose response with a single glow peak at ~230°C in these dose regions. For large-scale radiation protection dosimetry service, it is embedded in Teflon matrix with varying thicknesses. Extensive studies have been carried out with such CaSO4:Dy Teflon discs in individual and environmental radiation monitoring applications including its capability to measure International Commission on Radiation Units and Measurements operational quantities. The review highlights their development and application in high-energy photon measurements, thin wafers and graphite-loaded Teflon discs for beta-dosimetry, phosphor-filled aluminium discs for high-dose applications, 6LiF-mixed CaSO4:Dy Teflon discs for thermal and albedo or moderated fast neutrons, sulphur-mixed CaSO4:Dy pellets for fast-neutron exposure even in the presence of gamma-rays and polyethylene-mixed CaSO4:Dy discs for fast neutrons.

journal_name

Radiat Prot Dosimetry

authors

Lakshmanan A

doi

10.1093/rpd/ncx287

subject

Has Abstract

pub_date

2018-10-01 00:00:00

pages

57-99

issue

2

eissn

0144-8420

issn

1742-3406

pii

5102505

journal_volume

181

pub_type

杂志文章,评审
  • Review of retrospective dosimetry techniques for external ionising radiation exposures.

    abstract::The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by indivi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncq499

    authors: Ainsbury EA,Bakhanova E,Barquinero JF,Brai M,Chumak V,Correcher V,Darroudi F,Fattibene P,Gruel G,Guclu I,Horn S,Jaworska A,Kulka U,Lindholm C,Lloyd D,Longo A,Marrale M,Monteiro Gil O,Oestreicher U,Pajic J,Rakic B

    更新日期:2011-11-01 00:00:00

  • In vivo thyroid 131I monitoring system using an imaging plate.

    abstract::The counting efficiency and detection limit of an in vivo thyroid 131I monitoring system using an imaging plate (IP) were estimated using an anthropomorphic thyroid neck phantom. The counting efficiency of the IP system was approximately constant for thyroid volumes between 11.7 and 20 ml and neck diameters between 10...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006025

    authors: Hirota M,Saze T,Nishizawa K

    更新日期:2002-01-01 00:00:00

  • Assessment of effective dose in paediatric CT examinations.

    abstract::Current concerns focus on the high doses encountered in computed tomography (CT) examinations as they are extending towards younger and more radiosensitive patients. Previous work produced conversion coefficients for effective dose (E) from dose-length product (DLP) for four anatomical body regions applicable to any p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr288

    authors: Dougeni E,Chapple CL,Willis J,Panayiotakis G

    更新日期:2011-09-01 00:00:00

  • Determination of diagnostic reference levels in general radiography in Latin America.

    abstract::The International Atomic Energy Agency (IAEA) through the International Action Plan on Radiation Protection of Patients and the International Commission on Radiological Protection have for some time carried out important efforts to assure that in the medical applications of the ionising radiations, the optimisation of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct069

    authors: Blanco S,Mora P,Almonte N,Benavente T,Benson N,Blanco D,Cárdenas J,Defaz Gómez Y,Edding O,Escobar C,Fonseca M,Gamarra M,García Aguilar J,Khoury HJ,Quintero AR,Roas Zuniga N,Zaire E,Nader A

    更新日期:2013-09-01 00:00:00

  • Low-cost extrapolation method for maximal LTE radio base station exposure estimation: test and validation.

    abstract::An experimental validation of a low-cost method for extrapolation and estimation of the maximal electromagnetic-field exposure from long-term evolution (LTE) radio base station installations are presented. No knowledge on downlink band occupation or service characteristics is required for the low-cost method. The meth...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs307

    authors: Verloock L,Joseph W,Gati A,Varsier N,Flach B,Wiart J,Martens L

    更新日期:2013-06-01 00:00:00

  • Radiation exposure to the population of Europe following the Chernobyl accident.

    abstract::On the occasion of the 20th anniversary of the Chernobyl accident an attempt has been made to evaluate the impact of the Chernobyl accident on the global burden of human cancer in Europe. This required the estimation of radiation doses in each of the 40 European countries. Dose estimation was based on the analysis and...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl528

    authors: Drozdovitch V,Bouville A,Chobanova N,Filistovic V,Ilus T,Kovacic M,Malátová I,Moser M,Nedveckaite T,Völkle H,Cardis E

