Methods of dark signal determination for CCD array spectroradiometers used in solar UVR measurements.

Abstract:

:The methods of the dark signal determination by direct contemporaneous measurements using a light spectrum and modelling of the dark signal based on the dark signal characterisation data were discussed. These techniques were tested with two charge-couple detectors (CCD) array spectroradiometers used in solar UVR measurements. The sensitivity of both instruments was significantly reduced when shutters were used; the measured signal varied by up to 12% depending on the orientation of the shutter. The shutters should be permanently attached to the SSR, so that the orientation cannot be changed to prevent an increase in uncertainty. The method of using blind pixels from the optically inactive part of the CCD array in a light spectrum could be used to derive the dark signal with some limitations for integration times <10 s for the QE65000. An alternative method of deriving the dark signal from light measurements using out-of-range pixels has been proved impossible due to out-of-range stray light in both instruments. The dark signal was characterised for the range of integration times and ambient temperatures of 15-35°C. Based on these data, the model of the dark signal was developed so that a single value of the dark signal can be subtracted over the whole spectral range if the instrument temperature is known.

journal_name

Radiat Prot Dosimetry

authors

Baczynska KA,Khazova M

doi

10.1093/rpd/ncu191

subject

Has Abstract

pub_date

2015-02-01 00:00:00

pages

387-93

issue

3

eissn

0144-8420

issn

1742-3406

pii

ncu191

journal_volume

163

pub_type

杂志文章
  • Achievements in workplace neutron dosimetry in the last decade: lessons learned from the EVIDOS project.

    abstract::The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm095

    authors: Tanner RJ,Bolognese-Milsztajn T,Boschung M,Coeck M,Curzio G,d'Errico F,Fiechtner A,Lillhök JE,Lacoste V,Lindborg L,Luszik-Bhadra M,Reginatto M,Schuhmacher H,Vanhavere F

    更新日期:2007-01-01 00:00:00

  • ORGANIC SCINTILLATOR FOR REAL-TIME NEUTRON DOSIMETRY.

    abstract::We developed a radiation detector based on an organic scintillator for spectrometry and dosimetry of out-of-field secondary neutrons from clinical proton beams. The detector consists of an EJ-299-34 crystalline organic scintillator, coupled by fiber optic cable to a silicon photomultiplier (SiPM). Proof of concept mea...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx255

    authors: Beyer KA,Di Fulvio A,Stolarczyk L,Parol W,Mojzeszek N,Kopéc R,Clarke SD,Pozzi SA

    更新日期:2018-08-01 00:00:00

  • Radiation exposure received by the medical radiation workers in Lithuania at the Institute of Oncology, Vilnius University, 2004-2011.

    abstract::The occupational radiation exposure of medical radiation workers at the Institute of Oncology, Vilnius University (IOVU) was analysed. Quartile dose measurements were collected and routinely analysed for a period of 8 y from 1 January 2004 to 31 December 2011. A total of 193 medical radiation workers were monitored, c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct111

    authors: Samerdokiene V,Atkocius V,Ofomala R

    更新日期:2013-11-01 00:00:00

  • Occupational exposure in angiography (Prague workplaces).

    abstract::The results of measurements, which were performed at angiography departments, are presented. The aim of this work was not only to assess patient exposure but also to perform a survey of the occupational exposures of physicians during common angiography examinations of the skull, chest, abdomen and limbs. Patient data,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006456

    authors: Zakova M

    更新日期:2001-01-01 00:00:00

  • MODELLING THE INDOOR RADIATION DOSES: A REVIEW AND PERSPECTIVE.

    abstract::Theoretical models to calculate the indoor gamma and radon doses are reviewed, refined and applied. The model for gamma doses is built based on the relative effects of the different room elements that control the amount of radiation. The relative doses are calculated by the MCNP5 simulation software. The gamma sources...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncz008

    authors: Orabi M

    更新日期:2019-12-31 00:00:00

  • OFF-SITE RADIOLOGICAL DOSE ASSESSMENT IN A SEVERE NUCLEAR ACCIDENT OF APR1400.

    abstract::Shin Kori unit 3 of Korea Hydro and Nuclear Power Co. is the pressurized water reactor of advanced power reactor 1400 (APR1400) in the Republic of Korea. A hypothetical accident was assumed for Shin Kori unit 3 to perform the time-dependent dose calculations along with the release rates of radionuclides to the environ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa105

    authors: Uddin GMB,Kim J

    更新日期:2020-09-16 00:00:00

  • Medical management of radiation accidents: capabilities and deployment principles of the Bundeswehr Institute of Radiobiology.

