Assessment of technetium-99m Technegas scintigraphy for ventilatory impairment in pulmonary emphysema: comparison of planar and SPECT images.

Abstract:

:Pulmonary emphysema can be diagnosed easily by X-ray CT (CT) as a low attenuation area. Recently Tc-99m-Technegas (Technegas) has been used for ventilation scintigraphy. The present study was undertaken to assess the usefulness of planar and SPECT images by using Technegas scintigraphy in patients with pulmonary emphysema. Technegas scintigraphy, CT and pulmonary function tests were performed in 20 patients (males, age 32-78 years). We classified the findings of Technegas images into 4 grades. Comparing planar and SPECT images of Technegas, more detailed findings were shown by SPECT than by planar images in mild cases (6 cases, 30%). In more severe cases, findings of SPECT and planar images were equivalent (14 cases, 70%). The degree of abnormal findings obtained by SPECT was equivalent to that obtained by CT in severe cases (6 cases, 30%). SPECT should be excluded in advanced stages as indicated by planar images.

journal_name

Ann Nucl Med

authors

Satoh K,Tanabe M,Takahashi K,Kobayashi T,Nishiyama Y,Yamamoto Y,Honjo N,Sasaki M,Ohkawa M,Fujita J,Okada H

doi

10.1007/BF03164818

subject

Has Abstract

pub_date

1997-05-01 00:00:00

pages

109-13

issue

2

eissn

0914-7187

issn

1864-6433

journal_volume

11

pub_type

杂志文章
  • Shortened protocol in practical [11C]SA4503-PET studies for sigma1 receptor quantification.

    abstract::In practical positron emission tomography (PET) diagnosis, a shortened protocol is preferred for patients with brain disorders. In this study, the applicability of a shortened protocol as an alternative to the 90-min PET scan with [(11)C]SA4503 for quantitative sigma(1) receptor measurement was investigated. Tissue ti...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-007-0088-x

    authors: Sakata M,Kimura Y,Naganawa M,Ishikawa M,Oda K,Ishii K,Hashimoto K,Chihara K,Ishiwata K

    更新日期:2008-02-01 00:00:00

  • A preliminary report of breast cancer screening by positron emission mammography.

    abstract:OBJECTIVE:Fluorine-18 fluorodeoxyglucose (FDG)-positron emission tomography (PET) and PET/computed tomography (PET/CT) have had a considerable impact on the detection of various malignancies. PET and PET/CT are minimally invasive methods that can provide whole-body imaging at one time. Therefore, an FDG-PET cancer scre...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-015-1040-0

    authors: Yamamoto Y,Tasaki Y,Kuwada Y,Ozawa Y,Inoue T

    更新日期:2016-02-01 00:00:00

  • Assessment of liver function in chronic liver diseases and regional function of irradiated liver by means of 99mTc-galactosyl-human serum albumin liver scintigraphy and quantitative spectral analysis.

    abstract::Scintigraphy with 99mTc-diethylenetriamine pentaacetic acid galactosyl human serum albumin (99mTc-GSA) was performed on 102 patients, then the hepatic extraction fraction (HEF), the rate constant for liver uptake of the tracer from the blood (K1) and the hepatic blood flow index (HBFI) were determined by spectral anal...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02988293

    authors: Fukui A,Murase K,Tsuda T,Fujii T,Ikezoe J

    更新日期:2000-12-01 00:00:00

  • Performance of (18)F-FDG PET/CT as a postoperative surveillance imaging modality for asymptomatic advanced gastric cancer patients.

    abstract:OBJECTIVE:The purpose of this study was to investigate the diagnostic performance of postoperative fluorine-18 fluoro-2-deoxy-D-glucose ((18)F-FDG) positron emission tomography/computed tomography (PET/CT) as a surveillance modality for advanced gastric cancer patients who were asymptomatic and negative by conventional...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0871-4

    authors: Lee DY,Lee CH,Seo MJ,Lee SH,Ryu JS,Lee JJ

    更新日期:2014-10-01 00:00:00

  • Comparison of subareolar injection lymphoscintigraphy with the 1-day and the 2-day protocols for the detection of sentinel lymph nodes in patients with breast cancer.

