Protection from radon exposure at home and at work in the directive 2013/59/Euratom.

Abstract:

:In recent years, international organisations involved in radiation protection and public health have produced new guidance, recommendations and requirements aiming better protection from radon exposure. These organisations have often worked in close collaboration in order to facilitate the establishment of harmonised standards. This paper deals with such standards and specifically with the new European Council Directive of 5 December 2013 on basic safety standards for protection against the dangers arising from exposure to ionising radiation (2013/59/Euratom). This new Directive has established a harmonised framework for the protection against ionising radiations, including protection from radon exposure. Requirements for radon in workplace are much more tightening than in previous Directive, and exposures to radon in dwellings are regulated for the first time in a Directive. Radon-related articles of this Directive are presented and discussed in this paper, along with some comparisons with other relevant international standards.

journal_name

Radiat Prot Dosimetry

authors

Bochicchio F

doi

10.1093/rpd/ncu101

subject

Has Abstract

pub_date

2014-07-01 00:00:00

pages

8-13

issue

1-3

eissn

0144-8420

issn

1742-3406

pii

ncu101

journal_volume

160

pub_type

杂志文章
  • NATURAL RADIATION EXPOSURE TO THE PUBLIC IN MINING AND ORE BEARING REGIONS OF CAMEROON.

    abstract::Within the framework of a joint research project on natural radiation exposure and its health effects in Cameroon from 2014 to 2017, the Institute of Geological and Mining Research and the Hirosaki University worked together to carry out natural radiation survey in mining and ore bearing regions of Cameroon. Air kerma...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz176

    authors: Tokonami S,Hosoda M,Joseph Emmanuel NNI,Akata N,Flore TSY,Modibo OB,Samuel BG,Didier TSS

    更新日期:2019-10-01 00:00:00

  • Dosimetry of a set-up for the exposure of newborn mice to 2.45-GHZ WiFi frequencies.

    abstract::This work describes the dosimetry of a two waveguide cell system designed to expose newborn mice to electromagnetic fields associated with wireless fidelity signals in the frequency band of 2.45 GHz. The dosimetric characterisation of the exposure system was performed both numerically and experimentally. Specific meas...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq129

    authors: Pinto R,Lopresto V,Galloni P,Marino C,Mancini S,Lodato R,Pioli C,Lovisolo GA

    更新日期:2010-08-01 00:00:00

  • Neutron dose calculation at the maze entrance of medical linear accelerator rooms.

    abstract::Currently, teletherapy machines of cobalt and caesium are being replaced by linear accelerators. The maximum photon energy in these machines can vary from 4 to 25 MeV, and one of the great advantages of these equipments is that they do not have a radioactive source incorporated. High-energy (E > 10 MV) medical linear ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl144

    authors: Falcão RC,Facure A,Silva AX

    更新日期:2007-01-01 00:00:00

  • DNA fragments induction in human fibroblasts by radiations of different qualities.

    abstract::Experimental data on DNA double strand break (DSB) induction in human fibroblasts (AG1522), following irradiation with several radiation qualities, namely gamma rays, 0.84 MeV protons, 58.9 MeV u(-1) carbon ions, iron ions of 115 MeV u(-1), 414 MeV u(-1), 1 GeV u(-1), and 5 GeV u(-1), are presented. DSB yields were me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl389

    authors: Esposito G,Belli M,Campa A,Cherubini R,Cuttone G,Dini V,Furusawa Y,Gerardi S,Simone G,Sorrentino E,Tabocchini MA

    更新日期:2006-01-01 00:00:00

  • Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter.

    abstract::In the present paper, we report the indigenous development of a neutron-sensitive thermoluminescent dosemeter (TLD) based on CaSO4:Dy Teflon TL disc. The study includes indigenous development of a neutron dosemeter and its response in terms of operational quantity to different energies of neutrons under various irradi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp019

    authors: Bakshi AK,Pradhan AS,Kher RK,Srivastava K,Varadharajan G,Chatterjee S,Sathian V

    更新日期:2009-01-01 00:00:00

  • LESSONS LEARNED FROM THE EURADOS SURVEY ON INDIVIDUAL MONITORING DATA AND INTERNAL DOSE ASSESSMENTS OF FOREIGNERS EXPOSED IN JAPAN FOLLOWING THE FUKUSHIMA DAIICHI NPP ACCIDENT.

