Automatic lung segmentation in functional SPECT images using active shape models trained on reference lung shapes from CT.

Abstract:

OBJECTIVE:Image segmentation is an essential step in quantifying the extent of reduced or absent lung function. The aim of this study is to develop and validate a new tool for automatic segmentation of lungs in ventilation and perfusion SPECT images and compare automatic and manual SPECT lung segmentations with reference computed tomography (CT) volumes. METHODS:A total of 77 subjects (69 patients with obstructive lung disease, and 8 subjects without apparent perfusion of ventilation loss) performed low-dose CT followed by ventilation/perfusion (V/P) SPECT examination in a hybrid gamma camera system. In the training phase, lung shapes from the 57 anatomical low-dose CT images were used to construct two active shape models (right lung and left lung) which were then used for image segmentation. The algorithm was validated in 20 patients, comparing its results to reference delineation of corresponding CT images, and by comparing automatic segmentation to manual delineations in SPECT images. RESULTS:The Dice coefficient between automatic SPECT delineations and manual SPECT delineations were 0.83 ± 0.04% for the right and 0.82 ± 0.05% for the left lung. There was statistically significant difference between reference volumes from CT and automatic delineations for the right (R = 0.53, p = 0.02) and left lung (R = 0.69, p < 0.001) in SPECT. There were similar observations when comparing reference volumes from CT and manual delineations in SPECT images, left lung (bias was - 10 ± 491, R = 0.60, p = 0.005) right lung (bias 36 ± 524 ml, R = 0.62, p = 0.004). CONCLUSION:Automated segmentation on SPECT images are on par with manual segmentation on SPECT images. Relative large volumetric differences between manual delineations of functional SPECT images and anatomical CT images confirms that lung segmentation of functional SPECT images is a challenging task. The current algorithm is a first step towards automatic quantification of wide range of measurements.

journal_name

Ann Nucl Med

authors

Cheimariotis GA,Al-Mashat M,Haris K,Aletras AH,Jögi J,Bajc M,Maglaveras N,Heiberg E

doi

10.1007/s12149-017-1223-y

subject

Has Abstract

pub_date

2018-02-01 00:00:00

pages

94-104

issue

2

eissn

0914-7187

issn

1864-6433

pii

10.1007/s12149-017-1223-y

journal_volume

32

pub_type

杂志文章
  • Uptake and washout of I-123-MIBG in neuronal and non-neuronal sites in rat hearts: relationship to renal clearance.

    abstract::We investigated the uptake and washout of I-123-metaiodobenzylguanidine (MIBG) in neuronal (both intra- and extravesicular) and non-neuronal sites in the heart and its relationship to renal clearance. Acute renal failure was induced in rats by ligating the renal vessels, and the findings were compared with those of sh...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03165394

    authors: Arbab AS,Koizumi K,Araki T

    更新日期:1996-05-01 00:00:00

  • Normal values for nuclear cardiology: Japanese databases for myocardial perfusion, fatty acid and sympathetic imaging and left ventricular function.

    abstract::Myocardial normal databases for stress myocardial perfusion study have been created by the Japanese Society of Nuclear Medicine Working Group. The databases comprised gender-, camera rotation range- and radiopharmaceutical-specific data-sets from multiple institutions, and normal database files were created for instal...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s12149-009-0337-2

    authors: Nakajima K

    更新日期:2010-04-01 00:00:00

  • Usefulness of the Chang attenuation correction method with use of a CT-based μ map by FBP reconstruction in (201)Tl SPECT-MPI.

    abstract:OBJECTIVE:Attenuation correction (AC) on nuclear images of non-uniform domains is generally performed by a change of the computed tomography (CT) values to μ values, which are then inserted as components into the detection probability of iterative reconstruction techniques (OS-EM Iterative AC). We established an AC tec...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-015-0972-8

    authors: Nakamura Y,Tomiguchi S

    更新日期:2015-06-01 00:00:00

  • Efficacy of conventional whole-body ¹⁸F-FDG PET/CT in the incidental findings of parotid masses.