    abstract::Radiation accidents are fortunately infrequent occurrences, but since their consequences can be very serious as in the Chernobyl and the Fukushima nuclear accidents, medical management of radiation accidents is of great importance. Besides several other tasks, medical management of radiation accidents is one of the ke...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs159

    authors: Dörr H,Meineke V

    更新日期:2012-10-01 00:00:00

  • Uncertainty evaluation of radon measurements with LR115 detector and spark counter.

    abstract::To evaluate the uncertainties for nuclear track detectors used in radon measurements, a full understanding is required of the physical phenomena involved and the behaviour of the instruments utilised in the measuring process. As it concerns the LR115 nuclear track detector, an overall evaluation of uncertainty was giv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch361

    authors: Campi F,Caresana M,Ferrarini M,Garlati L,Palermo M,Rusconi R

    更新日期:2004-01-01 00:00:00

  • Dose tracking and radiology department management.

    abstract::The purpose of this work was to review the reasonable measures that should be implemented as part of a routine practice in the process of managing CT radiation risks in a typical average radiology department. Based on 6 y of experience in the management of a general radiology department and the newly implemented suppo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv038

    authors: Kirova G,Georgiev E,Zasheva C,St Georges A

    更新日期:2015-07-01 00:00:00

  • Dose effect for South Serbians due to 238U in natural drinking water.

    abstract::The use of depleted uranium ammunition in South Serbia during the 1999 Kosovo conflict raised a great deal of public concern in the Balkans. Radioactivity levels of 238U in 20 wells and lake water samples were checked from the viewpoint of internal radiation exposure for South Serbian subjects. We have measured 238U c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm294

    authors: Sahoo SK,Matsumoto M,Shiraishi K,Fujimoto K,Cuknic O,Zunic ZS

    更新日期:2007-01-01 00:00:00

  • Variability of radiocaesium inventory in Fukushima soil cores from one site measured at different times.

    abstract::The Fukushima Daiichi Nuclear Power Plant (FDNPP) accident has resulted in the deposition of radioactive contamination of soils mainly by (134)Cs and (137)Cs. The contaminated areas are of a great concern since external radiation may lead to significant long-term doses to humans and animals. External dose rate above g...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv276

    authors: Mishra S,Sahoo SK,Arae H,Sorimachi A,Hosoda M,Tokonami S,Ishikawa T

    更新日期:2015-11-01 00:00:00

  • Canadian national internal dosimetry performance testing programme: results of the pilot programme.

    abstract::This paper describes the design and construction of a new performance testing programme that was implemented in Canada in 2008. The Canadian Regulator (Canadian Nuclear Safety Commission) had determined that their licensees, in addition to participating in the existing in vivo and in vitro performance tests, needed to...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp088

    authors: Kramer GH

    更新日期:2009-06-01 00:00:00

  • COMMITTED EFFECTIVE DOSE DUE TO THE INTAKE OF 40K, 226Ra, 228Ra AND 228Th CONTAINED IN FOODS INCLUDED IN THE DIET OF THE RIO DE JANEIRO CITY POPULATION, BRAZIL.

    abstract::Annual effective dose due to the consumption of 40K, 226Ra, 228Ra and 228Th was estimated from high-resolution gamma spectrometry, food consumption data for the inhabitants of Rio de Janeiro City and dose coefficients published by the ICRP 119. A total of 31 samples of cereals, grains, vegetables, flours, liquid and p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx310

    authors: Lopes JM,Garcêz RWD,Filgueiras RA,Silva AX,Braz D

    更新日期:2018-10-01 00:00:00

  • THE CONVERSION OF EXPOSURES DUE TO RADON INTO THE EFFECTIVE DOSE TAKING INTO ACCOUNT THE EQUIVALENCE OF RISKS FROM SHORT- AND LONG-TERM EXPOSURES.

    abstract::The theoretical basis for comparing risks from short- and long-term exposures is developed aiming at implementing long-term exposures into a unique and consistent system of radiation protection. Based on system-analytical considerations, the equivalence of population-averaged risk rates due to prolonged exposures and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv553

    authors: Beck TR

    更新日期:2016-12-01 00:00:00

  • Assessment of occupational exposure to uranium by indirect methods needs information on natural background variations.