    abstract:OBJECTIVE:Lymphoscintigraphy and sentinel node biopsy are used for the detection of axillary lymph node metastasis in breast cancer patients. However, currently there is no standardized technique. For the detection of axillary lymph node metastasis by lymphoscintigraphy and sentinel node biopsy, in patients with breast...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-009-0259-z

    authors: Seok JW,Kim IJ,Heo YJ,Yang YJ,Choi YS,Kim BG,Park SJ

    更新日期:2009-07-01 00:00:00

  • Luxury perfusion phenomenon in acute herpes simplex virus encephalitis.

    abstract::In a patient with acute herpes simplex virus (HSV) encephalitis, positron emission tomography (PET) demonstrated increased cerebral blood flow in the affected temporal lobe accompanied by reduction in the cerebral oxygen extraction fraction and the cerebral metabolic rate of oxygen, i.e., luxury perfusion. Follow-up P...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03165008

    authors: Tanaka M,Uesugi M,Igeta Y,Kondo S,Sun X,Hirai S

    更新日期:1995-02-01 00:00:00

  • Association of tau accumulation and atrophy in mild cognitive impairment: a longitudinal study.

    abstract:OBJECTIVE:To examine the patterns of longitudinal tau accumulation and cortical atrophy and their association in subjects with mild cognitive impairment (MCI). METHODS:We collected 23 participants (60-89 years old, 11 males/12 females) with MCI from the Alzheimer's Disease Neuroimaging Initiative database. All partici...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01506-2

    authors: Xu G,Zheng S,Zhu Z,Yu X,Jiang J,Jiang J,Chu Z,Alzheimer’s Disease Neuroimaging Initiative.

    更新日期:2020-11-01 00:00:00

  • Single photon emission computed tomography with Tc-99m-dimercaptosuccinic acid in patients with upper urinary tract infection and/or vesicoureteral reflux.

    abstract::By means of Tc-99m dimercaptosuccinic acid (DMSA) scintigraphy, an established method for assessing renal cortical damage, we evaluated the pick-up rate for renal defects (scars) by single photon computed tomography (SPECT) and planar images of 10 normal volunteers, and 58 patients (70 scintigrams) with upper urinary ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164610

    authors: Itoh K,Asano Y,Tsukamoto E,Kato C,Nakada K,Nagao K,Furudate M,Gotoh T,Nonomura K,Koyanagi T

    更新日期:1991-03-01 00:00:00

  • Pathophysiology and diagnosis of hibernating myocardium in patients with post-ischemic heart failure: the contribution of PET.

    abstract::Identification and treatment of hibernating myocardium (HM) lead to improvement in LV function and prognosis in patients with post-ischemic heart failure. Different techniques are used to diagnose HM: echocardiography, MRI, SPECT and PET and, in patients with moderate LV impairment, their predictive values are similar...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/BF03006599

    authors: Camici PG,Rimoldi OE

    更新日期:2003-07-01 00:00:00

  • Imaging of adenosine A1 receptors in the human brain by positron emission tomography with [11C]MPDX.

    abstract::We report the first clinical PET study using [1-methyl-11C]8-dicyclopropylmethyl-1-methyl-3-propylxanthine ([11C]MPDX) for imaging adenosine A1 receptors in the human brain. The binding of [11C]MPDX evaluated quantitatively as the distribution volume by a graphical analysis was high in the striatum and thalamus, and l...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF03006445

    authors: Fukumitsu N,Ishii K,Kimura Y,Oda K,Sasaki T,Mori Y,Ishiwata K

    更新日期:2003-09-01 00:00:00

  • Artificial neural network retrained to detect myocardial ischemia using a Japanese multicenter database.

