Accreditation in radiation protection for cardiologists and interventionalists.

Abstract:

:Training in radiation protection is widely recognised as one of the basic components of optimisation programmes for medical exposures. Occupational and patient radiation risks in interventional radiology can be quite high and international bodies have shown concern on this item. Following recommendations of the International Commission on Radiological Protection and in accordance with the European Directive on medical exposures, some initiatives for training in radiation protection took place in Spain and Luxembourg. These provided practitioners of interventional radiology adequate theoretical and practical training in radiation protection. The main outcome of the pilot courses organised to this end is discussed, concluding its suitability to implement the European Directive in practice.

journal_name

Radiat Prot Dosimetry

authors

Vano E,Gonzalez L

doi

10.1093/rpd/nci730

keywords:

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

69-73

issue

1-3

eissn

0144-8420

issn

1742-3406

pii

nci730

journal_volume

117

pub_type

杂志文章
  • Assessment of natural radioactivity and the associated hazards in Iranian cement.

    abstract::This paper presents the finding of a study undertaken to determine natural radioactivity and associated hazards in local types of cement in Iran. A total of 42 samples were collected from various manufacturers and suppliers and analysed using a shielded HPGe gamma-ray spectrometer. The specific activities of 232Th, 22...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl549

    authors: Fathivand AA,Amidi J

    更新日期:2007-01-01 00:00:00

  • The Mayak Worker Dosimetry System (MWDS-2013): Estimate of Pu Content in Lungs and Thoracic Lymph Nodes From a Limited Set of Organ Autopsy Samples.

    abstract::A method to estimate plutonium content from a limited number of samples of lungs and pulmonary lymph nodes obtained at autopsies of former Mayak Production Association (MPA) workers is described. Historically from one to five samples of lung lobes and one to three respiratory lymph nodes (bronchopulmonary, tracheobron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw218

    authors: Sokolova AB,Suslova KG,Miller SC

    更新日期:2017-11-01 00:00:00

  • A micro-gap, air-filled ionisation chamber as a detector for criticality accident dosimetry.

    abstract::A micro-gap air-filled ionisation chamber was designed for criticality dosimetry. The special feature of the chamber is its very small gap between electrodes of only 0.3 mm. This prevents ion recombination at high dose rates and minimises the influence of gas on secondary particles spectrum. The electrodes are made of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct323

    authors: Murawski Ł,Zielczyński M,Golnik N,Gryziński MA

    更新日期:2014-10-01 00:00:00

  • A theoretical study on accurate measurements of thoron with airflow-through scintillation cell method.

    abstract::For accurate measurements of (220)Rn concentration with airflow-through scintillation cell method, a theoretical study was performed for discussing the influences of sampling flow rate, volumes of sampling tube and scintillation cell on the measurements. It is found that a high flow rate and a large inner volume of sc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq252

    authors: Tang F,Zhuo W,Zhao C,Chen B,Xu Y,He L

    更新日期:2010-10-01 00:00:00

  • MEASUREMENTS OF SPATIAL CORRELATIONS OF IONISATION CLUSTERS IN THE TRACK OF CARBON IONS-FIRST RESULTS.

    abstract::An attempt towards an experimental set up which could provide the experimental data on correlation processes occurred simultaneously in two distanced DNA targets within a charged particle track is presented. A modified Jet Counter nanodosemeter was used in two experiments with carbon ions with mean energies of 52 and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy079

    authors: Pietrzak M,Pszona S,Bantsar A

    更新日期:2018-08-01 00:00:00

  • IMPROVEMENT OF GAMMA-RAY SUBTRACTION PROCEDURE FOR A CURRENT-MODE NEUTRON DETECTOR WITH A PAIR OF 6Li- AND 7Li-GLASS SCINTILLATORS.

    abstract::A current-mode neutron detector with a pair of 6Li- and 7Li-glass scintillators has been developed to measure high-flux neutrons in a boron neutron capture therapy field. Neutrons are basically measured by subtracting gamma-ray component using current outputs from the 7Li-glass scintillator. In the present study, the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz266

    authors: Matsumoto T,Masuda A,Harano H,Hori JI,Sano T

    更新日期:2020-06-12 00:00:00

  • Hp(3)/Φ conversion coefficients for neutrons: discussion on the basis of the new ICRP recommended limit for the eye lens.