    abstract::Urine monitoring is the preferred method to determine exposure to soluble compounds of uranium in workplaces. The interpretation of uranium contents in workers bioassay samples requires knowledge on uranium excretion and its dependence on intake by diet. Exceptionally high concentrations of natural uranium in private ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm155

    authors: Muikku M,Heikkinen T,Puhakainen M,Rahola T,Salonen L

    更新日期:2007-01-01 00:00:00

  • Radiation doses in cerebral perfusion computed tomography: patient and phantom study.

    abstract::The purpose of this study was to investigate radiation doses in cerebral perfusion computed tomography (CT) examination. As a part of routine patient monitoring, data were collected on patients in terms of the skin dose and CT dose index (CTDIvol) and dose-length product (DLP) values. For the estimation of the dose to...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs260

    authors: Arandjic D,Bonutti F,Biasizzo E,Ciraj-Bjelac O,Floreani M,Giustizieri M,Iaiza F,Inkoom S,Tommasini G,Padovani R

    更新日期:2013-05-01 00:00:00

  • A METHOD TO IMPROVE DOSE ASSESSMENT BY RECONSTRUCTION OF THE COMPLETE ISOTOPES INVENTORY.

    abstract::Radiation shielding assessments may underestimate the expected dose if some isotopes at trace level are not considered in the isotopes inventory of the shielded radioactive materials. Indeed, information about traces is not often available. Nevertheless, the activation of some minor isotopic traces may significantly c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw266

    authors: Bonin A,Tsilanizara A

    更新日期:2017-06-01 00:00:00

  • Validation of a Monte Carlo efficiency calibration procedure for a partial body counter system with a voxel model of the LLNL torso phantom.

    abstract::Virtual models of real phantoms used with Monte Carlo methods facilitate the calibration and other studies associated with whole-body and partial-body counting systems. In this investigation, a voxel model of an LLNL torso phantom, available physically in the in vivo laboratory at KIT, was created from computed tomogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp030

    authors: Hegenbart L,Marzocchi O,Breustedt B,Urban M

    更新日期:2009-02-01 00:00:00

  • PUBLIC HEALTH ENGLAND-CENTRE FOR RADIATION, CHEMICAL AND ENVIRONMENTAL HAZARDS (PHE-CRCE) EXTERNAL EXPERT EXPERIENCE IN THE JOINT EXTERNAL EVALUATION (JEE) MISSION FOR THE RADIATION EMERGENCIES TECHNICAL AREA.

    abstract::From August 2016 to June 2017, the Public Health England-Centre for Radiation Chemical and Environmental Hazards (PHE-CRCE), collaborating centre of the WHO, through its Radiation Hazards and Emergencies Department Emergency Response Group has successfully supported five WHO Joint External Evaluation (JEE) missions in...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy142

    authors: de Ruvo A,Cox D

    更新日期:2018-12-01 00:00:00

  • AMANDE: a new facility for monoenergetic neutron fields production between 2 keV and 20 MeV.

    abstract::The variation of the response of the instruments with the neutron energy has to be determined in well-characterized monoenergetic neutron fields. The AMANDE facility will deliver such neutron fields between 2 keV and 20 MeV in an experimental hall designed with metallic walls for neutron scattering minimisation. The n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch185

    authors: Gressier V,Guerre-Chaley JF,Lacoste V,Lebreton L,Pelcot G,Pochat JL,Bolognese-Milstajn T,Champion D

    更新日期:2004-01-01 00:00:00

  • Nodule detection in digital chest radiography: effect of anatomical noise.

    abstract::The image background resulting from imaged anatomy can be divided into those components that are meaningful to the observers, in the sense that they are recognised as separate structures, and those that are not. These latter components (reffered to as anatomical noise) can be removed using a method developed within th...

    journal_title:Radiation protection dosimetry

    pub_type: 临床试验,杂志文章

    doi:10.1093/rpd/nch526

    authors: Båth M,Håkansson M,Börjesson S,Hoeschen C,Tischenko O,Kheddache S,Vikgren J,Månsson LG

    更新日期:2005-01-01 00:00:00

  • LiF:Mg,Cu,P glow curve shape dependence on heating rate.

