Evaluation of solid state nuclear track detector stacks exposed on the international space station.

Abstract:

:The aim of the study was to investigate the contribution of secondary neutrons to the total dose inside the International Space Station (ISS). For this purpose solid-state nuclear track detector (SSNTD) stacks were used. Each stack consisted of three CR-39 sheets. The first and second sheets were separated by a Ti plate, and the second and third sheets sandwiched a Lexan polycarbonate foil. The neutron and proton responses of each sheet were studied through MC calculations and experimentally, utilising monoenergetic protons. Seven stacks were exposed in 2001 for 249 days at different locations of the Russian segment 'Zvezda'. The total storage time before and after the exposure onboard was estimated to be seven months. Another eight stacks were exposed at the CERF high-energy neutron field for calibration purposes. The CR-39 detectors were evaluated in four steps: after 2, 6, 12 and 20 h etching in 6 N NaOH at 70 degrees C (VB = 1.34 microm h(-1)). All the individual tracks were investigated and recorded using an image analyser. The stacks provided the averaged neutron ambient dose equivalent (H*) between 200 keV and 20 MeV, and the values varied from 39 to 73 microSv d(-1), depending on the location. The Lexan detectors were used to detect the dose originating from high-charge and high-energy (HZE) particles. These results will be published elsewhere.

journal_name

Radiat Prot Dosimetry

authors

Pálfalvi JK,Akatov Y,Szabó J,Sajó-Bohus L,Eördögh I

doi

10.1093/rpd/nch140

keywords:

subject

Has Abstract

pub_date

2004-01-01 00:00:00

pages

393-7

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

110/1-4/393

journal_volume

110

pub_type

杂志文章
  • DETERMINATION OF NEUTRON EFFECTIVE DOSES IN WHOLE BODY POINT SOURCE EXPOSURES.

    abstract::The objective of this work is to obtain fluence to effective dose conversion coefficients for neutron point sources, using the GEANT4 toolkit. These calculations aim to investigate the aspects of neutron transport in the human body through Monte Carlo simulation using the International Commission on Radiological Prote...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx286

    authors: Ribeiro RM,Souza-Santos D

    更新日期:2018-08-01 00:00:00

  • A comparative study of quality control in diagnostic radiology.

    abstract::The main objective of this comparative study was to evaluate the national quality assurance program for X-ray diagnostic radiology in Syrian governmental hospitals. Two periods were covered in this study, the first period was from 1986 to 1998 (52 hospitals and 149 X-ray machines were considered) and the second period...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn096

    authors: Kharita MH,Khedr MS,Wannus KM

    更新日期:2008-01-01 00:00:00

  • A dose index as a tool to estimate paediatric patient doses in digital projection radiography.

    abstract::Radiation exposure during childhood is estimated to have a lifetime risk up to seven times greater than exposures at adult age. Therefore, paediatric patient dose monitoring is a major concern in radiology. The aim of this study is to evaluate the validity of a dose index, displayed at the digital imaging and communic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr313

    authors: Garcia Castañon P,España Lopez ML,Fernandez Bedoya V,Bermudez Luna R,Rodriguez Martin G

    更新日期:2012-05-01 00:00:00

  • A review of the properties of the dosimetric systems and the quality assurance programmes of 48 dosimetric services in the European Union and Switzerland.

    abstract::This paper summarises the evaluation of the 1997 EURADOS questionnaire on dosimetric systems able to assess personal dose equivalent. In total, 56 approved dosimetric services in the European Union and Switzerland responded, together monitoring approximately 615,000 occupationally exposed persons. Of these services, 4...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006572

    authors: van Dijk JW,Bordy JM,Vanhavere F,Wernli C,Zamani-Valasiadou M

    更新日期:2001-01-01 00:00:00

  • A quality control programme for medical X-ray films in India.

    abstract::Medical X-ray films are continued to be the major image receptors in diagnostic radiology in India. About 9×10⁶ m² of medical X-ray films are used per annum for diagnostic imaging in India, and its magnitude may further increase as the number of diagnostic X-ray units is increasing rapidly. A national quality control ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq595

    authors: Sharma R,Sharma SD

    更新日期:2012-01-01 00:00:00

  • A new position recording system for the partial-body counter at KIT.