    abstract::European Radiation Dosimetry Group e.V. (EURADOS) survey on individual monitoring data and dose assessment has been carried out for 550 foreigners returning home after being exposed in Japan to intakes of radionuclides (mainly (131)I, (132)I, (132)Te, (134)Cs and (137)Cs) as a consequence of the Fukushima Daiichi NPP ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv510

    authors: Lopez MA,Fojtik P,Franck D,Osko J,Gerstmann U,Scholl C,Lebacq AL,Breustedt B,Del Risco Norrlid L

    更新日期:2016-09-01 00:00:00

  • Benchmarking of MCNP for calculating dose rates at an interim storage facility for nuclear waste.

    abstract::During the operation of research facilities at Research Centre Jülich, Germany, nuclear waste is stored in drums and other vessels in an interim storage building on-site, which has a concrete shielding at the side walls. Owing to the lack of a well-defined source, measured gamma spectra were unfolded to determine the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci185

    authors: Heuel-Fabianek B,Hille R

    更新日期:2005-01-01 00:00:00

  • In vivo thermoluminescence dosimetry for total body irradiation.

    abstract::An improvement in the clinical results obtained using total body irradiation (TBI) with photon beams requires precise TBI treatment planning, reproducible irradiation, precise in vivo dosimetry, accurate documentation and careful evaluation. In vivo dosimetry using LiF Harshaw TLD-100 chips was used during the TBI tre...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006058

    authors: Palkosková P,Hlavata H,Dvorák P,Novotný J,Novotný J Jr

    更新日期:2002-01-01 00:00:00

  • Thermoluminescence properties of KCl(1-X)KBrX:Pb2+ mixed crystals.

    abstract::A study is presented of the thermoluminescence (TL) of phosphors based on potassium halides doped with divalent lead, such as KCl:Pb2+, KBr:Pb2+ and the crystalline series KCl(1-X)Br(X):Pb2+. The defects in the crystals generated by irradiation have been investigated as well as the trapping and room temperature recomb...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005913

    authors: Cruz-Zaragoza E,Meléndrez R,Chernov V,Barboza-Flores M,Piters TM,Hernández JA,Murrieta HS

    更新日期:2002-01-01 00:00:00

  • Variations in radon concentration in groundwater of Kumaon Himalaya, India.

    abstract::The radon content in groundwater sources depends on the radium concentration in the rock of the aquifer. Radon was measured in water in many parts of the world, mostly for the risk assessment due to consumption of drinking water. The exposure to radon through drinking water is largely by inhalation and ingestion. Airb...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs186

    authors: Bourai AA,Gusain GS,Rautela BS,Joshi V,Prasad G,Ramola RC

    更新日期:2012-11-01 00:00:00

  • IMPORTANCE OF ENGAGING IN DIALOGUE WITH THE POPULATION AFTER A NUCLEAR ACCIDENT.

    abstract::Human behaviour is primarily driven by perceptions and this is particularly important in the aftermath of a nuclear accident. One of the main lessons we can draw from the Chernobyl and Fukushima accidents is that once the acute phase of the accident is over, it is important to engage in dialogue with the affected popu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw320

    authors: Vanmarcke H

    更新日期:2017-04-01 00:00:00

  • Soil gas radon measurements in a region of the Bohemian Massif: investigations in the framework of an Austrian pilot study.

    abstract::Soil gas radon measurements are carried out in a pilot study in three municipalities in Upper Austria. The selected municipalities are characterised by a high radon potential. Sixty measuring sites--well distributed over the region and over the different geological areas--were selected. Additionally, the permeability ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr089

    authors: Seidel C,Baumgartner A,Ringer W,Gräser J,Friedmann H,Kaineder H,Maringer FJ

    更新日期:2011-05-01 00:00:00

  • Measured proton sensitivities of bubble detectors.

    abstract::The neutron dose equivalent in aircraft is measured using commercial bubble detectors, but at high altitudes there are not only neutrons but also protons. Bubble detectors have been used because they are considered not to be sensitive to protons, but this has been the subject of only a few studies. In this study, by i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch330

    authors: Takada M,Kitamura H,Koi T,Nakamura T,Fujitaka K

    更新日期:2004-01-01 00:00:00

  • Biokinetics of radionuclides and treatment of accidental intakes.

