Levels of depleted uranium in Kosovo soils.

Abstract:

:The United Nations Environment Programme (UNEP) has performed a field survey at 11 sites located in Kosovo, where depleted uranium (DU) ammunitions were used by the North Atlantic Treaty Organization (NATO) during the last Balkans conflict (1999). Soil sampling was performed to assess the spread of DU ground contamination around and within the NATO target sites and the migration of DU along the soil profile. The 234U/238U and 235U/238U activity concentration ratios have been used as an indicator of natural against anthropogenic sources of uranium. The results show that levels of 238U activity concentrations in soils above 100 Bq x kg(-1) can be considered a 'tracer' of the presence of DU in soils. The results also indicate that detectable ground surface contamination by DU is limited to areas within a few metres from localised points of concentrated contamination caused by penetrator impacts. Vertical distribution of DU along the soil profile is measurable up to a depth of 10-20 cm. This latter aspect is of particular relevance for the potential risk of future contamination of groundwater.

journal_name

Radiat Prot Dosimetry

authors

Sansone U,Stellato L,Jia G,Rosamilia S,Gaudino S,Barbizzi S,Belli M

doi

10.1093/oxfordjournals.rpd.a006679

keywords:

subject

Has Abstract

pub_date

2001-01-01 00:00:00

pages

317-20

issue

4

eissn

0144-8420

issn

1742-3406

journal_volume

97

pub_type

杂志文章
  • A pilot study of the dependence of radon concentration on the tectonic structures, using simple geophysical methods.

    abstract::It is well known that there are great variations in radon concentrations in the soil gas on building sites. The concentration may sometimes vary by more than two orders of magnitude. The tectonic structure of the bedrock is one of the factors that influence the intensity of the radon outflow. The simple ARES geophysic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr070

    authors: Thinova L,Fronka A,Rovenska K

    更新日期:2011-05-01 00:00:00

  • Methodology for Simple Spot Measurement of Equilibrium Equivalent Radon Concentration.

    abstract::Estimation of the effective inhalation dose of short half-life radon progeny requires the quantification of radon equilibrium equivalent activity concentrations (EEC, Ceq). The aim of the present study is to develop new methodology that focuses on spot measurements to determine EEC from single gross alpha counts and d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa176

    authors: Sakoda A,Ishimori Y,Kanzaki N,Tanaka H

    更新日期:2020-11-13 00:00:00

  • EXPERIMENTAL EVALUATION OF NEUTRON SHIELDING MATERIALS.

    abstract::A new proposed design of neutron shielding material-based on the commercial material Borotron UH050 with an addition of Al(OH)3-is evaluated in order to determine if its neutron and gamma shielding properties match those of a reference material, NS4FR. Neutron and gamma dosimetry measurements are performed, as well as...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx202

    authors: Campo X,Méndez R,Lacerda MAS,Garrido D,Embid M,Sanz J

    更新日期:2018-08-01 00:00:00

  • A Monte-Carlo code for the detailed simulation of electron and light-ion tracks in condensed matter.

    abstract::In an effort to understand the basic mechanism of the action of charged particles in solid radiation dosimeters, we extend our Monte-Carlo code (MC4) to condensed media (liquids/solids) and present new track-structure calculations for electrons and protons. Modeling the energy dissipation process is based on a model d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci671

    authors: Emfietzoglou D,Papamichael G,Karava K,Androulidakis I,Pathak A,Phillips GW,Moscovitch M,Kostarelos K

    更新日期:2006-01-01 00:00:00

  • Optimised geometry to calculate dose rate conversion coefficient for external exposure to photons.

    abstract::A single-parameter geometry to describe soil is achieved for Monte Carlo calculation of absorbed dose rate in air for photon emitters from natural radionuclides. This optimised geometry based on physical assumptions consists of the soil part whose emitted radiation has a given minimum probability to reach the detector...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm426

    authors: Askri B,Manai K,Trabelsi A,Baccari B

    更新日期:2008-01-01 00:00:00

  • A THIN-LAYER LIF THERMOLUMINESCENCE DOSEMETER SYSTEM WITH FAST READOUT FOR THE USE IN PERSONAL DOSIMETRY SERVICES.