    abstract::The position of detectors used for partial-body counters relative to a measured person has considerable influence on the counting efficiency of low-energy photon emitters. To minimise reading errors and enhance reproducibility of position data, an electronic position recording system was installed in the partial-body ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq416

    authors: Hegenbart L,Breustedt B

    更新日期:2011-03-01 00:00:00

  • Natural radioactivity study in soil samples of South Konkan, Maharashtra, India.

    abstract::This study assesses the level of natural radioactivity due to radionuclides, ²³⁸U, ²³²Th and ⁴⁰K, in 50 soil samples collected from South Konkan, Maharashtra, India. The mean activity concentrations of ²³⁸U, ²³²Th and ⁴⁰K are 44.97 ± 1.22 Bq kg⁻¹, 59.70 ± 2.17 Bq kg⁻¹ and 217.51 ± 8.75 Bq kg⁻¹, respectively, measured ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct131

    authors: Dhawal SJ,Phadatare MR,Thorat ND,Kulkarni GS,Pawar SH

    更新日期:2013-12-01 00:00:00

  • Low-cost extrapolation method for maximal LTE radio base station exposure estimation: test and validation.

    abstract::An experimental validation of a low-cost method for extrapolation and estimation of the maximal electromagnetic-field exposure from long-term evolution (LTE) radio base station installations are presented. No knowledge on downlink band occupation or service characteristics is required for the low-cost method. The meth...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs307

    authors: Verloock L,Joseph W,Gati A,Varsier N,Flach B,Wiart J,Martens L

    更新日期:2013-06-01 00:00:00

  • Panel discussion: Do non-targeted effects impact the relation between microdosimetry and risk?

    abstract::An invited panel discussed with the participants of the Symposium their views on the impact of non-targeted effects on the relationship between microdosimetry and risk. The discussion was wide ranging and lively, with divergences of opinion. At one end was the view that understanding microscopic features and distribut...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq393

    authors: Goodhead DT

    更新日期:2011-02-01 00:00:00

  • RESULTS OF THE JOINT IAEA/ARPANSA INTERCOMPARISON EXERCISE ON WHOLE BODY DOSEMETERS FOR PHOTONS IN ASIA AND THE PACIFIC REGION.

    abstract::An intercomparison exercise (IC) on whole body dosemeters to determine the quantity personal dose equivalent Hp (10) in photon radiation fields was jointly organised and conducted by the International Atomic Energy Agency (IAEA) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) for individual...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz182

    authors: Rizk C,Long S,Okyar HB,Baradaran S,Al Fares E,Sangau JK,Shah BR

    更新日期:2019-12-31 00:00:00

  • New diagnostic reference level for full-field digital mammography units.

    abstract::The diagnostic reference level (DRL) has generally been defined as the 75th percentile of the distributions of mean doses observed on a sample of standard-sized patients, but for mammography, the 95th percentile has been used. In this study, the 75th and 95th percentiles are estimated for 26 full-field digital mammogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct136

    authors: Hauge IH,Bredholt K,Olerud HM

    更新日期:2013-12-01 00:00:00

  • Minimising activity and dose with enhanced image quality by radiopharmaceutical administrations.

    abstract::Owing to the introduction of new diagnostic procedures, such as computed tomography (CT), positron emission tomography (PET) and single photon emission computed tomography (SPECT), the individual dose caused by medical exposures has grown rapidly in the last years. This is especially a subject to radiation protection ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq104

    authors: Hoeschen C,Mattsson S,Cantone MC,Mikuz M,Lacasta C,Ebel G,Clinthorne N,Giussani A

    更新日期:2010-04-01 00:00:00

  • Development of a new thoron progeny detector based on SSNTD and the collection by an electric field.

    abstract::The importance of (220)Rn (thoron) progeny for human exposure has been widely recognised in the past decades. Since no stable equilibrium factor was found between indoor thoron and its progeny, and the concentration of thoron progeny varies with time, it is necessary to develop detectors for long-term measurement that...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr078

    authors: Bi L,Tschiersch J,Meisenberg O,Wielunski M,Li JL,Shang B

    更新日期:2011-05-01 00:00:00

  • Accreditation of testing laboratories in dosimetry: the use of a flexible scope at the Competent Incorporation Measuring Body Jülich.