    abstract::This paper describes the objectives and reviews the progress of EULEP Working Party 5, convened under the auspices of the European Union's Fifth Framework Programme, to 'cluster' two EU-supported contracts, Biokinetics and Dosimetry of Internal Contamination (BIODOS (EU Contract FIS5-1999-00214)) and Radionuclide Biok...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006318

    authors: Taylor DM,Stradling GN,Ménétrier F

    更新日期:2003-01-01 00:00:00

  • Stability of A-150 plastic ionisation chamber response over a approximately 30-y period.

    abstract::At the Northern Illinois University Institute for Neutron Therapy at Fermilab, the clinical tissue-equivalent ionisation chamber response is measured every treatment day using a cesium source that was configured to match readings obtained at the National Bureau of Standards. Daily measurements are performed in air usi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm126

    authors: Kroc TK,Lennox AJ

    更新日期:2007-01-01 00:00:00

  • CONCEPTS OF OPERATIONS FOR A US DOSIMETRY AND BIODOSIMETRY NETWORK.

    abstract::The USA must be prepared to provide a prompt, coordinated and integrated response for radiation dose and injury assessment for suspected radiation exposure, whether it involves isolated cases or mass casualties. Dose estimation for radiation accidents typically necessitates a multiple parameter diagnostics approach th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy294

    authors: Dainiak N,Albanese J,Kaushik M,Balajee AS,Romanyukha A,Sharp TJ,Blakely WF

    更新日期:2019-12-31 00:00:00

  • Feminist theoretical perspectives on ethics in radiology.

    abstract::The substantive safety of radiological and other medical procedures can be radically reduced by unconscious factors governing scientific thought. In addition, the historical exclusion of women from these disciplines has possibly skewed their development in directions that now need to be addressed. This paper focuses o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp055

    authors: Condren M

    更新日期:2009-07-01 00:00:00

  • INVESTIGATION OF THE INFLUENCE OF THE POSITION INSIDE A SMALL AIRCRAFT ON THE COSMIC-RADIATION-INDUCED DOSE.

    abstract::This article report the measurements on-board a small aircraft at the same altitude and around the same geographic coordinates. The measurements of Ambient Dose Equivalent Rate (H*(10)) were performed in several positions inside the aircraft, close and far from the pilot location and the discrimination between neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw384

    authors: Prado ACM,Pazianotto MT,Gonçalez OL,Dos Santos LR,Caldeira AD,Pereira HHC,Hubert G,Federico CA

    更新日期:2017-11-01 00:00:00

  • Radiation doses in cerebral perfusion computed tomography: patient and phantom study.

    abstract::The purpose of this study was to investigate radiation doses in cerebral perfusion computed tomography (CT) examination. As a part of routine patient monitoring, data were collected on patients in terms of the skin dose and CT dose index (CTDIvol) and dose-length product (DLP) values. For the estimation of the dose to...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs260

    authors: Arandjic D,Bonutti F,Biasizzo E,Ciraj-Bjelac O,Floreani M,Giustizieri M,Iaiza F,Inkoom S,Tommasini G,Padovani R

    更新日期:2013-05-01 00:00:00

  • Radiation protection at low energy proton accelerators.

    abstract::A sample is provided of the radiological safety issues particular to low energy proton accelerators. 'Low' energy in this context is taken to mean proton energies of less than about 1 GeV. Many of the radiation issues are common to all particle accelerators. Here, those issues are addressed that may require perhaps no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006619

    authors: Moritz LE

    更新日期:2001-01-01 00:00:00

  • Development of a new passive integral dosemeter for gamma ray monitoring using an imaging plate.

    abstract::A new passive integral dosemeter for gamma ray monitoring is being developed using an imaging plate (IP). In the application of IPs to dosimetry, a fading effect causes serious problems. The fading is considered to be caused by the recombination or holes and charges trapped shallowly in the F centres, which have sever...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006396

    authors: Ohuchi H,Yamadera A,Baba M

    更新日期:2003-01-01 00:00:00

  • Dose conversion of radon exposure according to new epidemiological findings.

