(99m)Tc-DTPA dynamic SPECT and CT volumetry for measuring split renal function in live kidney donors.

Abstract:

OBJECTIVES:Split renal function (SRF) estimated from the posterior view of (99m)Tc-diethylenetriaminepentaacetic acid planar scintigraphy (DTPA/P) is not sufficiently accurate even after correction for kidney depth by computed tomography (CT). To obtain more accurate SRF using (99m)Tc-DTPA, dynamic SPECT method was carried out for the initial 5 min after bolus injection of (99m)Tc-DTPA (DTPA/SPECT). Also SRF was evaluated from the renal volume measured by CT. We compared the results with (99m)Tc-dimercaptosuccinic acid SPECT (DMSA/SPECT). METHODS:In 60 consecutive live kidney donors, 30 DTPA/P, 30 DTPA/SPECT, 60 (99m)Tc-DMSA/SPECT, and 60 CT studies were performed. In the DTPA/P studies, SRF was calculated from the posterior image recorded during 2-3-min postinjection with attenuation correction for kidney depth measured by CT. In the DTPA/SPECT studies, SPECT images were acquired continuously for 5 min with a dual-headed gamma camera. In (99m)Tc-DMSA scintigraphy, DMSA/SPECT images were acquired 3-h postinjection. The SRF on both SPECT studies was calculated from the total counts of each kidney. In the DTPA/SPECT study, SRF was evaluated on the three images summed for 1 min: 1-2 min (DTPA/SPECT1-2), 2-3 min (DTPA/SPECT2-3), and 1-3 min (DTPA/SPECT1-3). In the CT examination, to assess the global renal volume, the axial images in the excretory phase were chosen. Renal contours were identified on each image, and the areas (cm(2)) of these regions were summed and multiplied by the slice thickness (10 mm) to yield global renal volume (ml). Right renal function from DTPA/P, DTPA/SPECT, and CT were compared with that from DMSA/SPECT as a reference. RESULTS:Correlation coefficients of the right renal function between DMSA/SPECT and DTPA/P, DTPA/SPECT2-3, and CT were 0.663, 0.849 and 0.907, respectively (P < 0.0001). The differences between DMSA/SPECT and DTPA/P, DTPA/SPECT2-3 and CT were 2.42 +/- 3.878, 0.867 +/- 1.672, and -0.421 +/- 1.077% (mean +/- SD), respectively. CONCLUSION:SRF derived from DTPA/SPECT showed a better correlation with DMSA/SPECT and significantly fewer errors (P < 0.05) than DTPA/P. A significant strong correlation was observed between SRF from DMSA/SPECT and CT, indicating the utility of CT renal volumetry for evaluating SRF.

journal_name

Ann Nucl Med

authors

Miyazaki C,Harada H,Shuke N,Okizaki A,Miura M,Hirano T

doi

10.1007/s12149-010-0349-y

subject

Has Abstract

pub_date

2010-04-01 00:00:00

pages

189-95

issue

3

eissn

0914-7187

issn

1864-6433

journal_volume

24

pub_type

杂志文章
  • The search for consistency in the manufacture of PET radiopharmaceuticals.

    abstract::Nuclear Medicine is the specialty of medical imaging, which utilizes a variety of radionuclides incorporated into specific compounds for diagnostic imaging and therapeutic applications. During recent years, research efforts in this discipline have concentrated on the decay characteristics of particular radionuclides a...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/BF03164930

    authors: Finn RD

    更新日期:1999-12-01 00:00:00

  • Morphine-augmented cholescintigraphy enhances duodenogastric reflux.

    abstract::Morphine intervention in cholescintigraphy decreases imaging time to diagnose acute cholecystitis. Not infrequently we observe duodenogastric reflux during scintigraphy with and without morphine intervention. To evaluate occurrence of duodenogastric reflux related to morphine, we reviewed 55 patients who underwent cho...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03168405

    authors: Shih WJ,Lee JK,Magoun S,Wierzbinski B,Ryo UY

    更新日期:1995-11-01 00:00:00

  • Aortic knob width reflects left ventricular diastolic function assessed by gated myocardial perfusion single photon emission computed tomography in patients with normal myocardial perfusion.

