A review of ventilation and the quality of ventilation air.

Abstract:

:Ventilation is pivotal in terms of securing optimum indoor air quality. In addition, it also has a major impact on energy use in buildings. It is important, therefore, that the role and impact of ventilation is fully understood and that ventilation is employed efficiently. The purpose of this paper is to review these aspects with particular reference to recent research and developments. Key aspects are concerned with identifying the role of ventilation and reviewing this role in the context of the other measures that must be taken to secure a healthy indoor environment. References are particularly made to the development of standards and recent related research. Although good progress is being made, areas that still need to be addressed include maintaining good outdoor air quality and preventing contaminated outdoor air from entering buildings. The outcome of recent research must also be disseminated in practical ways to policy makers, building occupiers and practitioners. Good indoor climate can be achieved, not so much by introducing expensive concepts, but by developing a rationale approach to identifying needs and applying the necessary tools to deal with each need.

journal_name

Indoor Air

journal_title

Indoor air

authors

Liddament MW

doi

10.1034/j.1600-0668.2000.010003193.x

subject

Has Abstract

pub_date

2000-09-01 00:00:00

pages

193-9

issue

3

eissn

0905-6947

issn

1600-0668

journal_volume

10

pub_type

杂志文章,评审
  • The field comparison of three measuring techniques for evaluation of the surface dust level in ventilation ducts.

    abstract::This paper reports the comparison of three measuring methods for quantifying the amount of dust on the inner surface of ventilation ducts: 1) a vacuum test method; 2) a gravimetric tape method; and 3) an optical method. Thirteen recently constructed buildings were selected for the field test in the Helsinki metropolit...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.120106.x

    authors: Holopainen R,Asikainen V,Pasanen P,Seppänen O

    更新日期:2002-03-01 00:00:00

  • Indoor organophosphate and polybrominated flame retardants in Tokyo.

    abstract:UNLABELLED:In Japan, organophosphate and polybrominated flame retardants are used in building materials and electric appliances to protect them from fire hazards. In this study, to identify the emission sources of these flame retardants to indoor air, the migration rates (flux) of organophosphate and polybrominated fla...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00442.x

    authors: Saito I,Onuki A,Seto H

    更新日期:2007-02-01 00:00:00

  • Removal of viable bioaerosol particles with a low-efficiency HVAC filter enhanced by continuous emission of unipolar air ions.

    abstract:UNLABELLED:Continuous emission of unipolar ions has been shown to improve the performance of respirators and stationary filters challenged with non-biological particles. In this study, we investigated the ion-induced enhancement effect while challenging a low-efficiency heating, ventilation and air-conditioning (HVAC) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00512.x

    authors: Huang R,Agranovski I,Pyankov O,Grinshpun S

    更新日期:2008-04-01 00:00:00

  • Effects of energy retrofits on Indoor Air Quality in multifamily buildings.

    abstract::We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12555

    authors: Du L,Leivo V,Prasauskas T,Täubel M,Martuzevicius D,Haverinen-Shaughnessy U

    更新日期:2019-07-01 00:00:00

  • Building-related symptoms and inflammatory potency of dust from office buildings.

    abstract:UNLABELLED:The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings received a retrospective ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00493.x

    authors: Allermann L,Pejtersen J,Gunnarsen L,Poulsen OM

    更新日期:2007-12-01 00:00:00

  • Characterizing ultrafine particles and other air pollutants at five schools in South Texas.

    abstract:UNLABELLED:This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00738.x

    authors: Zhang Q,Zhu Y

    更新日期:2012-02-01 00:00:00

  • Endotoxin, extracellular polysaccharides, and β(1-3)-glucan concentrations in dust and their determinants in four European birth cohorts: results from the HITEA project.

    abstract:UNLABELLED:Early-life exposure to microbial agents may play a protective role in asthma and allergies development. Geographical differences in the prevalence of these diseases exist, but the differences in early-life indoor microbial agent levels and their determinants have been hardly studied. We aimed to describe the...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12017

    authors: Casas L,Tischer C,Wouters IM,Valkonen M,Gehring U,Doekes G,Torrent M,Pekkanen J,Garcia-Esteban R,Hyvärinen A,Heinrich J,Sunyer J

