Study on the lower limit of indoor humidity subject experiments on psychological responses.

Abstract:

:As a basis for determining the lower limit of acceptable humidity in an indoor environment, experiments were conducted for 25 subjects to assess the maximum expected sensations of dryness, discomfort based on humidity, and intolerance based on humidity, under conditions of 26°C and 10% RH. As results, distinct negative evaluations (dry, uncomfortable, or intolerable) were not obtained as the majority response; however, a small number of subjects declared distinct negative responses. In addition to the whole-body evaluation, the sensations for individual body parts were collected and found to be more intense for the eyes, nose, throat, and lips than for the other body parts. Significant differences between the genders were not found. For 8 of the subjects, similar experiments under a condition of 30% RH were conducted, and the difference between two humidity conditions was clearer for discomfort and intolerance than for dryness. The results suggest that the evaluation of the specific individuals who respond intensely, the consideration of intense responses for a specific part of the body, and the careful selection of an evaluation word for a psychological response might be effective to link this study to the determination of the lower limit of indoor humidity.

journal_name

Indoor Air

journal_title

Indoor air

authors

Takada S

doi

10.1111/ina.12717

subject

Has Abstract

pub_date

2021-01-01 00:00:00

pages

250-263

issue

1

eissn

0905-6947

issn

1600-0668

journal_volume

31

pub_type

杂志文章
  • Effectiveness of a portable air cleaner in removing aerosol particles in homes close to highways.

    abstract::Outdoor traffic-related airborne particles can infiltrate a building and adversely affect the indoor air quality. Limited information is available on the effectiveness of high efficiency particulate air (HEPA) filtration of traffic-related particles. Here, we investigated the effectiveness of portable HEPA air cleaner...

    journal_title:Indoor air

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/ina.12502

    authors: Cox J,Isiugo K,Ryan P,Grinshpun SA,Yermakov M,Desmond C,Jandarov R,Vesper S,Ross J,Chillrud S,Dannemiller K,Reponen T

    更新日期:2018-11-01 00:00:00

  • Experimental study of ventilation performance and contaminant distribution of underfloor ventilation systems vs. traditional ceiling-based ventilation system.

    abstract:UNLABELLED:Ventilation performance and pollutant distribution in a traditional ceiling-type ventilation system, a top-return (TR)-type and a floor-return (FR)-type underfloor ventilation systems were performed in a controlled experimental room. Tracer gas method was utilized to determine the age of air and the contamin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00248.x

    authors: Chao CY,Wan MP

    更新日期:2004-10-01 00:00:00

  • Quantitative aerobiologic analysis of an influenza human challenge-transmission trial.

    abstract::Despite evidence that airborne transmission contributes to influenza epidemics, limited knowledge of the infectiousness of human influenza cases hinders pandemic preparedness. We used airborne viral source strength and indoor CO2 monitoring from the largest human influenza challenge-transmission trial (EMIT: Evaluatin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12701

    authors: Bueno de Mesquita PJ,Noakes CJ,Milton DK

    更新日期:2020-11-01 00:00:00

  • Exercise-induced effects on a gym atmosphere.

    abstract::We report results of analysis of a month-long measurement of indoor air and environment quality parameters in one gym during sporting activities such as football, basketball, volleyball, badminton, boxing, and fitness. We have determined an average single person's contribution to the increase of temperature, humidity,...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12226

    authors: Žitnik M,Bučar K,Hiti B,Barba Ž,Rupnik Z,Založnik A,Žitnik E,Rodrìguez L,Mihevc I,Žibert J

    更新日期:2016-06-01 00:00:00

  • Measured concentrations of combustion gases from the use of unvented gas fireplaces.

    abstract:UNLABELLED:Measurements of combustion product concentrations were taken in 30 homes where unvented gas fireplaces were used. Measurements of CO, CO(2), NO(x), NO(2) , O(2) (depletion), and water vapor were taken at 1-min interval. The analyzers were calibrated with certified calibration gases for each placement and wer...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00659.x

    authors: Francisco PW,Gordon JR,Rose B

    更新日期:2010-10-01 00:00:00

  • The field comparison of three measuring techniques for evaluation of the surface dust level in ventilation ducts.

