Abstract:
:This study aimed to better understand and quantify the influence of ventilation strategies on occupant-related indoor air chemistry. The oxidation of human skin oil constituents was studied in a continuously ventilated climate chamber at two air exchange rates (1 h-1 and 3 h-1 ) and two initial ozone mixing ratios (30 and 60 ppb). Additional measurements were performed to investigate the effect of intermittent ventilation ("off" followed by "on"). Soiled t-shirts were used to simulate the presence of occupants. A time-of-flight-chemical ionization mass spectrometer (ToF-CIMS) in positive mode using protonated water clusters was used to measure the oxygenated reaction products geranyl acetone, 6-methyl-5-hepten-2-one (6-MHO) and 4-oxopentanal (4-OPA). The measurement data were used in a series of mass balance models accounting for formation and removal processes. Reactions of ozone with squalene occurring on the surface of the t-shirts are mass transport limited; ventilation rate has only a small effect on this surface chemistry. Ozone-squalene reactions on the t-shirts produced gas-phase geranyl acetone, which was subsequently removed almost equally by ventilation and further reaction with ozone. About 70% of gas-phase 6-MHO was produced in surface reactions on the t-shirts, the remainder in secondary gas-phase reactions of ozone with geranyl acetone. 6-MHO was primarily removed by ventilation, while further reaction with ozone was responsible for about a third of its removal. 4-OPA was formed primarily on the surfaces of the shirts (~60%); gas-phase reactions of ozone with geranyl acetone and 6-MHO accounted for ~30% and ~10%, respectively. 4-OPA was removed entirely by ventilation. The results from the intermittent ventilation scenarios showed delayed formation of the reaction products and lower product concentrations compared to continuous ventilation.
journal_name
Indoor Airjournal_title
Indoor airauthors
Salvador CM,Bekö G,Weschler CJ,Morrison G,Le Breton M,Hallquist M,Ekberg L,Langer Sdoi
10.1111/ina.12594subject
Has Abstractpub_date
2019-11-01 00:00:00pages
913-925issue
6eissn
0905-6947issn
1600-0668journal_volume
29pub_type
杂志文章相关文献
INDOOR AIR文献大全abstract::Analysis of the dust from heating, ventilation, and air conditioning (HVAC) filters is a promising long-term sampling method to characterize airborne particle-bound contaminants. This filter forensics (FF) approach provides valuable insights about differences between buildings, but does not allow for an estimation of ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12536
更新日期:2019-05-01 00:00:00
abstract::The present paper shows that introducing or removing the same pollution source in an office in two independent investigations, one in Denmark and one in Sweden, using similar experimental methodology, resulted in similar and repeatable effects on subjective assessments of perceived air quality, intensity of sick build...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2002.01101.x
更新日期:2002-06-01 00:00:00
abstract::This paper characterizes the relationship between occupant activities and indoor air particulate levels in a non-smoking office building. Occupant activities were recorded on video. Particulate concentrations were monitored by three optical particle counters (OPCs) in five size ranges at three heights. Particulate mas...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2001.011001035.x
更新日期:2001-03-01 00:00:00
abstract::Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12130
更新日期:2015-04-01 00:00:00
abstract::Concentrations and emission rates of sixteen trace elements in emitted PM during heating soybean oil using three types of pans, including Teflon, granitium, and cast-iron, were investigated. Statistically significant decreases in Mn and Co emission rates were observed when the oil was heated in the cast-iron pan compa...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12641
更新日期:2020-05-01 00:00:00
abstract::A portion of electronic equipment failures is a consequence of particle deposition on electronic circuits in normal indoor environments. Deposited hygroscopic particles reduce the electrical isolation (EI) between conductors. In laboratory experiments, we investigated the mechanisms, locations, and effects of particle...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2000.010001047.x
更新日期:2000-03-01 00:00:00
abstract:UNLABELLED:Moisture accumulation in building structures, the microbial ecology of water-damaged sites and human exposure to biological contaminants are complex phenomena and may result in various types of indoor air pollution and adverse health outcomes. Commonly reported are building-related irritation symptoms, respi...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00344.x
更新日期:2005-01-01 00:00:00
abstract:UNLABELLED:We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10-15 LPM in 19 New York City apartments in which an asthmatic child...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00728.x
更新日期:2011-12-01 00:00:00
abstract::A nationwide cross-sectional study of 3335 employees was conducted in 320 offices in Japan to estimate the prevalence of building-related symptoms (BRSs) and determine the risk factors related to work environment, Indoor Air Quality, and occupational stress. Data were collected through self-administered questionnaires...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12158
更新日期:2015-10-01 00:00:00
abstract::This study aimed to measure in French children personal exposure concentrations of black carbon (BC) and ultrafine particles (UFP) and to quantify the contribution of different microenvironments (home, school, places of extracurricular activities, transport) to their total exposure. It was conducted on 96 9-year-old c...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12358
更新日期:2017-07-01 00:00:00
abstract:UNLABELLED:In case contaminants are found in enclosed environments such as aircraft cabins or buildings, it is useful to find the contaminant sources. One method to locate contaminant sources is by inverse computational fluid dynamics (CFD) modeling. As the inverse CFD modeling is ill posed, this paper has proposed to ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2006.00452.x
更新日期:2007-06-01 00:00:00