    abstract:OBJECTIVE:The objective of this study was to evaluate the incidence of incidental parotid masses with conventional whole-body ¹⁸F-deoxyglucose (FDG) PET/CT and assess the ability of PET/CT to characterize these unexpected parotid lesions. METHODS:Fifty eight incidental findings of parotid masses with routine FDG PET/C...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-010-0394-6

    authors: Wang HC,Zuo CT,Hua FC,Huang ZM,Tan HB,Zhao J,Guan YH

    更新日期:2010-10-01 00:00:00

  • Oncologic significance of unexpected osseous foci on FDG-PET without correlative CT abnormalities.

    abstract:PURPOSE:Our purpose was to explore the clinical significance of unexpected osseous foci on 18F-FDG-PET without correlative CT abnormalities (FWCT) in patients referred for oncologic evaluation. The significance of FDG-avid foci without correlative CT abnormalities has been previously explored in tissues such as breast,...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01572-6

    authors: Zamora E,Valdivia AY

    更新日期:2021-01-13 00:00:00

  • Relationship between bone scintigraphy and tumor markers in patients with breast cancer.

    abstract:PURPOSE:The aim of this study is to specify the precise role of bone scintigraphy and serum CEA and CA 15-3 assays in the monitoring of breast cancers in order to optimize their use and to determine whether it is possible to guide the prescription of bone scan by the use of CEA and CA 15-3 assays in the monitoring of b...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02984567

    authors: Yildiz M,Oral B,Bozkurt M,Cobaner A

    更新日期:2004-09-01 00:00:00

  • Reducing renal uptake of 111In-DOTATOC: a comparison among various basic amino acids.

    abstract:PURPOSE:Several studies have reported significant renal toxicity after the use of a high dose of 90Y-DOTATOC. Thus, renal protection is necessary in treatments with 90Y-DOTA Tyr3-octreotide (DOTATOC). The infusion of certain positively charged amino acids has been shown to effectively reduce renal uptake of DOTATOC. In...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03034003

    authors: Lin YC,Hung GU,Luo TY,Tsai SC,Sun SS,Hsia CC,Chen SL,Lin WY

    更新日期:2007-01-01 00:00:00

  • Brown adipose tissue demonstrating intense FDG uptake in a patient with mediastinal pheochromocytoma.

    abstract::We present an interesting case with a central mediastinal pheochromocytoma showing intense F-18 fluorodeoxyglucose (FDG) uptake in tumor and systemic brown adipose tissue (BAT) mimicking metastases. The findings of hypertension and high plasma catecholamine concentration suggested the presence of pheochromocytoma. Med...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-007-0096-x

    authors: Kuji I,Imabayashi E,Minagawa A,Matsuda H,Miyauchi T

    更新日期:2008-04-01 00:00:00

  • Coronary flow reserve and relative flow reserve measured by N-13 ammonia PET for characterization of coronary artery disease.

    abstract:OBJECTIVE:We evaluated the relationships between coronary flow reserve (CFR) and relative flow reserve (RFR) measured by N-13 ammonia positron emission tomography (PET) for characterization of epicardial coronary artery disease (CAD). METHODS:Sixty-nine consecutive stable angina patients underwent N-13 ammonia PET, co...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-016-1138-z

    authors: Cho SG,Park KS,Kim J,Kang SR,Song HC,Kim JH,Cho JY,Hong YJ,Jabin Z,Park HJ,Jeong GC,Kwon SY,Paeng JC,Kim HS,Min JJ,Garcia EV,Bom HH

    更新日期:2017-02-01 00:00:00

  • Assessment of human effective absorbed dose of 67 Ga-ECC based on biodistribution rat data.

    abstract:OBJECTIVE:In a diagnostic context, determination of absorbed dose is required before the introduction of a new radiopharmaceutical to the market to obtain marketing authorization from the relevant agencies. In this work, the absorbed dose of [67 Ga]-ethylenecysteamine cysteine [(67 Ga)ECC] to human organs was determine...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0917-7

    authors: Shanehsazzadeh S,Yousefnia H,Lahooti A,Zolghadri S,Jalilian AR,Afarideh H

    更新日期:2015-02-01 00:00:00

  • A 3-variable prognostic score (3-PS) for overall survival prediction in metastatic castration-resistant prostate cancer treated with 223Radium-dichloride.