    更新日期:2007-01-01 00:00:00

  • DOSE ASSESSMENT OF NATURAL TERRESTRIAL RADIONUCLIDES IN COMMONLY CONSUMED FOODS IN NORTH INDIA.

    abstract::The present study aimed to record natural radionuclide content in branded food samples representative of a typical North Indian diet. Forty samples of various food items falling into three categories namely, cereal grains, pulses and beverages were collected from the local markets of Punjab. The radiometric analysis w...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa050

    authors: Kaur S,Maheshwari P,Mehra R

    更新日期:2020-07-17 00:00:00

  • Occurrence of natural radioactivity in public water supplies in Germany: (238)U, (234)U, (235)U, (228)RA, (226)RA, (222)RN, (210)PB, (210)PO and gross alpha activity concentrations.

    abstract::The Federal Office for Radiation Protection performed a representative survey on the radiological quality of drinking water in Germany. The aim of this study was to determine regional variations of natural radionuclide concentrations and to estimate radiation exposures caused by drinking water consumption. The study i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq139

    authors: Beyermann M,Bünger T,Schmidt K,Obrikat D

    更新日期:2010-09-01 00:00:00

  • CHARACTERISATION AND EVALUATION OF AL2O3:C-BASED OPTICALLY STIMULATED LUMINESCENT DOSEMETER SYSTEM FOR DIAGNOSTIC X-RAYS: PERSONAL AND IN VIVO DOSIMETRY.

    abstract::This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reade...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz186

    authors: Wong JHD,Bakhsh M,Cheah YY,Jong WL,Khor JS,Ng KH

    更新日期:2019-12-31 00:00:00

  • Thermoluminescent dosemeters based on TLD-500 detectors for control of neutron fields.

    abstract::The results of a study dealing with detection of neutrons in thermoluminescent (TL) photon radiation detectors, type TLD-500, based on an anion-defective corundum have been reported. The detection method uses the transformation of neutron radiation into gamma radiation arising when neutrons are captured by cadmium nuc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005951

    authors: Nikiforov SV,Kortov VS,Milman II

    更新日期:2002-01-01 00:00:00

  • Contribution of different foodstuffs to the internal exposure of rural inhabitants in Russia after the Chernobyl accident.

    abstract::In a large village, Veprin of the Bryansk region of Russia contaminated with radionuclides as a result of the Chernobyl accident, 137Cs concentration in food products of agricultural produce and natural origin was regularly measured, local inhabitants were polled on the composition of their diet, and the 137Cs content...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006445

    authors: Travnikova IG,Bruk GJ,Shutov VN,Bazjukin AB,Balonov MI,Rahola T,Tillander M

    更新日期:2001-01-01 00:00:00

  • Long-term measurements of radon equilibrium factor in Greek dwellings.

    abstract::The time variation of the radon equilibrium factor F was measured every four hours in the Nuclear Technology Laboratory of the Aristotle University of Thessaloniki (in northern Greece) during October 1998-April 1999. The time dependence of the mean weekly value of radon equilibrium factor F is relatively small. During...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006143

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2003-01-01 00:00:00

  • Insights into the sites of X ray and neutron induced chromosomal aberrations in human lymphocytes using COBRA-MFISH.

    abstract::A multi-colour fluorescence in situ hybridisation (MFISH) assay has been developed, for simultaneous visualisation of all human chromosomes in 24 different colours. This assay is based on the simultaneous use of combinatorial labelling and ratio labelling, the so called combined binary ratio labelling (COBRA). This te...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006758

    authors: Darroudi F,Bezrookove V,Fomina J,Mesker WE,Wiegant JC,Raap AK,Tanke HJ

    更新日期:2002-01-01 00:00:00

  • 226Ra, 222Rn AND PERMEABILITY OF BELGIAN SOILS IN RELATION WITH INDOOR RADON RISK.

    abstract::Knowing the concentration of 226Ra in soil and of 222Rn in soil gas is important for the analysis of indoor radon data and the prediction of radon-prone areas. Except for soil Rn in Ardenne, the data concerning these two radionuclides in Belgian soils are very scarce. In the context of Master theses and international ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx163

    authors: Licour C,Tondeur F,Gerardy I,Alaoui NM,Dubois N,Perreaux R,Gerardy N,Christiaens D