    abstract::In 1993, ICRP-65 recommended that dose conversion of radon exposure should be based on the comparison of detriments between radon exposure and effective dose. The lifetime detriment from the radon exposure was projected according to the epidemiological studies of uranium miners then available. The projection model (GS...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn117

    authors: Tomasek L,Rogel A,Laurier D,Tirmarche M

    更新日期:2008-01-01 00:00:00

  • Radiation dose management in CT, SPECT/CT and PET/CT techniques.

    abstract::New imaging technologies utilising X rays and radiopharmaceuticals are continuously under development. The benefit of computed tomography (CT) has been so dramatic that there is a tendency to overuse it and not to place enough efforts into optimisation of the technique. It is also now more and more common to combine t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncr261

    authors: Mattsson S,Söderberg M

    更新日期:2011-09-01 00:00:00

  • Defect complexes in Re3+-doped magnesium sulphate phosphors.

    abstract::A series of magnesium sulphate phosphors MgSO4:RE3+,X ( RE = Dy, Tm, Eu and X = P, Mn) have been prepared and studied. Based on the experimental results of thermoluminescence (TL) emission spectra and dose responses studies, it is proposed that in these phosphors large defect complexes are formed, which include intrin...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci680

    authors: Luo DL,Tang Q,Zhang CX

    更新日期:2006-01-01 00:00:00

  • Suggested diagnostic reference levels for paediatric X-ray examinations in India.

    abstract::Exposure of children to ionising radiation is considered to carry higher risk than that of adults; therefore a need to suggest diagnostic reference levels (DRLs) for the common paediatric diagnostic X-ray procedures was recognised for the X-ray machines meeting the requirements of the recently implemented Safety Code ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq458

    authors: Sonawane AU,Sunil Kumar JV,Singh M,Pradhan AS

    更新日期:2011-11-01 00:00:00

  • Diagnostic reference levels in digital mammography: a systematic review.

    abstract::This study aims to review the literature on existing diagnostic reference levels (DRLs) in digital mammography and methodologies for establishing them. To this end, a systematic search through Medline, Cinahl, Web of Science, Scopus and Google scholar was conducted using search terms extracted from three terms: DRLs, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncu365

    authors: Suleiman ME,Brennan PC,McEntee MF

    更新日期:2015-12-01 00:00:00

  • Dosimetric feature of natural biotite mineral.

    abstract::A thermoluminescence (TL) study relevant to radiation dosimetry has been carried out for X-ray irradiated biotite mineral under un-annealed and different annealed (473, 573, 673 and 773 K) conditions. Some significant variations in dosimetric characteristics have been observed with annealing treatment. Due to generati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu289

    authors: Kalita JM,Wary G

    更新日期:2015-04-01 00:00:00

  • Simultaneous measurements of indoor radon, radon-thoron progeny and high-resolution gamma spectrometry in Greek dwellings.

    abstract::Simultaneous indoor radon, radon-thoron progeny and high-resolution in situ gamma spectrometry measurements, with portable high-purity Ge detector were performed in 26 dwellings of Thessaloniki, the second largest town of Greece, during March 2003-January 2005. The radon gas was measured with an AlphaGUARD ionisation ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci366

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2006-01-01 00:00:00

  • Investigation of mean glandular dose versus compressed breast thickness relationship for mammography.

    abstract::The relationship between the mean glandular dose (MGD) and the compressed breast thickness (CBT) is commonly used for the presentation of mammographic dose survey results and could also be useful for the assessment of individual breast doses retrospectively in case of lack of necessary dosimetric instrumentation. The ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn140

    authors: Bor D,Tukel S,Olgar T,Toklu T,Aydin E,Akyol O

    更新日期:2008-01-01 00:00:00

  • Measurement of natural radioactivity in building materials used in Urumqi, China.

    abstract::Building materials contain natural radionuclides (226)Ra, (232)Th and (40)K, which cause direct radiation exposure of the public. The concentrations of (226)Ra, (232)Th and (40)K in commonly used building materials of Urumqi, China have been analysed using gamma-ray spectrometry. The concentrations of (226)Ra, (40)K a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct002

    authors: Ding X,Lu X,Zhao C,Yang G,Li N

    更新日期:2013-07-01 00:00:00