Calculation of the store house worker dose in a lost wax foundry using MCNP-4C.

Abstract:

:Lost wax casting is an industrial process which permits the transmutation into metal of models made in wax. The wax model is covered with a silicaceous shell of the required thickness and once this shell is built the set is heated and wax melted. Liquid metal is then cast into the shell replacing the wax. When the metal is cool, the shell is broken away in order to recover the metallic piece. In this process zircon sands are used for the preparation of the silicaceous shell. These sands have varying concentrations of natural radionuclides: 238U, 232Th and 235U together with their progenics. The zircon sand is distributed in bags of 50 kg, and 30 bags are on a pallet, weighing 1,500 kg. The pallets with the bags have dimensions 80 cm x 120 cm x 80 cm, and constitute the radiation source in this case. The only pathway of exposure to workers in the store house is external radiation. In this case there is no dust because the bags are closed and covered by plastic, the store house has a good ventilation rate and so radon accumulation is not possible. The workers do not touch with their hands the bags and consequently skin contamination will not take place. In this study all situations of external irradiation to the workers have been considered; transportation of the pallets from vehicle to store house, lifting the pallets to the shelf, resting of the stock on the shelf, getting down the pallets, and carrying the pallets to production area. Using MCNP-4C exposure situations have been simulated, considering that the source has a homogeneous composition, the minimum stock in the store house is constituted by 7 pallets, and the several distances between pallets and workers when they are at work. The photons flux obtained by MCNP-4C is multiplied by the conversion factor of Flux to Kerma for air by conversion factor to Effective Dose by Kerma unit, and by the number of emitted photons. Those conversion factors are obtained of ICRP 74 table 1 and table 17 respectively. This is the way to obtain a function giving dose rate around the source.

journal_name

Radiat Prot Dosimetry

authors

Alegría N,Legarda F,Herranz M,Idoeta R

doi

10.1093/rpd/nci156

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

73-6

issue

1-4 Pt 2

eissn

0144-8420

issn

1742-3406

journal_volume

116

pub_type

杂志文章
  • The newsletter 'European Research in Radiological Sciences'.

    abstract::The newsletter 'European Research in Radiological Sciences' is jointly published by the European Late Effects Project Group and the European Radiation Dosimetry Group to disseminate information about research projects and activities carried out under the EURATOM Framework Programme. Since May 2003, the Newsletter is o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch095

    authors: Pihet P,d'Errico F,Dörr W,Gruenberger M,Schofield P

    更新日期:2004-01-01 00:00:00

  • Development of a radon trap device using a corona discharge.

    abstract::Radon is one of the noble gases, which are chemically inert and do not make any reactants under normal conditions. In this experiment we demonstrated an enigmatic reaction between radon and fluorine when a corona discharge is used as a promoter. Distinctive changes in radon concentrations were caused by the discharge ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci311

    authors: Yamada Y,Koizumi A,Ishikawa K,Hishinuma Y,Tatenuma K

    更新日期:2005-01-01 00:00:00

  • Experimental simulation of A-bomb gamma ray spectra: revisited.

    abstract::It has been reported recently that the A-bomb gamma ray spectra received by the colon of the average Japanese survivor of Hiroshima and Nagasaki may be experimentally simulated using a hospital-based Philips SL15 linear accelerator. The simulated A-bomb gamma radiation may be used in radiobiology experiments to determ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch320

    authors: Pattison JE,Payne LC,Hugtenburg RP,Beddoe AH,Charles MW

    更新日期:2004-01-01 00:00:00

  • CAN HALF VALUE LAYER MEASUREMENTS BE USED TOGETHER WITH THE EFFECTIVE ENERGY TO OBTAIN CONVERSION COEFFICIENTS FOR X-RAY SPECTRA?

    abstract::Conversion coefficients are a substantial vehicle in practical radiation protection to determine the dose (rate) of a given radiation field. According to ICRU report 57, their values shall be obtained by means of spectrometry. This is, however, a time-consuming complicated procedure that cannot be performed by all dos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw003

    authors: Behnke B,Hupe O

    更新日期:2017-04-15 00:00:00

  • Calculation of conversion coefficients for clinical photon spectra using the MCNP code.

