Measured concentrations of combustion gases from the use of unvented gas fireplaces.

Abstract:

UNLABELLED:Measurements of combustion product concentrations were taken in 30 homes where unvented gas fireplaces were used. Measurements of CO, CO(2), NO(x), NO(2) , O(2) (depletion), and water vapor were taken at 1-min interval. The analyzers were calibrated with certified calibration gases for each placement and were in operation for 3-4 days at each home. Measured concentrations were compared to published health-based standards and guidelines. The two combustion gases that exceeded published values were NO(2) and CO. For NO(2) , the Health Canada guideline of 250 ppb (1-h average) was exceeded in about 43% of the sample and the World Health Organization (WHO) guideline of 110 ppb (1-h average) was exceeded in 80% of the sample. Carbon monoxide levels exceeded the U.S. EPA 8-h average standard of 9 ppm in 20% of the sample. Moisture problems were not evident in the test homes. An analysis of the distribution of CO showed that the CO is dispersed throughout the home almost immediately upon operation of the fireplace and that the concentrations throughout the home away from the immediate vicinity of the fireplace are 70-80% of the level near the fireplace. Decay analysis of the combustion gases showed that NO was similarly stable to CO and CO(2) in the indoor environment but that both NO(2) and water vapor were removed from the air at much greater rates. PRACTICAL IMPLICATIONS:Previous studies on unvented gas fireplaces have made assumptions of how they are operated by users. This article presents the results of field monitoring of 30 unvented gas fireplaces under normal operation, regardless of whether users follow industry recommendations regarding installation, usage patterns, and maintenance. The monitoring found that health-based standards and guidelines were exceeded for CO in 20% of homes and for NO(2) in most homes. There were no identified moisture problems in these homes. Nearly, half of the fireplaces were used at least once for longer than 2 h, counter to manufacturers' intended usage as supplemental heating. This demonstrates that given actual usage patterns and compared to current health-based thresholds, these appliances can produce indoor air concentrations considered to be unhealthy to at least sensitive or at-risk individuals.

journal_name

Indoor Air

journal_title

Indoor air

authors

Francisco PW,Gordon JR,Rose B

doi

10.1111/j.1600-0668.2010.00659.x

subject

Has Abstract

pub_date

2010-10-01 00:00:00

pages

370-9

issue

5

eissn

0905-6947

issn

1600-0668

pii

INA659

journal_volume

20

pub_type

杂志文章
  • Subjective perceptions, symptom intensity and performance: a comparison of two independent studies, both changing similarly the pollution load in an office.

    abstract::The present paper shows that introducing or removing the same pollution source in an office in two independent investigations, one in Denmark and one in Sweden, using similar experimental methodology, resulted in similar and repeatable effects on subjective assessments of perceived air quality, intensity of sick build...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.01101.x

    authors: Wargocki P,Lagercrantz L,Witterseh T,Sundell J,Wyon DP,Fanger PO

    更新日期:2002-06-01 00:00:00

  • Measuring the exposure of infants and children to indoor air pollution from biomass fuels in The Gambia.

    abstract:UNLABELLED:Indoor air pollution (IAP) from biomass fuels contains high concentrations of health damaging pollutants and is associated with an increased risk of childhood pneumonia. We aimed to design an exposure measurement component for a matched case-control study of IAP as a risk factor for pneumonia and severe pneu...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00533.x

    authors: Dionisio KL,Howie S,Fornace KM,Chimah O,Adegbola RA,Ezzati M

    更新日期:2008-08-01 00:00:00

  • Airborne particle emission of a commercial 3D printer: the effect of filament material and printing temperature.

    abstract::The knowledge of exposure to the airborne particle emitted from three-dimensional (3D) printing activities is becoming a crucial issue due to the relevant spreading of such devices in recent years. To this end, a low-cost desktop 3D printer based on fused deposition modeling (FDM) principle was used. Particle number, ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12310

    authors: Stabile L,Scungio M,Buonanno G,Arpino F,Ficco G

    更新日期:2017-03-01 00:00:00

  • Assessment through environmental and biological measurements of total daily exposure to volatile organic compounds of office workers in Milan, Italy.

    abstract::Personal exposure to total volatile organic compounds (TVOCs), benzene and toluene of 100 Milan office workers was assessed through personal air monitoring at home, in the office, and during commuting. Biological monitoring was performed by measuring blood benzene and toluene concentrations together with urinary trans...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2000.010004258.x

    authors: Carrer P,Maroni M,Alcini D,Cavallo D,Fustinoni S,Lovato L,Visigalli F

    更新日期:2000-12-01 00:00:00

  • Indoor air pollution in developing countries: recommendations for research.