    abstract:BACKGROUND:Aortic knob width on chest radiography represents the extent of aortic dialation and tortuosity of the aortic arch. We tested the hypothesis that aortic knob width reflected left ventricular (LV) diastolic function assessed by gated myocardial perfusion single photon emission computed tomography (SPECT) in p...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-017-1150-y

    authors: Kurisu S,Higaki T,Sumimoto Y,Ikenaga H,Watanabe N,Ishibashi K,Dohi Y,Fukuda Y,Kihara Y

    更新日期:2017-04-01 00:00:00

  • Evaluation of treatment effects in brain abscess with positron emission tomography: comparison of fluorine-18-fluorodeoxyglucose and carbon-11-methionine.

    abstract::Positron emission tomography (PET) imaging is in common use preoperatively to clinically evaluate patients who present with central nervous system mass lesions. The usefulness of PET is also recognized as a method to detect intracranial tumorous lesions. A number of papers reportthat some inflammatory processes also s...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02988258

    authors: Tsuyuguchi N,Sunada I,Ohata K,Takami T,Nishio A,Hara M,Kawabe J,Okamura T,Ochi H

    更新日期:2003-02-01 00:00:00

  • [99mTc]3PRGD2 for integrin receptor imaging of esophageal cancer: a comparative study with [18F]FDG PET/CT.

    abstract:OBJECTIVES:This study was designed to investigate the efficacy of 99mtechnetium-three polyethylene glycol spacers-arginine-glycine-aspartic acid ([99mTc]3PRGD2) in the evaluation of patients with esophageal cancer. METHODS:Twenty-nine patients with a suspected esophageal lesion and for whom definite pathological diagn...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/s12149-018-1315-3

    authors: Zheng S,Chen Z,Huang C,Chen Y,Miao W

    更新日期:2019-02-01 00:00:00

  • Usefulness of the Chang attenuation correction method with use of a CT-based μ map by FBP reconstruction in (201)Tl SPECT-MPI.

    abstract:OBJECTIVE:Attenuation correction (AC) on nuclear images of non-uniform domains is generally performed by a change of the computed tomography (CT) values to μ values, which are then inserted as components into the detection probability of iterative reconstruction techniques (OS-EM Iterative AC). We established an AC tec...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-015-0972-8

    authors: Nakamura Y,Tomiguchi S

    更新日期:2015-06-01 00:00:00

  • Assessment of hepatic functional regeneration after hepatectomy using (99m)Tc-GSA SPECT/CT fused imaging.

    abstract:BACKGROUND:The liver itself regenerates after hepatectomy but little is known about how much hepatic function recovers during the regeneration. The liver uptake value (LUV), calculated from Tc-99m-labeled galactosyl-human-serum-albumin ((99m)Tc-GSA) SPECT/CT fused images, is reliable and useful for evaluating hepatic f...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0872-3

    authors: Yoshida M,Shiraishi S,Sakamoto F,Beppu T,Utsunomiya D,Okabe H,Tomiguchi S,Baba H,Yamashita Y

    更新日期:2014-10-01 00:00:00

  • Dual-radionuclide simultaneous gastric emptying and bile transit study after gastric surgery with double-tract reconstruction.

    abstract:OBJECTIVE:The physiology of gastrointestinal transfer function after proximal gastrectomy with bypass-tract reconstruction is not well understood. We applied a simultaneous dual-radionuclide method with a hepatobiliary imaging and gastric emptying study to evaluate physiologic alterations occurring after surgery. METH...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02984603

    authors: Nakajima K,Kawano M,Kinami S,Fujimura T,Miwa K,Tonami N

    更新日期:2005-05-01 00:00:00

  • Relationship between bone scintigraphy and tumor markers in patients with breast cancer.

    abstract:PURPOSE:The aim of this study is to specify the precise role of bone scintigraphy and serum CEA and CA 15-3 assays in the monitoring of breast cancers in order to optimize their use and to determine whether it is possible to guide the prescription of bone scan by the use of CEA and CA 15-3 assays in the monitoring of b...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02984567

    authors: Yildiz M,Oral B,Bozkurt M,Cobaner A

    更新日期:2004-09-01 00:00:00

  • Investigation of single, random, and true counts from natural radioactivity in LSO-based clinical PET.

