Abstract:
:Bleach, nitrite, chromate, and hydrogen peroxide-peroxidase are effective urine adulterants used by the illicit drug users to conceal marijuana-positive results. Methods for detecting nitrite and chromate are available. Effects of other oxidizing agents that could possibly be used as adulterants and are difficult to detect or measure are presented in this report. Urine samples containing 40 ng/mL of 11-nor-delta9-THC-9-carboxylic acid (THC-acid) were treated with 10 mmol/L of commonly available oxidizing agents. Effects of horseradish peroxidase of activity 10 unit/mL and extracts from 2.5 g of red radish (Raphanus sativus, Radicula group), horseradish (Armoracia rusticana), Japanese radish (Raphanus sativus, Daikon group), and black mustard seeds (Brassica nigra), all with 10 mmol/L of hydrogen peroxide, were also examined. After 5 min, 16 h and 48 h of exposure at room temperature (23 degrees C) the specimens were tested by a gas chromatographic-mass spectrometric method for THC-acid. A control group treated with sodium hydrosulfite to reduce the oxidants, was also tested to investigate the effect of oxidizing agents on THC-acid in the extraction method. THC-acid was lost completely in the extraction method when treated with chromate, nitrite, oxone, and hydrogen peroxide/ferrous ammonium sulfate (Fenton's reagent). Some losses were also observed with persulfate and periodate (up to 25%). These oxidants, and other oxidizing agents like permanganate, periodate, peroxidase, and extracts from red radish, horseradish, Japanese radish and black mustard seeds destroyed most of the THC-acid (> 94%) within 48 h of exposure. Chlorate, perchlorate, iodate, and oxychloride under these conditions showed little or no effect. Complete loss was observed when THC-acid was exposed to 50 mmol/L of oxychloride for 48 h. Several oxidizing adulterants that are difficult to test by the present urine adulterant testing methods showed considerable effects on the destruction of THC-acid. The time and temperature for these effects were similar to those used by most laboratories to collect and test specimens. In several cases, the loss of THC-acid was > 94%.
journal_name
J Anal Toxicoljournal_title
Journal of analytical toxicologyauthors
Paul BD,Jacobs Adoi
10.1093/jat/26.7.460keywords:
subject
Has Abstractpub_date
2002-10-01 00:00:00pages
460-3issue
7eissn
0146-4760issn
1945-2403journal_volume
26pub_type
杂志文章abstract::We report the validation of a quantitative method for paraquat in plasma and urine using high-performance liquid chromatography (HPLC) with ultraviolet detection (260 nm). Furthermore, we illustrate the use of this method in the clinic (over five years), in conjunction with a qualitative urine paraquat screen. Urine o...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/25.6.456
更新日期:2001-09-01 00:00:00
abstract::Synthetic cathinones have recently emerged as a substitute for common drugs of abuse. Synthetic cathinones can elicit powerful adverse effects such as delusions, hallucinations and potentially dangerous behavior. To develop a method to analyze 10 synthetic cathinones in oral fluid, we implemented a combined approach o...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/bkt080
更新日期:2013-11-01 00:00:00
abstract::This work was aimed at developing and validating a hydrophilic interaction chromatography (HILIC)-electrospray ionization (ESI)-ion trap-tandem mass spectrometric method for identification and quantification of ethyl glucuronide (ETG) and ethyl sulfate (ETS) as ethanol biomarkers and at employing this method for analy...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/34.5.261
更新日期:2010-06-01 00:00:00
abstract::Prolintane is a sympathomimetic amine with pharmacologic properties similar to d-amphetamine. Side effects include insomnia, nervousness, and irritability. Overdoses of prolintane may cause hallucinations, psychosis, and death. The drug is commonly prescribed in Africa, Australia, and Europe but is not available in th...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/31.7.415
更新日期:2007-09-01 00:00:00
abstract::An arsenic death was investigated six and one half years after the demise. Analysis of tissue embedded in paraffin blocks demonstrated toxic concentrations. Spectrophotometry was employed with the use of a hydride generator to provide specificity and sensitivity to less than 0.05 microgram. ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/6.5.260
更新日期:1982-09-01 00:00:00
abstract::Due to the lack of certified reference material, a reliable quantification in complex postmortem matrices can only be performed either by the addition of isotope-labelled standards or by the standard addition method. Although standard addition is a basic quantification procedure, its practical implementation is challe...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/bkv078
更新日期:2015-11-01 00:00:00
