High detection sensitivity and reliable morphological correlation of PET with a silicon photomultiplier for primary tongue squamous cell carcinoma.

Abstract:

OBJECTIVE:A positron emission tomography (PET) scanner using a silicon photomultiplier (SiPM PET) in place of a photomultiplier tube significantly improves the spatial and time resolution. It may also improve the evaluation of smaller lesions compared to conventional (non-SiPM) PET scanners. We compared the maximum standardized uptake value (SUVmax), detection sensitivity, and morphological correlation using magnetic resonance imaging (MRI) for primary tongue squamous cell carcinoma between the SiPM PET and non-SiPM PET scanner. METHODS:We retrospectively reviewed the F-18 fluorodeoxyglucose (FDG) PET/CT features of tongue squamous cell carcinomas in consecutive, newly diagnosed, and pathologically verified patients. Twenty-five of 46 patients were scanned using SiPM PET scanner and the remaining 21 patients were scanned with a non-SiPM PET scanner. We compared the SUVmax and visual evaluation of primary tumor detectability, and the correlation between the PET-based and MRI-based tumor size (long axis, thickness, and volume). Differences in SUVmax and detection sensitivity for the primary tumor were analyzed using Welch's t test and Fisher's exact test, respectively. Correlations among the PET-based, MRI-based tumor size, and SUVmax were assessed using Spearman's rank correlation coefficient. RESULTS:SUVmax of both T1/T2 and T3/T4 primary tumors were significantly higher for the SiPM PET (T1/T2 mean SUVmax: 6.6 ± 4.3, T3/T4 mean SUVmax: 18.2 ± 9.8) than that for the non-SiPM PET (T1/T2 mean SUVmax: 3.4 ± 1.4, T3/T4 mean SUVmax: 10.2 ± 4.9) (P < 0.05). While all cases of T3/T4 primary tumors were detected by both PET scanners, the detection sensitivity for T1/T2 primary tumors was significantly higher for the SiPM PET (80%) than that for the non-SiPM PET (36.4%) (P < 0.05). MRI-based tumor size correlated significantly with SiPM PET-based tumor long axis (ρ = 0.74) and volume (ρ = 0.91), but not with the non-SiPM PET-based tumor long axis and volume in T1/T2 primary lesions. Correlation between MRI-based tumor size and SUVmax was significant in both PET scanners; however, no significant difference was observed between the two scanners. CONCLUSIONS:The SiPM PET provides better detection sensitivity and a reliable morphological correlation for the T1/T2 primary tongue tumors than the non-SiPM PET due to its high performance.

journal_name

Ann Nucl Med

authors

Kojima I,Takanami K,Ogawa T,Sakamoto M,Nagai H,Miyashita H,Iikubo M

doi

10.1007/s12149-020-01489-0

subject

Has Abstract

pub_date

2020-09-01 00:00:00

pages

643-652

issue

9

eissn

0914-7187

issn

1864-6433

pii

10.1007/s12149-020-01489-0

journal_volume

34

pub_type

杂志文章
  • Subcellular distribution of thallium: morphological and quantitative study in rat myocardium.

    abstract:UNLABELLED:The purpose of this study is to determine the subcellular distribution of thallium (SDTl) by electron microscopy and a newly designed fixation method that makes insoluble grains of Tl visible. METHODS:To obtain the high dose necessary for electron microscopic visualization, we employed TlCl instead of 201Tl...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03165296

    authors: Fukumoto M,Yoshida D,Yoshida S

    更新日期:1997-11-01 00:00:00

  • Characteristics of single- and dual-photopeak energy window acquisitions with thallium-201 IQ-SPECT/CT system.

    abstract:OBJECTIVES:Although dual-energy (DE) acquisition with conventional 201Tl myocardial perfusion SPECT has several advantages such as improved attenuation of the inferior wall and increased acquisition counts, the characteristics of IQ-SPECT have not been fully evaluated. We evaluate the difference of characteristics betw...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-017-1177-0

    authors: Shibutani T,Onoguchi M,Yoneyama H,Konishi T,Matsuo S,Nakajima K,Kinuya S

    更新日期:2017-08-01 00:00:00

  • Myocardial glucose metabolism in patients with hypertrophic cardiomyopathy: assessment by F-18-FDG PET study.

