A clinical feature of myocardial stunning associated with acute myocardial infarction.

Abstract:

:We report a case of myocardial stunning after acute myocardial infarction. In the hyperacute phase of myocardial infarction, the patient's coronary arteries showed normal features on coronary angiography during extensive ST-segment elevation observed on a standard 12-lead electrocardiogram and extensive akinesis observed on a left ventriculogram. Thallium-201 emission computed tomography revealed extensive perfusion abnormality. In the chronic phase, the perfusion abnormality was markedly improved. However, the electrocardiogram demonstrated poor R wave progression, and the left ventriculography revealed slight hypokinesis in the anterolateral wall. The acetylcholine provocation test disclosed coronary vasospasm of the left anterior descending coronary artery. About six months thereafter, left ventricular wall motion became completely normal and no poor R wave progression was observed on the electrocardiogram. The findings in this case indicate that myocardial stunning resulted from brief but sever ischemia due to vasospasm which led to cardiogenic shock, and that the recovery of findings for thallium-201 perfusion might be followed by those of electrocardiography and left ventriculography in the stunned myocardium.

journal_name

Ann Nucl Med

authors

Sakata K,Yoshida H,Ono N,Matsunaga Y,Hoshino T,Kaburagi T,Mochizuki M,Yoshimura M

doi

10.1007/BF03165021

subject

Has Abstract

pub_date

1994-05-01 00:00:00

pages

153-7

issue

2

eissn

0914-7187

issn

1864-6433

journal_volume

8

pub_type

杂志文章
  • Scintigraphic changes in bone metastasis from prostate cancer after hormonal therapy--comparison with tumor markers and bone X-ray.

    abstract::Bone scintigraphy is often performed to assess the response to systemic therapy of bone metastasis from prostate cancer. We examined the changes in bone scintigraphic findings and the agreement with AIP, AcP, or other tumor markers measured in the follow-up of patients with known bone metastasis after hormonal therapy...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF03165024

    authors: Koizumi K,Uchiyama G,Komatsu H

    更新日期:1994-11-01 00:00:00

  • In vivo imaging of microglial activation using a peripheral benzodiazepine receptor ligand: [11C]PK-11195 and animal PET following ethanol injury in rat striatum.

    abstract:OBJECTIVE:To investigate whether [(11)C]PK-11195, a specific peripheral benzodiazepine receptors (PBRs) ligand for positron emission tomography (PET), can show activated microglia in a rat brain injury model. METHODS:On day 1, ethanol was injected into the rat's right striatum (ST) using a stereotaxic operative proced...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-008-0136-1

    authors: Toyama H,Hatano K,Suzuki H,Ichise M,Momosaki S,Kudo G,Ito F,Kato T,Yamaguchi H,Katada K,Sawada M,Ito K

    更新日期:2008-06-01 00:00:00

  • Assessment of technetium-99m Technegas scintigraphy for ventilatory impairment in pulmonary emphysema: comparison of planar and SPECT images.

    abstract::Pulmonary emphysema can be diagnosed easily by X-ray CT (CT) as a low attenuation area. Recently Tc-99m-Technegas (Technegas) has been used for ventilation scintigraphy. The present study was undertaken to assess the usefulness of planar and SPECT images by using Technegas scintigraphy in patients with pulmonary emphy...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164818

    authors: Satoh K,Tanabe M,Takahashi K,Kobayashi T,Nishiyama Y,Yamamoto Y,Honjo N,Sasaki M,Ohkawa M,Fujita J,Okada H

    更新日期:1997-05-01 00:00:00

  • Coincidental visualization of an atypical bronchial carcinoid on Tc-99m-sestamibi scan in Kallmann's syndrome.

    abstract::We report a case of an atypical bronchial carcinoid showing sestamibi uptake. A 27-year-old man with Kallmann's syndrome and hyperparathyroidism had parathyroid scintigraphy with 99mTc-sestamibi. A focal uptake was observed on the right perihilar region, and this right perihilar mass was demonstrated on computed tomog...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02995293

    authors: Yapar Z,Kibar M,Sükan A,Paydaş S,Zeren H,Inal M

    更新日期:2002-02-01 00:00:00

  • Assessment of Takotsubo (ampulla) cardiomyopathy using 99mTc-tetrofosmin myocardial SPECT--comparison with acute coronary syndrome.

