Exposure caused by wireless technologies used for short-range indoor communication in homes and offices.

Abstract:

:In order to estimate typical radio frequency exposures from indoor used wireless communication technologies applied in homes and offices, WLAN, Bluetooth and Digital Enhanced Cordless Telecommunications systems, as well as baby surveillance devices and wireless headphones for indoor usage, have been investigated by measurements and numerical computations. Based on optimised measurement methods, field distributions and resulting exposure were assessed on selected products and real exposure scenarios. Additionally, generic scenarios have been investigated on the basis of numerical computations. The obtained results demonstrate that under usual conditions the resulting spatially (over body dimensions) averaged and 6-min time-averaged exposure for persons in the radio frequency fields of the considered applications is below approximately 0.1% of the reference level for power density according to the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines published in 1998. Spatial and temporal peak values can be considerably higher by 2-3 orders of magnitude. In case of some transmitting devices operated in close proximity to the body (e.g. WLAN transmitters), local exposure can reach the same order of magnitude as the basic restriction; however, none of the devices considered in this study exceeded the limits according to the ICNIRP guidelines.

journal_name

Radiat Prot Dosimetry

authors

Schmid G,Lager D,Preiner P,Uberbacher R,Cecil S

doi

10.1093/rpd/ncm245

subject

Has Abstract

pub_date

2007-01-01 00:00:00

pages

58-62

issue

1

eissn

0144-8420

issn

1742-3406

pii

ncm245

journal_volume

124

pub_type

杂志文章
  • The influence of novel CT reconstruction technique and ECG-gated technique on image quality and patient dose of cardiac computed tomography.

    abstract::The aim of the present study was to compare image quality and patient dose in cardiac computed tomography angiography (CTA) in terms of volume computed tomography dose index (CTDI vol), dose length product (DLP) and effective dose, when changing from filtered back projection (FBP) to adaptive iterative dose reduction ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv114

    authors: Dyakov I,Stoinova V,Groudeva V,Vassileva J

    更新日期:2015-07-01 00:00:00

  • A MULTI-ELEMENT THICK GAS ELECTRON MULTIPLIER-BASED MICRODOSEMETER FOR MEASUREMENT OF NEUTRONS DOSE-EQUIVALENT: A MONTE CARLO STUDY.

    abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx024

    authors: Moslehi A,Raisali G

    更新日期:2017-11-01 00:00:00

  • Comparative analysis between radiation doses obtained by EPR dosimetry using tooth enamel and established analytical methods for the population of radioactively contaminated territories.

    abstract::A comparative analysis of radiation doses determined by tooth enamel electron paramagnetic resonance (EPR) spectroscopy and by an acknowledged analytical method is performed for individual doses and for average doses in population of some settlements of the Bryansk region (Russia), which have been contaminated after t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu132

    authors: Ivannikov AI,Skvortsov VG,Stepanenko VF,Zhumadilov KSh

    更新日期:2014-06-01 00:00:00

  • ISFSI site boundary radiation dose rate analyses.

    abstract::Across the globe nuclear utilities are in the process of designing and analysing Independent Spent Fuel Storage Installations (ISFSI) for the purpose of above ground spent-fuel storage primarily to mitigate the filling of spent-fuel pools. Using a conjoining of discrete ordinates transport theory (DORT) and Monte Carl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci279

    authors: Hagler RJ,Fero AH

    更新日期:2005-01-01 00:00:00

  • ESTIMATION OF ORGAN DOSES AMONG DIAGNOSTIC MEDICAL RADIATION WORKERS IN SOUTH KOREA.

    abstract::This study aimed to estimate the radiation organ doses from occupational exposure in 94 396 Korean medical radiation workers. Data on badge doses (i.e. personal dose equivalent at 10 mm) between 1996 and 2011 obtained from a national dosimetry registry, survey data from 2012 to 2013, and organ dose conversion coeffici...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx239

    authors: Choi Y,Shil Cha E,Jin Bang Y,Ko S,Ha M,Lee C,Jin Lee W

    更新日期:2018-04-01 00:00:00

  • SIMULATION OF OSL AND TLD DOSEMETER RESPONSE FOR THE DEVELOPMENT OF NEW EXTREMITY DOSEMETERS.