    abstract::The accreditation of the Competent Incorporation Measuring Body at Jülich includes incorporation monitoring by means of direct measurements of the body activity as well as by means of indirect determination of the body activity by radiochemical analysis of excreta samples. In both testing areas, it proved to be very u...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq360

    authors: Hill P,Froning M,Schläger M,Zoriy MV,Lennartz R

    更新日期:2011-03-01 00:00:00

  • Bayesian approach for quantifying the uncertainty of neutron doses derived from spectrometric measurements.

    abstract::Bayesian methods provide a unified framework for combining information in the presence of uncertainty. All uncertainties that enter into the description of a measurement are modelled using probability distributions, and these are handled according to the rules of probability theory, ensuring that the approach is free ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl096

    authors: Reginatto M

    更新日期:2006-01-01 00:00:00

  • Monte Carlo simulation of neutron backscattering from concrete walls in the dense plasma focus laboratory of Bologna University.

    abstract::Between 2001 and 2003 a 3.2 kJ dense plasma focus (DPF) device has been built at the Montecuccolino Laboratory of the Department of Energy, Nuclear and Environmental Control Engineering (DIENCA) of the University of Bologna. A DPF is a pulsed device in which deuterium nuclear fusion reactions can be obtained through t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci113

    authors: Frignani M,Mostacci D,Rocchi F,Sumini M

    更新日期:2005-01-01 00:00:00

  • Organ dose conversions from ESR measurements using tooth enamel of atomic bomb survivors.

    abstract::Dose conversions were studied for dosimetry of atomic bomb survivors based upon electron spin resonance (ESR) measurements of tooth enamel. Previously analysed data had clarified that the tooth enamel dose could be much larger than other organ doses from a low-energy photon exposure. The radiation doses to other organ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr408

    authors: Takahashi F,Sato K

    更新日期:2012-03-01 00:00:00

  • Dose-image quality optimisation in digital chest radiography.

    abstract::A range of techniques has been developed in conventional radiography for the chest, because of technical difficulties in imaging the wide variation of tissue densities. These techniques can differ significantly in tube potential selection, for scatter reduction and in application of manual or automatic exposure contro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch546

    authors: Doyle P,Martin CJ,Gentle D

    更新日期:2005-01-01 00:00:00

  • RADIOECOLOGICAL IMPACT AND THE ASSOCIATED HAZARDS DUE TO NORM FROM OIL AND GAS PRODUCTION FACILITY IN THE WESTERN DESERT OF EGYPT.

    abstract::An oil and gas production facility in the western desert of Egypt was investigated for possible radiation risks due to the routine operation. Radium-226, Radium-228 and Potassium-40 were assessed in the soil samples collected from the adjacent soakaway pond. The average 226Ra, 228Ra and 40K activity concentrations wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa084

    authors: Ebaid YY,Hassan Y,Elshemey WM

    更新日期:2020-08-28 00:00:00

  • Feminist theoretical perspectives on ethics in radiology.

    abstract::The substantive safety of radiological and other medical procedures can be radically reduced by unconscious factors governing scientific thought. In addition, the historical exclusion of women from these disciplines has possibly skewed their development in directions that now need to be addressed. This paper focuses o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp055

    authors: Condren M

    更新日期:2009-07-01 00:00:00

  • MCNPX CALCULATIONS OF SPECIFIC ABSORBED FRACTIONS IN SOME ORGANS OF THE HUMAN BODY DUE TO APPLICATION OF 133Xe, 99mTc and 81mKr RADIONUCLIDES.

    abstract::Monte Carlo simulations were performed to evaluate treatment doses with wide spread used radionuclides 133Xe, 99mTc and 81mKr. These different radionuclides are used in perfusion or ventilation examinations in nuclear medicine and as indicators for cardiovascular and pulmonary diseases. The objective of this work was ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx181

    authors: Jovanovic Z,Krstic D,Nikezic D,Ros JMG,Ferrari P

    更新日期:2018-03-01 00:00:00

  • Radon in underground waters as a natural analogue to study the escape of CO2 in geological repositories.