    abstract::The new recommendation issued by the International Commission on Radiological Protection (ICRP) introducing a 20-mSv annual dose limit for the eye lens stimulated an interesting debate among the radiation protection community. In the present work the problem of estimating Hp(3) for neutron realistic workplace spectra ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct246

    authors: Ferrari P,Gualdrini G,Tanner R,Fantuzzi E

    更新日期:2014-10-01 00:00:00

  • PUBLIC HEALTH ENGLAND-CENTRE FOR RADIATION, CHEMICAL AND ENVIRONMENTAL HAZARDS (PHE-CRCE) EXTERNAL EXPERT EXPERIENCE IN THE JOINT EXTERNAL EVALUATION (JEE) MISSION FOR THE RADIATION EMERGENCIES TECHNICAL AREA.

    abstract::From August 2016 to June 2017, the Public Health England-Centre for Radiation Chemical and Environmental Hazards (PHE-CRCE), collaborating centre of the WHO, through its Radiation Hazards and Emergencies Department Emergency Response Group has successfully supported five WHO Joint External Evaluation (JEE) missions in...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy142

    authors: de Ruvo A,Cox D

    更新日期:2018-12-01 00:00:00

  • Plutonium in the Ozyorsk population.

    abstract::Results of the long-term autopsy studies on plutonium body burden in the population of Ozyorsk situated in the vicinity of the radiochemical plant of the Mayak Production Association (Russia) have been presented. The data were obtained from radiochemical analysis of the soft tissue and bone samples collected at the au...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm303

    authors: Suslova KG,Khokhryakov VF,Sokolova AB

    更新日期:2007-01-01 00:00:00

  • Dose distribution in the Russian Segment of the International Space Station.

    abstract::Absorbed dose and average linear energy transfer (LET) were assessed by means of (7)LiF:Mg,Ti (TLD-700) thermoluminescent (TL) detectors for different panels on-board the Russian Segment of the International Space Station in the timeframe between March and November 2002 (233 d). A technique is presented to correct the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci566

    authors: Hajek M,Berger T,Fugger M,Fürstner M,Vana N,Akatov Y,Shurshakov V,Arkhangelsky V

    更新日期:2006-01-01 00:00:00

  • Discrimination between natural and other gamma ray sources from environmental gamma ray dose rate monitoring data.

    abstract::In this study, a method to discriminate between natural and other γ-ray sources from environmental γ-ray dose rate monitoring data was developed, and it was successfully applied to actual monitoring data around nuclear facilities. The environmental dose rate is generally monitored by NaI(Tl) detector systems in the lo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv265

    authors: Kumagai K,Ookubo H,Kimura H

    更新日期:2015-11-01 00:00:00

  • EVALUATION OF SECONDARY DOSE AND CANCER RISK FOR OUT-OF-FIELD ORGAN IN ESOPHAGEAL CANCER IMRT IN A CHINESE HOSPITAL USING ATOM PHANTOM MEASUREMENTS.

    abstract::There have been few studies on the secondary cancer after radiation treatment in Chinese hospitals. This study has measured out-of-field absorbed organ doses from intensity-modulated radiation therapy (IMRT) radiotherapy for esophageal cancer in a Chinese hospital and evaluated the risks of secondary cancer. The dose ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx057

    authors: Qi Y,He L,Wang Z,Liu Y,Liu H,Huo W,Xu XG,Chen Z

    更新日期:2017-12-01 00:00:00

  • Electron spin resonance evaluation of pure CaSO4 and as a phosphor doped with P and Dy.

    abstract::Polycrystalline CaSO4 powder, doped with different elements but mainly rare earths, is one of the most interesting thermoluminescent (TL) materials. Although many electron spin resonance (ESR) analyses have been reported for these materials few studies have been published about the potential of CaSO4 for ESR dosimetry...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006047

    authors: de Jesus EF,Rossi AM,Lopes RT

    更新日期:2002-01-01 00:00:00

  • CHARACTERIZATION OF 27 MEV PROTON BEAM GENERATED BY TOP-IMPLART LINEAR ACCELERATOR.