    abstract::A newly developed thermoluminescence dosemeter system is presented that is suitable for application in fields where personal monitoring of a large number of users is required. The system presented here is intended to be used as the upcoming main dosemeter for whole body dosimetry at the dosimetry service of the MPA NR...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv478

    authors: Walbersloh J,Busch F

    更新日期:2016-09-01 00:00:00

  • New Correction Factors Based on Seasonal Variability of Outdoor Temperature for Estimating Annual Radon Concentrations in UK.

    abstract::Indoor radon concentrations generally vary with season. Radon gas enters buildings from beneath due to a small air pressure difference between the inside of a house and outdoors. This underpressure which draws soil gas including radon into the house depends on the difference between the indoor and outdoor temperatures...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw270

    authors: Daraktchieva Z

    更新日期:2017-06-01 00:00:00

  • INTERCAL: long-term inter-comparison experiment for dose rate and spectrometric probes.

    abstract::The Schauinsland inter-calibration facility (INTERCAL) has been designed to enable long-term comparison experiments for 20 different dose rate probes from different networks. Two reference probes characterised by the European Radiation Dosimetry WG3 inter-calibration experiments in 2008 and 2009 have been installed at...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu039

    authors: Bleher M,Doll H,Harms W,Stöhlker U

    更新日期:2014-08-01 00:00:00

  • VISUALIZATION OF THE DNA REPAIR PROCESS IN MAMMALIAN CELLS TRANSFECTED WITH EGFP-EXPRESSING PLASMID DNA AFTER EXPOSURE TO X-RAYS IN VITRO.

    abstract::To investigate the repair process of DNA damage induced by ionizing radiation in isolation from various types of cytoplasmic damage, we transfected X-irradiated enhanced green fluorescent protein (EGFP)-expressing plasmid DNA into non-irradiated mammalian cells using lipofectamine. The repair kinetics of the irradiate...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy241

    authors: Nakaue H,Obata Y,Kaminaga K,Akimitsu N,Yokoya A

    更新日期:2019-05-01 00:00:00

  • Discussion on optimisation below dose limit for public using background-cancer-risk-based approach.

    abstract::To improve a radiological protection system, the lower bound of optimisation was discussed using a newly proposed background-cancer-risk-based approach. This approach provides a new finding that the standard deviation of the background cancer risk in Japan is 7.4 × 10(-5) y(-1). If this risk level corresponding to 1σ ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr150

    authors: Hattori T

    更新日期:2011-07-01 00:00:00

  • Qualifying the use of RIS data for patient dose by comparison with DICOM header data.

    abstract::A system was developed in 2008 to calculate patient doses using Radiology Information System (RIS) data and presents these data as a patient dose audit. One of the issues with this system was the quality of user-entered data. It has been shown that Digital Imaging and Communication in Medicine (DICOM) header data can ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr352

    authors: Wilde R,Charnock P,McDonald S,Moores BM

    更新日期:2011-09-01 00:00:00

  • The TSL neutron beam facility.

    abstract::A new quasi-monoenergetic neutron beam facility has been constructed at The Svedberg Laboratory (TSL) in Uppsala, Sweden. Key features include a neutron energy range of 11-175 MeV, high fluxes, user flux control, flexible neutron field size and shape, and spacious and easily accessible user area. The first results of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm006

    authors: Prokofiev AV,Blomgren J,Byström O,Ekström C,Pomp S,Tippawan U,Ziemann V,Osterlund M

    更新日期:2007-01-01 00:00:00

  • Response of the Nrf2 protection system in human monocytic cells after ionising irradiation.

    abstract::In response to reactive oxygen species (ROS) or electrophiles, the transcription factor nuclear factor-erythroid 2 (NF-E2)-related factor 2 (Nrf2) rapidly translocates into the nucleus and induces the expression of various antioxidant genes, such as heme oxygenase-1 (HO-1). Low linear energy transfer (LET) ionising ra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs201

    authors: Yoshino H,Kiminarita T,Matsushita Y,Kashiwakura I

    更新日期:2012-11-01 00:00:00

  • Assessment of gamma dose rates in air in Adana/Turkey.