    abstract:PURPOSE:An artificial neural network (ANN) has been applied to detect myocardial perfusion defects and ischemia. The present study compares the diagnostic accuracy of a more recent ANN version (1.1) with the initial version 1.0. METHODS:We examined 106 patients (age, 77 ± 10 years) with coronary angiographic findings,...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s12149-018-1247-y

    authors: Nakajima K,Okuda K,Watanabe S,Matsuo S,Kinuya S,Toth K,Edenbrandt L

    更新日期:2018-06-01 00:00:00

  • An enhanced treatment effect can be expected from a higher serum thyroglobulin level after radioactive iodine therapy.

    abstract:OBJECTIVE:The aim of this study was to investigate if increased serum thyroglobulin (Tg) levels after radioactive iodine (RAI) showed more therapeutic effects in patients with differentiated thyroid cancer (DTC). METHODS:Data of 65 patients with DTC who underwent RAI from June 2014 to September 2016 were reviewed. Ser...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-018-1313-5

    authors: Choi JH,Lim I,Lee I,Byun BH,Kim BI,Choi CW,Lim SM

    更新日期:2019-02-01 00:00:00

  • Derivation of attenuation map for attenuation correction of PET data in the presence of nanoparticulate contrast agents using spectral CT imaging.

    abstract:OBJECTIVE:Uptake value in quantitative PET imaging is biased due to the presence of CT contrast agents when using CT-based attenuation correction. Our aim was to examine spectral CT imaging to suppress inaccuracy of 511 keV attenuation map in the presence of multiple nanoparticulate contrast agents. METHODS:Using a si...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0846-5

    authors: Ghadiri H,Shiran MB,Soltanian-Zadeh H,Rahmim A,Zaidi H,Ay MR

    更新日期:2014-07-01 00:00:00

  • Computer-aided diagnosis system for bone scintigrams from Japanese patients: importance of training database.

    abstract:AIM:Computer-aided diagnosis (CAD) software for bone scintigrams have recently been introduced as a clinical quality assurance tool. The purpose of this study was to compare the diagnostic accuracy of two CAD systems, one based on a European and one on a Japanese training database, in a group of bone scans from Japanes...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-012-0620-5

    authors: Horikoshi H,Kikuchi A,Onoguchi M,Sjöstrand K,Edenbrandt L

    更新日期:2012-10-01 00:00:00

  • Prognostic role of pretreatment 18F-FDG PET/CT in primary brain lymphoma.

    abstract:OBJECTIVE:Primary brain lymphoma is an aggressive extranodal non-Hodgkin lymphoma with poor prognosis. Many possible prognostic factors are investigated with controversial results, but possible prognostic role of 18fluorine-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) features re...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-018-1274-8

    authors: Albano D,Bertoli M,Battistotti M,Rodella C,Statuto M,Giubbini R,Bertagna F

    更新日期:2018-10-01 00:00:00

  • Surveillance study for creating the national clinical database related to ECG-gated myocardial perfusion SPECT of ischemic heart disease: J-ACCESS study design.

    abstract:BACKGROUND:ECG-gated myocardial perfusion SPECT is widely applied to diagnose ischemic heart disease, and such findings are useful to predict patient prognosis. However, Japan does not have a database that correlates SPECT image findings with the prognosis of patients who have ischemic heart disease. METHODS:A large-s...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1007/BF03027430

    authors: Kusuoka H,Nishimura S,Yamashina A,Nakajima K,Nishimura T

    更新日期:2006-04-01 00:00:00

  • Comparison of FDG-PET, MRI and CT for post radiofrequency ablation evaluation of hepatic tumors.

    abstract:PURPOSE:Treatment effect of radiofrequency ablation (RFA) is traditionally accomplished with MRI and/or CT. The aim of the study was to assess the role of FDG-PET in post RFA hepatic tumor evaluation, in comparison with MRI and CT. MATERIALS AND METHODS:28 patients (33 hepatic RFA lesions) who had post RFA FDG-PET wit...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-012-0656-6

    authors: Chen W,Zhuang H,Cheng G,Torigian DA,Alavi A

    更新日期:2013-01-01 00:00:00

  • Usefulness of the Chang attenuation correction method with use of a CT-based μ map by FBP reconstruction in (201)Tl SPECT-MPI.

