Association of size-fractionated indoor particulate matter and black carbon with heart rate variability in healthy elderly women in Beijing.

Abstract:

:Associations between size-fractionated indoor particulate matter (PM) and black carbon (BC) and heart rate variability (HRV) and heart rate (HR) in elderly women remain unclear. Twenty-nine healthy elderly women were measured for 24-hour HRV/HR indices. Real-time size-fractionated indoor PM and BC were monitored on the same day and on the preceding day. Mixed-effects models were applied to investigate the associations between pollutants and HRV/HR indices. Increases in size-fractionated indoor PM were significantly associated with declines in power in the high-frequency band (HF), power in the low-frequency band (LF), and standard deviation of all NN intervals (SDNN). The largest decline in HF was 19% at 5-minute moving average for an interquartile range (IQR) increase (24 μg/m3 ) in PM0.5 . The results showed that smaller particles could lead to greater reductions in HRV indices. The reported associations were modified by body mass index (BMI): Declines in HF at 5-minute average for an IQR increase in PM0.5 were 34.5% and 1.0% for overweight (BMI ≥25 kg/m2 ) and normal-weight (BMI <25 kg/m2 ) participants, respectively. Moreover, negative associations between BC and HRV indices were found to be significant in overweight participants. Increases in size-fractionated indoor PM and BC were associated with compromised cardiac autonomic function in healthy elderly women, especially overweight ones.

journal_name

Indoor Air

journal_title

Indoor air

authors

Dong W,Pan L,Li H,Miller MR,Loh M,Wu S,Xu J,Yang X,Shan J,Chen Y,Deng F,Guo X

doi

10.1111/ina.12449

subject

Has Abstract

pub_date

2018-05-01 00:00:00

pages

373-382

issue

3

eissn

0905-6947

issn

1600-0668

journal_volume

28

pub_type

杂志文章
  • Characterization of particulate emissions from occupant activities in offices.

    abstract::This paper characterizes the relationship between occupant activities and indoor air particulate levels in a non-smoking office building. Occupant activities were recorded on video. Particulate concentrations were monitored by three optical particle counters (OPCs) in five size ranges at three heights. Particulate mas...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.011001035.x

    authors: Luoma M,Batterman SA

    更新日期:2001-03-01 00:00:00

  • Organic compounds as indicators of air pollution.

    abstract::The most important indoor air pollutants have already been addressed with individual national guidelines or recommendations. However, an international set of guidelines or recommendations for indoor air quality (IAQ) is needed for these pollutants based on general and uniform rules for setting such standards. A major ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.13.s.6.2.x

    authors: Mølhave L

    更新日期:2003-01-01 00:00:00

  • Airborne particle emission of a commercial 3D printer: the effect of filament material and printing temperature.

    abstract::The knowledge of exposure to the airborne particle emitted from three-dimensional (3D) printing activities is becoming a crucial issue due to the relevant spreading of such devices in recent years. To this end, a low-cost desktop 3D printer based on fused deposition modeling (FDM) principle was used. Particle number, ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12310

    authors: Stabile L,Scungio M,Buonanno G,Arpino F,Ficco G

    更新日期:2017-03-01 00:00:00

  • Productivity and fatigue.

    abstract:UNLABELLED:In studying productivity, effects of environmental factors have focused only on performance. However, previous studies of the impact of the environment upon performance of mental tasks generally conclude that productivity research is somewhat confusing because the results are sometimes conflicting. In experi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00281.x

    authors: Tanabe S,Nishihara N

    更新日期:2004-01-01 00:00:00

  • Responding to sudden pollutant releases in office buildings: 1. Framework and analysis tools.

    abstract::We describe a framework for developing response recommendations to unexpected toxic pollutant releases in commercial buildings. It may be applied in conditions where limited building- and event-specific information is available. The framework is based on a screening-level methodology to develop insights, or rules-of-t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00183.x

    authors: Sohn MD,Sextro RG,Gadgil AJ,Daisey JM

    更新日期:2003-09-01 00:00:00

  • The field comparison of three measuring techniques for evaluation of the surface dust level in ventilation ducts.

