Abstract:
:The US has far-reaching and extensive experience in the long-term management of areas contaminated with radioactive materials. This experience base includes the Department of Energy's continued follow-up with Hiroshima and Nagasaki from the 1940s at the Radiological Effects Research Foundation in Hiroshima, Japan, the long-term management of the Marshall Islands Programme, the clean-up of the US nuclear weapons complex and the ongoing management of accident sites such as in Palomares, Spain. This paper discusses the lessons learnt and best practices gained from this far-reaching and extensive experience in the long-term management of areas contaminated with radioactive materials.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Jones CRdoi
10.1093/rpd/nch255keywords:
subject
Has Abstractpub_date
2004-01-01 00:00:00pages
75-7issue
1-2eissn
0144-8420issn
1742-3406pii
109/1-2/75journal_volume
109pub_type
杂志文章,评审abstract::In the present paper, the long noses of Pinocchio, Tengu and Trolls are used to measure, respectively, radon, thoron, and their decay products both by track-etch detectors and by Geiger-Müller (G-M) counters. Just recently, four new passive samplers (termed quatrefoil) have been developed which greatly simplify the de...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq248
更新日期:2010-10-01 00:00:00
abstract::The 106 866 dwellings measured for radon in Finland so far by Radiation and Nuclear Safety Authority include 5560 apartments. The radon concentrations in ground-contact apartments are similar to those in low-rise residential buildings located in the same area. The values in apartments above the first floor do not sign...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs211
更新日期:2012-11-01 00:00:00
abstract::To estimate internal doses due to the inhalation of radionuclides produced by the nuclear spallation of the air nuclei in high-energy proton accelerator facilities, the physicochemical properties of radionuclides are very important. Thus, the ratio of aerosol and gases of 38Cl and 39Cl formed by irradiating argon gas-...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm475
更新日期:2007-01-01 00:00:00
abstract::In this study, the total exposure due to signals within GSM 900, GSM 1800, CDMA-1900 and 3G-2100 frequency bands at 200 m from the foot of 120, 100 and 80 base station masts in the Nigerian cities of Lagos, Ibadan and Abuja, respectively, was assessed. A calibrated hand-held spectrum analyser was used to measure the l...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa203
更新日期:2020-12-31 00:00:00
abstract::Thermoluminescene (TL) and mechanoluminescence (ML) properties of gamma-irradiated Dy activated potassium and magnesium mixed sulphate have been studied. (K2Mg2:Dy) (SO4)3 samples having different concentrations of Dy were prepared by solid-state diffusion method. Two distinct peaks, the first approximately 130 degree...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci607
更新日期:2006-01-01 00:00:00
abstract::In radiotherapy, radiochromic films can be used for verification of delivery of dose distributions calculated by treatment planning systems. The main objective of this work was to compare three different techniques for evaluation of dose distributions for prostate cancer treatment plans using radiochromic EBT3 films. ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz231
更新日期:2019-12-31 00:00:00
abstract::Dosimetric monitoring and protection of the personnel involved into interventional procedures is one of the key issues nowadays, yet doses received by their brains were left without rigorous consideration so far. The paper is the fast track of the results of the pilot study of possible magnitude of operator's doses wi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw091
更新日期:2016-09-01 00:00:00
abstract::In vitro dose-response calibration curves for (60)Co gamma rays have been established for unstable chromosome aberrations in human peripheral blood lymphocytes. The observed dose-response data were fitted to a linear quadratic model. The calibration curve parameters were used to estimate the equivalent whole-body dose...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl109
更新日期:2007-01-01 00:00:00
abstract::Dental cone beam computed tomography (CBCT), also known as digital volumetric tomography was developed in the late 1990s and is now increasingly available in clinical practice. It can provide high resolution cross-sectional images of teeth and the maxillofacial region with applications in all branches of dentistry. As...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncs289
更新日期:2013-02-01 00:00:00
abstract::The biokinetic and dosimetric model of the gastrointestinal (GI) tract applied in current documents of the International Commission on Radiological Protection (ICRP) was developed in the mid-1960s. The model was based on features of a reference adult male and was first used by the ICRP in Publication 30, Limits for In...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncl104
更新日期:2007-01-01 00:00:00
abstract::To study the effect of patient size, anatomical location and modulation strength (MS) on image-quality and delivered dose of CT scans acquired with automatic-exposure-control system (AEC). Four anthropomorphic phantoms (three paediatric and one thin adult) were studied, and normal and obese adults were simulated by pl...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx055
更新日期:2017-12-01 00:00:00
abstract::In 2011, a serious radiation accident occurred in Stamboliyski, Bulgaria, in an industrial sterilisation facility using very-high-activity (60)Co sources. For the five persons accidentally exposed, biological dosimetry based on dicentric analysis was performed in Sofia and in Paris, where the patients were transferred...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct032
更新日期:2013-08-01 00:00:00
abstract::Analytical geometric models for the bones of the knee region have been developed. A survey was done on real pieces to obtain the dimensions of the geometric sections used in each model. The dependence of the section dimensions on the bone length and the estimated dimensions of the bones for a 1.70 m tall person are pr...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm445
更新日期:2008-01-01 00:00:00
abstract::Environmental radiation monitoring in the vicinity of coal-fired power plants which are used primarily to determine the variability in measured background exposures are presented in this article; this is in order to estimate the contribution due to the plants' operation. Measurements have been done using a multi-eleme...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch401