    abstract::Available studies indicate that indoor air pollution (IAP) from household cooking and space heating apparently causes substantial ill-health in developing countries where the majority of households rely on solid fuels (coal or biomass as wood, crop residues, and dung), but there are many remaining uncertainties. To pi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.01137.x

    authors: Smith KR

    更新日期:2002-09-01 00:00:00

  • Human convection flow in spaces with and without ventilation: personal exposure to floor-released particles and cough-released droplets.

    abstract:UNLABELLED:The effects of the human convective boundary layer (CBL), room airflow patterns, and their velocities on personal exposure are examined. Two pollutants are studied which simulate particles released from the feet and generated at distances of 2 and 3 m by a human cough. A thermal manikin whose body shape, siz...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12177

    authors: Licina D,Melikov A,Pantelic J,Sekhar C,Tham KW

    更新日期:2015-12-01 00:00:00

  • Survey of the reliability of carbon monoxide alarms deployed in domestic homes and efficacy of use by consumers.

    abstract::Carbon monoxide (CO) alarms are extensively used in domestic premises in the UK to help protect against CO poisoning. Their expected lifetime has been increasing, and some current models now have a replacement period of more than 6 years under normal operation. However, concerns have been expressed as to the reliabili...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12022

    authors: Naylor S,Walsh PT,Dowker KP

    更新日期:2013-08-01 00:00:00

  • Use of a robotic sampling platform to assess young children's exposure to indoor bioaerosols.

    abstract:UNLABELLED:Indoor exposures to allergens, mold spores, and endotoxin have been suggested as etiological agents of asthma; therefore, accurate determination of those exposures, especially in young children (6-36 months), is important for understanding the development of asthma. Because use of personal sampling equipment...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00749.x

    authors: Wang Z,Shalat SL,Black K,Lioy PJ,Stambler AA,Emoekpere OH,Hernandez M,Han T,Ramagopal M,Mainelis G

    更新日期:2012-04-01 00:00:00

  • Biomass fuel smoke exposure was associated with adverse cardiac remodeling and left ventricular dysfunction in Peru.

    abstract::While household air pollution from biomass fuel combustion has been linked to cardiovascular disease, the effects on cardiac structure and function have not been well described. We sought to determine the association between biomass fuel smoke exposure and cardiac structure and function by transthoracic echocardiograp...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12362

    authors: Burroughs Peña MS,Velazquez EJ,Rivera JD,Alenezi F,Wong C,Grigsby M,Davila-Roman VG,Gilman RH,Miranda JJ,Checkley W

    更新日期:2017-07-01 00:00:00

  • Benefit-cost analysis of commercially available activated carbon filters for indoor ozone removal in single-family homes.

    abstract::This study involved the development of a model for evaluating the potential costs and benefits of ozone control by activated carbon filtration in single-family homes. The modeling effort included the prediction of indoor ozone with and without activated carbon filtration in the HVAC system. As one application, the mod...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12220

    authors: Aldred JR,Darling E,Morrison G,Siegel J,Corsi RL

    更新日期:2016-06-01 00:00:00

  • Collection efficiency of liquid-based samplers for fungi in indoor air.

    abstract::This study assessed the collection efficiency (CE) of two popularly used sampling devices (BioSampler and Coriolis sampler) for fungal aerosols. Phosphate-buffered saline (PBS) supplemented with or without surfactant (Tween-20, Tween-80, or Triton X-100) and antifoam agent was prepared and used as collection liquids. ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12535

    authors: Chang CW,Ting YT,Horng YJ

    更新日期:2019-05-01 00:00:00

  • Organic compounds as indicators of air pollution.

    abstract::The most important indoor air pollutants have already been addressed with individual national guidelines or recommendations. However, an international set of guidelines or recommendations for indoor air quality (IAQ) is needed for these pollutants based on general and uniform rules for setting such standards. A major ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.13.s.6.2.x

    authors: Mølhave L

    更新日期:2003-01-01 00:00:00

  • Pollutant dispersion in a large indoor space. Part 2: Computational fluid dynamics predictions and comparison with a scale model experiment for isothermal flow.