    abstract::In this work, the MCNP4B code has been employed to calculate conversion coefficients from air kerma to the ambient dose equivalent, H*(10)/Ka, for monoenergetic photon energies from 10 keV to 50 MeV, assuming the kerma approximation. Also estimated are the H*(10)/Ka for photon beams produced by linear accelerators, su...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch351

    authors: Lima MA,Silva AX,Crispim VR

    更新日期:2004-01-01 00:00:00

  • High survival of frozen cells irradiated with gamma radiation.

    abstract::Cell storage in liquid nitrogen (LN) offers the most secure method of cell preservation even if cryopreserved cells are exposed to natural background of ionising radiation (IR). A lot of experiments have demonstrated that IR can induce damages in living cells, but only a little information regarding the response of cr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq541

    authors: Cugia G,Centis F,Del Zotto G,Lucarini A,Argazzi E,Zini G,Valentini M,Bono M,Picardi F,Stramigioli S,Cesarini W,Zamai L

    更新日期:2011-02-01 00:00:00

  • In situ occupational and general public exposure to VHF/UHF transmission for air traffic communication.

    abstract::Occupational and general public exposure due to very high frequency (VHF)/ultra high frequency (UHF) transmission centres for verbal communication for air traffic control is investigated in situ for the first time. These systems are used for communication with aircraft, resulting in different human exposure from that ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs016

    authors: Joseph W,Goeminne F,Verloock L,Vermeeren G,Martens L

    更新日期:2012-09-01 00:00:00

  • PRACTICAL METHODS FOR INTERNAL DOSE ASSESSMENT FOR RADIOIODINE INTAKE AFTER THYROID BLOCKING: CLASSIFICATION OF DEGREE OF BLOCKAGE AND DETERMINATION OF INSENSITIVE MEASUREMENT POINT.

    abstract::Iodine thyroid blocking (ITB) suppresses the uptake of iodine to the thyroid and reduces internal doses after radioiodine intake; however, its disturbance of thyroid biokinetics causes considerable uncertainty in the use of dosimetric data intended for assessment of unblocked normal thyroid. To more accurately assess ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz139

    authors: Kwon TE,Park M,Jung GH,Chung Y,Ha WH,Jin YW

    更新日期:2019-12-31 00:00:00

  • An in vitro L-band electron paramagnetic resonance study of highly irradiated whole teeth.

    abstract::Regarding in vivo L-band dosimetry with human teeth, a number of preliminary experiments were carried out that were linked to the resonators response and the relative contribution of enamel to the EPR signal intensity of irradiated whole teeth. The sensitivity of the extended loop resonator varies in the antenna plane...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006036

    authors: Zdravkova M,Wieser A,El-Faramawy N,Gallez B,Debuyst R

    更新日期:2002-01-01 00:00:00

  • Biophysical analysis of radiation induced initial DNA fragmentation.

    abstract::Production of double strand breaks (DSBs) and double-stranded DNA fragments after irradiation with high energy nitrogen ions was simulated with stochastic track generation and a high-order chromatin structure (HOCS) model representing a segment of interphase chromosome. The non-random distribution of DNA fragments is ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006748

    authors: Khvostunov IK,Andreev SG,Eidelman Y

    更新日期:2002-01-01 00:00:00

  • Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters.

    abstract::Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolní Rozínka' at Rozná, Czech Republic. The sampling flow...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm455

    authors: Becková V,Malátová I

    更新日期:2008-01-01 00:00:00

  • Liulin-type spectrometry-dosimetry instruments.

    abstract::The main purpose of Liulin-type spectrometry-dosimetry instruments (LSDIs) is cosmic radiation monitoring at the workplaces. An LSDI functionally is a low mass, low power consumption or battery-operated dosemeter. LSDIs were calibrated in a wide range of radiation fields, including radiation sources, proton and heavy-...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq506

    authors: Dachev Ts,Dimitrov P,Tomov B,Matviichuk Y,Spurny F,Ploc O,Brabcova K,Jadrnickova I

    更新日期:2011-03-01 00:00:00

  • Extremity dosimetry trial: Devonport Royal Dockyard.

    abstract::This trial was undertaken to assess extremity dosemeters, which were made available to Devonport Royal Dockyard and determine the most suitable to the site. The trial included operational and laboratory-based exposures. Operational exposures were within a submarine reactor compartment and a waste storage area. Laborat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn052

    authors: Kenyon R,Collison R

    更新日期:2008-01-01 00:00:00

  • Assessment of effective dose in paediatric CT examinations.