    更新日期:2017-11-01 00:00:00

  • Relative radiological risks derived from different TENORM wastes in Malaysia.

    abstract::In Malaysia technologically enhanced naturally occurring radioactive materials (TENORM) wastes are mainly the product of the oil and gas industry and mineral processing. Among these TENORM wastes are tin tailing, tin slag, gypsum and oil sludge. Mineral processing and oil and gas industries produce large volume of TEN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq577

    authors: Ismail B,Teng IL,Muhammad Samudi Y

    更新日期:2011-11-01 00:00:00

  • Individual monitoring in mixed neutron/photon fields using a single silicon detector.

    abstract::A device based on a single silicon detector of special converter/detector design optimised for the determination of the neutron dose equivalent is also used for the determination of the photon dose equivalent. While the neutron dose is determined on the basis of signals corresponding to energy depositions above 1.5 Me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005962

    authors: Luszik-Bhadra M

    更新日期:2002-01-01 00:00:00

  • THE IMPACT OF CIRCADIAN RHYTHMS ON MEDICAL IMAGING AND RADIOTHERAPY REGIMES FOR THE PAEDIATRIC PATIENT.

    abstract::Daily rhythmic changes are found in cellular events in cell cycle, DNA repair, apoptosis and angiogenesis in both normal and tumour tissue, as well as in enzymatic activity and drug metabolism. In this paper, we hypothesize that circadian rhythms need to be considered in radiation protection and optimization in person...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw328

    authors: Forssell-Aronsson E,Quinlan RA

    更新日期:2017-04-01 00:00:00

  • CHARACTERIZATION OF 27 MEV PROTON BEAM GENERATED BY TOP-IMPLART LINEAR ACCELERATOR.

    abstract::The first proton linear accelerator for tumor therapy based on an actively scanned beam up to the energy of 150 MeV, is under development and construction by ENEA-Frascati, ISS and IFO, under the Italian TOP-IMPLART project. Protons up to the energy of 7 MeV are generated by a customized commercial injector operating ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy001

    authors: De Angelis C,Ampollini A,Basile E,Cisbani E,Della Monaca S,Ghio F,Montereali RM,Picardi L,Piccinini M,Placido C,Ronsivalle C,Soriani A,Strigari L,Trinca E,Vadrucci M

    更新日期:2018-08-01 00:00:00

  • APPLICABILITY OF AUTONOMOUS UNMANNED HELICOPTER SURVEY OF AIR DOSE RATE IN SUBURBAN AREA.

    abstract::An autonomous unmanned helicopter (AUH) survey is a useful tool for monitoring the distribution of ambient dose equivalent rates. However, the AUH survey method was developed for plane permeable fields such as agricultural land, and its applicability to urban areas is unclear. In this study, the applicability was inve...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz116

    authors: Yoshimura K,Fujiwara K,Nakama S

    更新日期:2019-10-01 00:00:00

  • Radiation dose management in CT, SPECT/CT and PET/CT techniques.

    abstract::New imaging technologies utilising X rays and radiopharmaceuticals are continuously under development. The benefit of computed tomography (CT) has been so dramatic that there is a tendency to overuse it and not to place enough efforts into optimisation of the technique. It is also now more and more common to combine t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncr261

    authors: Mattsson S,Söderberg M

    更新日期:2011-09-01 00:00:00

  • Radiation Protection Studies for Medical Particle Accelerators using Fluka Monte Carlo Code.

    abstract::Radiation protection (RP) in the use of medical cyclotrons involves many aspects both in the routine use and for the decommissioning of a site. Guidelines for site planning and installation, as well as for RP assessment, are given in international documents; however, the latter typically offer analytic methods of calc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw302

    authors: Infantino A,Cicoria G,Lucconi G,Pancaldi D,Vichi S,Zagni F,Mostacci D,Marengo M

    更新日期:2017-04-01 00:00:00

  • Application of a CZT detector to in situ environmental radioactivity measurement in the Fukushima area.

    abstract::Instead of conventional Ge semiconductor detectors and NaI(Tl) scintillation spectrometers, an application of a CdZnTe semiconductor (CZT) whose crystal has the dimension of 1 cm cubic to the in situ environmental radioactivity measurement was attempted in deeply affected areas in Fukushima region. Results of depositi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv277

    authors: Kowatari M,Kubota T,Shibahara Y,Fujii T,Fukutani S,Takamiya K,Mizuno S,Yamana H