    abstract::The glow curve shape of LiF:Mg,Cu,P (MCP) material is studied in this research. The study is focused on the effects of the heating rate on the dosimetric peaks. Different configurations of dosemeters (chips, cards and powder) are studied. The shifting of the dominant dosimetric peak is observed and analysed. The curve...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci529

    authors: Luo LZ,Velbeck KJ,Moscovitch M,Rotunda JE

    更新日期:2006-01-01 00:00:00

  • Shielding design of a brachytherapy unit at the Korle Bu teaching hospital in Ghana: comparison of theoretical calculations and experimental study.

    abstract::A theoretical study was carried out to re-evaluate the integrity of the biological shielding of (137)Cs brachytherapy unit at the Korle Bu Teaching Hospital, Ghana, and the results were verified by measurement of the dose rates at selected locations. The primary objective was to determine the current state of protecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq001

    authors: Arwui CC,Schandorf C,Nani K,Darko EO,Deatanyah P

    更新日期:2010-06-01 00:00:00

  • Neutron response of the chlorobenzene-ethanol-trimethylpentane dosimetry system.

    abstract::The dosimetric use of the chemical solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator thymolsulphonphthalein. On the basis of the CET solution, an accident and emergency personal dosemeter was designed allowing doses in the r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm042

    authors: Miljanić S,Razem D

    更新日期:2007-01-01 00:00:00

  • Shielding design calculations for beam dump facility of KOMAC.

    abstract::A project to construct the Korea Multi-purpose Accelerator Complex (KOMAC) is currently underway targeting a high-intensity proton beam with an average current of 4.8 mA. As for the first stage of construction, a 20 MeV linac is planned to be built by 2007 and additional DTL sections will be added to increase the prot...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci066

    authors: Cho YS,Lee YO,Chang J

    更新日期:2005-01-01 00:00:00

  • A co-ordinated network for radiation dosimetry (CONRAD): an overview.

    abstract::The European Radiation Dosimetry Group (EURADOS) carried out a co-ordinated action, supported within the 6th Framework Programme of the European Commission entitled 'A Co-ordinated Network for Radiation Dosimetry (CONRAD)'. The project, executed from January 2005 to March 2008, yielded a large number of scientific res...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn209

    authors: Schuhmacher H,Fantuzzi E

    更新日期:2008-01-01 00:00:00

  • Radiation exposure to the population of Europe following the Chernobyl accident.

    abstract::On the occasion of the 20th anniversary of the Chernobyl accident an attempt has been made to evaluate the impact of the Chernobyl accident on the global burden of human cancer in Europe. This required the estimation of radiation doses in each of the 40 European countries. Dose estimation was based on the analysis and...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl528

    authors: Drozdovitch V,Bouville A,Chobanova N,Filistovic V,Ilus T,Kovacic M,Malátová I,Moser M,Nedveckaite T,Völkle H,Cardis E

    更新日期:2007-01-01 00:00:00

  • Quality assurance (QA) procedures for software: evaluation of an ADC quality system.

    abstract::Image viewing and processing software in computed radiography manipulates image contrast in such a way that all relevant image features are rendered to an appropriate degree of visibility, and improves image quality using enhancement algorithms. The purpose of this study was to investigate procedures for the quality a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci742

    authors: Efstathopoulos EP,Benekos O,Molfetas M,Charou E,Kottou S,Argentos S,Kelekis NL

    更新日期:2005-01-01 00:00:00

  • Shortening the culture time in cytogenetic dosimetry using PCC-R assay.

    abstract::The fast assessment of the dose received by exposed persons is crucial in radiological accidents, so the 48 h of cell culture in conventional cytogenetic dosimetry in addition to some limitations after high doses becomes a disadvantage. The premature chromosome condensation (PCC) assay permits to analyse enough cells ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu258

    authors: Romero I,Lamadrid AI,González JE,García O,Voisin P,Roy L

    更新日期:2015-03-01 00:00:00

  • Methodology for Simple Spot Measurement of Equilibrium Equivalent Radon Concentration.

    abstract::Estimation of the effective inhalation dose of short half-life radon progeny requires the quantification of radon equilibrium equivalent activity concentrations (EEC, Ceq). The aim of the present study is to develop new methodology that focuses on spot measurements to determine EEC from single gross alpha counts and d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa176

    authors: Sakoda A,Ishimori Y,Kanzaki N,Tanaka H

    更新日期:2020-11-13 00:00:00