A quality control programme for medical X-ray films in India.

Abstract:

:Medical X-ray films are continued to be the major image receptors in diagnostic radiology in India. About 9×10⁶ m² of medical X-ray films are used per annum for diagnostic imaging in India, and its magnitude may further increase as the number of diagnostic X-ray units is increasing rapidly. A national quality control programme was initiated for testing the medical X-ray films of various suppliers/manufacturers so that optimum quality film can only be used in diagnostic radiography examinations. X-ray laboratory of Radiological Physics and Advisory Division, Bhabha Atomic Research Centre was recognised as national film testing laboratory. A dedicated test phantom was fabricated as per the prescription of International Organization for Standardization (ISO 9236-I, 1996), simulating the attenuation and scatter properties of chest of an average patient for periodic X-ray sensitometric evaluations of the medical X-ray films. The basic fog, speed, latitude, maximum optical density, uniformity and artefacts of all the films tested so far were found well within the requirements specified in the national standards. The average gradient for a few blue and green sensitive films were found less than the specified value. Suppliers/manufacturers of such films were advised to improve the performance quality of their films.

journal_name

Radiat Prot Dosimetry

authors

Sharma R,Sharma SD

doi

10.1093/rpd/ncq595

subject

Has Abstract

pub_date

2012-01-01 00:00:00

pages

51-7

issue

1

eissn

0144-8420

issn

1742-3406

pii

ncq595

journal_volume

148

pub_type

杂志文章
  • The history of radon from a Swedish perspective.

    abstract::Beginning in the 16th century, what was later found to be radon was thought to be causing sickness among miners. During the first decades of the 20th century, exposure to radon was seen as being healthy. During the 1940s, 1950s and 1960s researchers thought that the gamma radiation in residences could produce genetic ...

    journal_title:Radiation protection dosimetry

    pub_type: 历史文章,杂志文章,评审

    doi:10.1093/rpd/nch318

    authors: Swedjemark GA

    更新日期:2004-01-01 00:00:00

  • DESIGN IMPROVEMENT OF A LIQUID-MODERATOR-BASED NEUTRON SPECTROMETER FOR BNCT.

    abstract::Boron neutron capture therapy is known to be an effective radiation cancer therapy that requires neutron irradiation. A neutron field generated by an accelerator-based neutron source has various energy spectra, and it is necessary to evaluate the neutron spectrum in the treatment field. However, the method used to mea...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx237

    authors: Tamaki S,Kusaka S,Sato F,Murata I

    更新日期:2018-08-01 00:00:00

  • STRUCTURAL ANALYSIS OF DNA REPAIR PROTEIN XRCC4 APPLYING CIRCULAR DICHROISM IN AN AQUEOUS SOLUTION.

    abstract::We applied circular dichroism (CD) spectral analysis to obtain the secondary structure of the DNA repair protein XRCC4, with a focus on its C-terminus. Using synchrotron radiation as a light source across a wide range of wavelengths, including vacuum ultraviolet (UV) light from 180 to 200 nm and UV light from 200 to 2...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy275

    authors: Nishikubo K,Izumi Y,Matsumoto Y,Fujii K,Matsuo K,Yokoya A

    更新日期:2019-05-01 00:00:00

  • Evaluation of occupational exposure to naturally occurring radioactive materials in the Iranian ceramics industry.

    abstract::Zircon contains small amounts of uranium, thorium and radium in its crystalline structure. The ceramic industry is one of the major consumers of zirconium compounds that are used as an ingredient at ∼10-20 % by weight in glaze. In this study, seven different ceramic factories have been investigated regarding the prese...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq441

    authors: Fathabadi N,Farahani MV,Amani S,Moradi M,Haddadi B

    更新日期:2011-06-01 00:00:00

  • Retrospective dosimetry related to chronic environmental exposure.