    abstract::In an investigation of myocardial metabolic abnormalities in hypertrophic myocardium, the myocardial glucose metabolism was evaluated with F-18-fluorodeoxyglucose (FDG) positron emission tomography (PET) in 32 patients with hypertrophic cardiomyopathy, and the results were compared with those in 9 patients with hypert...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164836

    authors: Uehara T,Ishida Y,Hayashida K,Shimonagata T,Miyake Y,Sago M,Oka H,Nagata S,Miyatake K,Nishimura T

    更新日期:1998-04-01 00:00:00

  • Bremsstrahlung parameters of praseodymium-142 in different human tissues: a dosimetric perspective for (142)Pr radionuclide therapy.

    abstract:OBJECTIVE:Praseodymium-142 [T 1/2 = 19.12 h, [Formula: see text] = 2.162 MeV (96.3%), Eγ = 1575 keV (3.7%)] is one of the (141)Pr radioisotopes. Many studies have been attempted to assess the significance of usage (142)Pr in radionuclide therapy. In many studies, the dosimetric parameters of (142)Pr sources were calcul...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-012-0591-6

    authors: Bakht MK,Jabal-Ameli H,Ahmadi SJ,Sadeghi M,Sadjadi S,Tenreiro C

    更新日期:2012-06-01 00:00:00

  • A brain uptake study of [1-(11)C]hexanoate in the mouse: the effect of hypoxia, starvation and substrate competition.

    abstract::We evaluated the potential of sodium [1-(11)C]hexanoate (11C-HA) as a radiopharmaceutical with which to assess oxidative metabolism of the brain by PET. 11C-HA, sodium [1-(14)C]acetate and [3H]deoxyglucose were simultaneously injected into mice under control, hypoxic and starving conditions. In the control, the brain ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03165404

    authors: Ishiwata K,Ishii K,Ogawa K,Nozaki T,Senda M

    更新日期:1996-05-01 00:00:00

  • A case of recurrent cholangitis after bile duct injury during laparoscopic cholecystectomy: value of scintigraphy with Tc-99m GSA and hepatobiliary scintigraphy for indication of lobectomy.

    abstract::A 39-year-old woman with acute cholecystitis and gallstones underwent laparoscopic cholecystectomy. She suffered from recurrent episodes of cholangitis due to injury of the major bile ducts during laparoscopic cholecystectomy. Hepatobiliary scintigraphy with Tc-99m Sn-N-pyridoxyl-5-methyltryptophan was performed. Alth...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02988702

    authors: Nishiguchi S,Shiomi S,Sasaki N,Iwata Y,Tanaka H,Kubo S,Hirohashi K,Ochi H

    更新日期:2000-10-01 00:00:00

  • Prognostic role of baseline 18F-FDG PET/CT metabolic parameters in mantle cell lymphoma.

    abstract:OBJECTIVE:Mantle cell lymphoma (MCL) is an aggressive lymphoma sub-type with poor prognosis and high 18F-FDG avidity at PET/CT; nowadays, no validated criteria for PET/CT in treatment response evaluation and prediction of outcome are present. The aim of study was to investigate whether the metabolic PET/CT features may...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-019-01354-9

    authors: Albano D,Bosio G,Bianchetti N,Pagani C,Re A,Tucci A,Giubbini R,Bertagna F

    更新日期:2019-07-01 00:00:00

  • Can (18)F-FDG-PET/CT be generally recommended in patients with differentiated thyroid carcinoma and elevated thyroglobulin levels but negative I-131 whole body scan?

    abstract:BACKGROUND:Exact localization of recurrent iodine-negative thyroid cancer is mandatory, since surgery is the only curative therapy option in patients with iodine-negative tumor tissue. The aim of this study was to evaluate the impact of (18)F-FDG-PET/CT as a routine diagnostic tool on clinical management in patients wi...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-011-0545-4

    authors: Bannas P,Derlin T,Groth M,Apostolova I,Adam G,Mester J,Klutmann S

    更新日期:2012-01-01 00:00:00

  • Unusual patterns of I-131 contamination.

    abstract::Whole body imaging with radioiodine can detect functioning metastases, which can often be effectively treated with appropriate amounts of radioiodine. Non-physiologic I-131 uptake detected on images is usually interpreted as suggesting functioning thyroid metastases. However, extra-thyroidal I-131 accumulation does no...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02985010

    authors: Ozguven M,Ilgan S,Arslan N,Karacalioglu AO,Yuksel D,Dundar S

    更新日期:2004-05-01 00:00:00

  • Assessment of cardiac function in patients with heart disease by quantitative gated myocardial perfusion SPECT.

