Regional cooperation in RWM in the AO countries.

Abstract:

:Regional cooperation in radioactive waste management (RWM) in the Asian and Oceanic countries has been successfully developing for more than 20 y. At present, the Asian and Oceanic countries recognise that there are several projects under the regional cooperation, such as the Forum for Nuclear Cooperation in Asia (FNCA), the Asian Nuclear Safety Network (ANSN) and the International Atomic Energy Agency (IAEA) regional projects. The FNCA on Radiation Safety and RWM is an effective mechanism for enhancing socio-economic development through active regional partnership in the peaceful and safe utilisation of nuclear technology. The ANSN Topical Group on RWM is established for exchanging, pooling, and sharing knowledge in the field of nuclear safety. For IAEA regional cooperation on RWM, such as IAEA-regional project RAS/3/009 Strengthening Infrastructure of RWM can provide and support Asian and Oceanic countries for national work plan, fellowships and scientific visits as well as expert services.

journal_name

Radiat Prot Dosimetry

authors

Ya-anant N,Thiangtrongjit S

doi

10.1093/rpd/ncr124

subject

Has Abstract

pub_date

2011-07-01 00:00:00

pages

148-50

issue

1-3

eissn

0144-8420

issn

1742-3406

pii

ncr124

journal_volume

146

pub_type

杂志文章
  • Radiation-induced micronucleus frequencies in female peripheral blood lymphocytes collected during the first and second half of the menstrual cycle.

    abstract::Biological dosimetry relies on the assessment of dose in peripheral blood lymphocytes (PBL) of a victim. Variability in the individual radiosensitivity of PBL has an impact on the precision of dose estimate and radiation-induced micronuclei show a strong individual variability. A factor which can influence the radiose...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl545

    authors: Krol M,Lankoff A,Buraczewska I,Derezinska E,Wojcik A

    更新日期:2007-01-01 00:00:00

  • Would children be adequately protected by existing intervention levels during a radionuclear emergency?

    abstract::The question arises as to whether radiation standards and guidelines set for adults are sufficiently protective of children. To answer this question, published literature values have been used to calculate radiation doses to children and adults from external and internal exposure to a suite of 30 radionuclides commonl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq202

    authors: Tracy BL

    更新日期:2010-11-01 00:00:00

  • Detection system built from commercial integrated circuits for real-time measurement of radiation dose and quality using the variance method.

    abstract::A small, specialised amplifier using commercial integrated circuits (ICs) was developed to measure radiation dose and quality in real time using a microdosimetric ion chamber and the variance method. The charges from a microdosimetric ion chamber, operated in the current mode, were repeatedly collected for a fixed per...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm231

    authors: Hsu WH,Braby LA,Reece WD

    更新日期:2008-01-01 00:00:00

  • Uranium isotopes in public drinking water and dose assessment for man in Poland.

    abstract::238U, 234U and 235U were determined in tap water from municipal water pipes that drew their supply from surface water or ground water in various locations in Poland. Average activity concentrations of 238U, 234U and 235U in tap water from surface water were 9.6 +/- 7.1, 12.8 +/- 9.7 and 0.41 +/- 0.31 Bq m(-3), respect...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch425

    authors: Pietrzak-Flis Z,Kaminska I,Chrzanowski E

    更新日期:2005-01-01 00:00:00

  • Studies of patient doses in interventional radiological examinations.

    abstract::In Russia, especially in big cities like St. Petersburg, the annual number of interventional radiological (IR) examinations for both diagnostic and treatment purposes is increasing continuously. However, IR examinations might involve high patient doses and even the risk of skin injures that should be prevented. In thi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncq021

    authors: Sarycheva S,Golikov V,Kalnicky S

    更新日期:2010-04-01 00:00:00

  • Radiation safety assessment of a system of small reactors for distributed energy.

    abstract::A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, dee...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci208

    authors: Odano N,Ishida T

    更新日期:2005-01-01 00:00:00

  • MEASUREMENT OF THE POTENTIAL ALPHA ENERGY CONCENTRATION OF RADON PROGENY BY USING LIQUID SCINTILLATION COUNTING METHOD.