abstract::Salicylate excretion was studied in the breast milk of a nursing mother (Patient A) taking chronic therapeutic doses of aspirin, and caffeine excretion was monitored in the breast milk of a nursing mother (Patient B) who was a heavy coffee drinker. Salicylate concentrations were maximal in serum at 2.25 hours (10.8 mg...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/6.2.64
更新日期:1982-03-01 00:00:00
abstract::We present a method that permits the simultaneous analysis of carbamazepine (CBZ) and its major biotransformation products, carbamazepine-10,11-epoxide (CBZ-E) and carbamazepine-10,11-dihydroxide (CBZ-diOH), in plasma samples. The method consists of plasma extraction in alkaline medium with NaCl added using chloroform...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/16.2.88
更新日期:1992-03-01 00:00:00
abstract::The U.S. Drug Enforcement Administration has several different systems for collecting information on drugs of abuse. One is an early warning system, which collects information to provide scientific data and interpretation on drug abuse. Another is the collection of data from evidence submitted to DEA laboratories. Thi...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/11.6.237
更新日期:1987-11-01 00:00:00
abstract::Intoxications with the antifreeze constituent ethylene glycol (EG) occur infrequently, but may be fatal if not recognized and treated promptly. The aim of the present work was to develop an analytical method for rapid diagnosis of EG poisoning and for monitoring EG removal by hemodialysis. EG was measured by gas chrom...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/17.4.218
更新日期:1993-07-01 00:00:00
abstract::Benzoylecgonine (BZE) extraction from urine was explored using Cerex Polycrom Clin II solid-phase extraction (SPE) columns and the Speedisk 48 Pressure Processor as an alternative to the Prep1 automated sample processor and XTRX Type RP/W columns. Linearity for urine standards extracted using the Cerex-Speedisk method...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/25.7.616
更新日期:2001-10-01 00:00:00
abstract::An improved method has been developed for the quantitative determination of cyanide in human blood by headspace gas chromatography with electron-capture detection. In this novel method, cyanide was detected after conversion of hydrogen cyanide into cyanogen chloride by a reaction with chloramine T. The advantage of th...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/18.4.205
更新日期:1994-07-01 00:00:00
abstract::A rapid and simple method is described for the separation of quinidine (Q), its metabolites 3-hydroxyquinidine (30HQ) and 2'oxoquinidinone (QD) as well as the quinidine salt contaminant, dihydroquinidine (DHQ) in plasma by high pressure liquid chromatography (HPLC). A silica column was used with methanol: 1 N ammonium...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/6.3.153
更新日期:1982-05-01 00:00:00
abstract::A sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for the quantitation of oxymorphone (OM) in human whole blood and liver. Sample preparation was done by solid-phase extraction, using deuterated OM as the internal standard. Separation was achieved using a Waters Aquity UPLC ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/bkt077
更新日期:2013-10-01 00:00:00
abstract::Fentanyl and its analogs, such as acetylfentanyl, have become a concern for potential abuse. Fentanyl compliance monitoring and urine drug testing are becoming increasingly necessary; however, a limited number of fentanyl immunoassays have been validated for clinical use. The purpose of this study was to validate the ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/bku103
更新日期:2014-11-01 00:00:00
abstract::This manuscript details a validated liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry (LC-APCI-MS-MS) method for the quantification of methadone and its metabolites 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and 2-ethyl-5-methyl-3,3-diphenylpyroline (EMDP) in 0.5 mL ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/31.5.265
更新日期:2007-06-01 00:00:00
abstract::A simple and sensitive method for determination of N,N-dimethyltryptamine (DMT) by gas chromatography (GC) with surface ionization detection (SID) is presented. Whole blood or urine, containing DMT and gramine (internal standard), was subjected to solid-phase extraction with a Sep-Pak C18 cartridge before analysis by ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/21.1.36
更新日期:1997-01-01 00:00:00
abstract::An improved method for the simultaneous determination of cocaine and its metabolites, benzoylecgonine (BE), norcocaine, and ecgoninemethylester (EME), in rat plasma and urine is described. Following derivatization of EME to p-fluorococaine, chromatography was performed on two high-performance liquid chromatography (HP...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/24.6.438
更新日期:2000-09-01 00:00:00