    更新日期:2013-06-01 00:00:00

  • Measured concentrations of combustion gases from the use of unvented gas fireplaces.

    abstract:UNLABELLED:Measurements of combustion product concentrations were taken in 30 homes where unvented gas fireplaces were used. Measurements of CO, CO(2), NO(x), NO(2) , O(2) (depletion), and water vapor were taken at 1-min interval. The analyzers were calibrated with certified calibration gases for each placement and wer...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00659.x

    authors: Francisco PW,Gordon JR,Rose B

    更新日期:2010-10-01 00:00:00

  • Measuring the exposure of infants and children to indoor air pollution from biomass fuels in The Gambia.

    abstract:UNLABELLED:Indoor air pollution (IAP) from biomass fuels contains high concentrations of health damaging pollutants and is associated with an increased risk of childhood pneumonia. We aimed to design an exposure measurement component for a matched case-control study of IAP as a risk factor for pneumonia and severe pneu...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00533.x

    authors: Dionisio KL,Howie S,Fornace KM,Chimah O,Adegbola RA,Ezzati M

    更新日期:2008-08-01 00:00:00

  • Ultrafine, fine, and black carbon particle concentrations in California child-care facilities.

    abstract::Although many U.S. children spend time in child care, little information exists on exposures to airborne particulate matter (PM) in this environment, even though PM may be associated with asthma and other respiratory illness, which is a key concern for young children. To address this data gap, we measured ultrafine pa...

    journal_title:Indoor air

    pub_type: 杂志文章,多中心研究

    doi:10.1111/ina.12408

    authors: Gaspar FW,Maddalena R,Williams J,Castorina R,Wang ZM,Kumagai K,McKone TE,Bradman A

    更新日期:2018-01-01 00:00:00

  • Biomass fuel smoke exposure was associated with adverse cardiac remodeling and left ventricular dysfunction in Peru.

    abstract::While household air pollution from biomass fuel combustion has been linked to cardiovascular disease, the effects on cardiac structure and function have not been well described. We sought to determine the association between biomass fuel smoke exposure and cardiac structure and function by transthoracic echocardiograp...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12362

    authors: Burroughs Peña MS,Velazquez EJ,Rivera JD,Alenezi F,Wong C,Grigsby M,Davila-Roman VG,Gilman RH,Miranda JJ,Checkley W

    更新日期:2017-07-01 00:00:00

  • Molds in floor dust and building-related symptoms among adolescent school children: a problem for boys only?

    abstract:UNLABELLED:In this stratified cross-sectional study in eight 'wet' and seven 'dry' schools, 1024 adolescent school children reported potentially building-related symptoms (BRS) in self-administrated questionnaires. From their classrooms dust samples were collected from floors, ventilation ducts, and air; settled dust w...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00356.x

    authors: Meyer HW,Würtz H,Suadicani P,Valbjørn O,Sigsgaard T,Gyntelberg F,Members of a Working Group under the Danish Mold in Buildings program (DAMIB).

    更新日期:2005-01-01 00:00:00

  • Cooking fuel type, household ventilation, and the risk of acute lower respiratory illness in urban Bangladeshi children: a longitudinal study.

    abstract:UNLABELLED:Acute lower respiratory illnesses (ALRI) are the leading cause of death among children <5 years. Studies have found that biomass cooking fuels are an important risk factor for ALRI. However, few studies have evaluated the influence of natural household ventilation indicators on ALRI. The purpose of this stud...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00754.x

    authors: Murray EL,Brondi L,Kleinbaum D,McGowan JE,Van Mels C,Brooks WA,Goswami D,Ryan PB,Klein M,Bridges CB

    更新日期:2012-04-01 00:00:00

  • Human convection flow in spaces with and without ventilation: personal exposure to floor-released particles and cough-released droplets.

    abstract:UNLABELLED:The effects of the human convective boundary layer (CBL), room airflow patterns, and their velocities on personal exposure are examined. Two pollutants are studied which simulate particles released from the feet and generated at distances of 2 and 3 m by a human cough. A thermal manikin whose body shape, siz...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12177

    authors: Licina D,Melikov A,Pantelic J,Sekhar C,Tham KW

    更新日期:2015-12-01 00:00:00

  • Effectiveness of a portable air cleaner in removing aerosol particles in homes close to highways.