    abstract::This paper reports the comparison of three measuring methods for quantifying the amount of dust on the inner surface of ventilation ducts: 1) a vacuum test method; 2) a gravimetric tape method; and 3) an optical method. Thirteen recently constructed buildings were selected for the field test in the Helsinki metropolit...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.120106.x

    authors: Holopainen R,Asikainen V,Pasanen P,Seppänen O

    更新日期:2002-03-01 00:00:00

  • Formaldehyde as a basis for residential ventilation rates.

    abstract::Traditionally, houses in the US have been ventilated by passive infiltration in combination with active window opening. However in recent years, the construction quality of residential building envelopes has been improved to reduce infiltration, and the use of windows for ventilation also may have decreased due to a n...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1046/j.1600-0668.2003.00188.x

    authors: Sherman MH,Hodgson AT

    更新日期:2004-02-01 00:00:00

  • Pollutant dispersion in a large indoor space. Part 2: Computational fluid dynamics predictions and comparison with a scale model experiment for isothermal flow.

    abstract:UNLABELLED:This paper reports on an investigation of the adequacy of computational fluid dynamics (CFD), using a standard Reynolds Averaged Navier-Stokes (RANS) model, for predicting dispersion of neutrally buoyant gas in a large indoor space. We used CFD to predict pollutant (dye) concentration distribution in a water...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00243.x

    authors: Finlayson EU,Gadgil AJ,Thatcher TL,Sextro RG

    更新日期:2004-08-01 00:00:00

  • Machine learning and statistical models for predicting indoor air quality.

    abstract::Indoor air quality (IAQ), as determined by the concentrations of indoor air pollutants, can be predicted using either physically based mechanistic models or statistical models that are driven by measured data. In comparison with mechanistic models mostly used in unoccupied or scenario-based environments, statistical m...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/ina.12580

    authors: Wei W,Ramalho O,Malingre L,Sivanantham S,Little JC,Mandin C

    更新日期:2019-09-01 00:00:00

  • Benefit-cost analysis of commercially available activated carbon filters for indoor ozone removal in single-family homes.

    abstract::This study involved the development of a model for evaluating the potential costs and benefits of ozone control by activated carbon filtration in single-family homes. The modeling effort included the prediction of indoor ozone with and without activated carbon filtration in the HVAC system. As one application, the mod...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12220

    authors: Aldred JR,Darling E,Morrison G,Siegel J,Corsi RL

    更新日期:2016-06-01 00:00:00

  • Association of size-fractionated indoor particulate matter and black carbon with heart rate variability in healthy elderly women in Beijing.

    abstract::Associations between size-fractionated indoor particulate matter (PM) and black carbon (BC) and heart rate variability (HRV) and heart rate (HR) in elderly women remain unclear. Twenty-nine healthy elderly women were measured for 24-hour HRV/HR indices. Real-time size-fractionated indoor PM and BC were monitored on th...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12449

    authors: Dong W,Pan L,Li H,Miller MR,Loh M,Wu S,Xu J,Yang X,Shan J,Chen Y,Deng F,Guo X

    更新日期:2018-05-01 00:00:00

  • Sorptive interactions between VOCs and indoor materials.

    abstract::This study was carried out using various materials (carpet, gypsum board, upholstery, vinyl and wood flooring, acoustic tiles, and fruit) that were exposed to eight gaseous volatile organic compounds (VOCs) (isopropanol, MTBE, cyclohexane, toluene, ethylbenzene, tetrachloroethene, 1,2-dichlorobenzene, and 1,2,4-trichl...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.110406.x

    authors: Won D,Corsi RL,Rynes M

    更新日期:2001-12-01 00:00:00

  • Particulate matter from indoor environments of classroom induced higher cytotoxicity and leakiness in human microvascular endothelial cells in comparison with those collected from corridor.