    abstract:OBJECTIVE:We examined the cardiac function of patients who underwent Tc-99m sestamibi quantitative gated myocardial single photon emission computed tomography with 16-framing data acquisition between January 1, 2004 and March 31, 2006 for an evaluation of suspected or known heart disease in our hospital. METHODS:In 19...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-007-0032-0

    authors: Nakae I,Matsuo S,Tsutamoto T,Matsumoto T,Mitsunami K,Horie M

    更新日期:2007-08-01 00:00:00

  • Comparison of integrated whole-body PET/MR and PET/CT: Is PET/MR alternative to PET/CT in routine clinical oncology?

    abstract:PURPOSE:To compare the diagnostic accuracy of whole-body PET/CT and integrated PET/MR in relation to the total scan time durations. METHODS:One hundred and twenty-three (123) patients (40 males and 83 females; mean age 59.6 years; range 20-83 years) with confirmed primary cancer and clinical suspicion of metastatic di...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-015-1050-y

    authors: Ishii S,Shimao D,Hara T,Miyajima M,Kikuchi K,Takawa M,Kumamoto K,Ito H,Shishido F

    更新日期:2016-04-01 00:00:00

  • An animal PET scanner using flat-panel position-sensitive PMTs.

    abstract:OBJECTIVE:To design, build, and evaluate an animal PET scanner, which can be used with non-human primates under conscious condition, incorporating flat-panel position-sensitive photomultiplier tubes (PS-PMTs). METHODS:The system contains 30 detector modules, each having two PS-PMTs and 16×18 lutetium–yttrium oxyortho-...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-013-0772-y

    authors: Okamoto T,Ote K,Sakai K,Noda A,Shimizu K,Masuda K,Ohmura T,Watanabe M

    更新日期:2014-01-01 00:00:00

  • Improvement in automated quantitation of myocardial perfusion abnormality by using iterative reconstruction image in combination with resolution recovery, attenuation and scatter corrections for the detection of coronary artery disease.

    abstract:OBJECTIVE:An iterative reconstruction method in combination with resolution recovery, attenuation and scatter corrections (IR-RASC) can improve image quality. It, however, is undetermined whether this technique can improve the detection of coronary artery disease (CAD) when automated quantitative analysis is used. This...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-016-1146-z

    authors: Chono T,Onoguchi M,Shibutani T,Hashimoto A,Nakata T,Yama N,Tsuchihashi K,Hatakenaka M

    更新日期:2017-02-01 00:00:00

  • Myocardial accumulation of a dopamine D2 receptor-binding radioligand, 2'-iodospiperone.

    abstract::125I-2'-iodospiperone (2'-ISP), which has a high and selective affinity for dopamine D2 receptors, produced a high myocardial accumulation of radioactivity in the early phase after intravenous injection into mice. A human scintigraphic study also showed that the myocardium was clearly visualized soon after intravenous...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164959

    authors: Saji H,Yonekura Y,Tanahashi K,Iida Y,Iwasaki Y,Magata Y,Konishi J,Yokoyama A

    更新日期:1993-08-01 00:00:00

  • Comparison of subareolar injection lymphoscintigraphy with the 1-day and the 2-day protocols for the detection of sentinel lymph nodes in patients with breast cancer.

    abstract:OBJECTIVE:Lymphoscintigraphy and sentinel node biopsy are used for the detection of axillary lymph node metastasis in breast cancer patients. However, currently there is no standardized technique. For the detection of axillary lymph node metastasis by lymphoscintigraphy and sentinel node biopsy, in patients with breast...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-009-0259-z

    authors: Seok JW,Kim IJ,Heo YJ,Yang YJ,Choi YS,Kim BG,Park SJ

    更新日期:2009-07-01 00:00:00

  • European research trends in nuclear medicine.

    abstract::Written by associate editors of the Annals of Nuclear Medicine, this invited review article is intended to offer our readers a condensed global view on the high-quality research work that has been published in Europe last year. We have divided this article into five sections. The first three sections from the oncology...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s12149-018-1303-7

    authors: Inubushi M,Tatsumi M,Yamamoto Y,Kato K,Tsujikawa T,Nishii R

    更新日期:2018-11-01 00:00:00

  • Assessment of absolute Tc-99m tetrofosmin retention in the myocardium as an index of myocardial blood flow and coronary flow reserve by gated-SPECT/CT: a feasibility study.