更新日期:2004-01-01 00:00:00
abstract::The prevalent algorithm for the estimation of beta dose, which in turn is used for estimation of skin dose for exposures involving beta radiations was observed to significantly overestimate the dose in individual monitoring based on CaSO4:Dy TLD badge in India. A new algorithm has been developed by estimating the corr...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw273
更新日期:2017-06-01 00:00:00
abstract::One of the topics which forms part of CONRAD project addresses the problems related to the dosimetry of complex-mixed radiation fields at workplaces. This topic was included in work package (WP) 6. WP 6 was established to co-ordinate research activities in two areas:the development of new techniques and the improvemen...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn220
更新日期:2008-01-01 00:00:00
abstract::Ionising radiation exposure of cells might induce the perturbation of cell functions and, in particular, the activation or inhibition of several important pathways. This perturbation can cause the deregulation of both intra- and extra-cellular signalling cascades (such as the inflammatory pathway) and alter not only t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv132
更新日期:2015-09-01 00:00:00
abstract::International standards for radiation protection dosemeters are published by the International Electrotechnical Commission and the International Organization for Standardization. Several standards exist side by side, although they treat the same measuring task, and specify different requirements, so that dosemeters of...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncm331
更新日期:2008-01-01 00:00:00
abstract::A secondary standard ionisation chamber for photon radiation for measuring an ionisation current, which is directly proportional to the conventionally true value of the ambient dose equivalent, H*(10), was optimised. The chamber was developed in the Austrian Research Centers Seibersdorf and is used successfully worldw...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci334
更新日期:2006-01-01 00:00:00
abstract::A device based on a single silicon detector of special converter/detector design optimised for the determination of the neutron dose equivalent is also used for the determination of the photon dose equivalent. While the neutron dose is determined on the basis of signals corresponding to energy depositions above 1.5 Me...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005962
更新日期:2002-01-01 00:00:00
abstract::Natural radionuclide contents of 226Ra, 228Ra and (40)K were studied for inter-tidal sediments collected from selected locations off the745 km long Balochistan Coast using HPGe detector based gamma-spectrometry system. The sampling zone extends from the beaches of Sonmiani (near Karachi metropolis) through Jiwani (clo...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl105
更新日期:2007-01-01 00:00:00
abstract::A Monte Carlo based computational procedure for determining organ doses and effective doses has been described for two procedures used in newly developed image-guided radiation treatment: kilovoltage cone-beam computed tomography (kV CBCT) and mega-voltage computed tomography (MV CBCT). A whole-body patient computatio...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn200
更新日期:2008-01-01 00:00:00
abstract::The fast assessment of the dose received by exposed persons is crucial in radiological accidents, so the 48 h of cell culture in conventional cytogenetic dosimetry in addition to some limitations after high doses becomes a disadvantage. The premature chromosome condensation (PCC) assay permits to analyse enough cells ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu258
更新日期:2015-03-01 00:00:00
abstract::The experimental energy dependence of the electron paramagnetic resonance (EPR) radiation-induced signal at irradiation by photons in the energy range of 13 keV-1.25 MeV was analysed in terms of the absorbed dose in human tooth enamel. The latter was calculated using a Monte Carlo simulation of the photon and electron...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch040
更新日期:2004-01-01 00:00:00
abstract::In response to reactive oxygen species (ROS) or electrophiles, the transcription factor nuclear factor-erythroid 2 (NF-E2)-related factor 2 (Nrf2) rapidly translocates into the nucleus and induces the expression of various antioxidant genes, such as heme oxygenase-1 (HO-1). Low linear energy transfer (LET) ionising ra...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs201
更新日期:2012-11-01 00:00:00
abstract::The localisation of an unknown neutron source in various bulky homogeneous media was studied. For the planar case two (3)He detectors on the opposite faces of a box were used. It is shown that the location of a single small neutron emitting source in a large box can be found to a better than 7% by using two neutron de...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm048
更新日期:2007-01-01 00:00:00
abstract::This study assesses the level of natural radioactivity due to radionuclides, ²³⁸U, ²³²Th and ⁴⁰K, in 50 soil samples collected from South Konkan, Maharashtra, India. The mean activity concentrations of ²³⁸U, ²³²Th and ⁴⁰K are 44.97 ± 1.22 Bq kg⁻¹, 59.70 ± 2.17 Bq kg⁻¹ and 217.51 ± 8.75 Bq kg⁻¹, respectively, measured ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct131
更新日期:2013-12-01 00:00:00
abstract::At least 10% of inhabitants in the Czech Republic are supplied with water from private sources (private wells, boreholes). With the increasing cost of water, the number of people using their own sources of drinking water will be likely to increase. According to the Decree of the State Office for Nuclear Safety about t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu095
更新日期:2014-07-01 00:00:00
abstract::Our debaters have agreed to defend positions that appear to be diametrically opposed; nevertheless, they have acknowledged some common ground. Although it was not explicitly stated, they would no doubt agree that workers and the public are adequately protected by our present system of radiation regulations. Our debate...
journal_title:Radiation protection dosimetry
pub_type: 评论,杂志文章
doi:
更新日期:2003-01-01 00:00:00
abstract::This study aims to provide more insight in attenuation characteristics and corresponding lead (Pb) equivalences of a broad range of commercially available lead composite and nonlead protective garments. Thirty garments of five manufacturers (listed as 0.25-0.35-0.50 mm Pb equivalent) were tested. Transmission values w...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw373
更新日期:2017-08-01 00:00:00