    abstract::We investigated the physicochemical properties (size, shape, elemental composition, and endotoxin) of size resolved particulate matter (PM) collected from the indoor and corridor environments of classrooms. A comparative hazard profiling of these PM was conducted using human microvascular endothelial cells (HMVEC). Ox...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12341

    authors: Chua ML,Setyawati MI,Li H,Fang CHY,Gurusamy S,Teoh FTL,Leong DT,George S

    更新日期:2017-05-01 00:00:00

  • Identification of contaminant sources in enclosed environments by inverse CFD modeling.

    abstract:UNLABELLED:In case contaminants are found in enclosed environments such as aircraft cabins or buildings, it is useful to find the contaminant sources. One method to locate contaminant sources is by inverse computational fluid dynamics (CFD) modeling. As the inverse CFD modeling is ill posed, this paper has proposed to ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00452.x

    authors: Zhang TF,Chen Q

    更新日期:2007-06-01 00:00:00

  • Respiratory effects of experimental exposure to office dust.

    abstract:UNLABELLED:The aim of this experiment was to test if healthy persons respond to exposures to normal office dust with objective or subjective effects in a dose-related way. If they did, the importance of their personal characteristics should be investigated. This paper presents the results related to respiratory effects...

    journal_title:Indoor air

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1600-0668.2004.00252.x

    authors: Mølhave L,Kjaergaard SK,Attermann J

    更新日期:2004-12-01 00:00:00

  • A simplified approach to describe complex diffusers in displacement ventilation for CFD simulations.

    abstract:UNLABELLED:With the capability to improve indoor air quality while simultaneously reducing energy demand, displacement ventilation is becoming popular. However, the numerical simulation of air distribution in an indoor space with displacement ventilation using computational fluid dynamics (CFD) is challenging because o...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2009.00590.x

    authors: Zhang TT,Lee K,Chen QY

    更新日期:2009-06-01 00:00:00

  • Stability of airborne microbes in the Louvre Museum over time.

    abstract::The microbial content of air has as yet been little described, despite its public health implications, and there remains a lack of environmental microbial data on airborne microflora in enclosed spaces. In this context, the aim of this study was to characterize the diversity and dynamics of airborne microorganisms in ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12053

    authors: Gaüzère C,Moletta-Denat M,Blanquart H,Ferreira S,Moularat S,Godon JJ,Robine E

    更新日期:2014-02-01 00:00:00

  • Influence of local airflow on the pollutant emission from indoor building surfaces.

    abstract::This article reports the results of an investigation, based on fundamental fluid dynamics and mass transfer theory, carried out to obtain a general understanding of the mechanisms involved in the emissions from building materials in ventilated rooms. In addition, a generally applicable method for the prediction of sur...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.011003162.x

    authors: Topp C,Nielsen PV,Heiselberg P

    更新日期:2001-09-01 00:00:00

  • Building-related symptoms and inflammatory potency of dust from office buildings.

    abstract:UNLABELLED:The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings received a retrospective ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00493.x

    authors: Allermann L,Pejtersen J,Gunnarsen L,Poulsen OM

    更新日期:2007-12-01 00:00:00

  • Characterization of particulate emissions from occupant activities in offices.

    abstract::This paper characterizes the relationship between occupant activities and indoor air particulate levels in a non-smoking office building. Occupant activities were recorded on video. Particulate concentrations were monitored by three optical particle counters (OPCs) in five size ranges at three heights. Particulate mas...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.011001035.x

    authors: Luoma M,Batterman SA

    更新日期:2001-03-01 00:00:00

  • Humidity control effect of vapor-permeable walls employing hygroscopic insulation material.

    abstract::Airtight construction and high-performance thermal insulation materials are commonly considered important building features to enhance indoor thermal comfort while reducing thermal load. However, when water vapor is generated in such airtight indoor spaces, it cannot be discharged to the outside, causing interstitial ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12622

    authors: Lee H,Ozaki A,Lee M,Yamamoto T

    更新日期:2020-03-01 00:00:00

  • Chemistry in indoor environments: 20 years of research.