    abstract::Radioactive contamination of the environment occurred in the early fifties as a result of the releases from the Mayak plutonium production complex (Southern Urals, Russia). The releases of liquid wastes into the Techa river resulted in chronic exposure of 30,000 residents of the riverside communities. Since 1951 90Sr ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a032381

    authors: Degteva MO,Kozheurov VP,Tolstykh EI

    更新日期:1998-01-01 00:00:00

  • On a model-based approach to radiation protection.

    abstract::There is a preoccupation with linearity and absorbed dose as the basic quantifiers of radiation hazard. An alternative is the fluence approach, whereby radiation hazard may be evaluated, at least in principle, via an appropriate action cross section. In order to compare these approaches, it may be useful to discuss th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006828

    authors: Waligórski MP

    更新日期:2002-01-01 00:00:00

  • A comparative study of quality control in diagnostic radiology.

    abstract::The main objective of this comparative study was to evaluate the national quality assurance program for X-ray diagnostic radiology in Syrian governmental hospitals. Two periods were covered in this study, the first period was from 1986 to 1998 (52 hospitals and 149 X-ray machines were considered) and the second period...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn096

    authors: Kharita MH,Khedr MS,Wannus KM

    更新日期:2008-01-01 00:00:00

  • DEVELOPMENT AND APPLICATION OF SOLID FORMS OF CaSO4:Dy THERMOLUMINESCENT DOSEMETERS IN RADIATION PROTECTION DOSIMETRY-A REVIEW.

    abstract::CaSO4:Dy is a reliable high-sensitive themoluminescent phosphor useful for low-level and high-level radiation measurements as it exhibits fading free linear dose response with a single glow peak at ~230°C in these dose regions. For large-scale radiation protection dosimetry service, it is embedded in Teflon matrix wit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncx287

    authors: Lakshmanan A

    更新日期:2018-10-01 00:00:00

  • A very low-background gamma-ray counting facility in the Baradello underground laboratory.

    abstract::An underground station for the measurement of low-level radioactivity is in operation in Northern Italy in the town of Como under the Baradello hill. The rock cover is -300 m water equivalent. This paper reports about the preliminary measurements carried out to characterise the site of the Baradello hill and the insta...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci163

    authors: Pellicciari M,Fascilla A,Giuliani A,Pedretti M,Cesana A,Garlati L,Terrani M,Raselli GL

    更新日期:2005-01-01 00:00:00

  • NATURAL RADIONUCLIDES IN AGRICULTURAL PLANTS FROM NORTHERN THAILAND.

    abstract::Thailand is predominantly an agricultural country. The Northern Region occupies the second largest cultivated land area in the country. To establish baseline data for future environmental monitoring, seventy-nine plant samples including vegetables, fruits and tobaccos and their relevant soils were collected from the m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz081

    authors: Kritsananuwat R,Kranrod C,Chanyotha S,Ploykrathok T,Sriploy P

    更新日期:2019-10-01 00:00:00

  • ESTE-DECISION SUPPORT SYSTEM FOR NUCLEAR AND RADIOLOGICAL ACCIDENTS.

    abstract::Described are functions, models and approaches of software tool Emergency Source Term code (ESTE), which is decision support system for crisis staff in case of nuclear or radiological accidents. The first task of ESTE in emergency situation at nuclear facility is to evaluate state of reactor core or state of fuel in s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz226

    authors: Fojcíková E,Lipták Ľ,Krpelanová M,Chylý M,Čarný P

    更新日期:2019-12-31 00:00:00

  • Spot measurements of intermediate frequency electric fields in the vicinity of compact fluorescent lamps.

    abstract::Starting in 2009, certain types of incandescent light bulbs will be withdrawn from the market in the European Union and elsewhere. However, compact fluorescent lamps that are among the candidates to replace them produce intermediate frequency electric fields (EFs) much higher than any other device or appliance previou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq276

    authors: Bakos J,Nagy N,Juhász P,Thuróczy G

    更新日期:2010-12-01 00:00:00

  • Radon measurements in the caves of Zonguldak (Turkey).