    abstract:UNLABELLED:This paper reports on an investigation of the adequacy of computational fluid dynamics (CFD), using a standard Reynolds Averaged Navier-Stokes (RANS) model, for predicting dispersion of neutrally buoyant gas in a large indoor space. We used CFD to predict pollutant (dye) concentration distribution in a water...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00243.x

    authors: Finlayson EU,Gadgil AJ,Thatcher TL,Sextro RG

    更新日期:2004-08-01 00:00:00

  • Comparison of risk factor profiles concerning self-reported skin complaints and objectively determined skin symptoms in German office workers.

    abstract::The correspondence between impact factor profiles of self-reported skin sensation and of objectively determined skin symptoms was examined using data from the ProKlimA project (1994-1999). A sub-sample of 925 office workers participated in measurements of skin hydration and sebum content and responded to a questionnai...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1046/j.1600-0668.2003.00222.x

    authors: Brasche S,Bullinger M,Schwab R,Gebhardt H,Herzog V,Bischof W

    更新日期:2004-04-01 00:00:00

  • Early age exposure to moisture damage and systemic inflammation at the age of 6 years.

    abstract::Cross-sectional studies have shown that exposure to indoor moisture damage and mold may be associated with subclinical inflammation. Our aim was to determine whether early age exposure to moisture damage or mold is prospectively associated with subclinical systemic inflammation or with immune responsiveness in later c...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12454

    authors: Karvonen AM,Tischer C,Kirjavainen PV,Roponen M,Hyvärinen A,Illi S,Mustonen K,Pfefferle PI,Renz H,Remes S,Schaub B,von Mutius E,Pekkanen J

    更新日期:2018-05-01 00:00:00

  • Stability of airborne microbes in the Louvre Museum over time.

    abstract::The microbial content of air has as yet been little described, despite its public health implications, and there remains a lack of environmental microbial data on airborne microflora in enclosed spaces. In this context, the aim of this study was to characterize the diversity and dynamics of airborne microorganisms in ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12053

    authors: Gaüzère C,Moletta-Denat M,Blanquart H,Ferreira S,Moularat S,Godon JJ,Robine E

    更新日期:2014-02-01 00:00:00

  • The field comparison of three measuring techniques for evaluation of the surface dust level in ventilation ducts.

    abstract::This paper reports the comparison of three measuring methods for quantifying the amount of dust on the inner surface of ventilation ducts: 1) a vacuum test method; 2) a gravimetric tape method; and 3) an optical method. Thirteen recently constructed buildings were selected for the field test in the Helsinki metropolit...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.120106.x

    authors: Holopainen R,Asikainen V,Pasanen P,Seppänen O

    更新日期:2002-03-01 00:00:00

  • Polybrominated diphenyl ether (PBDE) concentrations and resulting exposure in homes in California: relationships among passive air, surface wipe and dust concentrations, and temporal variability.

    abstract::Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12130

    authors: Bennett DH,Moran RE,Wu XM,Tulve NS,Clifton MS,Colón M,Weathers W,Sjödin A,Jones R,Hertz-Picciotto I

    更新日期:2015-04-01 00:00:00

  • Modeling the internal dynamics of energy and mass transfer in an imperfectly mixed ventilated airspace.

    abstract:UNLABELLED:The present paper outlines a modeling approach, which has been developed to model the internal dynamics of heat and moisture transfer in an imperfectly mixed ventilated airspace. The modeling approach, which combines the classical heat and moisture balance differential equations with the use of experimental ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00168.x

    authors: Janssens K,Van Brecht A,Zerihun Desta T,Boonen C,Berckmans D

    更新日期:2004-06-01 00:00:00

  • Effectiveness of a portable air cleaner in removing aerosol particles in homes close to highways.

    abstract::Outdoor traffic-related airborne particles can infiltrate a building and adversely affect the indoor air quality. Limited information is available on the effectiveness of high efficiency particulate air (HEPA) filtration of traffic-related particles. Here, we investigated the effectiveness of portable HEPA air cleaner...

    journal_title:Indoor air

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/ina.12502

    authors: Cox J,Isiugo K,Ryan P,Grinshpun SA,Yermakov M,Desmond C,Jandarov R,Vesper S,Ross J,Chillrud S,Dannemiller K,Reponen T

    更新日期:2018-11-01 00:00:00

  • Particle size distributions and concentrations of airborne endotoxin using novel collection methods in homes during the winter and summer seasons.

    abstract:UNLABELLED:A comparison study of novel collection methods for airborne bacteria and endotoxin was performed in an environmentally controlled chamber and in pilot-field studies. Airborne particulate matter was collected in swirling liquid impingers, air-monitoring filter cassettes, and with a micro-orifice uniform depos...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00419.x

    authors: Kujundzic E,Hernandez M,Miller SL

    更新日期:2006-06-01 00:00:00

  • Combined use of an electrostatic precipitator and a high-efficiency particulate air filter in building ventilation systems: Effects on cardiorespiratory health indicators in healthy adults.