    abstract::Outdoor traffic-related airborne particles can infiltrate a building and adversely affect the indoor air quality. Limited information is available on the effectiveness of high efficiency particulate air (HEPA) filtration of traffic-related particles. Here, we investigated the effectiveness of portable HEPA air cleaner...

    journal_title:Indoor air

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/ina.12502

    authors: Cox J,Isiugo K,Ryan P,Grinshpun SA,Yermakov M,Desmond C,Jandarov R,Vesper S,Ross J,Chillrud S,Dannemiller K,Reponen T

    更新日期:2018-11-01 00:00:00

  • Assessment of human exposure to indoor organic contaminants via dust ingestion in Pakistan.

    abstract:UNLABELLED:  Ingestion of indoor dust has been acknowledged as an important route of exposure to organic contaminants (OCs). We investigated the presence of polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), organophosphate flame retardants (OPFRs), polychlorinated biphenyls (PCBs), and ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00757.x

    authors: Ali N,Van den Eede N,Dirtu AC,Neels H,Covaci A

    更新日期:2012-06-01 00:00:00

  • Performance evaluation of a novel personalized ventilation-personalized exhaust system for airborne infection control.

    abstract::In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)-personalized exhaust (PE) system...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12127

    authors: Yang J,Sekhar SC,Cheong KW,Raphael B

    更新日期:2015-04-01 00:00:00

  • Machine learning and statistical models for predicting indoor air quality.

    abstract::Indoor air quality (IAQ), as determined by the concentrations of indoor air pollutants, can be predicted using either physically based mechanistic models or statistical models that are driven by measured data. In comparison with mechanistic models mostly used in unoccupied or scenario-based environments, statistical m...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/ina.12580

    authors: Wei W,Ramalho O,Malingre L,Sivanantham S,Little JC,Mandin C

    更新日期:2019-09-01 00:00:00

  • Classrooms' indoor environmental conditions affecting the academic achievement of students and teachers in higher education: A systematic literature review.

    abstract::This study reports the outcomes of a systematic literature review, which aims to determine the influence of four indoor environmental parameters - indoor air, thermal, acoustic, and lighting conditions -on the quality of teaching and learning and on students' academic achievement in schools for higher education, defin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12745

    authors: Brink HW,Loomans MGLC,Mobach MP,Kort HSM

    更新日期:2020-09-24 00:00:00

  • Characterization of endotoxin and 3-hydroxy fatty acid levels in air and settled dust from commercial aircraft cabins.

    abstract::Endotoxin was measured in air and dust samples collected during four commercial aircraft flights. Samples were analyzed for endotoxin biological activity using the Limulus assay. 3-hydroxy fatty acids (3-OH FA) of carbon chain lengths C10:0-C18:0 were determined in dust by gas chromatography-ion trap tandem mass spect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00175.x

    authors: Hines CJ,Waters MA,Larsson L,Petersen MR,Saraf A,Milton DK

    更新日期:2003-06-01 00:00:00

  • Modeling the internal dynamics of energy and mass transfer in an imperfectly mixed ventilated airspace.

    abstract:UNLABELLED:The present paper outlines a modeling approach, which has been developed to model the internal dynamics of heat and moisture transfer in an imperfectly mixed ventilated airspace. The modeling approach, which combines the classical heat and moisture balance differential equations with the use of experimental ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00168.x

    authors: Janssens K,Van Brecht A,Zerihun Desta T,Boonen C,Berckmans D

    更新日期:2004-06-01 00:00:00

  • Relationships between estimated flame retardant emissions and levels in indoor air and house dust.

    abstract::A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12332

    authors: Liagkouridis I,Cequier E,Lazarov B,Palm Cousins A,Thomsen C,Stranger M,Cousins IT

    更新日期:2017-05-01 00:00:00

  • Cross-city comparison of indoor air temperatures in air-conditioned spaces.