    abstract::There are approximately 20 caves of limestone origin in Zonguldak (Turkey). In this study, the results of atmospheric radon measurements performed for two caves are presented. These caves, Gökgöl and Cehennemağzi, are open to tourism. Gökgöl Cave is the longer, at nearly 3,200 m in length. Cehenennemağzi is a pit-type...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci326

    authors: Aytekin H,Baldik R,Celebi N,Ataksor B,Tasdelen M,Kopuz G

    更新日期:2006-01-01 00:00:00

  • INITIAL EVALUATION OF INDIVIDUAL DOSES IN THE EARLY PHASE OF A NUCLEAR REACTOR ACCIDENT BASED ON IN-VIVO MONITORING DATA AND SIMULATED RADIOLOGICAL CONSEQUENCES.

    abstract::In the early phase of a nuclear reactor accident, in-vivo monitoring of impacted population would be highly useful to detect potential contamination during the passage of the cloud and to estimate the dose from inhalation of measured radionuclides. However, it would be important to take into account other exposure com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy277

    authors: Challeton-de Vathaire C,Quentric E,Didier D,Blanchardon E,Davesne E,Rannou A,Agarande M,Renaud-Salis V,Franck D

    更新日期:2019-11-30 00:00:00

  • The natural radioactivity contents in feed coals from the lignite-fired power plants in Western Anatolia, Turkey.

    abstract::Lignite burning is one of the sources of technologically enhanced exposure to humans from natural radionuclides. In the preliminary study, part of the survey, the activity concentrations of (226)Ra, (232)Th and (40)K in 112 samples of feed lignites from seven lignite-fired power plants in Western Anatolia (Seyitömer, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq210

    authors: Cam NF,Yaprak G,Eren E

    更新日期:2010-12-01 00:00:00

  • Radiation-induced DNA damage responses.

    abstract::The amazing feature of ionising radiation (IR) as a DNA damaging agent is the range of lesions it induces. Such lesions include base damage, single strand breaks (SSBs), double strand breaks (DSBs) of varying complexity and DNA cross links. A range of DNA damage response mechanisms operate to help maintain genomic sta...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncl495

    authors: Jeggo P,Löbrich M

    更新日期:2006-01-01 00:00:00

  • Radiation exposure and disease questionnaires of early entrants after the Hiroshima bombing.

    abstract::It is popularly known that people who entered into the ground-zero area shortly after the atomic bombings in Hiroshima and Nagasaki suffered from various syndromes similar to acute radiation effects. External exposures from neutron-induced radionuclides in soil have recently been reassessed based on DS02 calculations ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr370

    authors: Imanaka T,Endo S,Kawano N,Tanaka K

    更新日期:2012-03-01 00:00:00

  • Combined TL and 10B-alanine ESR dosimetry for BNCT.

    abstract::The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with (10)B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch110

    authors: Bartolotta A,D'Oca MC,Lo Giudice B,Brai M,Borio R,Forini N,Salvadori P,Manera S

    更新日期:2004-01-01 00:00:00

  • Comparison of two JAERI phantoms and the problems discovered.

    abstract::During the course of an intercomparison exercise it was possible to compare two JAERI phantoms with each other by using a multi-energy photon emitting lung set (241Am/152Eu). One belonged to the IAEA (Vienna), the other belonged to the Human Monitoring Laboratory (Ottawa). The intercomparison of the phantoms showed th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006511

    authors: Kramer GH,Hauck BM

    更新日期:2001-01-01 00:00:00

  • Computed tomography dose index for head CT in northern Nigeria.

    abstract::Computed tomography dose index w and dose length product were recorded for the purpose of developing diagnostic reference levels (DRLs) for radiation dose optimisation. The study was conducted in three radiology departments with CT centres in Northern Nigeria. Data were collected from 54 consenting adult participants ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncv188

    authors: Garba I,Engel-Hills P,Davidson F,Tabari AM

    更新日期:2015-07-01 00:00:00

  • The resulting skin dose in two-view mammography examinations.