    abstract::The first proton linear accelerator for tumor therapy based on an actively scanned beam up to the energy of 150 MeV, is under development and construction by ENEA-Frascati, ISS and IFO, under the Italian TOP-IMPLART project. Protons up to the energy of 7 MeV are generated by a customized commercial injector operating ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy001

    authors: De Angelis C,Ampollini A,Basile E,Cisbani E,Della Monaca S,Ghio F,Montereali RM,Picardi L,Piccinini M,Placido C,Ronsivalle C,Soriani A,Strigari L,Trinca E,Vadrucci M

    更新日期:2018-08-01 00:00:00

  • Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter.

    abstract::In the present paper, we report the indigenous development of a neutron-sensitive thermoluminescent dosemeter (TLD) based on CaSO4:Dy Teflon TL disc. The study includes indigenous development of a neutron dosemeter and its response in terms of operational quantity to different energies of neutrons under various irradi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp019

    authors: Bakshi AK,Pradhan AS,Kher RK,Srivastava K,Varadharajan G,Chatterjee S,Sathian V

    更新日期:2009-01-01 00:00:00

  • Comparison of various anthropomorphic phantom types for in vivo measurements by means of Monte Carlo simulations.

    abstract::Three widely used anthropomorphic phantoms are analysed with regard to their suitability for the efficiency calibration of whole-body counters (WBCs): a Bottle Manikin Absorber (BOMAB) phantom consisting of water-filled plastic containers, a St Petersburg block phantom (Research Institute of Sea Transport Hygiene, St ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq320

    authors: Schläger M

    更新日期:2011-03-01 00:00:00

  • Sub-slab depressurisation systems used in the Czech Republic and verification of their efficiency.

    abstract::Design principles for sub-slab depressurisation systems recently used in the Czech Republic for remediating existing buildings are described. Results of an efficiency analysis performed on the basis of data from >60 single-family houses are presented. It was found out that the efficiency varies between 70 and 98 %, wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu219

    authors: Jiránek M

    更新日期:2014-11-01 00:00:00

  • Evaluation of occupational exposure to naturally occurring radioactive materials in the Iranian ceramics industry.

    abstract::Zircon contains small amounts of uranium, thorium and radium in its crystalline structure. The ceramic industry is one of the major consumers of zirconium compounds that are used as an ingredient at ∼10-20 % by weight in glaze. In this study, seven different ceramic factories have been investigated regarding the prese...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq441

    authors: Fathabadi N,Farahani MV,Amani S,Moradi M,Haddadi B

    更新日期:2011-06-01 00:00:00

  • The effect of Mg, Cu and P impurities on dose response of LiF:Mg,Cu,P phosphors: simulation versus experiments.

    abstract::In this research, the effect of magnesium (Mg), copper (Cu) and phosphorus (P) impurities on dosimetry response of LiF:Mg,Cu,P phosphors is studied experimentally and by the simulation procedure. In the experimental procedure, LiF:Mg,Cu,P phosphors in the powder form were synthesised by chemical co-precipitation metho...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv002

    authors: Mohammadi K,Khayat O,Afarideh H

    更新日期:2016-01-01 00:00:00

  • Application of a Ge semi-conductor detector to whole-body counter.

    abstract::To calibrate a whole-body counter, it is necessary to find a determination method for peak efficiencies of detectors used in the whole-body counter. For this purpose, peak efficiencies of a Ge semiconductor detector for point and volume sources were evaluated in the photon energy range 60-1836 keV by Monte Carlo simul...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006283

    authors: Kinase S,Noguchi H,Nakamura T

    更新日期:2003-01-01 00:00:00

  • Optically stimulated luminescent glass optical fibre dosemeter.

    abstract::An optical fibre radiation dosemeter has been developed that utilises optically stimulated luminescence and scintillation to provide independent, remote, real-time dose measurements. The radiation sensitive element consists of a 1 mm long, 0.4 mm diameter piece of copper-ion-doped fused quartz that is attached to a 1 ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005974

    authors: Huston AL,Justus BL,Falkenstein PL,Miller RW,Ning H,Altemus R

    更新日期:2002-01-01 00:00:00

  • Assessing The Risk Associated with Simultaneous Exposure To Mobile Communication Signals Within 900-2500 MHz in Nigeria.