    abstract::This paper reports the comparison of three measuring methods for quantifying the amount of dust on the inner surface of ventilation ducts: 1) a vacuum test method; 2) a gravimetric tape method; and 3) an optical method. Thirteen recently constructed buildings were selected for the field test in the Helsinki metropolit...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.120106.x

    authors: Holopainen R,Asikainen V,Pasanen P,Seppänen O

    更新日期:2002-03-01 00:00:00

  • Association of gas cooking with children's respiratory health: results from GINIplus and LISAplus birth cohort studies.

    abstract:UNLABELLED:Previous studies have found inconsistent results on the association between asthma in children and gas cooking emissions. We aimed to assess the effects of the long-term exposure to gas cooking on the onset of asthma and respiratory symptoms, focusing on wheezing, in children from two German birth cohorts: L...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2012.00784.x

    authors: Casas L,Tischer C,Tiesler C,Brüske I,Koletzko S,Bauer CP,Wichmann HE,von Berg A,Berdel D,Krämer U,Schaaf B,Lehmann I,Herbarth O,Heinrich J,GINIplus and LISAplus Study Group.

    更新日期:2012-12-01 00:00:00

  • Real-time measurements of PM2.5 and ozone to assess the effectiveness of residential indoor air filtration in Shanghai homes.

    abstract::Portable air cleaners are increasingly used in polluted areas in an attempt to reduce human exposure; however, there has been limited work characterizing their effectiveness at reducing exposure. With this in mind, we recruited forty-three children with asthma from suburban Shanghai and deployed air cleaners (with HEP...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12716

    authors: Barkjohn KK,Norris C,Cui X,Fang L,Zheng T,Schauer JJ,Li Z,Zhang Y,Black M,Zhang JJ,Bergin MH

    更新日期:2021-01-01 00:00:00

  • Experimental validation of a computational fluid dynamics model for IAQ applications in ice rink arenas.

    abstract::Many ice rink arenas have ice resurfacing equipment that uses fossil fuel as power. The combustion byproducts are a major source of contamination. Ventilation along with other pollution source control measures is the most widely applied strategy to lower the contaminant level below the threshold limit and maintain acc...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.110206.x

    authors: Yang C,Demokritou P,Chen Q,Spengler J

    更新日期:2001-06-01 00:00:00

  • Droplet fate in indoor environments, or can we prevent the spread of infection?

    abstract:UNLABELLED:When considering how people are infected and what can be done to prevent the infections, answers from many disciplines are sought: microbiology, epidemiology, medicine, engineering, and physics. There are many pathways to infection spread, and among the most significant from the epidemiological point of view...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2006.00432.x

    authors: Morawska L

    更新日期:2006-10-01 00:00:00

  • Respiratory effects of experimental exposure to office dust.

    abstract:UNLABELLED:The aim of this experiment was to test if healthy persons respond to exposures to normal office dust with objective or subjective effects in a dose-related way. If they did, the importance of their personal characteristics should be investigated. This paper presents the results related to respiratory effects...

    journal_title:Indoor air

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1600-0668.2004.00252.x

    authors: Mølhave L,Kjaergaard SK,Attermann J

    更新日期:2004-12-01 00:00:00

  • Ultrafine particles from electric appliances and cooking pans: experiments suggesting desorption/nucleation of sorbed organics as the primary source.

    abstract::Ultrafine particles are observed when metal surfaces, such as heating elements in electric appliances, or even empty cooking pans, are heated. The source of the particles has not been identified. We present evidence that particles >10 nm are not emitted directly from the heating elements or the metal surfaces. Using r...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12163

    authors: Wallace LA,Ott WR,Weschler CJ

    更新日期:2015-10-01 00:00:00

  • Effects of cigarette smoking and biomass fuel on lung function and respiratory symptoms in middle-aged adults and the elderly in Guangdong province, China: A cross-sectional study.

    abstract::We sought to investigate the association between active cigarette smoking (ex- and current smokers) with or without exposure to biomass fuels and respiratory symptoms/lung function in middle-aged adults and the elderly. In the chronic obstructive pulmonary disease surveillance conducted in six cities of Guangdong prov...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12671

    authors: Zheng XY,Li ZL,Li C,Guan WJ,Li LX,Xu YJ

    更新日期:2020-09-01 00:00:00

  • Presence and variability of culturable bioaerosols in three multi-family apartment buildings with different ventilation systems in the Northeastern US.