    abstract::The entrance surface dose (ESD) (skin dose) and its variation due to overlapping radiation fields at mammography have been experimentally investigated on patients during two-view mammography screening examinations of both breasts and on phantoms of silicon gel. Measurements were done using multiple thermoluminescence ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq077

    authors: Adliene D,Cibulskaite I,Laurikaitiene J,Adlys G

    更新日期:2010-04-01 00:00:00

  • Radioactivity monitoring in ground level air in Belgrade urban area.

    abstract::Concentrations of beryllium-7 ((7)Be), lead-210 ((210)Pb) and caesium-137 ((137)Cs) were measured at two sites in the city of Belgrade (Serbia). One monitoring site was located in the central city area with heavy traffic and the other within the Institute of Nuclear Sciences Vinca, in the suburbs. Presented data cover...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq211

    authors: Todorovic D,Popovic D,Nikolic J,Ajtic J

    更新日期:2010-12-01 00:00:00

  • Radiation safety assessment of a system of small reactors for distributed energy.

    abstract::A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, dee...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci208

    authors: Odano N,Ishida T

    更新日期:2005-01-01 00:00:00

  • Radiation protection issues for laser-based accelerators.

    abstract::Radiation particles, besides their application to fundamental research, are widely applied in all fields of science (medicine, material science, chemistry, etc.). Up to today the radiations were produced by radiation sources such as accelerators, X-ray tubes, radioactive sources with the well-known problems of costs, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr239

    authors: Esposito A

    更新日期:2011-07-01 00:00:00

  • Feminist theoretical perspectives on ethics in radiology.

    abstract::The substantive safety of radiological and other medical procedures can be radically reduced by unconscious factors governing scientific thought. In addition, the historical exclusion of women from these disciplines has possibly skewed their development in directions that now need to be addressed. This paper focuses o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp055

    authors: Condren M

    更新日期:2009-07-01 00:00:00

  • Measured proton sensitivities of bubble detectors.

    abstract::The neutron dose equivalent in aircraft is measured using commercial bubble detectors, but at high altitudes there are not only neutrons but also protons. Bubble detectors have been used because they are considered not to be sensitive to protons, but this has been the subject of only a few studies. In this study, by i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch330

    authors: Takada M,Kitamura H,Koi T,Nakamura T,Fujitaka K

    更新日期:2004-01-01 00:00:00

  • Independent regulatory examination of radiation situation in the areas of spent nuclear fuel and radioactive wastes storage in the Russian far east.

    abstract::This paper describes the findings of the radiation situation analysis on-site near Sysoeva and Razbojnik Bays. The results of radiation monitoring performed by radiological laboratory of DalRAO and studies performed by the experts from the Burnasyan Federal Medical Biophysical Centre have been used in the course of an...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr135

    authors: Shandala NK,Kiselev SM,Lucyanec AI,Titov AV,Seregin VA,Isaev DV,Akhromeev SV

    更新日期:2011-07-01 00:00:00

  • A MULTI-ELEMENT THICK GAS ELECTRON MULTIPLIER-BASED MICRODOSEMETER FOR MEASUREMENT OF NEUTRONS DOSE-EQUIVALENT: A MONTE CARLO STUDY.

    abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx024

    authors: Moslehi A,Raisali G

    更新日期:2017-11-01 00:00:00

  • Development of lung and soft tissue substitutes for photons.

    abstract::The use of solid tissue substitutes is a well-accepted and common practice in dosimetric studies and in the production of counting standards for radiological protection. However, only a few solid tissue substitutes simulating a particular body tissue with respect to a set of physical characteristics are commercially a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci018

    authors: Kinase S,Kimura M,Noguchi H,Yokoyama S

    更新日期:2005-01-01 00:00:00

  • Experimental simulation of A-bomb gamma ray spectra for radiobiology studies.

    abstract::Improved radiation protection of humans requires a better understanding of the mechanisms of radiation action and accurate estimates of radiation risk for both internal and external radiations. The Japanese atomic bomb survivors represent one of the most important sources of human data on the late carcinogenic effects...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006532

    authors: Pattison JE,Hugtenburg RP,Charles MW,Beddoe AH

    更新日期:2001-01-01 00:00:00