    abstract::For more accurate measurement of the potential alpha energy concentration (PAEC) of radon progeny by the liquid scintillation counting (LSC) method, its counting efficiency was studied in this work. A radon progeny standard source was used to provide different concentrations of radon progeny, and the progeny collected...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz069

    authors: Feng B,Tang Q,Zhang H,Chen B,Qiu S,Zhuo W

    更新日期:2019-10-01 00:00:00

  • Overview of two years of clinical experience of chest tomosynthesis at Sahlgrenska University Hospital.

    abstract::Since December 2006, approximately 3800 clinical chest tomosynthesis examinations have been performed at our department at Sahlgrenska University Hospital. A subset of the examinations has been included in studies of the detectability of pulmonary nodules, using computed tomography (CT) as the gold standard. Visibilit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq059

    authors: Johnsson AA,Vikgren J,Svalkvist A,Zachrisson S,Flinck A,Boijsen M,Kheddache S,Månsson LG,Båth M

    更新日期:2010-04-01 00:00:00

  • CHARACTERISATION AND EVALUATION OF AL2O3:C-BASED OPTICALLY STIMULATED LUMINESCENT DOSEMETER SYSTEM FOR DIAGNOSTIC X-RAYS: PERSONAL AND IN VIVO DOSIMETRY.

    abstract::This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reade...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz186

    authors: Wong JHD,Bakhsh M,Cheah YY,Jong WL,Khor JS,Ng KH

    更新日期:2019-12-31 00:00:00

  • Suggested diagnostic reference levels for paediatric X-ray examinations in India.

    abstract::Exposure of children to ionising radiation is considered to carry higher risk than that of adults; therefore a need to suggest diagnostic reference levels (DRLs) for the common paediatric diagnostic X-ray procedures was recognised for the X-ray machines meeting the requirements of the recently implemented Safety Code ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq458

    authors: Sonawane AU,Sunil Kumar JV,Singh M,Pradhan AS

    更新日期:2011-11-01 00:00:00

  • Magnetic field tracking with MCNP5.

    abstract::With the introduction of continuous-energy heavy charged particle transport in MCNP5, the need for tracking charged particles in a magnetic field becomes increasingly important. Two methods for including magnetic field effects on charged particles are included in the proton transport version of the code. The first tec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci048

    authors: Bul JS,Hughes HG,Walstrom PL,Zumbro JD,Mokhov NV

    更新日期:2005-01-01 00:00:00

  • Patient dose in digital projection radiography.

    abstract::In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and direct radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Radiology Emergency Department of our hospital, a flat-panel DR equipment (Siemens Axiom Ari...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn013

    authors: Compagnone G,Pagan L,Baleni MC,Calzolaio FL,Barozzi L,Bergamini C

    更新日期:2008-01-01 00:00:00

  • An in vitro L-band electron paramagnetic resonance study of highly irradiated whole teeth.

    abstract::Regarding in vivo L-band dosimetry with human teeth, a number of preliminary experiments were carried out that were linked to the resonators response and the relative contribution of enamel to the EPR signal intensity of irradiated whole teeth. The sensitivity of the extended loop resonator varies in the antenna plane...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006036

    authors: Zdravkova M,Wieser A,El-Faramawy N,Gallez B,Debuyst R

    更新日期:2002-01-01 00:00:00

  • Radon concentration measurements in bituminous coal mines.

    abstract::Radon measurements were carried out in Kozlu, Karadon and Uzülmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch449

    authors: Fisne A,Okten G,Celebi N

    更新日期:2005-01-01 00:00:00

  • ORGANIC SCINTILLATOR FOR REAL-TIME NEUTRON DOSIMETRY.

    abstract::We developed a radiation detector based on an organic scintillator for spectrometry and dosimetry of out-of-field secondary neutrons from clinical proton beams. The detector consists of an EJ-299-34 crystalline organic scintillator, coupled by fiber optic cable to a silicon photomultiplier (SiPM). Proof of concept mea...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx255

    authors: Beyer KA,Di Fulvio A,Stolarczyk L,Parol W,Mojzeszek N,Kopéc R,Clarke SD,Pozzi SA