    abstract::The individual monitoring service at the Helmholtz Zentrum München is currently developing a new eye lens dosemeter to be integrated in radiation protection glasses and a new ring dosemeter using a new BeOSL detector element for extremity dosimetry developed by Dosimetrics. In the design process for the new eye lens d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy299

    authors: Hoedlmoser H,Brönner J,Bandalo V,Wahl F,Greiter MB

    更新日期:2019-12-23 00:00:00

  • Mechanistic modelling of radiation-induced bystander effects.

    abstract::A model of radiation-induced bystander effects is presented that explicitly takes into account the transient nature of bystander signal emission post-irradiation, signal lifetime and the non-linear cellular response to the signals. Data are analysed on mutagenesis induced in human lymphoblasts in medium transfer exper...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv170

    authors: Kundrát P,Friedland W

    更新日期:2015-09-01 00:00:00

  • Liulin-type spectrometry-dosimetry instruments.

    abstract::The main purpose of Liulin-type spectrometry-dosimetry instruments (LSDIs) is cosmic radiation monitoring at the workplaces. An LSDI functionally is a low mass, low power consumption or battery-operated dosemeter. LSDIs were calibrated in a wide range of radiation fields, including radiation sources, proton and heavy-...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq506

    authors: Dachev Ts,Dimitrov P,Tomov B,Matviichuk Y,Spurny F,Ploc O,Brabcova K,Jadrnickova I

    更新日期:2011-03-01 00:00:00

  • Full spectrum analysis in environmental monitoring.

    abstract::In environmental radiation monitoring, the time-variable natural gamma radiation background complicates the nuclide identification and analysis of a gamma spectrum. A full spectrum analysis based on the noise adjusted singular value decomposition method for the description of the time-variable background and adjustmen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu144

    authors: Reinhardt S

    更新日期:2014-08-01 00:00:00

  • Skin dose measurements using radiochromic films, TLDS and ionisation chamber and comparison with Monte Carlo simulation.

    abstract::Estimation of the surface dose is very important for patients undergoing radiation therapy. The purpose of this study is to investigate the dose at the surface of a water phantom at a depth of 0.007 cm as recommended by the International Commission on Radiological Protection and International Commission on Radiation U...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct315

    authors: Alashrah S,Kandaiya S,Maalej N,El-Taher A

    更新日期:2014-12-01 00:00:00

  • Shielding Effect of Lead Glasses on Radiologists' Eye Lens Exposure in Interventional Procedures.

    abstract::To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw098

    authors: Hu P,Kong Y,Chen B,Liu Q,Zhuo W,Liu H

    更新日期:2017-04-20 00:00:00

  • Plutonium isotopes in marine sediments and some biota from the Sudanese coast of the Red Sea.

    abstract::Measurements of (239+240)Pu and (238)Pu were carried out on marine biota as well as on sediments from the fringing reefs area extending towards north and south (Flamingo Bay) of PortSudan harbour. The analyses were performed using radiochemical separation and alpha spectrometry. The range of the activity concentration...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn193

    authors: Sirelkhatim DA,Sam AK,Hassona RK

    更新日期:2008-01-01 00:00:00

  • Study of the transfer of 137Cs from fodder to cow milk in the region around Narora Atomic Power Station NPP Site, India.

    abstract::Site-specific transfer coefficient from feed to cow's milk, for (137)Cs in the villages around Narora, a nuclear power station site in India, determined over a period of 17 y, is presented in this paper. In the transport model for the prediction of the concentration of (137)Cs in milk, the transfer coefficient from fe...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct058

    authors: Kumar D,Kumar A,Sharma AK,Singh B,Ravi PM,Sarkar PK

    更新日期:2013-09-01 00:00:00

  • Influence of the uniformity of the slab phantom illumination on the calibration of personal dosemeters.