    abstract::Current concerns focus on the high doses encountered in computed tomography (CT) examinations as they are extending towards younger and more radiosensitive patients. Previous work produced conversion coefficients for effective dose (E) from dose-length product (DLP) for four anatomical body regions applicable to any p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr288

    authors: Dougeni E,Chapple CL,Willis J,Panayiotakis G

    更新日期:2011-09-01 00:00:00

  • Evaluation of internal exposure of nuclear medicine staff through in vivo and in vitro bioassay techniques.

    abstract::The manipulation of a wide variety of unsealed sources in Nuclear Medicine results in a significant risk of internal exposure of the workers. 131I should be highlighted among the most frequently used radionuclides because of its large application for diagnosis and therapy of thyroid diseases. The increasing use of rad...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm365

    authors: Lucena EA,Rebelo AM,Araújo F,Sousa WO,Dantas AL,Dantas BM,Corbo R

    更新日期:2007-01-01 00:00:00

  • Dose performance evaluation of a charge coupled device and a flat-panel digital fluoroscopy system recently installed in an interventional cardiology laboratory.

    abstract::The purpose of the study was to evaluate the dose performance of a flat-panel (FP) and an image intensifier (II) charge coupled device (CCD) digital fluoroscopy X-ray systems newly installed in an Interventional Cardiology (IC) department. Filter entrance dose rate, detector dose rate (during fluoroscopy) and filter e...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch344

    authors: Tsapaki V,Kottou S,Kollaros N,Dafnomili P,Kyriakidis Z,Neofotistou V

    更新日期:2004-01-01 00:00:00

  • Current challenges of full field digital mammography.

    abstract::Full field digital mammography (FFDM) has advantages over screen-film mammography (SFM), but some important challenges remain. The first challenge is related to the specific characteristics of FFDM. It remains unclear, which shape and limiting values of the modulation transfer function have the most influence on the p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci729

    authors: Van Ongeval C,Bosmans H,Van Steen A

    更新日期:2005-01-01 00:00:00

  • Radiation exposure received by the medical radiation workers in Lithuania at the Institute of Oncology, Vilnius University, 2004-2011.

    abstract::The occupational radiation exposure of medical radiation workers at the Institute of Oncology, Vilnius University (IOVU) was analysed. Quartile dose measurements were collected and routinely analysed for a period of 8 y from 1 January 2004 to 31 December 2011. A total of 193 medical radiation workers were monitored, c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct111

    authors: Samerdokiene V,Atkocius V,Ofomala R

    更新日期:2013-11-01 00:00:00

  • A comparative review of charged particle microbeam facilities.

    abstract::At the low doses (and low dose rates) relevant to environmental and occupational radiation exposure (0-50 mSv), which are of practical concern for radiation protection, very few cells in the human organism experience more than one traversal by densely ionising particles in their lifetime, the intervals between the tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncl444

    authors: Gerardi S

    更新日期:2006-01-01 00:00:00

  • IMPROVEMENT OF GAMMA-RAY SUBTRACTION PROCEDURE FOR A CURRENT-MODE NEUTRON DETECTOR WITH A PAIR OF 6Li- AND 7Li-GLASS SCINTILLATORS.

    abstract::A current-mode neutron detector with a pair of 6Li- and 7Li-glass scintillators has been developed to measure high-flux neutrons in a boron neutron capture therapy field. Neutrons are basically measured by subtracting gamma-ray component using current outputs from the 7Li-glass scintillator. In the present study, the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz266

    authors: Matsumoto T,Masuda A,Harano H,Hori JI,Sano T

    更新日期:2020-06-12 00:00:00

  • The genetics of radiation-induced osteosarcoma.

    abstract::Individual genetic variation can influence susceptibility to the carcinogenic effects of many environmental carcinogens. In radiation-exposed populations those individuals with a greater genetically determined susceptibility would be at greater risk of developing cancer. To include this modification of risk into radia...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006778

    authors: Rosemann M,Kuosaite V,Nathrath M,Atkinson MJ

    更新日期:2002-01-01 00:00:00

  • Calculation and Validation of the Response Matrix for a Neutron Multisphere Spectrometer with an Indium Central Detector.

    abstract::Expansion of accelerator technologies into different application areas brings the need for neutron-field measurements in their vicinity. The measurements of neutron energy spectra and neutron dose rates can be done with the aid of neutron multisphere spectrometers with passive neutron detectors. In addition to the usu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx183

    authors: Vlk P,Pavlovic M

    更新日期:2018-04-01 00:00:00

  • Thermoluminescence properties of LiMgF3 doped with Ce, Er and Dy.