    abstract:UNLABELLED:We assessed Takotsubo (ampulla) cardiomyopathy compared with acute coronary syndrome (ACS) using two-dimensional echocardiography and 99mTc-tetrofosmin myocardial SPECT. METHODS:We examined 10 patients with Takotsubo cardiomyopathy and 16 with ACS at the time of emergency admission (acute phase), at three t...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02988449

    authors: Ito K,Sugihara H,Katoh S,Azuma A,Nakagawa M

    更新日期:2003-04-01 00:00:00

  • Current status of radioligand therapy and positron-emission tomography with prostate-specific membrane antigen.

    abstract::Prostate-specific membrane antigen (PSMA) is a transmembrane glycoprotein highly expressed by prostate cancer cells. PSMA-based radioligand therapy (RLT) emerged as a promising therapeutic option for prostate cancer in the early 2000s, and has been clinically validated with great enthusiasm during these past two decad...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s12149-020-01549-5

    authors: Inubushi M,Miura H,Kuji I,Ito K,Minamimoto R

    更新日期:2020-12-01 00:00:00

  • Evaluation of a direct 4D reconstruction method using generalised linear least squares for estimating nonlinear micro-parametric maps.

    abstract:OBJECTIVE:Estimation of nonlinear micro-parameters is a computationally demanding and fairly challenging process, since it involves the use of rather slow iterative nonlinear fitting algorithms and it often results in very noisy voxel-wise parametric maps. Direct reconstruction algorithms can provide parametric maps wi...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0881-2

    authors: Angelis GI,Matthews JC,Kotasidis FA,Markiewicz PJ,Lionheart WR,Reader AJ

    更新日期:2014-11-01 00:00:00

  • Investigation of single, random, and true counts from natural radioactivity in LSO-based clinical PET.

    abstract:OBJECTIVE:Lutetium oxyorthosilicate (LSO) contains natural radioactivity that emits beta particles and three gamma photons simultaneously. These beta particles and gamma photons increase the single and random rates in a positron emission tomography (PET) system while a beta particle and gamma photon produced in the sam...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03027389

    authors: Yamamoto S,Horii H,Hurutani M,Matsumoto K,Senda M

    更新日期:2005-04-01 00:00:00

  • High detection sensitivity and reliable morphological correlation of PET with a silicon photomultiplier for primary tongue squamous cell carcinoma.

    abstract:OBJECTIVE:A positron emission tomography (PET) scanner using a silicon photomultiplier (SiPM PET) in place of a photomultiplier tube significantly improves the spatial and time resolution. It may also improve the evaluation of smaller lesions compared to conventional (non-SiPM) PET scanners. We compared the maximum sta...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01489-0

    authors: Kojima I,Takanami K,Ogawa T,Sakamoto M,Nagai H,Miyashita H,Iikubo M

    更新日期:2020-09-01 00:00:00

  • Detection of local recurrence of prostate cancer after radical prostatectomy: Is there a role for early ¹⁸F-FCH PET/CT?

    abstract:AIM:To investigate the diagnostic performance of early acquisition compared to late imaging for the detection of local recurrence of prostate cancer by means of ¹⁸F-FCH PET/CT. MATERIALS AND METHODS:99 patients with radical prostatectomy (mean PSA 3.9 ± 5.03) were subjected to early dynamic PET/CT acquisition of the p...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-015-1015-1

    authors: Di Biagio D,Chiaravalloti A,Tavolozza M,Abbatiello P,Schillaci O

    更新日期:2015-12-01 00:00:00

  • Artificial neural network retrained to detect myocardial ischemia using a Japanese multicenter database.