    abstract:OBJECTIVE:Attenuation correction (AC) on nuclear images of non-uniform domains is generally performed by a change of the computed tomography (CT) values to μ values, which are then inserted as components into the detection probability of iterative reconstruction techniques (OS-EM Iterative AC). We established an AC tec...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-015-0972-8

    authors: Nakamura Y,Tomiguchi S

    更新日期:2015-06-01 00:00:00

  • 18F-FDG and 11C-choline uptake in proliferating tumor cells is dependent on the cell cycle in vitro.

    abstract:OBJECTIVE:Among different PET tracers, 18F-fludeoxyglucose (FDG) and 11C-choline are known to have a high tumor uptake correlated with a high mitotic index of tumor cells. Thus, the uptake of 18F-FDG and 11C-choline may be dependent on the cell cycle. In the present study, we examined the uptake of 18F-FDG and 11C-chol...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-018-01325-6

    authors: Roppongi M,Izumisawa M,Terasaki K,Muraki Y,Shozushima M

    更新日期:2019-04-01 00:00:00

  • Bremsstrahlung parameters of praseodymium-142 in different human tissues: a dosimetric perspective for (142)Pr radionuclide therapy.

    abstract:OBJECTIVE:Praseodymium-142 [T 1/2 = 19.12 h, [Formula: see text] = 2.162 MeV (96.3%), Eγ = 1575 keV (3.7%)] is one of the (141)Pr radioisotopes. Many studies have been attempted to assess the significance of usage (142)Pr in radionuclide therapy. In many studies, the dosimetric parameters of (142)Pr sources were calcul...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-012-0591-6

    authors: Bakht MK,Jabal-Ameli H,Ahmadi SJ,Sadeghi M,Sadjadi S,Tenreiro C

    更新日期:2012-06-01 00:00:00

  • Radius dependence of FP-CIT quantification: a Monte Carlo-based simulation study.

    abstract:OBJECTIVE:Dopamine transporter imaging with SPECT is a valuable tool for both clinical routine and research studies. Semi-quantitative analysis plays a key role in interpreting the scans, but is dependent on numerous factors, rotational radius being one of them. This study systematically evaluates the potential influen...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-013-0789-2

    authors: Koch W,Bartenstein P,la Fougère C

    更新日期:2014-02-01 00:00:00

  • A large renal pelvic diverticulum, presenting incomplete excretion during tc-99m MAG-3 scintigraphy and tracer accumulation on tc-99m DMSA scintigraphy; a case report.

    abstract::This case report illustrates the dynamic and static renal scintigraphic images of a patient with an unusual large diverticulum of the renal pelvis. The initial diagnosis by intravenous pyelography (IVP) and ultrasonographic (US) examination was a renal pelvic diverticulum of the left kidney, and the patient was referr...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02985963

    authors: Turgut B,Erselcan T,Ozdemir S,Hasbek Z,Tosun HB,Topaktas S

    更新日期:2004-12-01 00:00:00

  • Attenuation correction using combination of a parallel hole collimator and an uncollimated non-uniform line array source.

    abstract::Attenuation correction is very important for quantitative SPECT imaging. We designed an uncollimated non-uniform line array source (non-uniform LAS) for attenuation correction based on transmission computed tomography (TCT) using Tc-99m and compared its performance with an uncollimated uniform line array source (unifo...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02984481

    authors: Kojima A,Kawanaka K,Nakaura T,Shiraishi S,Utsunomiya D,Katsuda N,Tomiguchi S,Yamashita Y,Matsumoto M,Motomura N,Ichihara T

    更新日期:2004-07-01 00:00:00

  • Technetium-99m tetrofosmin uptake in lung cancer: comparison with thallium-201.

    abstract::Technetium-99m tetrofosmin and thallium-201 lung SPECT imaging were performed in a patient with adenocarcinoma of the lung. Significant activities in the lung lesion were clearly depicted on both technetium-99m tetrofosmin and thallium-201 SPECT imaging. The early uptake, delayed uptake ratios and retention indices of...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03165069

    authors: Matsunari I,Kinuya S,Nishikawa T,Matoba M,Murakita K,Ohguchi M,Ichiyanagi K,Taki J,Tonami N,Hisada K