    abstract:OBJECTIVE:Lutetium oxyorthosilicate (LSO) contains natural radioactivity that emits beta particles and three gamma photons simultaneously. These beta particles and gamma photons increase the single and random rates in a positron emission tomography (PET) system while a beta particle and gamma photon produced in the sam...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03027389

    authors: Yamamoto S,Horii H,Hurutani M,Matsumoto K,Senda M

    更新日期:2005-04-01 00:00:00

  • Characteristics of single- and dual-photopeak energy window acquisitions with thallium-201 IQ-SPECT/CT system.

    abstract:OBJECTIVES:Although dual-energy (DE) acquisition with conventional 201Tl myocardial perfusion SPECT has several advantages such as improved attenuation of the inferior wall and increased acquisition counts, the characteristics of IQ-SPECT have not been fully evaluated. We evaluate the difference of characteristics betw...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-017-1177-0

    authors: Shibutani T,Onoguchi M,Yoneyama H,Konishi T,Matsuo S,Nakajima K,Kinuya S

    更新日期:2017-08-01 00:00:00

  • Choline PET/CT for imaging prostate cancer: an update.

    abstract::Whole-body positron emission tomography/computed tomography (PET/CT) with [(11)C]- and [(18)F]-labeled choline derivates has emerged as a promising molecular imaging modality for the evaluation of prostate cancer. (11)C- and (18)F-choline PET/CT are used successfully for restaging prostate cancer in patients with bioc...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s12149-013-0731-7

    authors: Kitajima K,Murphy RC,Nathan MA

    更新日期:2013-08-01 00:00:00

  • Usefulness of a breath-holding acquisition method in PET/CT for pulmonary lesions.

    abstract:OBJECTIVE:To evaluate the usefulness of a breath-holding (BH) (18)F-2-fluoro-2-deoxy-D-glucose positron emission tomography ((18)F-FDG-PET) technique for PET/computed tomography (CT) scanning of pulmonary lesions near the diaphragm, where image quality is influenced by respiratory motion. METHODS:In a basic study, sim...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-008-0206-4

    authors: Yamaguchi T,Ueda O,Hara H,Sakai H,Kida T,Suzuki K,Adachi S,Ishii K

    更新日期:2009-01-01 00:00:00

  • The role of gallium-67 imaging in the detection of foci in recent cases of fever of unknown origin.

    abstract::We have assembled data from patients with fever of unknown origin who underwent gallium scintigraphy during the past 5 years in order to obtain a more current sampling of patients, and evaluated the role of gallium scintigraphy retrospectively. Of the 36 patients studied, gallium scintigraphy was positive and contribu...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164611

    authors: Suga K,Nakagi K,Kuramitsu T,Itou K,Tanaka N,Uchisato H,Nakanishi T,Utsumi H,Yamada N

    更新日期:1991-03-01 00:00:00

  • Analysis of thallium-201 myocardial SPECT images using fuzzy set theory.

    abstract::Using the fuzzy set theory, a method was developed for analyzing the extent and severity of ischemia by comparing the exercise and delayed SPECT images with Thallium-201. For each short axial image (slice) for exercise and delayed study, a defect probability matrix (DPM) is created so that it shows the severity of isc...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164947

    authors: Jamzad M,Uchiyama A,Toyama H,Murata H

    更新日期:1988-11-01 00:00:00

  • CT-based SPECT attenuation correction and assessment of infarct size: results from a cardiac phantom study.

    abstract:RATIONALE:Myocardial perfusion SPECT is a commonly performed, well established, clinically useful procedure for the management of patients with coronary artery disease. However, the attenuation of photons from myocardium impacts the quantification of infarct sizes. CT-Attenuation Correction (AC) potentially resolves th...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-017-1211-2

    authors: Kroiss AS,Nekolla SG,Dobrozemsky G,Grubinger T,Shulkin BL,Schwaiger M

    更新日期:2017-12-01 00:00:00

  • Normal uptake of F-18 FDG in the testis as assessed by PET/CT in a pediatric study population.