    abstract::Activity concentrations of dissolved (222)Rn and (226)Ra were measured in several underground aquifers, which are candidates for repositories or for the study of analogue natural escapes of CO2. The concentration of both radionuclides in water was determined using liquid scintillation counting. The values obtained for...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv232

    authors: Martín Sánchez A,Ruano Sánchez AB,de la Torre Pérez J,Jurado Vargas M

    更新日期:2015-11-01 00:00:00

  • Investigation of combined unfolding of neutron spectra using the UMG unfolding codes.

    abstract::An investigation of the simultaneous unfolding of data from neutron spectrometers using the UMG codes MAXED and GRAVEL has been performed. This approach involves combining the data from the spectrometers before unfolding, thereby performing a single combined unfolding of all the data to yield a final combined spectrum...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm082

    authors: Roberts NJ

    更新日期:2007-01-01 00:00:00

  • Induced radioactivity in the ESRF storage ring.

    abstract::The new French radiation protection legislation requires the definition of the zoning of accelerator facilities with respect to radioactive waste. This activation inside the ESRF 6 GeV storage ring is essentially due to photonuclear reactions. This paper describes the first results of Monte Carlo calculations that wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci070

    authors: Berkvens P

    更新日期:2005-01-01 00:00:00

  • Spot measurements of intermediate frequency electric fields in the vicinity of compact fluorescent lamps.

    abstract::Starting in 2009, certain types of incandescent light bulbs will be withdrawn from the market in the European Union and elsewhere. However, compact fluorescent lamps that are among the candidates to replace them produce intermediate frequency electric fields (EFs) much higher than any other device or appliance previou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq276

    authors: Bakos J,Nagy N,Juhász P,Thuróczy G

    更新日期:2010-12-01 00:00:00

  • A TLD-based personal dosemeter system for aircrew monitoring.

    abstract::Evaluation of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) according to the high-temperature ratio (HTR) method enables the determination of the dose-average linear energy transfer (LET), the mean quality factor and the dose equivalent in mixed radiation fields of unknown composition. The neutron contribution is ass...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch209

    authors: Hajek M,Berger T,Vana N

    更新日期:2004-01-01 00:00:00

  • Parallel FD-TD simulation of radiobase antennae.

    abstract::The rigorous characterisation of the behaviour of a radiobase antenna for wireless communication systems is a hot topic both for antenna or communication system design and for radioprotection-hazard reasons. Such a characterisation deserves a numerical solution, and the use of a finite-difference time-domain (FD-TD) a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006699

    authors: Catarinucci L,Palazzari P,Tarricone L

    更新日期:2001-01-01 00:00:00

  • A minimally invasive method to evaluate 131I kinetics in blood.

    abstract::The dose limiting factor for 131I therapy in patients with thyroid cancer is myelotoxicity, thus an accurate determination of radioiodine activity in the red marrow is of paramount importance. The reference method for red marrow dosimetry in radiometabolic therapy is based on the measurement of radioiodine kinetics, p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch041

    authors: Traino AC,Di Martino F,Boni G,Mariani G,Lazzeri M

    更新日期:2004-01-01 00:00:00

  • Exposures from nuclear medicine diagnostic procedures: the dose impact on the Aosta Valley population.

    abstract::The present work evaluates the per-procedure, annual collective and per-capita effective doses to the Aosta Valley region population from nuclear medicine (NM) examinations performed from 2005 to 2011 at the regional NM department. Based on its demographical and socioeconomics characteristics, this area can be conside...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct158

    authors: Aimonetto S,Arrichiello C,Peruzzo Cornetto A,Catuzzo P,Zeverino M,Poti C,Meloni T,Pasquino M,Tofani S

    更新日期:2013-12-01 00:00:00

  • Dosimetric data and radiation risk analysis for new procedures in interventional cardiology.

    abstract::The purpose of this study was to evaluate radiation doses to the patients and operators during interventional cardiology procedures, with a particular focus on the transcatheter aortic valve implantation (TAVI). Patient doses for 5549 diagnostic and therapeutic procedures and 76 TAVI were examined, as well as occupati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq208

    authors: Signorotto P,del Vecchio A,Montorfano M,Maisano F,Giagnorio M,Bellanca R,Colombo A,Calandrino R

    更新日期:2010-12-01 00:00:00