    abstract:UNLABELLED:In the two decades since the first issue of Indoor Air, there have been over 250 peer-reviewed publications addressing chemical reactions among indoor pollutants. The present review has assembled and categorized these publications. It begins with a brief account of the state of our knowledge in 1991 regardin...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2011.00713.x

    authors: Weschler CJ

    更新日期:2011-06-01 00:00:00

  • Cooking fuel type, household ventilation, and the risk of acute lower respiratory illness in urban Bangladeshi children: a longitudinal study.

    abstract:UNLABELLED:Acute lower respiratory illnesses (ALRI) are the leading cause of death among children <5 years. Studies have found that biomass cooking fuels are an important risk factor for ALRI. However, few studies have evaluated the influence of natural household ventilation indicators on ALRI. The purpose of this stud...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00754.x

    authors: Murray EL,Brondi L,Kleinbaum D,McGowan JE,Van Mels C,Brooks WA,Goswami D,Ryan PB,Klein M,Bridges CB

    更新日期:2012-04-01 00:00:00

  • Droplet fate in indoor environments, or can we prevent the spread of infection?

    abstract:UNLABELLED:When considering how people are infected and what can be done to prevent the infections, answers from many disciplines are sought: microbiology, epidemiology, medicine, engineering, and physics. There are many pathways to infection spread, and among the most significant from the epidemiological point of view...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2006.00432.x

    authors: Morawska L

    更新日期:2006-10-01 00:00:00

  • Continuous measurement of reactive oxygen species inside and outside of a residential house during summer.

    abstract::Reactive oxygen species (ROS) are an important contributor to adverse health effects associated with ambient air pollution. Despite infiltration of ROS from outdoors, and possible indoor sources (eg, combustion), there are limited data available on indoor ROS. In this study, part of the second phase of Air Composition...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12789

    authors: Eftekhari A,Fortenberry CF,Williams BJ,Walker MJ,Dang A,Pfaff A,Ercal N,Morrison GC

    更新日期:2021-01-23 00:00:00

  • Characterization of endotoxin and 3-hydroxy fatty acid levels in air and settled dust from commercial aircraft cabins.

    abstract::Endotoxin was measured in air and dust samples collected during four commercial aircraft flights. Samples were analyzed for endotoxin biological activity using the Limulus assay. 3-hydroxy fatty acids (3-OH FA) of carbon chain lengths C10:0-C18:0 were determined in dust by gas chromatography-ion trap tandem mass spect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00175.x

    authors: Hines CJ,Waters MA,Larsson L,Petersen MR,Saraf A,Milton DK

    更新日期:2003-06-01 00:00:00

  • Measured moisture in buildings and adverse health effects: A review.

    abstract::It has not yet been possible to quantify dose-related health risks attributable to indoor dampness or mold (D/M), to support setting specific health-related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of q...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/ina.12464

    authors: Mendell MJ,Macher JM,Kumagai K

    更新日期:2018-07-01 00:00:00

  • Endotoxin, extracellular polysaccharides, and β(1-3)-glucan concentrations in dust and their determinants in four European birth cohorts: results from the HITEA project.

    abstract:UNLABELLED:Early-life exposure to microbial agents may play a protective role in asthma and allergies development. Geographical differences in the prevalence of these diseases exist, but the differences in early-life indoor microbial agent levels and their determinants have been hardly studied. We aimed to describe the...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12017

    authors: Casas L,Tischer C,Wouters IM,Valkonen M,Gehring U,Doekes G,Torrent M,Pekkanen J,Garcia-Esteban R,Hyvärinen A,Heinrich J,Sunyer J

    更新日期:2013-06-01 00:00:00

  • Relationships between estimated flame retardant emissions and levels in indoor air and house dust.

    abstract::A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12332

    authors: Liagkouridis I,Cequier E,Lazarov B,Palm Cousins A,Thomsen C,Stranger M,Cousins IT

    更新日期:2017-05-01 00:00:00

  • Organic compounds as indicators of air pollution.

    abstract::The most important indoor air pollutants have already been addressed with individual national guidelines or recommendations. However, an international set of guidelines or recommendations for indoor air quality (IAQ) is needed for these pollutants based on general and uniform rules for setting such standards. A major ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.13.s.6.2.x

    authors: Mølhave L

    更新日期:2003-01-01 00:00:00