    abstract::In this study, the total exposure due to signals within GSM 900, GSM 1800, CDMA-1900 and 3G-2100 frequency bands at 200 m from the foot of 120, 100 and 80 base station masts in the Nigerian cities of Lagos, Ibadan and Abuja, respectively, was assessed. A calibrated hand-held spectrum analyser was used to measure the l...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa203

    authors: Ayinmode BO,Farai IP

    更新日期:2020-12-31 00:00:00

  • Seasonal variation of indoor radon-222 levels in dwellings in Ramallah province and East Jerusalem suburbs, Palestine.

    abstract::This study presents the seasonal variations of indoor radon levels in dwellings located in the Ramallah province and East Jerusalem suburbs, Palestine. The measurements were performed during the summer and winter of the year 2006/2007 using CR-39 solid-state-nuclear-track detectors. The total number of investigated bu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr013

    authors: Leghrouz AA,Abu-Samreh MM,Shehadeh AK

    更新日期:2012-01-01 00:00:00

  • Keeping up with the neighbours--measuring the bystander response.

    abstract::Ionising radiation can induce responses within non-exposed neighbouring (bystander) cells, which potentially have important implications on the estimates of risk at environmentally relevant doses. Using human skin fibroblasts (AG1522), a range of methods were used to investigate the nature of the signal(s) arising fro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl430

    authors: Pyke EL,Stevens DL,Hill MA

    更新日期:2006-01-01 00:00:00

  • Radiation-induced micronucleus frequencies in female peripheral blood lymphocytes collected during the first and second half of the menstrual cycle.

    abstract::Biological dosimetry relies on the assessment of dose in peripheral blood lymphocytes (PBL) of a victim. Variability in the individual radiosensitivity of PBL has an impact on the precision of dose estimate and radiation-induced micronuclei show a strong individual variability. A factor which can influence the radiose...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl545

    authors: Krol M,Lankoff A,Buraczewska I,Derezinska E,Wojcik A

    更新日期:2007-01-01 00:00:00

  • Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation.

    abstract::In paediatrics, the risks associated with ionising radiation should be a major concern, due to children's higher susceptibility to radiation effects. Measure entrance skin dose (ESD) in chest and pelvis X-ray projections and compare the results with the 'European guidelines on quality criteria for diagnostic radiograp...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr355

    authors: Paulo G,Santos J,Moreira A,Figueiredo F

    更新日期:2011-09-01 00:00:00

  • UNATTACHED 212PB FRACTION IN THE WORKER'S BREATHING ZONE AT HIGH THORON CONCENTRATIONS.

    abstract::Classical aerosol physics predicts that it is impossible to observe noticeable values of the unattached fraction of decay products of thoron at typical concentrations of aerosol particles. The experimental data have shown that the unattached fraction of the thoron decay products in a monazite storage facility is in th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa154

    authors: Zhukovsky M,Vasyanovich M,Onishchenko A

    更新日期:2020-11-27 00:00:00

  • KINETIC SIMULATIONS OF THE THERMOLUMINESCENCE CHARACTERISTICS OF LiF:Mg, Ti INCORPORATING LOCALISED AND DELOCALISED RECOMBINATION.

    abstract::Kinetic simulations of the thermoluminescence characteristics of LiF:Mg, Ti are reviewed in the framework of conduction band/valence band models. Delocalised recombination models have been mainly applied to the simulation of glow peak shapes, although comparison with experimental data has proven difficult if not impos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa209

    authors: Eliyahu I,Oster L

    更新日期:2021-01-13 00:00:00

  • DOSIMETRIC PROPERTIES OF THE NEW TLD ALBEDO NEUTRON DOSEMETER AWST-TL-GD 04.

    abstract::A new official albedo dosemeter based on thermoluminescent detectors has been introduced in 2015 by the individual monitoring service of the Helmholtz Zentrum München for monitoring persons who are exposed occupationally against photon and neutron radiation. To enhance the sensitivity for fast neutrons, a new badge wi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv406

    authors: Haninger T,Henniger J

    更新日期:2016-09-01 00:00:00

  • Dose assessment from activated sodium within a body in criticality accidents.

    abstract::Some data were derived using recent sophisticated methods to rapidly convert specific activity of induced 24Na to average dose over a whole body in criticality accidents. Monte Carlo calculations using the MCNP-4B code were performed to study energy spectra of neutrons and gamma rays for some criticality systems with ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006350

    authors: Takahashi F,Endo A,Yamaguchi Y

    更新日期:2003-01-01 00:00:00