    abstract::High-efficiency particulate air (HEPA) filtration in combination with an electrostatic precipitator (ESP) can be a cost-effective approach to reducing indoor particulate exposure, but ESPs produce ozone. The health effect of combined ESP-HEPA filtration has not been examined. We conducted an intervention study in 89 v...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12447

    authors: Day DB,Xiang J,Mo J,Clyde MA,Weschler CJ,Li F,Gong J,Chung M,Zhang Y,Zhang J

    更新日期:2018-05-01 00:00:00

  • Indoor thermal stratification and its statistical distribution.

    abstract::Thermal stratification is established when warmer air rises and cooler air descends under thermal buoyancy. It occurs in indoor environment situations including large warehouse-type buildings, buoyancy-driven ventilated spaces with displacement, underfloor ventilation, and/or natural ventilation, and enclosure fires w...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12520

    authors: Wang LL,Zhang X,Qi D

    更新日期:2019-03-01 00:00:00

  • Simulating the human body's microclimate using automatic coupling of CFD and an advanced thermoregulation model.

    abstract::This study aims to develop an approach to couple a computational fluid dynamics (CFD) solver to the University of California, Berkeley (UCB) thermal comfort model to accurately evaluate thermal comfort. The coupling was made using an iterative JavaScript to automatically transfer data for each individual segment of th...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12451

    authors: Voelker C,Alsaad H

    更新日期:2018-05-01 00:00:00

  • Cooking fuel type, household ventilation, and the risk of acute lower respiratory illness in urban Bangladeshi children: a longitudinal study.

    abstract:UNLABELLED:Acute lower respiratory illnesses (ALRI) are the leading cause of death among children <5 years. Studies have found that biomass cooking fuels are an important risk factor for ALRI. However, few studies have evaluated the influence of natural household ventilation indicators on ALRI. The purpose of this stud...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00754.x

    authors: Murray EL,Brondi L,Kleinbaum D,McGowan JE,Van Mels C,Brooks WA,Goswami D,Ryan PB,Klein M,Bridges CB

    更新日期:2012-04-01 00:00:00

  • Quantitative measurement of airborne cockroach allergen in New York City apartments.

    abstract:UNLABELLED:We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10-15 LPM in 19 New York City apartments in which an asthmatic child...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00728.x

    authors: Esposito WA,Chew GL,Correa JC,Chillrud SN,Miller RL,Kinney PL

    更新日期:2011-12-01 00:00:00

  • Comparing zonal and CFD model predictions of isothermal indoor airflows to experimental data.

    abstract::It is inappropriate to use the assumption of instantaneously well-mixed zones to model airflows and pollutant transport in large indoor spaces. We investigate two approaches for describing the details of airflows in large indoor spaces, for accuracy and suitability for integration with multi-zone infiltration models. ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00160.x

    authors: Mora L,Gadgil AJ,Wurtz E

    更新日期:2003-06-01 00:00:00

  • A review of ventilation and the quality of ventilation air.

    abstract::Ventilation is pivotal in terms of securing optimum indoor air quality. In addition, it also has a major impact on energy use in buildings. It is important, therefore, that the role and impact of ventilation is fully understood and that ventilation is employed efficiently. The purpose of this paper is to review these ...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1034/j.1600-0668.2000.010003193.x

    authors: Liddament MW

    更新日期:2000-09-01 00:00:00

  • Indoor organophosphate and polybrominated flame retardants in Tokyo.

    abstract:UNLABELLED:In Japan, organophosphate and polybrominated flame retardants are used in building materials and electric appliances to protect them from fire hazards. In this study, to identify the emission sources of these flame retardants to indoor air, the migration rates (flux) of organophosphate and polybrominated fla...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00442.x

    authors: Saito I,Onuki A,Seto H

    更新日期:2007-02-01 00:00:00

  • Ultrafine particles from electric appliances and cooking pans: experiments suggesting desorption/nucleation of sorbed organics as the primary source.

    abstract::Ultrafine particles are observed when metal surfaces, such as heating elements in electric appliances, or even empty cooking pans, are heated. The source of the particles has not been identified. We present evidence that particles >10 nm are not emitted directly from the heating elements or the metal surfaces. Using r...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12163

    authors: Wallace LA,Ott WR,Weschler CJ

    更新日期:2015-10-01 00:00:00