    abstract:OBJECTIVE:To investigate the correlation between the F-18 FDG uptake in the normal testis as assessed by PET-CT and patient age in a pediatric study population. METHODS:The study population consisted of 22 subjects aged between 9 and 17 years. For these subjects 42 PET-CT scans were available for analysis. The testis ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-009-0308-7

    authors: Goethals I,De Vriendt C,Hoste P,Smeets P,Ham H

    更新日期:2009-11-01 00:00:00

  • Left ventricular systolic/diastolic function evaluated by quantitative ECG-gated SPECT: comparison with echocardiography and plasma BNP analysis.

    abstract:OBJECTIVE:The aim of this study was to evaluate the left ventricular (LV) functional parameters calculated using quantitative electrocardiography (ECG)-gated myocardial perfusion single photon emission computed tomography (QGS). In addition to LV systolic parameters, diastolic parameters were compared with those by ult...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02985571

    authors: Nakae I,Matsuo S,Koh T,Mitsunami K,Horie M

    更新日期:2005-09-01 00:00:00

  • Performance assessment of the ALBIRA II pre-clinical SPECT S102 system for 99mTc imaging.

    abstract:OBJECTIVE:The performance characteristics of the SPECT sub-system S102 of the ALBIRA II PET/SPECT/CT are analyzed for the 80 mm field of view (FOV) to evaluate the potential in-vivo imaging in rats, based on measurements of the system response for the commonly used Technetium-99 m (99mTc) in small animal imaging. METH...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01547-7

    authors: Attarwala AA,Hardiansyah D,Romanó C,Jiménez-Franco LD,Roscher M,Wängler B,Glatting G

    更新日期:2021-01-01 00:00:00

  • Semiquantitative analysis of C-11 methionine PET may distinguish brain tumor recurrence from radiation necrosis even in small lesions.

    abstract:OBJECTIVE:(11)C-Methionine positron emission tomography (MET-PET) has been used to distinguish brain tumor recurrence from radiation necrosis. Because the spatial resolution of conventional PET scanners is low, partial volume effect (PVE) may decrease the detectability of small tumor recurrence. The aim of this study i...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-010-0450-2

    authors: Okamoto S,Shiga T,Hattori N,Kubo N,Takei T,Katoh N,Sawamura Y,Nishijima K,Kuge Y,Tamaki N

    更新日期:2011-04-01 00:00:00

  • Evaluation of the effects of chemotherapy on brain glucose metabolism in children with Hodgkin's lymphoma.

    abstract:OBJECTIVE:Chemobrain is a recently proposed pathological entity. 18F-FDG PET/CT can show objective abnormalities to explain brain disorders caused by chemotherapy, although no study has investigated these phenomena in children to date. The main objective of the present study was to examine quantitatively the effects of...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-019-01363-8

    authors: Tauty A,Noblet V,Paillard C,Fornecker LM,Namer IJ,Bund C

    更新日期:2019-08-01 00:00:00

  • Distinctive FDG and FES accumulation pattern of two tamoxifen-treated patients with endometrial hyperplasia.

    abstract::16alpha-[(18)F]Fluoro-17beta-estradiol (FES) is an estrogen receptor (ER) ligand used for the detection of ER-positive malignant tumors such as breast cancer. We recently reported the feasibility of combined FES-and 2-[(18)F]fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) scans for the differential d...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-007-0075-2

    authors: Tsujikawa T,Okazawa H,Yoshida Y,Mori T,Kobayashi M,Tsuchida T,Fujibayashi Y

    更新日期:2008-01-01 00:00:00

  • Scatter correction on its own increases image contrast in Tl-201 myocardium perfusion scintigraphy, but does it also improve diagnostic accuracy?

    abstract:UNLABELLED:Poor and variable spatial resolution of the gamma camera, the movement of the heart and, above all, the inclusion of scattered photons in the acquisition data contribute to the deterioration of image contrast in 201Tl myocardium perfusion studies. Scatter correction algorithms may correct for the latter fact...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02984983

    authors: Blokland KJ,de Vos tot Nederveen Cappel WH,van Eck-Smit BL,Pauwels EK

    更新日期:2003-12-01 00:00:00

  • Whole-body iodine-131 metaiodobenzylguanidine imaging for detection of bone metastases in patients with paraganglioma: comparison with bone scintigraphy.