    abstract::Bioaerosol concentrations in residential buildings located in the Northeastern US have not been widely studied. Here, in 2011-2015, we studied the presence and seasonal variability of culturable fungi and bacteria in three multi-family apartment buildings and correlated the bioaerosol concentrations with building vent...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12743

    authors: Myers NT,Calderón L,Pavilonis B,Wang Z,Xiong Y,Sorensen-Allacci M,Plotnik D,Senick J,Gong J,Krogmann U,Andrews CJ,Mainelis G

    更新日期:2020-09-15 00:00:00

  • Evaluation of ionic air purifiers for reducing aerosol exposure in confined indoor spaces.

    abstract:UNLABELLED:Numerous techniques have been developed over the years for reducing aerosol exposure in indoor air environments. Among indoor air purifiers of different types, ionic emitters have gained increasing attention and are presently used for removing dust particles, aeroallergens and airborne microorganisms from in...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00364.x

    authors: Grinshpun SA,Mainelis G,Trunov M,Adhikari A,Reponen T,Willeke K

    更新日期:2005-08-01 00:00:00

  • Investigating measurements of fine particle (PM2.5 ) emissions from the cooking of meals and mitigating exposure using a cooker hood.

    abstract::There is growing awareness that indoor exposure to particulate matter with diameter ≤ 2.5 μm (PM2.5 ) is associated with an increased risk of adverse health effects. Cooking is a key indoor source of PM2.5 and an activity conducted daily in most homes. Population scale models can predict occupant exposures to PM2.5 , ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12542

    authors: O'Leary C,de Kluizenaar Y,Jacobs P,Borsboom W,Hall I,Jones B

    更新日期:2019-05-01 00:00:00

  • Indoor gaseous air pollutants determinants in office buildings-The OFFICAIR project.

    abstract::The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12609

    authors: Spinazzè A,Campagnolo D,Cattaneo A,Urso P,Sakellaris IA,Saraga DE,Mandin C,Canha N,Mabilia R,Perreca E,Mihucz VG,Szigeti T,Ventura G,de Oliveira Fernandes E,de Kluizenaar Y,Cornelissen E,Hänninen O,Carrer P,Wolkoff P

    更新日期:2020-01-01 00:00:00

  • Variations of formaldehyde and VOC levels during 3 years in new and older homes.

    abstract:UNLABELLED:Indoor air organic compounds were continuously monitored during 3 years in new and older homes which were voluntarily selected throughout countries. The levels of volatile organic compounds (VOCs) in the new homes decreased markedly after 1 year, and steady emissions of VOCs were obtained in the initial mont...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00408.x

    authors: Park JS,Ikeda K

    更新日期:2006-04-01 00:00:00

  • Chamber testing of adsorption of volatile organic compounds (VOCs) on material surfaces.

    abstract::A simple test chamber method to quantify adsorption and desorption of organic compounds on material surfaces is described. Important environmental parameters such as temperature, relative humidity and air velocity were varied and controlled independently around typical indoor values. Experiments were performed with al...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.1999.t01-3-00002.x

    authors: Jørgensen RB,Bjørseth O,Malvik B

    更新日期:1999-03-01 00:00:00

  • Semivolatile organic compounds in French schools: Partitioning between the gas phase, airborne particles and settled dust.

    abstract::The indoor environmental quality in classrooms can largely affect children's daily exposure to indoor chemicals in schools. To date, there has not been a comprehensive study of the concentrations of semivolatile organic compounds (SVOCs) in French schools. Therefore, the French Observatory for Indoor Air Quality (OQAI...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12724

    authors: Wei W,Dassonville C,Sivanantham S,Gregoire A,Mercier F,Le Bot B,Malingre L,Ramalho O,Derbez M,Mandin C

    更新日期:2021-01-01 00:00:00

  • Assessment of indoor HONO formation mechanisms based on in situ measurements and modeling.

    abstract::The photolysis of HONO has been found to be the oxidation driver through OH formation in the indoor air measurement campaign SURFin, an extensive campaign carried out in July 2012 in a classroom in Marseille. In this study, the INCA-Indoor model is used to evaluate different HONO formation mechanisms that have been us...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12320

    authors: Mendez M,Blond N,Amedro D,Hauglustaine DA,Blondeau P,Afif C,Fittschen C,Schoemaecker C