    abstract:OBJECTIVE:In mCRPC patients treated with 223Ra, a major issue is the validation of reliable prognostic and predictive biomarkers to maximize clinical benefit and minimize toxicities and costs. Bearing in mind how changes in tALP did not meet statistical requirements as surrogate marker for survival, aim of this single-...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-017-1228-6

    authors: Frantellizzi V,Farcomeni A,Follacchio GA,Pacilio M,Pellegrini R,Pani R,De Vincentis G

    更新日期:2018-02-01 00:00:00

  • Tc-99m MIBI SPECT in prediction of prognosis in patients with small cell lung cancer.

    abstract:PURPOSE:The purpose of this study was to evaluate whether the degree of technetium-99m methoxyisobutylisonitrile (MIBI) uptake and its retention in delayed imaging in small cell lung cancer (SCLC) was correlated with the response to multiagent chemotherapy and to investigate if there was a relationship between the surv...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02984643

    authors: Akgun A,Cok G,Karapolat I,Goksel T,Burak Z

    更新日期:2006-05-01 00:00:00

  • A comparative study of breast-specific gamma imaging with the conventional imaging modality in breast cancer patients with dense breasts.

    abstract:OBJECTIVE:The aim of this study was to evaluate the value of breast-specific gamma imaging (BSGI) as compared with mammography (MMG) and ultrasonography (US). METHODS:This study retrospectively enrolled 121 women with breast cancer (45.0 ± 8.1 years) and dense breasts (breast density >50 %). All patients underwent pre...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-012-0649-5

    authors: Kim BS,Moon BI,Cha ES

    更新日期:2012-12-01 00:00:00

  • Intravascular large B-cell lymphoma with diffuse FDG uptake in the lung by 18FDG-PET/CT without chest CT findings.

    abstract::We report a rare case of intravascular large B-cell lymphoma (IVLBCL) with diffuse fluorodeoxyglucose (FDG) uptake in the lung by (18)FDG-positron emission tomography/computed tomography (PET/CT). CT showed nodular shadow, whereas diffuse FDG uptake in PET/CT suggested IVLBCL in the lung. A random skin biopsy provided...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-012-0600-9

    authors: Yamashita H,Suzuki A,Takahashi Y,Kubota K,Kano T,Mimori A

    更新日期:2012-07-01 00:00:00

  • The significant value of predicting prognosis in patients with colorectal cancer using 18F-FDG PET metabolic parameters of primary tumors and hematological parameters.

    abstract:OBJECTS:The purpose was to evaluate the correlation of the pre-treatment hematological parameters with metabolic parameters of primary tumor in baseline 18F-FDG PET/CT in patients with colorectal cancer (CRC) and estimate the prognostic value of both. METHODS:We retrospectively investigated 231 patients with CRC who u...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-018-1299-z

    authors: Xu J,Li Y,Hu S,Lu L,Gao Z,Yuan H

    更新日期:2019-01-01 00:00:00

  • Uptake of 99mTc-tetrofosmin, 99mTc-MIBI and 201Tl in malignant thymoma.

    abstract::99mTc-tetrofosmin, Thallium-201-chloride (201Tl) and 99mTc-MIBI imagings were performed in a patient with malignant thymoma. Tracer uptake in the primary tumor was demonstrated. The tumor-to-background ratios of planar and SPECT imagings were 1.60 and 1.98 for 99mTc-tetrofosmin, 1.12 and 2.09 for 201Tl, and 1.19 and 1...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02988212

    authors: Hashimoto T,Goto K,Hishinuma Y,Yachuda K,Sugioka Y,Arai K,Harada S,Goto M

    更新日期:2000-08-01 00:00:00

  • Metallic artifacts caused by dental metal prostheses on PET images: a PET/CT phantom study using different PET/CT scanners.

    abstract:OBJECTIVE:The objective of this study was to investigate the effects of computed tomography (CT) artifacts caused by dental metal prostheses on positron emission tomography (PET) images. METHODS:A dental arch cast was fixed in a cylindrical water-bath phantom. A spherical phantom positioned in the vicinity of the dent...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-009-0254-4

    authors: Shimamoto H,Kakimoto N,Fujino K,Hamada S,Shimosegawa E,Murakami S,Furukawa S,Hatazawa J

    更新日期:2009-07-01 00:00:00

  • Maximal safe dose of I-131 after failure of standard fixed dose therapy in patients with differentiated thyroid carcinoma.