    abstract::Field measurements were collected through physical measurements and observations in the cities of Seoul, Korea; Eugene and Portland, Oregon; and Yokohama, Japan, during the fall, winter, and summer seasons from 2005 to 2006. A total of 1733 data sets were collected (Seoul - 713; Oregon - 807; Yokohama - 213) in variet...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00705.x

    authors: Kim H,Chun C,Kwok A,Ota A,Tamura A

    更新日期:2011-08-01 00:00:00

  • Exposure to organophosphate and polybrominated diphenyl ether flame retardants via indoor dust and childhood asthma.

    abstract::Although the ubiquitous detection of polybrominated diphenyl ether (PBDE) and organophosphate flame retardants (PFRs) in indoor dust has raised health concerns, only very few epidemiological studies have assessed their impact on human health. Inhalation of dust is one of the exposure routes of FRs, especially in child...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12221

    authors: Canbaz D,van Velzen MJ,Hallner E,Zwinderman AH,Wickman M,Leonards PE,van Ree R,van Rijt LS

    更新日期:2016-06-01 00:00:00

  • Comparison of disinfection performance of UVC-LED and conventional upper-room UVGI systems.

    abstract::We developed a novel, compact upper-room ultraviolet germicidal irradiation system with light-emitting diode sources (UR-UVGI-LED) to enhance the disinfection of bioaerosols in an enclosed room space. Its effectiveness was evaluated and compared with the conventional upper-room ultraviolet germicidal irradiation syste...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12619

    authors: Nunayon SS,Zhang H,Lai ACK

    更新日期:2020-01-01 00:00:00

  • Association of size-fractionated indoor particulate matter and black carbon with heart rate variability in healthy elderly women in Beijing.

    abstract::Associations between size-fractionated indoor particulate matter (PM) and black carbon (BC) and heart rate variability (HRV) and heart rate (HR) in elderly women remain unclear. Twenty-nine healthy elderly women were measured for 24-hour HRV/HR indices. Real-time size-fractionated indoor PM and BC were monitored on th...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12449

    authors: Dong W,Pan L,Li H,Miller MR,Loh M,Wu S,Xu J,Yang X,Shan J,Chen Y,Deng F,Guo X

    更新日期:2018-05-01 00:00:00

  • Removal of contaminants released from room surfaces by displacement and mixing ventilation: modeling and validation.

    abstract:UNLABELLED:This paper presents the experimental and numerical modeling of contaminant dispersion in a full-scale environmental chamber with different room air distribution systems. For the experimental modeling, an area source with uniform emissions of a hypothetical contaminant (SF6) from the entire floor surface is d...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00383.x

    authors: He G,Yang X,Srebric J

    更新日期:2005-10-01 00:00:00

  • Risk factors in heating, ventilating, and air-conditioning systems for occupant symptoms in US office buildings: the US EPA BASE study.

    abstract:UNLABELLED:Building-related symptoms in office workers worldwide are common, but of uncertain etiology. One cause may be contaminants related to characteristics of heating, ventilating, and air-conditioning (HVAC) systems. We analyzed data from 97 representative air-conditioned US office buildings in the Building Asses...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00531.x

    authors: Mendell MJ,Lei-Gomez Q,Mirer AG,Seppänen O,Brunner G

    更新日期:2008-08-01 00:00:00

  • Sorptive interactions between VOCs and indoor materials.

    abstract::This study was carried out using various materials (carpet, gypsum board, upholstery, vinyl and wood flooring, acoustic tiles, and fruit) that were exposed to eight gaseous volatile organic compounds (VOCs) (isopropanol, MTBE, cyclohexane, toluene, ethylbenzene, tetrachloroethene, 1,2-dichlorobenzene, and 1,2,4-trichl...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.110406.x

    authors: Won D,Corsi RL,Rynes M

    更新日期:2001-12-01 00:00:00

  • Respiratory effects of experimental exposure to office dust.

    abstract:UNLABELLED:The aim of this experiment was to test if healthy persons respond to exposures to normal office dust with objective or subjective effects in a dose-related way. If they did, the importance of their personal characteristics should be investigated. This paper presents the results related to respiratory effects...

    journal_title:Indoor air

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1600-0668.2004.00252.x

    authors: Mølhave L,Kjaergaard SK,Attermann J

    更新日期:2004-12-01 00:00:00