    abstract:OBJECTIVE:Estimation of myocardial blood flow (MBF) and coronary flow reserve (CFR) by SPECT myocardial perfusion imaging (MPI) remains challenging. Our aim was to approximate MBF and CFR by quantifying the absolute Tc-99m tetrofosmin retention in the myocardium via gated-SPECT/CT MPI. METHODS:Tracer retention was cal...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/s12149-015-0982-6

    authors: Apostolopoulos DJ,Kaspiri A,Spyridonidis T,Patsouras N,Savvopoulos CA,Davlouros P,Vassilakos PJ,Alexopoulos D

    更新日期:2015-08-01 00:00:00

  • Incidental focal 18F-FDG uptake in the frontal process of the maxilla on PET/CT: prevalence and clinical significance.

    abstract:OBJECTIVE:We investigated the prevalence and clinical significance of incidental focal 18F-FDG uptake in the frontal process of the maxilla, mimicking malignancy on PET/CT. METHODS:From a total of 32,834 patients who underwent 18F-FDG PET/CT, patients with focal uptake in the frontal process of the maxilla were select...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-016-1103-x

    authors: Park SB,Choi JY,Kim HJ,Kim HJ,Lee KH,Kim BT

    更新日期:2016-11-01 00:00:00

  • Scintigraphic changes in bone metastasis from prostate cancer after hormonal therapy--comparison with tumor markers and bone X-ray.

    abstract::Bone scintigraphy is often performed to assess the response to systemic therapy of bone metastasis from prostate cancer. We examined the changes in bone scintigraphic findings and the agreement with AIP, AcP, or other tumor markers measured in the follow-up of patients with known bone metastasis after hormonal therapy...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF03165024

    authors: Koizumi K,Uchiyama G,Komatsu H

    更新日期:1994-11-01 00:00:00

  • Introduction of the targeted alpha therapy (with Radium-223) into clinical practice in Japan: learnings and implementation.

    abstract::Radium-223 dichloride (Ra-223) is the first targeted alpha therapy approved for the treatment of patients with castration-resistant prostate cancer (CRPC) with bone metastasis. Ra-223 improved overall survival in the international Phase III ALSYMPCA (ALpharadin in SYMPtomatic Prostate Cancer) study. Ra-223 was also de...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-018-1317-1

    authors: Hosono M,Ikebuchi H,Nakamura Y,Yanagida S,Kinuya S

    更新日期:2019-03-01 00:00:00

  • Lesion detectability of a gamma camera based coincidence system with FDG in patients with malignant tumors: a comparison with dedicated positron emission tomography.

    abstract:OBJECTIVE:The aim of this study was to investigate the lesion detectability of a gamma camera based coincidence detector system (c-PET system) in comparison to the dedicated PET system (d-PET system), and thereby clarify the feasibility of the clinical application of this system and also describe any factors influencin...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02985103

    authors: Koga H,Sasaki M,Kuwabara Y,Nakagawa M,Hayashi K,Kaneko K,Chen T,Honda H

    更新日期:2004-04-01 00:00:00

  • Ordered subset expectation maximisation vs Bayesian penalised likelihood reconstruction algorithm in 18F-PSMA-1007 PET/CT.

    abstract:BACKGROUND:The aim of the study was to compare widely used ordered subset expectation maximisation (OSEM) algorithm with a new Bayesian penalised likelihood (BPL) Q.Clear algorithm in 18F-PSMA-1007 PET/CT. METHODS:We retrospectively assessed 25 18F-PSMA-1007 PET/CT scans with both OSEM and Q.Clear reconstructions avai...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-019-01433-x

    authors: Witkowska-Patena E,Budzyńska A,Giżewska A,Dziuk M,Walęcka-Mazur A

    更新日期:2020-03-01 00:00:00

  • Peritoneal tuberculosis with elevated serum CA125 mimicking peritoneal carcinomatosis on F-18 FDG-PET/CT.

    abstract::18F-fluorodeoxyglucose positron emission tomography (F-18 FDG-PET) plays an important role in differentiating benign from malignant tumors. However, some false-positive findings, such as tuberculosis, may occur. We report a case referred for F-18 FDG whole-body PET computed tomography (PET/CT) scan owing to an elevate...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-008-0139-y

    authors: Chen CJ,Yao WJ,Chou CY,Chiu NT,Lee BF,Wu PS

    更新日期:2008-07-01 00:00:00

  • Uptake and washout of I-123-MIBG in neuronal and non-neuronal sites in rat hearts: relationship to renal clearance.