    abstract:OBJECTIVE:The maximal safe dose (MSD) on the basis of bone marrow irradiation levels allows the delivery of a large amount of I-131 to thyroid cancer tissue. The efficacy of MSD therapy in differentiated metastatic thyroid cancers that persisted after conventional fixed dose therapy is investigated. METHODS:Forty-seve...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/s12149-007-0179-8

    authors: Lee JJ,Chung JK,Kim SE,Kang WJ,Park DJ,Lee DS,Cho BY,Lee MC

    更新日期:2008-11-01 00:00:00

  • Pet tracers for vulnerable plaque imaging.

    abstract::Most of the acute ischemic events, such as acute coronary syndromes and stroke, are attributed to vulnerable plaques. These lesions have common histological and pathophysiological features, including inflammatory cell infiltration, neo-angiogenesis, remodelling, haemorrhage predisposition, thin fibrous cap, large lipi...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s12149-020-01458-7

    authors: Giannakou S,Angelidis G,Tsougos I,Valotassiou V,Kappas K,Georgoulias P

    更新日期:2020-05-01 00:00:00

  • Characteristics of single- and dual-photopeak energy window acquisitions with thallium-201 IQ-SPECT/CT system.

    abstract:OBJECTIVES:Although dual-energy (DE) acquisition with conventional 201Tl myocardial perfusion SPECT has several advantages such as improved attenuation of the inferior wall and increased acquisition counts, the characteristics of IQ-SPECT have not been fully evaluated. We evaluate the difference of characteristics betw...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-017-1177-0

    authors: Shibutani T,Onoguchi M,Yoneyama H,Konishi T,Matsuo S,Nakajima K,Kinuya S

    更新日期:2017-08-01 00:00:00

  • Usefulness of a breath-holding acquisition method in PET/CT for pulmonary lesions.

    abstract:OBJECTIVE:To evaluate the usefulness of a breath-holding (BH) (18)F-2-fluoro-2-deoxy-D-glucose positron emission tomography ((18)F-FDG-PET) technique for PET/computed tomography (CT) scanning of pulmonary lesions near the diaphragm, where image quality is influenced by respiratory motion. METHODS:In a basic study, sim...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-008-0206-4

    authors: Yamaguchi T,Ueda O,Hara H,Sakai H,Kida T,Suzuki K,Adachi S,Ishii K

    更新日期:2009-01-01 00:00:00

  • Correction of scattered photons in Tc-99m imaging by means of a photopeak dual-energy window acquisition.

    abstract::We are proposing a new method for correcting of scattered photons in technetium-99m (99mTc) imaging by means of photopeak dual-energy window acquisition. This method consists of the simultaneous acquisition of two images and estimation of a scatter image included in the symmetric energy window (SW) image by the differ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178307

    authors: Kojima A,Tsuji A,Takaki Y,Tomiguchi S,Hara M,Matsumoto M,Takahashi M

    更新日期:1992-08-01 00:00:00

  • Present diagnostic strategies for acute pulmonary thromboembolism; results of a questionnaire in a retrospective trial conducted by the Respiratory Nuclear Medicine Working Group of the Japanese Society of Nuclear Medicine.

    abstract::The aim of this study is to re-evaluate and clarify the diagnostic role of ventilation/perfusion lung scintigraphy in Japan, now that single-detector-row helical CT and multidetector-row CT are available in clinical practice. The Respiratory Nuclear Medicine Working Group of the Japanese Society of Nuclear Medicine di...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02988632

    authors: Kawamoro M,Ogura Y,Honda N,Satoh K,Suga K,Mori Y,Imai T,Inoue T,Narabayashi I

    更新日期:2002-12-01 00:00:00

  • Single photon emission computed tomography with Tc-99m-dimercaptosuccinic acid in patients with upper urinary tract infection and/or vesicoureteral reflux.

    abstract::By means of Tc-99m dimercaptosuccinic acid (DMSA) scintigraphy, an established method for assessing renal cortical damage, we evaluated the pick-up rate for renal defects (scars) by single photon computed tomography (SPECT) and planar images of 10 normal volunteers, and 58 patients (70 scintigrams) with upper urinary ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164610

    authors: Itoh K,Asano Y,Tsukamoto E,Kato C,Nakada K,Nagao K,Furudate M,Gotoh T,Nonomura K,Koyanagi T