    abstract::Iodine-131 metaiodobenzylguanidine ((131)I-MIBG) therapy is an effective treatment for patients with malignant paraganglioma for which surgical resection is not indicated. We performed high-dose (131)I-MIBG therapy on two patients with malignant paraganglioma and multiple bone metastases. The bone metastases were diag...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-007-0020-4

    authors: Inoue T,Yoshinaga K,Morita K,Shiga T,Kanegae K,Hirata K,Okamoto S,Tamaki N

    更新日期:2007-07-01 00:00:00

  • Paradigm shift in theranostics of neuroendocrine tumors: conceptual horizons of nanotechnology in nuclear medicine.

    abstract::We present a comprehensive review of Neuroendocrine Tumors (NET) and the current and developing imaging and therapeutic modalities for NET with emphasis on Nuclear Medicine modalities. Subsequently, nanotechnology and its emerging role in cancer management, especially NET, are discussed. The article is both educative ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s12149-018-1235-2

    authors: Arora G,Bandopadhyaya G

    更新日期:2018-04-01 00:00:00

  • Performance profile of FDG-PET and PET/CT for cancer screening on the basis of a Japanese Nationwide Survey.

    abstract:OBJECTIVE:The aim of this study is to survey the situation of (18)F-fluorodeoxyglucose-positron emission tomography (FDG-PET) cancer screening in Japan and to describe its performance profile. METHODS:"FDG-PET for cancer screening" was defined as FDG-PET or positron emission tomography and computed tomography (PET/CT)...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s12149-007-0061-8

    authors: Minamimoto R,Senda M,Uno K,Jinnouchi S,Iinuma T,Ito K,Okuyama C,Oguchi K,Kawamoto M,Suzuki Y,Tsukamoto E,Terauchi T,Nakashima R,Nishio M,Nishizawa S,Fukuda H,Yoshida T,Inoue T

    更新日期:2007-11-01 00:00:00

  • A novel respiratory gating method for oncologic positron emission tomography based on bioimpedance approach.

    abstract:OBJECTIVE:Respiratory motion causes loss of image quality and inaccuracy of quantification in oncologic positron emission tomography (PET) imaging. This study introduces a bioimpedance-based gating method for compensation of respiratory motion artefacts. METHODS:The bioimpedance-based respiratory gating method was stu...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-015-0953-y

    authors: Koivumäki T,Teuho J,Teräs M,Vauhkonen M,Hakulinen MA

    更新日期:2015-05-01 00:00:00

  • The usefulness of (18)F-FDG PET/MRI fusion image in diagnosing pancreatic tumor: comparison with (18)F-FDG PET/CT.

    abstract:PURPOSE:This study aimed at demonstrating the feasibility of retrospectively fused (18)F FDG-PET and MRI (PET/MRI fusion image) in diagnosing pancreatic tumor, in particular differentiating malignant tumor from benign lesions. In addition, we evaluated additional findings characterizing pancreatic lesions by FDG-PET/MR...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-013-0719-3

    authors: Nagamachi S,Nishii R,Wakamatsu H,Mizutani Y,Kiyohara S,Fujita S,Futami S,Sakae T,Furukoji E,Tamura S,Arita H,Chijiiwa K,Kawai K

    更新日期:2013-07-01 00:00:00

  • Unsuccessful tracer injection in radionuclide cisternography revisited.

    abstract::Since cerebrospinal fluid (CSF) leakage is highlighted as a cause of persistent headache, radionuclide cisternography has been increasingly performed in Japan to confirm the disorder, although the limited ability of the examination should be recognized. We present 3 cases in which failure of a tracer injection was str...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02984653

    authors: Horikoshi T,Asari Y,Watanabe A,Uchida M,Umeda T,Kolzumi H,Kinouchi H

    更新日期:2006-05-01 00:00:00

  • Correction of scattered photons in Tc-99m imaging by means of a photopeak dual-energy window acquisition.

    abstract::We are proposing a new method for correcting of scattered photons in technetium-99m (99mTc) imaging by means of photopeak dual-energy window acquisition. This method consists of the simultaneous acquisition of two images and estimation of a scatter image included in the symmetric energy window (SW) image by the differ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178307

    authors: Kojima A,Tsuji A,Takaki Y,Tomiguchi S,Hara M,Matsumoto M,Takahashi M

    更新日期:1992-08-01 00:00:00