    abstract::We investigated the uptake and washout of I-123-metaiodobenzylguanidine (MIBG) in neuronal (both intra- and extravesicular) and non-neuronal sites in the heart and its relationship to renal clearance. Acute renal failure was induced in rats by ligating the renal vessels, and the findings were compared with those of sh...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03165394

    authors: Arbab AS,Koizumi K,Araki T

    更新日期:1996-05-01 00:00:00

  • Assessment of human effective absorbed dose of 67 Ga-ECC based on biodistribution rat data.

    abstract:OBJECTIVE:In a diagnostic context, determination of absorbed dose is required before the introduction of a new radiopharmaceutical to the market to obtain marketing authorization from the relevant agencies. In this work, the absorbed dose of [67 Ga]-ethylenecysteamine cysteine [(67 Ga)ECC] to human organs was determine...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0917-7

    authors: Shanehsazzadeh S,Yousefnia H,Lahooti A,Zolghadri S,Jalilian AR,Afarideh H

    更新日期:2015-02-01 00:00:00

  • Semiquantitative analysis of C-11 methionine PET may distinguish brain tumor recurrence from radiation necrosis even in small lesions.

    abstract:OBJECTIVE:(11)C-Methionine positron emission tomography (MET-PET) has been used to distinguish brain tumor recurrence from radiation necrosis. Because the spatial resolution of conventional PET scanners is low, partial volume effect (PVE) may decrease the detectability of small tumor recurrence. The aim of this study i...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-010-0450-2

    authors: Okamoto S,Shiga T,Hattori N,Kubo N,Takei T,Katoh N,Sawamura Y,Nishijima K,Kuge Y,Tamaki N

    更新日期:2011-04-01 00:00:00

  • The use of quantitative scintigraphy in the measurement of portal-systemic shunting in rats.

    abstract::Portal-systemic shunting was studied in 54 portal hypertensive rats both in vivo and in vitro using radioactive microspheres. The animals underwent partial portal vein ligation around needles of varying diameter to produce a wide range of shunting. Two to four weeks later, quantitative lung-liver scintigraphic and who...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164656

    authors: Stauber RE,Mochizuki T,Van Thiel DH,Tauxe WN

    更新日期:1992-11-01 00:00:00

  • Association of tau accumulation and atrophy in mild cognitive impairment: a longitudinal study.

    abstract:OBJECTIVE:To examine the patterns of longitudinal tau accumulation and cortical atrophy and their association in subjects with mild cognitive impairment (MCI). METHODS:We collected 23 participants (60-89 years old, 11 males/12 females) with MCI from the Alzheimer's Disease Neuroimaging Initiative database. All partici...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01506-2

    authors: Xu G,Zheng S,Zhu Z,Yu X,Jiang J,Jiang J,Chu Z,Alzheimer’s Disease Neuroimaging Initiative.

    更新日期:2020-11-01 00:00:00

  • Intratumoral heterogeneity in 18F-FDG PET/CT by textural analysis in breast cancer as a predictive and prognostic subrogate.

    abstract:AIM:To assess the predictive and prognostic value of textural parameters in locally advanced breast cancer (LABC) obtained by 18F-FDG PET/CT. METHODS:Prospective study including 68 patients with LABC, neoadjuvant chemotherapy (NC) indication and a baseline 18F-FDG PET/CT. Breast specimens were grouped into molecular p...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-018-1253-0

    authors: Molina-García D,García-Vicente AM,Pérez-Beteta J,Amo-Salas M,Martínez-González A,Tello-Galán MJ,Soriano-Castrejón Á,Pérez-García VM

    更新日期:2018-07-01 00:00:00

  • Assessment of cerebral hemodynamics before and after revascularization in patients with occlusive cerebrovascular disease by means of quantitative IMP-SPECT with double-injection protocol.

    abstract:UNLABELLED:The purpose of this study was to validate a double-injection (DI) method with N-isopropyl-[123I]p-iodoamphetamine (IMP) to measure regional cerebral blood flow (rCBF) twice in a single session of dynamic SPECT and to elucidate a possible role of this method to identify patients with occlusive disease of majo...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02987833

    authors: Ueno M,Nishizawa S,Toyoda H,Shimono T,Miyamoto S,Hashimoto N,Konishi J

    更新日期:2001-06-01 00:00:00