    更新日期:1991-03-01 00:00:00

  • Assessment of liver function in chronic liver diseases and regional function of irradiated liver by means of 99mTc-galactosyl-human serum albumin liver scintigraphy and quantitative spectral analysis.

    abstract::Scintigraphy with 99mTc-diethylenetriamine pentaacetic acid galactosyl human serum albumin (99mTc-GSA) was performed on 102 patients, then the hepatic extraction fraction (HEF), the rate constant for liver uptake of the tracer from the blood (K1) and the hepatic blood flow index (HBFI) were determined by spectral anal...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02988293

    authors: Fukui A,Murase K,Tsuda T,Fujii T,Ikezoe J

    更新日期:2000-12-01 00:00:00

  • Association of tau accumulation and atrophy in mild cognitive impairment: a longitudinal study.

    abstract:OBJECTIVE:To examine the patterns of longitudinal tau accumulation and cortical atrophy and their association in subjects with mild cognitive impairment (MCI). METHODS:We collected 23 participants (60-89 years old, 11 males/12 females) with MCI from the Alzheimer's Disease Neuroimaging Initiative database. All partici...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01506-2

    authors: Xu G,Zheng S,Zhu Z,Yu X,Jiang J,Jiang J,Chu Z,Alzheimer’s Disease Neuroimaging Initiative.

    更新日期:2020-11-01 00:00:00

  • Myocardial glucose metabolism in patients with hypertrophic cardiomyopathy: assessment by F-18-FDG PET study.

    abstract::In an investigation of myocardial metabolic abnormalities in hypertrophic myocardium, the myocardial glucose metabolism was evaluated with F-18-fluorodeoxyglucose (FDG) positron emission tomography (PET) in 32 patients with hypertrophic cardiomyopathy, and the results were compared with those in 9 patients with hypert...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164836

    authors: Uehara T,Ishida Y,Hayashida K,Shimonagata T,Miyake Y,Sago M,Oka H,Nagata S,Miyatake K,Nishimura T

    更新日期:1998-04-01 00:00:00

  • Attenuation correction using combination of a parallel hole collimator and an uncollimated non-uniform line array source.

    abstract::Attenuation correction is very important for quantitative SPECT imaging. We designed an uncollimated non-uniform line array source (non-uniform LAS) for attenuation correction based on transmission computed tomography (TCT) using Tc-99m and compared its performance with an uncollimated uniform line array source (unifo...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02984481

    authors: Kojima A,Kawanaka K,Nakaura T,Shiraishi S,Utsunomiya D,Katsuda N,Tomiguchi S,Yamashita Y,Matsumoto M,Motomura N,Ichihara T

    更新日期:2004-07-01 00:00:00

  • An anthropomorphic pelvis phantom for optimization of the diagnosis of lymph node metastases in the pelvis.

    abstract:OBJECTIVE:An anthropomorphic pelvis phantom was made by the modification of a National Electrical Manufacturers Association (NEMA) phantom, currently the most popular one, and its clinical usefulness was evaluated. METHODS:The NEMA plus bone phantom was made by placing the pelvic bone model in the NEMA phantom. The NE...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-009-0229-5

    authors: Inoue K,Sato T,Kitamura H,Hirayama A,Kurosawa H,Tanaka T,Fukushi M,Moriyama N,Fujii H

    更新日期:2009-05-01 00:00:00

  • Diagnostic utility and characteristics of CT-based attenuation correction in brain perfusion SPECT/CT in predicting the exacerbation of Alzheimer changes from mild cognitive impairment utilizing voxel-based statistical analysis in comparison with Chang's

    abstract:OBJECTIVE:We examined the diagnostic value of brain perfusion single-photon emission computed tomography (SPECT) using voxel-based statistical analysis with CT-based attenuation correction (CT-AC) by comparing it to that with Chang's AC in mild cognitive impairment (MCI) patients and attempted to locate brain areas tha...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01477-4

    authors: Sohara K,Kiriyama T,Mizumura S,Ishiwata A,Yamazaki M,Kimura K,Kumita SI

    更新日期:2020-07-01 00:00:00