    abstract::For the calibration of personal dosemeters in terms of H(p)(10), the ISO water slab phantom shall be used. The irradiation geometry must be chosen such that the field diameter at the phantom front surface is large enough to irradiate the phantom completely and, in addition, homogeneously. However, in practice it is no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq036

    authors: Ankerhold U,Ambrosi P

    更新日期:2010-06-01 00:00:00

  • Validation of efficiency tracing and zero detection threshold techniques using liquid scintillation analyser TriCarb.

    abstract::Efficiency tracing with unquenched 14C and zero detection threshold with unquenched 3H as tracers are practical and simple techniques which have been implemented to quantify the activity of various beta emitters using liquid scintillation analyser. These techniques are used to study the influence of quench level on ac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq495

    authors: Reddy PJ,Bhade SP,Babu DA,Sharma DN

    更新日期:2011-11-01 00:00:00

  • Physical image quality comparison of four types of digital detector for chest radiology.

    abstract::Image quality for similar exposure conditions has been compared for two computed radiography (CR) systems (needle-based and conventional storage phosphor) and two flat-panel (DR) systems from different manufacturers mainly devoted to chest radiology. Image quality was assessed with a contrast-detail object and acrylic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn026

    authors: Fernandez JM,Ordiales JM,Guibelalde E,Prieto C,Vano E

    更新日期:2008-01-01 00:00:00

  • DYNAMIC RESPONSE OF CCD ARRAY SPECTRORADIOMETERS.

    abstract::A number of factors affect the measurements by charge coupled (CCD) array spectroradiometers, including stray light, dynamic response and ambient temperature. The departure from linearity was assessed for four CCD array spectroradiometers and linearity correction calculated with standard uncertainties error estimates....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv396

    authors: Baczynska KA,Price LL,Khazova M

    更新日期:2016-11-01 00:00:00

  • Bremsstrahlung and photoneutron production in a steel shield for 15-22-MeV clinical electron beams.

    abstract::The physical data regarding bremsstrahlung and neutrons produced in a steel shield by high-energy electron beams from a medical linear accelerator were investigated. These data are required to allow the accurate prediction of shielding performance for high-energy electron beams and in the design of radiotherapy facili...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu153

    authors: Fujita Y,Myojoyama A,Saitoh H

    更新日期:2015-02-01 00:00:00

  • Albedo Neutron Dosimetry in a Deep Geological Disposal Repository for High-Level Nuclear Waste.

    abstract::Albedo neutron dosemeter is the German official personal neutron dosemeter in mixed radiation fields where neutrons contribute to personal dose. In deep geological repositories for high-level nuclear waste, where neutrons can dominate the radiation field, it is of interest to investigate the performance of albedo neut...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw147

    authors: Pang B,Becker F

    更新日期:2017-04-28 00:00:00

  • Shielding design calculations for beam dump facility of KOMAC.

    abstract::A project to construct the Korea Multi-purpose Accelerator Complex (KOMAC) is currently underway targeting a high-intensity proton beam with an average current of 4.8 mA. As for the first stage of construction, a 20 MeV linac is planned to be built by 2007 and additional DTL sections will be added to increase the prot...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci066

    authors: Cho YS,Lee YO,Chang J

    更新日期:2005-01-01 00:00:00

  • Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologists.

    abstract::In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu315

    authors: Farah J,Struelens L,Auvinen A,Jacob S,Koukorava C,Schnelzer M,Vanhavere F,Clairand I

    更新日期:2015-04-01 00:00:00

  • Determination of radon concentration levels in well water in Konya, Turkey.