abstract::Metabolism experiments were conducted with rats dosed with nine azo dyes based on dimethyl-, dimethoxy-, or dichlorobenzidine to determine whether the free amine congeners, their monoacetyl or diacetyl metabolites, or alkaline hydrolyzable conjugates were excreted in the urine. After preliminary tests of the dyes, 2-m...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/7.1.55
更新日期:1983-01-01 00:00:00
abstract::Cotinine biomarker measurements involving both smokers and nonsmokers must accommodate a broad range of concentrations. Thus, we have routinely preclassified unknown samples as being either "high" or "low" by using an enzyme-linked immunoassay for cotinine prior to analysis by tandem mass spectrometry (MS). Although t...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/29.8.814
更新日期:2005-11-01 00:00:00
abstract::An analytical method for determining exposure to 2,2'-dichlorodiethyl sulfide (sulfur mustard, HD) has been enhanced. The method is based on the cleavage of adducted HD (protein-hydroxyethylthioethyl esters) to produce thiodiglycol. Following cleavage, a deuterated internal standard is added, and the analytes are extr...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/32.1.31
更新日期:2008-01-01 00:00:00
abstract::A 5-mg dose of cocaine free base applied to the volar forearm skin surface of a volunteer resulted in a maximal urinary benzoylecgonine concentration of 55 ng/mL at 48 h, using discrete urine specimens. A total of 58 micrograms of benzoylecgonine, representing 1.2% of the dose, was excreted in the 96-h urine. An ident...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/14.6.383
更新日期:1990-11-01 00:00:00
abstract::A method for the determination of the antidepressant drug trazodone is presented. 8-Hydroxyloxapine is used as the internal standard. A simple solid-phase extraction procedure utilizing disposable reversed-phase C18 columns is described. Samples are analyzed by gas chromatography with nitrogen-selective detection usin...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/12.3.150
更新日期:1988-05-01 00:00:00
abstract::A method utilizing microwave dissolution in a closed Teflon bomb followed by hydride generation atomic absorption spectrometry has been used for the routine analysis of arsenic in fish species from the coast of the province of Granada, Spain. The technique was evaluated for decomposing biological standard reference ma...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/16.3.169
更新日期:1992-05-01 00:00:00
abstract::Because mycotoxins occur worldwide in grain and grain products, evaluating their effects on the health of the population has become important. The development of a high performance liquid chromatographic (HPLC) procedure was investigated for the analysis of aflatoxin B1, citrinin, and ochratoxin A, from hydrolyzed hum...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/10.2.41
更新日期:1986-03-01 00:00:00
abstract::Estimating the equivalent whole blood ethanol level from a serum or plasma determination has been addressed by numerous articles in both the clinical and forensic literature. All previous studies have either involved sample sizes insufficient for adequate statistical evaluation or have utilized gas chromatography for ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/31.1.23
更新日期:2007-01-01 00:00:00
abstract::Solid-phase extraction (SPE) and a one-step derivatization are combined with gas chromatography-negative ion chemical ionization-mass spectrometry to simplify a previously reported method for the determination of naltrexone and its metabolite, 6-beta-naltrexol, in human plasma. Deuterated isotopomers of naltrexone and...
journal_title:Journal of analytical toxicology
pub_type: 临床试验,杂志文章
doi:10.1093/jat/21.4.252
更新日期:1997-07-01 00:00:00
abstract::The Rapid Stat assay, a point-of-collection drug-testing device for detection of amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in oral fluid, was evaluated for cannabis and amphetamine-type stimulants. The Rapid Stat tests (n = 134) were applied by police officers in routine traffic chec...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/34.3.155
更新日期:2010-04-01 00:00:00
abstract::Part I. Expert 4: The object of this study was to investigate the applicability of commercially available expert system shells to interpretation in forensic toxicology. Amitriptyline toxicology was selected as a pilot trial. Blood and tissue concentrations of amitriptyline and nortriptyline in fatal and nonfatal amitr...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/12.4.216
更新日期:1988-07-01 00:00:00
abstract::Radioactive methadone, phenytoin, phenobarbital, and diazepam were easily and efficiently removed from human urine samples by adsorption on C18 bonded silica phases. These techniques were simpler than conventional extractions at pH 9.3 or 5.2 with dichloromethane, XAD-2 and methanol, or Celite 560 and dichloromethane....
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/9.6.269
更新日期:1985-11-01 00:00:00