    更新日期:2015-11-01 00:00:00

  • Calculation and Validation of the Response Matrix for a Neutron Multisphere Spectrometer with an Indium Central Detector.

    abstract::Expansion of accelerator technologies into different application areas brings the need for neutron-field measurements in their vicinity. The measurements of neutron energy spectra and neutron dose rates can be done with the aid of neutron multisphere spectrometers with passive neutron detectors. In addition to the usu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx183

    authors: Vlk P,Pavlovic M

    更新日期:2018-04-01 00:00:00

  • Indoor radon measurements in the dwellings of Punjab and Himachal Pradesh, India.

    abstract::The measurement of indoor radon concentrations were performed in the dwellings of the Punjab and Himachal Pradesh, India by using LR-115 type II Solid-State Nuclear Track Detectors in the bare mode. The annual average indoor radon concentrations in the dwellings are found to vary from 114 to 400 Bq m(-3) with an avera...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct041

    authors: Rani A,Singh S,Duggal V

    更新日期:2013-01-01 00:00:00

  • Sub-slab depressurisation systems used in the Czech Republic and verification of their efficiency.

    abstract::Design principles for sub-slab depressurisation systems recently used in the Czech Republic for remediating existing buildings are described. Results of an efficiency analysis performed on the basis of data from >60 single-family houses are presented. It was found out that the efficiency varies between 70 and 98 %, wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu219

    authors: Jiránek M

    更新日期:2014-11-01 00:00:00

  • RADIOECOLOGICAL IMPACT AND THE ASSOCIATED HAZARDS DUE TO NORM FROM OIL AND GAS PRODUCTION FACILITY IN THE WESTERN DESERT OF EGYPT.

    abstract::An oil and gas production facility in the western desert of Egypt was investigated for possible radiation risks due to the routine operation. Radium-226, Radium-228 and Potassium-40 were assessed in the soil samples collected from the adjacent soakaway pond. The average 226Ra, 228Ra and 40K activity concentrations wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa084

    authors: Ebaid YY,Hassan Y,Elshemey WM

    更新日期:2020-08-28 00:00:00

  • Internal dosimetry verification and validation database.

    abstract::Simulated-data internal dosimetry cases for use in intercomparison exercises or as a software verification and validation tool have been published on the internet (www.lanl.gov/bayesian/software Bayesian software package II). A user may validate their internal dosimetry code or method using this simulated bioassay dat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm470

    authors: Miller G,Bertelli L,Little T,Guilmette RA

    更新日期:2007-01-01 00:00:00

  • OCCUPATIONAL DOSE DURING ADULT INTERVENTIONAL CARDIOLOGY: FIRST VALUES WITH PERSONAL ACTIVE DOSIMETERS IN CHILE.

    abstract::The objective of this article is to present initial occupational dose values using digital active personal dosimeters for medical staff during adult interventional cardiology procedures in a public hospital in Chile. Personal dose equivalent Hp(10) over the lead apron of physician, nurse and radiographer were measured...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy057

    authors: Ubeda C,Morales C,Gutiérrez D,Oliveira M,Manterola C

    更新日期:2018-12-01 00:00:00

  • Evaluation of radionuclide concentrations and associated radiological hazard indexes in building materials used in Egypt.

    abstract::Radionuclide concentrations of ²²⁶Ra, ²³²Th and ⁴⁰K in different types of building materials used in Egypt were measured using gamma-ray spectroscopy. The results showed relatively moderate radionuclide concentrations for all samples except granite, which showed extremely high concentrations of 78.75 ± 2.36, 2.82 ± 0....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct129

    authors: Hassan NM,Mansour NA,Fayez-Hassan M

    更新日期:2013-12-01 00:00:00

  • Evaluation of the performance of two LiF:Mg,Ti and LiF:Mg,Cu,P dosemeters for extremity monitoring.

    abstract::In this paper, the results aimed at assessing the performance of two varieties of LiF detectors (LiF:Mg,Ti and LiF:Mg,Cu,P) in photon fields relatively to reproducibility, detection threshold and angular dependence as defined in the ISO 12794 standard are presented. The fading properties and the limit of detection wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq366

    authors: Freire LC,Pereira MF,Calado AM,Santos LM,Cardoso JV,Alves JG

    更新日期:2011-03-01 00:00:00