    更新日期:2018-08-01 00:00:00

  • Radiation doses in cerebral perfusion computed tomography: patient and phantom study.

    abstract::The purpose of this study was to investigate radiation doses in cerebral perfusion computed tomography (CT) examination. As a part of routine patient monitoring, data were collected on patients in terms of the skin dose and CT dose index (CTDIvol) and dose-length product (DLP) values. For the estimation of the dose to...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs260

    authors: Arandjic D,Bonutti F,Biasizzo E,Ciraj-Bjelac O,Floreani M,Giustizieri M,Iaiza F,Inkoom S,Tommasini G,Padovani R

    更新日期:2013-05-01 00:00:00

  • ESTIMATION OF ORGAN DOSES AMONG DIAGNOSTIC MEDICAL RADIATION WORKERS IN SOUTH KOREA.

    abstract::This study aimed to estimate the radiation organ doses from occupational exposure in 94 396 Korean medical radiation workers. Data on badge doses (i.e. personal dose equivalent at 10 mm) between 1996 and 2011 obtained from a national dosimetry registry, survey data from 2012 to 2013, and organ dose conversion coeffici...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx239

    authors: Choi Y,Shil Cha E,Jin Bang Y,Ko S,Ha M,Lee C,Jin Lee W

    更新日期:2018-04-01 00:00:00

  • Accreditation in radiation protection for cardiologists and interventionalists.

    abstract::Training in radiation protection is widely recognised as one of the basic components of optimisation programmes for medical exposures. Occupational and patient radiation risks in interventional radiology can be quite high and international bodies have shown concern on this item. Following recommendations of the Intern...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci730

    authors: Vano E,Gonzalez L

    更新日期:2005-01-01 00:00:00

  • Active neutron dosemeters based on microdosimetric principles: research studies.

    abstract::Over the past few years, the Institute for Radiation Protection and Nuclear Safety (IRSN) has been studying a personal electronic neutron dosemeter and an ambient electronic neutron dosemeter based on experimental microdosimetric principles using low pressure proportional counters. The results obtained in 2000 and in ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006808

    authors: Ménard S,Chau Q,Lahaye T

    更新日期:2002-01-01 00:00:00

  • Implementation of the new international standards in Swiss legislation on radon protection in dwellings.

    abstract::The current revision of the Swiss Radiological Protection Ordinance aims to bring Swiss legislation in line with new international standards. In future, the control of radon exposure in dwellings will be based on a reference level of 300 Bq m(-3). Since this value is exceeded in >10 % of the buildings so far investiga...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu307

    authors: Palacios Gruson M,Barazza F,Murith C,Ryf S

    更新日期:2015-04-01 00:00:00

  • Ten years of monitoring the occupational radiation exposure in Bosnia and Herzegovina.

    abstract::Monitoring of occupationally exposed persons in Bosnia and Herzegovina started in 1960s and it was interrupted in 1992. Dosimetry service resumed in 1999 when the International Atomic Energy Agency provided Harshaw 4500 TLD-reader and the first set of TLDs for the Radiation Protection Centre (RPC) of the Institute of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq006

    authors: Basić B,Beganović A,Samek D,Skopljak-Beganović A,Gazdić-Santić M

    更新日期:2010-04-01 00:00:00

  • Personal radon dosimetry from eyeglass lenses.

    abstract::Eyeglass lenses are commonly composed of allyl-diglycol carbonate (CR-39), an alpha-particle detecting plastic, thus making such lenses personal radon dosemeters. Samples of such lenses have been obtained, etched to reveal that radon and radon progeny alpha tracks can be seen in abundance, and sensitivities have been ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006670

    authors: Fleischer RL,Meyer NR,Hadley SA,MacDonald J,Cavallo A

    更新日期:2001-01-01 00:00:00

  • A SIMULATION STUDY OF DEPOSITION PARAMETERS FOR 129I DISCHARGED FROM THE ROKKASHO REPROCESSING PLANT.