    abstract:PURPOSE:An artificial neural network (ANN) has been applied to detect myocardial perfusion defects and ischemia. The present study compares the diagnostic accuracy of a more recent ANN version (1.1) with the initial version 1.0. METHODS:We examined 106 patients (age, 77 ± 10 years) with coronary angiographic findings,...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s12149-018-1247-y

    authors: Nakajima K,Okuda K,Watanabe S,Matsuo S,Kinuya S,Toth K,Edenbrandt L

    更新日期:2018-06-01 00:00:00

  • Discontinuation of metformin to prevent metformin-induced high colonic FDG uptake: is 48 h sufficient?

    abstract:OBJECTIVE:In this retrospective, single-center observational study, we investigated whether discontinuing metformin for at least 48 h prevents metformin-induced [18F]fluorodeoxyglucose (FDG) uptake in all segments of the colon. METHODS:Patients with type 2 diabetes who were using metformin before undergoing an FDG PET...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01509-z

    authors: Schreuder N,Klarenbeek H,Vendel BN,Jager PL,Kosterink JGW,van Puijenbroek EP

    更新日期:2020-11-01 00:00:00

  • Left ventricular systolic/diastolic function evaluated by quantitative ECG-gated SPECT: comparison with echocardiography and plasma BNP analysis.

    abstract:OBJECTIVE:The aim of this study was to evaluate the left ventricular (LV) functional parameters calculated using quantitative electrocardiography (ECG)-gated myocardial perfusion single photon emission computed tomography (QGS). In addition to LV systolic parameters, diastolic parameters were compared with those by ult...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02985571

    authors: Nakae I,Matsuo S,Koh T,Mitsunami K,Horie M

    更新日期:2005-09-01 00:00:00

  • Uptake of pentavalent technetium-99m dimercaptosuccinic acid in idiopathic synovial chondromatosis.

    abstract::We reported two Tc-99m(V) DMSA scintigrams in patients with idiopathic synovial chondromatosis which affected the metacarpo-phalangeal joint and shoulder joint. Tc-99m(V) DMSA accumulated markedly and diffusely in the tumor. Tc-99m(V) DMSA scintigraphy would be valuable for deciding the optimal site for biopsy. ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03165044

    authors: Kobayashi H,Kotoura Y,Hosono M,Tsuboyama T,Nishijima N,Sakahara H,Konishi J

    更新日期:1995-08-01 00:00:00

  • The management of pyothorax-associated lymphoma using 18F-FDG PET/CT.

    abstract:OBJECTIVE:Pyothorax-associated lymphoma (PAL) is a rare form of lymphoma and its management on (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) combined computed tomography (CT) has not been well reported. The purpose of this study was to evaluate the usefulness of FDG PET/CT in patients with PAL. MAT...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-010-0408-4

    authors: Ito K,Shida Y,Kubota K,Morooka M,Aruga T,Itami J,Matsuda H

    更新日期:2010-11-01 00:00:00

  • An assessment of bone-seeking radionuclides for palliation of metastatic bone pain in a vertebral model.

    abstract:OBJECTIVE:Bone-seeking radiopharmaceuticals have the main role in the treatment of painful bone metastases. The aim of this study was to dosimetrically compare radiopharmaceuticals in use for bone pain palliation therapy and bone scan. METHODS:The MCNPX code was used to simulate the radiation transport in a vertebral ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-019-01329-w

    authors: Sadremomtaz A,Masoumi M

    更新日期:2019-04-01 00:00:00

  • Usefulness of [18F]FDG-PET kinetic analysis in non-enhancing primary central nervous system lymphoma: case report.

    abstract::A 62-year-old woman experienced headache and rapidly progressive left hemiparesis over 2 weeks. Diffusion-weighted and fluid-attenuated inversion recovery MR images of the head showed increased signal intensity in the right basal ganglia, periventricular white matter and the brain stem. Enhancement was not observed on...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03027408

    authors: Kawai N,Kawanishi M,Tamiya T,Nagao S

    更新日期:2005-07-01 00:00:00

  • Correction of scattered photons in Tc-99m imaging by means of a photopeak dual-energy window acquisition.