    更新日期:2017-03-01 00:00:00

  • Does e-cigarette consumption cause passive vaping?

    abstract:UNLABELLED:Electronic cigarette consumption ('vaping') is marketed as an alternative to conventional tobacco smoking. Technically, a mixture of chemicals containing carrier liquids, flavors, and optionally nicotine is vaporized and inhaled. The present study aims at the determination of the release of volatile organic ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2012.00792.x

    authors: Schripp T,Markewitz D,Uhde E,Salthammer T

    更新日期:2013-02-01 00:00:00

  • Early age exposure to moisture damage and systemic inflammation at the age of 6 years.

    abstract::Cross-sectional studies have shown that exposure to indoor moisture damage and mold may be associated with subclinical inflammation. Our aim was to determine whether early age exposure to moisture damage or mold is prospectively associated with subclinical systemic inflammation or with immune responsiveness in later c...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12454

    authors: Karvonen AM,Tischer C,Kirjavainen PV,Roponen M,Hyvärinen A,Illi S,Mustonen K,Pfefferle PI,Renz H,Remes S,Schaub B,von Mutius E,Pekkanen J

    更新日期:2018-05-01 00:00:00

  • Personal measurement of exposure to black carbon and ultrafine particles in schoolchildren from PARIS cohort (Paris, France).

    abstract::This study aimed to measure in French children personal exposure concentrations of black carbon (BC) and ultrafine particles (UFP) and to quantify the contribution of different microenvironments (home, school, places of extracurricular activities, transport) to their total exposure. It was conducted on 96 9-year-old c...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12358

    authors: Paunescu AC,Attoui M,Bouallala S,Sunyer J,Momas I

    更新日期:2017-07-01 00:00:00

  • Comparing zonal and CFD model predictions of isothermal indoor airflows to experimental data.

    abstract::It is inappropriate to use the assumption of instantaneously well-mixed zones to model airflows and pollutant transport in large indoor spaces. We investigate two approaches for describing the details of airflows in large indoor spaces, for accuracy and suitability for integration with multi-zone infiltration models. ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00160.x

    authors: Mora L,Gadgil AJ,Wurtz E

    更新日期:2003-06-01 00:00:00

  • Polybrominated diphenyl ether (PBDE) concentrations and resulting exposure in homes in California: relationships among passive air, surface wipe and dust concentrations, and temporal variability.

    abstract::Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12130

    authors: Bennett DH,Moran RE,Wu XM,Tulve NS,Clifton MS,Colón M,Weathers W,Sjödin A,Jones R,Hertz-Picciotto I

    更新日期:2015-04-01 00:00:00

  • Indoor ozone/human chemistry and ventilation strategies.

    abstract::This study aimed to better understand and quantify the influence of ventilation strategies on occupant-related indoor air chemistry. The oxidation of human skin oil constituents was studied in a continuously ventilated climate chamber at two air exchange rates (1 h-1 and 3 h-1 ) and two initial ozone mixing ratios (30...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12594

    authors: Salvador CM,Bekö G,Weschler CJ,Morrison G,Le Breton M,Hallquist M,Ekberg L,Langer S

    更新日期:2019-11-01 00:00:00

  • Quantitative measurement of airborne cockroach allergen in New York City apartments.

    abstract:UNLABELLED:We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10-15 LPM in 19 New York City apartments in which an asthmatic child...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00728.x

    authors: Esposito WA,Chew GL,Correa JC,Chillrud SN,Miller RL,Kinney PL

    更新日期:2011-12-01 00:00:00

  • Effects of energy retrofits on Indoor Air Quality in multifamily buildings.

    abstract::We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12555

    authors: Du L,Leivo V,Prasauskas T,Täubel M,Martuzevicius D,Haverinen-Shaughnessy U

    更新日期:2019-07-01 00:00:00

  • Exposure to ultrafine particles in children until 18 years of age: A systematic review.

    abstract::Airborne ultrafine particles (UFP) have been related to adverse health effects, but exposure in vulnerable population groups such as children is still not well understood. We aim to review the scientific literature regarding personal exposure to UFP in different microenvironments in populations until 18 years of age. ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12620

    authors: García-Hernández C,Ferrero A,Estarlich M,Ballester F

    更新日期:2020-01-01 00:00:00