    abstract::This study assesses the outdoor gamma absorbed dose levels in air of the Adana's region. The measurements were taken from 130 different sample points in this area by Eberline Smart Portable (ESP-2) with SPA-6 plastic scintillation detector. The outdoor gamma absorbed dose rates order from 40 to 145 nGy h(-1). Average ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn295

    authors: Degerlier M,Ozger G

    更新日期:2008-01-01 00:00:00

  • Investigation of radiation-induced multilayered signalling response of the inflammatory pathway.

    abstract::Ionising radiation exposure of cells might induce the perturbation of cell functions and, in particular, the activation or inhibition of several important pathways. This perturbation can cause the deregulation of both intra- and extra-cellular signalling cascades (such as the inflammatory pathway) and alter not only t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv132

    authors: Babini G,Ugolini M,Morini J,Baiocco G,Mariotti L,de Fatis PT,Liotta M,Ottolenghi A

    更新日期:2015-09-01 00:00:00

  • Design of a multi-element TEPC for neutron monitoring.

    abstract::Tissue-equivalent proportional counters (TEPCs) have long been considered suitable candidate instruments for more accurate neutron monitors in nuclear power plants. It has also been recognised that the production of truly light-weight devices based on TEPCs requires further effort directed towards increasing their sen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq538

    authors: Waker AJ,Aslam,Lori J

    更新日期:2011-02-01 00:00:00

  • Suggested diagnostic reference levels for paediatric X-ray examinations in India.

    abstract::Exposure of children to ionising radiation is considered to carry higher risk than that of adults; therefore a need to suggest diagnostic reference levels (DRLs) for the common paediatric diagnostic X-ray procedures was recognised for the X-ray machines meeting the requirements of the recently implemented Safety Code ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq458

    authors: Sonawane AU,Sunil Kumar JV,Singh M,Pradhan AS

    更新日期:2011-11-01 00:00:00

  • The measurements of thoron, radon and their decay products thanks to Pinocchio, Tengu and Trolls.

    abstract::In the present paper, the long noses of Pinocchio, Tengu and Trolls are used to measure, respectively, radon, thoron, and their decay products both by track-etch detectors and by Geiger-Müller (G-M) counters. Just recently, four new passive samplers (termed quatrefoil) have been developed which greatly simplify the de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq248

    authors: Tommasino L,Tokonami S,Tommasino PM

    更新日期:2010-10-01 00:00:00

  • Determination of the absorbed dose and the average LET of space radiation in dependence on shielding conditions.

    abstract::The HTR method, developed for determination of absorbed dose and average LET of mixed radiation fields in space, was applied during several space missions on space station MIR, space shuttles and satellites. The method utilises the changes of peak height ratios in the glow curves in dependence on the linear energy tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a032854

    authors: Vana N,Schoner W,Noll M,Fugger M,Akatov Y,Shurshakov V

    更新日期:1999-01-01 00:00:00

  • A simple physical phantom for an intercomparison exercise on 241Am activity determination in the skull.

    abstract::A simple hemispherical phantom has been designed and prepared for the EURADOS intercomparison exercise on (241)Am activity determination in the skull (2011-13). The phantom consists of three parts that substitute bone and soft tissues. (241)Am is deposited on the surfaces of the bone-substituting part. The design and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct213

    authors: Vrba T,Malátová I,Fojtík P,Fülöp M,Ragan P

    更新日期:2014-01-01 00:00:00

  • Protection from radon exposure at home and at work in the directive 2013/59/Euratom.

    abstract::In recent years, international organisations involved in radiation protection and public health have produced new guidance, recommendations and requirements aiming better protection from radon exposure. These organisations have often worked in close collaboration in order to facilitate the establishment of harmonised ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu101

    authors: Bochicchio F

    更新日期:2014-07-01 00:00:00

  • Use of various microdosimetric models for the prediction of radon induced damage in human lungs.

    abstract::Exposure to radon and radon decay products in some residential areas and at workplaces constitutes one of the greatest risks from natural sources of ionising radiation. Recently, increasing attention has been paid to the precise estimations of this health risk by numerous models. The compartmental model published in I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006173

    authors: Böhm R,Nikodémová D,Holý K

    更新日期:2003-01-01 00:00:00

  • A theoretical study on accurate measurements of thoron with airflow-through scintillation cell method.