    abstract::We are proposing a new method for correcting of scattered photons in technetium-99m (99mTc) imaging by means of photopeak dual-energy window acquisition. This method consists of the simultaneous acquisition of two images and estimation of a scatter image included in the symmetric energy window (SW) image by the differ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178307

    authors: Kojima A,Tsuji A,Takaki Y,Tomiguchi S,Hara M,Matsumoto M,Takahashi M

    更新日期:1992-08-01 00:00:00

  • Coronary flow reserve and relative flow reserve measured by N-13 ammonia PET for characterization of coronary artery disease.

    abstract:OBJECTIVE:We evaluated the relationships between coronary flow reserve (CFR) and relative flow reserve (RFR) measured by N-13 ammonia positron emission tomography (PET) for characterization of epicardial coronary artery disease (CAD). METHODS:Sixty-nine consecutive stable angina patients underwent N-13 ammonia PET, co...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-016-1138-z

    authors: Cho SG,Park KS,Kim J,Kang SR,Song HC,Kim JH,Cho JY,Hong YJ,Jabin Z,Park HJ,Jeong GC,Kwon SY,Paeng JC,Kim HS,Min JJ,Garcia EV,Bom HH

    更新日期:2017-02-01 00:00:00

  • High-dose 131I-metaiodobenzylguanidine therapy in patients with high-risk neuroblastoma in Japan.

    abstract:OBJECTIVE:The aim of the study was to investigate the outcomes and prognostic factors of high-dose 131I-metaiodobenzylguanidine (131I-MIBG) therapy in patients with refractory or relapsed neuroblastoma (NBL) in Japan. METHODS:We retrospectively analyzed 20 patients with refractory or relapsed high-risk NBL who underwe...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01460-z

    authors: Kayano D,Wakabayashi H,Nakajima K,Kuroda R,Watanabe S,Inaki A,Toratani A,Akatani N,Yamase T,Kunita Y,Hiromasa T,Takata A,Mori H,Saito S,Araki R,Taki J,Kinuya S

    更新日期:2020-06-01 00:00:00

  • Single photon emission computed tomography with Tc-99m-dimercaptosuccinic acid in patients with upper urinary tract infection and/or vesicoureteral reflux.

    abstract::By means of Tc-99m dimercaptosuccinic acid (DMSA) scintigraphy, an established method for assessing renal cortical damage, we evaluated the pick-up rate for renal defects (scars) by single photon computed tomography (SPECT) and planar images of 10 normal volunteers, and 58 patients (70 scintigrams) with upper urinary ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164610

    authors: Itoh K,Asano Y,Tsukamoto E,Kato C,Nakada K,Nagao K,Furudate M,Gotoh T,Nonomura K,Koyanagi T

    更新日期:1991-03-01 00:00:00

  • Intravascular large B-cell lymphoma with diffuse FDG uptake in the lung by 18FDG-PET/CT without chest CT findings.

    abstract::We report a rare case of intravascular large B-cell lymphoma (IVLBCL) with diffuse fluorodeoxyglucose (FDG) uptake in the lung by (18)FDG-positron emission tomography/computed tomography (PET/CT). CT showed nodular shadow, whereas diffuse FDG uptake in PET/CT suggested IVLBCL in the lung. A random skin biopsy provided...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-012-0600-9

    authors: Yamashita H,Suzuki A,Takahashi Y,Kubota K,Kano T,Mimori A

    更新日期:2012-07-01 00:00:00

  • Semiquantitative analysis of C-11 methionine PET may distinguish brain tumor recurrence from radiation necrosis even in small lesions.

    abstract:OBJECTIVE:(11)C-Methionine positron emission tomography (MET-PET) has been used to distinguish brain tumor recurrence from radiation necrosis. Because the spatial resolution of conventional PET scanners is low, partial volume effect (PVE) may decrease the detectability of small tumor recurrence. The aim of this study i...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-010-0450-2

    authors: Okamoto S,Shiga T,Hattori N,Kubo N,Takei T,Katoh N,Sawamura Y,Nishijima K,Kuge Y,Tamaki N

    更新日期:2011-04-01 00:00:00

  • Impact of CT attenuation correction by SPECT/CT in brain perfusion images.