    abstract::The main dosimetric properties are reported of a new perovskite, LiMgF3, doped with Ce, Er and Dy impurities. An annealing temperature of 400 degrees C for one hour is necessary to erase any previous signal and to stabilise its sensitivity. A readout up to 450 degrees C gives the same result. The glow curve structure ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005858

    authors: Kitis G,Furetta C,Sanipoli C

    更新日期:2002-01-01 00:00:00

  • Terrestrial gamma radioactivity levels and their corresponding extent exposure of environmental samples from Wadi El Assuity protective area, Assuit, Upper Egypt.

    abstract::Representative environmental samples (sandy soil, limestone, marble and gravels) collected from Wadi El Assuity, protective area, Assuit governorate in Upper Egypt have been investigated radiometrically using NaI (Tl) gamma-ray spectrometer. The specific activity of the radionuclides in Bq kg⁻¹ for soil ranged between...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq425

    authors: El-Taher A

    更新日期:2011-06-01 00:00:00

  • RADIOECOLOGICAL IMPACT AND THE ASSOCIATED HAZARDS DUE TO NORM FROM OIL AND GAS PRODUCTION FACILITY IN THE WESTERN DESERT OF EGYPT.

    abstract::An oil and gas production facility in the western desert of Egypt was investigated for possible radiation risks due to the routine operation. Radium-226, Radium-228 and Potassium-40 were assessed in the soil samples collected from the adjacent soakaway pond. The average 226Ra, 228Ra and 40K activity concentrations wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa084

    authors: Ebaid YY,Hassan Y,Elshemey WM

    更新日期:2020-08-28 00:00:00

  • Effective dose calculations in conventional diagnostic X-ray examinations for adult and paediatric patients in a large Italian hospital.

    abstract::The effective dose E is an efficient and powerful parameter to study the radioprotection of the patient. In our hospital, eight radiological departments and more than 100 radiological X-ray tubes are present. The effective doses were calculated for adults and paediatric patients in 10 standard projections. To calculat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch508

    authors: Compagnone G,Pagan L,Bergamini C

    更新日期:2005-01-01 00:00:00

  • Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote afterloader.

    abstract::In support of the effort to begin high-dose rate 252Cf brachytherapy treatments at Tufts-New England Medical Center, the shielding capabilities of a clinical accelerator vault against the neutron and photon emissions from a 1.124 mg 252Cf source were examined. Outside the clinical accelerator vault, the fast neutron d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch473

    authors: Melhus CS,Rivard MJ,Kurkomelis J,Liddle CB,Massé FX

    更新日期:2005-01-01 00:00:00

  • A comparative study of dielectric response function models for liquid water.

    abstract::Various methodologies that aim at an analytic representation of the dielectric response function (DRF) of liquid water with emphasis on the Bethe ridge region are compared. The use of optical data is a common feature to all models presented providing an empirical ground for modelling the valence energy losses where ma...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl414

    authors: Emfietzoglou D,Nikjoo H,Pathak A

    更新日期:2006-01-01 00:00:00

  • Aircraft crew radiation workplaces: comparison of measured and calculated ambient dose equivalent rate data using the EURADOS in-flight radiation data base.

    abstract::In May 2000, the chairman of the European Radiation Dosimetry Group (EURADOS) invited a number of experts with experience of cosmic radiation dosimetry to form a working group (WG 5) on aircraft crew dosimetry. Three observers from the Article 31 Group of Experts as well as one observer from the Joint Aviation Authori...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl029

    authors: Beck P,Bartlett D,Lindborg L,McAulay I,Schnuer K,Schraube H,Spurny F

    更新日期:2006-01-01 00:00:00

  • ESTE-DECISION SUPPORT SYSTEM FOR NUCLEAR AND RADIOLOGICAL ACCIDENTS.

    abstract::Described are functions, models and approaches of software tool Emergency Source Term code (ESTE), which is decision support system for crisis staff in case of nuclear or radiological accidents. The first task of ESTE in emergency situation at nuclear facility is to evaluate state of reactor core or state of fuel in s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz226

    authors: Fojcíková E,Lipták Ľ,Krpelanová M,Chylý M,Čarný P

    更新日期:2019-12-31 00:00:00