    abstract::For accurate measurements of (220)Rn concentration with airflow-through scintillation cell method, a theoretical study was performed for discussing the influences of sampling flow rate, volumes of sampling tube and scintillation cell on the measurements. It is found that a high flow rate and a large inner volume of sc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq252

    authors: Tang F,Zhuo W,Zhao C,Chen B,Xu Y,He L

    更新日期:2010-10-01 00:00:00

  • DETERMINATION OF DIAGNOSTIC REFERENCE LEVEL IN ROUTINE EXAMINATIONS OF DIGITAL RADIOGRAPHY IN MAZANDARAN PROVINCE.

    abstract:INTRODUCTION:The main purpose of this study was to determine the diagnostic reference level (DRL) for routine digital radiography examinations in Mazandaran province. MATERIALS AND METHODS:Thirteen digital radiographic examinations at 18 high-patient-load radiography centres were investigated. The indirect dosimetry m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa074

    authors: Hoseini Motlagh Z,Shabestani Monfared A,Deevband MR,Abedi-Firouzjah R,Ghaemian N,Abdi R,Ebrahimnejad Gorji K

    更新日期:2020-08-03 00:00:00

  • FEASIBILITY OF DISPLAYED EXPOSURE INDEX IN IEC STANDARD FRAMEWORK AS A DOSE OPTIMISATION TOOL FOR DIGITAL RADIOGRAPHY SYSTEMS.

    abstract::International Electrotechnical Commission (IEC) established the framework for the use of exposure index (EI) for evaluating the exposure conditions with various digital systems. In this study, we investigated the feasibility of EI, as per the IEC, by comparing the EIs obtained through manual calculated and that displa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa052

    authors: Park H,Yoon Y,Tanaka N,Kim J,Kim J,Morishita J

    更新日期:2020-07-17 00:00:00

  • Application of the high-temperature ratio method for evaluation of the depth distribution of dose equivalent in a water-filled phantom on board space station Mir.

    abstract::A water-filled tissue equivalent phantom with a diameter of 35 cm was developed at the Institute for Biomedical Problems. Moscow. Russia. It contains four channels perpendicular to each other, where dosemeters can be exposed at different depths. Between May 1997 and February 1999 the phantom was installed at three dif...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005923

    authors: Berger T,Hajek M,Schöner W,Fugger M,Vana N,Akatov Y,Shurshakov V,Arkhangelsky V,Kartashov D

    更新日期:2002-01-01 00:00:00

  • Assessment of effective dose in paediatric CT examinations.

    abstract::Current concerns focus on the high doses encountered in computed tomography (CT) examinations as they are extending towards younger and more radiosensitive patients. Previous work produced conversion coefficients for effective dose (E) from dose-length product (DLP) for four anatomical body regions applicable to any p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr288

    authors: Dougeni E,Chapple CL,Willis J,Panayiotakis G

    更新日期:2011-09-01 00:00:00

  • Exposure estimates based on broadband ELF magnetic field measurements versus the ICNIRP multiple frequency rule.

    abstract::The evaluation of exposure to extremely low-frequency (ELF) magnetic fields using broadband measurement techniques gives satisfactory results when the field has essentially a single frequency. Nevertheless, magnetic fields are in most cases distorted by harmonic components. This work analyses the harmonic components o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu175

    authors: Paniagua JM,Rufo M,Jiménez A,Pachón FT,Carrero J

    更新日期:2015-02-01 00:00:00

  • Regional cooperation in RWM in the AO countries.

    abstract::Regional cooperation in radioactive waste management (RWM) in the Asian and Oceanic countries has been successfully developing for more than 20 y. At present, the Asian and Oceanic countries recognise that there are several projects under the regional cooperation, such as the Forum for Nuclear Cooperation in Asia (FNC...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr124

    authors: Ya-anant N,Thiangtrongjit S

    更新日期:2011-07-01 00:00:00

  • Accreditation of testing laboratories in dosimetry: the use of a flexible scope at the Competent Incorporation Measuring Body Jülich.

    abstract::The accreditation of the Competent Incorporation Measuring Body at Jülich includes incorporation monitoring by means of direct measurements of the body activity as well as by means of indirect determination of the body activity by radiochemical analysis of excreta samples. In both testing areas, it proved to be very u...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq360

    authors: Hill P,Froning M,Schläger M,Zoriy MV,Lennartz R

    更新日期:2011-03-01 00:00:00