    abstract:PURPOSE:The aim of this study was to elucidate the regional differences between brain perfusion single photon emission computed tomography (SPECT) images reconstructed with a uniform attenuation correction using Chang's method (AC-Chang) and a non-uniform attenuation correction with CT using SPECT/CT (AC-CT). METHODS:...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-011-0567-y

    authors: Ishii K,Hanaoka K,Okada M,Kumano S,Komeya Y,Tsuchiya N,Hosono M,Murakami T

    更新日期:2012-04-01 00:00:00

  • (99m)Tc-DTPA dynamic SPECT and CT volumetry for measuring split renal function in live kidney donors.

    abstract:OBJECTIVES:Split renal function (SRF) estimated from the posterior view of (99m)Tc-diethylenetriaminepentaacetic acid planar scintigraphy (DTPA/P) is not sufficiently accurate even after correction for kidney depth by computed tomography (CT). To obtain more accurate SRF using (99m)Tc-DTPA, dynamic SPECT method was car...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-010-0349-y

    authors: Miyazaki C,Harada H,Shuke N,Okizaki A,Miura M,Hirano T

    更新日期:2010-04-01 00:00:00

  • Radioactive synthesis of tau PET imaging agent 18F-AV-1451 and its role in monitoring the progression of Alzheimer's disease and supporting differential diagnosis.

    abstract::Alzheimer's disease (AD) is on the rise all over the world, and brings with it great challenges to medical care and heavy burdens to family and society. Accurate diagnosis and differential diagnosis are of great importance. Tau positron emission tomography (PET) might offer novel insights and be of great assistance in...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s12149-020-01566-4

    authors: Zhang W,Xu S,Yu H,Li X,Jin Z,Li Y,He Z

    更新日期:2021-01-18 00:00:00

  • Quantitative analysis of myocardial ischemia by technetium-99m sestamibi exercise scintigraphy: a new method for change rate mapping.

    abstract::In order to quantitatively assess the extent and severity of myocardial ischemia by Tc-99m sestamibi exercise myocardial scintigraphy, we developed a new method of change rate (CR) mapping and examined its efficiency. CR was calculated to divide the counts per pixel in the stress polar map by that in the rest polar ma...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03165306

    authors: Nakata S,Higashino H,Kuwahara T,Tanada S,Hamamoto K

    更新日期:1997-11-01 00:00:00

  • Assessment of myocardial viability in patients with myocardial infarction using twenty-four hour thallium-201 late redistribution imaging.

    abstract:BACKGROUND:Rest thallium-201 (201Tl) myocardial perfusion imaging has been widely used for evaluation of myocardial ischemia/viability after myocardial infarction, but the ideal timing for imaging after injection to maximally estimate viability is not well established. METHODS:Thirty-six patients with myocardial infar...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02985586

    authors: Yang XJ,He YM,Zhang B,Wu YW,Hui J,Jiang TB,Song JP,Liu ZH,Jiang WP

    更新日期:2006-01-01 00:00:00

  • Extrarenal uptake of Tc-99m-DTPA in a case of retroperitoneal abscess causing spurious data in renal function assessment.

    abstract::The author reports CT of the abdomen and quantitative analysis of renal scintigraphy that was spuriously assessed due to unwanted extrarenal uptake. The patient had a retroperitoneal abscess that was related to fistula from the right kidney. Renal scintigraphy was performed to assess split renal function as a preopera...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164784

    authors: Choe W

    更新日期:1998-06-01 00:00:00

  • Prognostic role of pretreatment 18F-FDG PET/CT in primary brain lymphoma.

    abstract:OBJECTIVE:Primary brain lymphoma is an aggressive extranodal non-Hodgkin lymphoma with poor prognosis. Many possible prognostic factors are investigated with controversial results, but possible prognostic role of 18fluorine-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) features re...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-018-1274-8

    authors: Albano D,Bertoli M,Battistotti M,Rodella C,Statuto M,Giubbini R,Bertagna F

    更新日期:2018-10-01 00:00:00