    更新日期:1996-02-01 00:00:00

  • The role of positron emission tomography using carbon-11 and fluorine-18 choline in tumors other than prostate cancer: a systematic review.

    abstract::To systematically review published data on the role of positron emission tomography (PET) or PET/computed tomography (PET/CT) using either Carbon-11 ((11)C) or Fluorine-18 ((18)F) choline tracer in tumors other than prostatic cancer. A comprehensive literature search of studies published in PubMed/MEDLINE and Embase d...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s12149-012-0602-7

    authors: Treglia G,Giovannini E,Di Franco D,Calcagni ML,Rufini V,Picchio M,Giordano A

    更新日期:2012-07-01 00:00:00

  • Development of Convolutional Neural Networks to identify bone metastasis for prostate cancer patients in bone scintigraphy.

    abstract:OBJECTIVE:The main aim of this work is to build a robust Convolutional Neural Network (CNN) algorithm that efficiently and quickly classifies bone scintigraphy images, by determining the presence or absence of prostate cancer metastasis. METHODS:CNN, widely applied in medical image classification, was used for bone sc...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01510-6

    authors: Papandrianos N,Papageorgiou EI,Anagnostis A

    更新日期:2020-11-01 00:00:00

  • A clinical feature of myocardial stunning associated with acute myocardial infarction.

    abstract::We report a case of myocardial stunning after acute myocardial infarction. In the hyperacute phase of myocardial infarction, the patient's coronary arteries showed normal features on coronary angiography during extensive ST-segment elevation observed on a standard 12-lead electrocardiogram and extensive akinesis obser...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03165021

    authors: Sakata K,Yoshida H,Ono N,Matsunaga Y,Hoshino T,Kaburagi T,Mochizuki M,Yoshimura M

    更新日期:1994-05-01 00:00:00

  • Automatic lung segmentation in functional SPECT images using active shape models trained on reference lung shapes from CT.

    abstract:OBJECTIVE:Image segmentation is an essential step in quantifying the extent of reduced or absent lung function. The aim of this study is to develop and validate a new tool for automatic segmentation of lungs in ventilation and perfusion SPECT images and compare automatic and manual SPECT lung segmentations with referen...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-017-1223-y

    authors: Cheimariotis GA,Al-Mashat M,Haris K,Aletras AH,Jögi J,Bajc M,Maglaveras N,Heiberg E

    更新日期:2018-02-01 00:00:00

  • Measurement of cerebral blood flow by the autoradiographic method with N-isopropyl-4-[I-123] iodoamphetamine: comparison of radiopharmaceuticals marketed by different companies in Japan.

    abstract:OBJECTIVE:Iodine-123-labeled N-isopropyl-4-iodoamphetamine (IMP) is used as a tracer for the measurement of cerebral blood flow (CBF) by single-photon emission computed tomography (SPECT). Two IMP products, IMP(A) (Nihon Medi-Physics Co., Ltd.) and IMP(B) (FUJIFILM RI Pharma Co., Ltd.), produced by different radiopharm...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-009-0242-8

    authors: Ogura T,Ito H,Hida K,Masuzuka T,Fukuda H,Hatazawa J

    更新日期:2009-06-01 00:00:00

  • A 3-variable prognostic score (3-PS) for overall survival prediction in metastatic castration-resistant prostate cancer treated with 223Radium-dichloride.

    abstract:OBJECTIVE:In mCRPC patients treated with 223Ra, a major issue is the validation of reliable prognostic and predictive biomarkers to maximize clinical benefit and minimize toxicities and costs. Bearing in mind how changes in tALP did not meet statistical requirements as surrogate marker for survival, aim of this single-...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-017-1228-6

    authors: Frantellizzi V,Farcomeni A,Follacchio GA,Pacilio M,Pellegrini R,Pani R,De Vincentis G

    更新日期:2018-02-01 00:00:00