    abstract::The first commercial spent nuclear fuel reprocessing plant at Rokkasho in Japan discharged 129I from actual spent nuclear fuel into the atmosphere during its test operation from 2006 to 2008. Previously, we measured monthly atmospheric concentrations of gaseous and particulate 129I and atmospheric deposition rates of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz061

    authors: Abe K,Hasegawa H,Akata N,Kakiuchi H,Chiang JH,Suwa H,Hisamatsu S

    更新日期:2019-10-01 00:00:00

  • Assessment of radiation doses to Australian participants in British nuclear tests.

    abstract::Between 1952 and 1957, the UK exploded a total of 12 nuclear devices in Australia, and also conducted about 600 'minor trials' that did not involve a nuclear explosion. Over 16 000 Australian servicemen and civilians were involved in the UK tests in Australia. This paper reports the estimation of doses that the Austra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp164

    authors: Crouch P,Robotham FR,Williams G,Wise K

    更新日期:2009-09-01 00:00:00

  • THE CHALLENGE IN USING THE RETROSPECTIVE ASSESSMENT OF RESIDENTIAL RADON CONCENTRATION.

    abstract::In the present study, the contemporary indoor radon activity concentration and the surface-deposited 210Po activity were measured in 65 Romanian dwellings. The activity of trapped 210Po on the glass surface was measured using the (CR-LR) difference technique. The retrospective radon activity concentration estimated on...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy095

    authors: Dicu T,Burghele BD,Lupulescu D,Cucos A

    更新日期:2018-09-01 00:00:00

  • Defect complexes in Re3+-doped magnesium sulphate phosphors.

    abstract::A series of magnesium sulphate phosphors MgSO4:RE3+,X ( RE = Dy, Tm, Eu and X = P, Mn) have been prepared and studied. Based on the experimental results of thermoluminescence (TL) emission spectra and dose responses studies, it is proposed that in these phosphors large defect complexes are formed, which include intrin...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci680

    authors: Luo DL,Tang Q,Zhang CX

    更新日期:2006-01-01 00:00:00

  • Optically stimulated luminescent glass optical fibre dosemeter.

    abstract::An optical fibre radiation dosemeter has been developed that utilises optically stimulated luminescence and scintillation to provide independent, remote, real-time dose measurements. The radiation sensitive element consists of a 1 mm long, 0.4 mm diameter piece of copper-ion-doped fused quartz that is attached to a 1 ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005974

    authors: Huston AL,Justus BL,Falkenstein PL,Miller RW,Ning H,Altemus R

    更新日期:2002-01-01 00:00:00

  • Radiation doses potentially received on-board aeroplanes during recent solar particle events.

    abstract::Because the doses received on-board aeroplanes are now monitored to fulfil legal requirements in some countries, including the European Community, the models to calculate doses received during solar events have left their purely academic status to become a part of operational systems as well. The present work consider...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci356

    authors: Lantos P

    更新日期:2006-01-01 00:00:00

  • Single-aliquot EPR dosimetry of wallboard (drywall).

    abstract::Electron paramagnetic resonance spectra and dose-response curves are presented for a variety of wallboard samples obtained from different manufacturing facilities, as well as for source gypsum and anhydrite. The intensity of the CO(3)(-) paramagnetic centre (G2) is enhanced with gamma radiation. Isothermal decay curve...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq581

    authors: Mistry R,Thompson JW,Boreham DR,Rink WJ

    更新日期:2011-11-01 00:00:00

  • Albedo Neutron Dosimetry in a Deep Geological Disposal Repository for High-Level Nuclear Waste.

    abstract::Albedo neutron dosemeter is the German official personal neutron dosemeter in mixed radiation fields where neutrons contribute to personal dose. In deep geological repositories for high-level nuclear waste, where neutrons can dominate the radiation field, it is of interest to investigate the performance of albedo neut...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw147

    authors: Pang B,Becker F

    更新日期:2017-04-28 00:00:00