    abstract::Radon ((222)Rn) measurements were undertaken in 16 samples of well water representing different depths and different types of aquifers found at the city centre of Konya, Central Turkey. The radon activity concentrations of the well water samples collected in the spring and summer seasons of 2012 were measured by using...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct099

    authors: Erdogan M,Eren N,Demirel S,Zedef V

    更新日期:2013-10-01 00:00:00

  • CALCULATION OF CONVERSION COEFFICIENTS FOR VOXELIZED PHANTOMS FOR CRITICALITY ACCIDENT DOSIMETRY.

    abstract::In the event of a criticality accident, not only the maximal doses received by the victims must be determined but it is also crucial to evaluate the doses to the different organs. With a neutron component, morphology is a key parameter in the organ dose calculation. As the simulation tools can be time consuming to pro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa123

    authors: Chevallier MA,Pontier JB,Morin H,Duluc M,Evo S,Letang E,Trompier F

    更新日期:2020-11-06 00:00:00

  • MODELLING THE INDOOR RADIATION DOSES: A REVIEW AND PERSPECTIVE.

    abstract::Theoretical models to calculate the indoor gamma and radon doses are reviewed, refined and applied. The model for gamma doses is built based on the relative effects of the different room elements that control the amount of radiation. The relative doses are calculated by the MCNP5 simulation software. The gamma sources...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncz008

    authors: Orabi M

    更新日期:2019-12-31 00:00:00

  • Different versions of the right answer: the importance of measurement uncertainty in radiation dosimetry.

    abstract::The performance of radiation dosemeters that are issued by approved individual monitoring services generally meet international standards, with typical results within a few tens of per cent of the reference value. Experienced dosimetry practitioners will understand the uncertainties and treat monitoring results with d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq298

    authors: Gilvin P,McWhan A

    更新日期:2011-03-01 00:00:00

  • New diagnostic reference level for full-field digital mammography units.

    abstract::The diagnostic reference level (DRL) has generally been defined as the 75th percentile of the distributions of mean doses observed on a sample of standard-sized patients, but for mammography, the 95th percentile has been used. In this study, the 75th and 95th percentiles are estimated for 26 full-field digital mammogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct136

    authors: Hauge IH,Bredholt K,Olerud HM

    更新日期:2013-12-01 00:00:00

  • Comparison of different methods for shielding design in computed tomography.

    abstract::The purpose of this work is to compare different methods for shielding calculation in computed tomography (CT). The BIR-IPEM (British Institute of Radiology and Institute of Physics in Engineering in Medicine) and NCRP (National Council on Radiation Protection) method were used for shielding thickness calculation. Sca...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr287

    authors: Ciraj-Bjelac O,Arandjic D,Kosutic D

    更新日期:2011-09-01 00:00:00

  • Personal dose equivalent conversion coefficients for electrons to 1 Ge V.

    abstract::In a previous paper, conversion coefficients for the personal dose equivalent, H(p)(d), for photons were reported. This note reports values for electrons calculated using similar techniques. The personal dose equivalent is the quantity used to approximate the protection quantity effective dose when performing personal...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr252

    authors: Veinot KG,Hertel NE

    更新日期:2012-04-01 00:00:00

  • Analysis and improvement of cyclotron thallium target room shield.

    abstract::Because of high neutron and gamma-ray intensities generated during bombardment of a thallium-203 target, a thallium target-room shield and different ways of improving it have been investigated. Leakage of neutron and gamma ray dose rates at various points behind the shield are calculated by simulating the transport of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn099

    authors: Hajiloo N,Raisali G,Aslani G

    更新日期:2008-01-01 00:00:00

  • The impact of automatic wedge filter on photoneutron and photon spectra of an 18-MV photon beam.

    abstract::The effect of an automatic wedge filter on photon and photoneutron spectra of a medical linac was evaluated using the Monte Carlo method. The head of an Elekta SL75/25 was simulated using the MCNPX Monte Carlo code. The photon and photoneutron spectra for open and wedged beams were calculated at the isocentre with a s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp204

    authors: Ghavami SM,Mesbahi A,Mohammadi E

    更新日期:2010-02-01 00:00:00