abstract::High-efficiency particulate air (HEPA) filtration in combination with an electrostatic precipitator (ESP) can be a cost-effective approach to reducing indoor particulate exposure, but ESPs produce ozone. The health effect of combined ESP-HEPA filtration has not been examined. We conducted an intervention study in 89 v...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12447
更新日期:2018-05-01 00:00:00
abstract::Airtight construction and high-performance thermal insulation materials are commonly considered important building features to enhance indoor thermal comfort while reducing thermal load. However, when water vapor is generated in such airtight indoor spaces, it cannot be discharged to the outside, causing interstitial ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12622
更新日期:2020-03-01 00:00:00
abstract::The formaldehyde emission from wood-based building materials is usually determined in large chambers at a defined temperature, humidity and ventilation rate. In this article, a simpler method, the Field and Laboratory Emission Cell (FLEC), is described for determination of the formaldehyde emission and it is compared ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.1999.00006.x
更新日期:1999-12-01 00:00:00
abstract:UNLABELLED:Electronic cigarette consumption ('vaping') is marketed as an alternative to conventional tobacco smoking. Technically, a mixture of chemicals containing carrier liquids, flavors, and optionally nicotine is vaporized and inhaled. The present study aims at the determination of the release of volatile organic ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2012.00792.x
更新日期:2013-02-01 00:00:00
abstract:UNLABELLED:The aim of this experiment was to test if healthy persons respond to exposures to normal office dust with objective or subjective effects in a dose-related way. If they did, the importance of their personal characteristics should be investigated. This paper presents the results related to respiratory effects...
journal_title:Indoor air
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1600-0668.2004.00252.x
更新日期:2004-12-01 00:00:00
abstract:UNLABELLED:Indoor exposures to allergens, mold spores, and endotoxin have been suggested as etiological agents of asthma; therefore, accurate determination of those exposures, especially in young children (6-36 months), is important for understanding the development of asthma. Because use of personal sampling equipment...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00749.x
更新日期:2012-04-01 00:00:00
abstract:UNLABELLED:When considering how people are infected and what can be done to prevent the infections, answers from many disciplines are sought: microbiology, epidemiology, medicine, engineering, and physics. There are many pathways to infection spread, and among the most significant from the epidemiological point of view...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0668.2006.00432.x
更新日期:2006-10-01 00:00:00
abstract::This paper reports the comparison of three measuring methods for quantifying the amount of dust on the inner surface of ventilation ducts: 1) a vacuum test method; 2) a gravimetric tape method; and 3) an optical method. Thirteen recently constructed buildings were selected for the field test in the Helsinki metropolit...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2002.120106.x
更新日期:2002-03-01 00:00:00
abstract::Endotoxin was measured in air and dust samples collected during four commercial aircraft flights. Samples were analyzed for endotoxin biological activity using the Limulus assay. 3-hydroxy fatty acids (3-OH FA) of carbon chain lengths C10:0-C18:0 were determined in dust by gas chromatography-ion trap tandem mass spect...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2003.00175.x
更新日期:2003-06-01 00:00:00
abstract::This study aims to develop an approach to couple a computational fluid dynamics (CFD) solver to the University of California, Berkeley (UCB) thermal comfort model to accurately evaluate thermal comfort. The coupling was made using an iterative JavaScript to automatically transfer data for each individual segment of th...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12451
更新日期:2018-05-01 00:00:00
abstract::Carbon monoxide (CO) alarms are extensively used in domestic premises in the UK to help protect against CO poisoning. Their expected lifetime has been increasing, and some current models now have a replacement period of more than 6 years under normal operation. However, concerns have been expressed as to the reliabili...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12022
更新日期:2013-08-01 00:00:00
abstract:UNLABELLED:Building-related symptoms in office workers worldwide are common, but of uncertain etiology. One cause may be contaminants related to characteristics of heating, ventilating, and air-conditioning (HVAC) systems. We analyzed data from 97 representative air-conditioned US office buildings in the Building Asses...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2008.00531.x
更新日期:2008-08-01 00:00:00
abstract::We investigated the physicochemical properties (size, shape, elemental composition, and endotoxin) of size resolved particulate matter (PM) collected from the indoor and corridor environments of classrooms. A comparative hazard profiling of these PM was conducted using human microvascular endothelial cells (HMVEC). Ox...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12341
更新日期:2017-05-01 00:00:00
abstract::It has not yet been possible to quantify dose-related health risks attributable to indoor dampness or mold (D/M), to support setting specific health-related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of q...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/ina.12464
更新日期:2018-07-01 00:00:00
abstract:UNLABELLED:Continuous emission of unipolar ions has been shown to improve the performance of respirators and stationary filters challenged with non-biological particles. In this study, we investigated the ion-induced enhancement effect while challenging a low-efficiency heating, ventilation and air-conditioning (HVAC) ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2007.00512.x
更新日期:2008-04-01 00:00:00
abstract::This article reports the results of an investigation, based on fundamental fluid dynamics and mass transfer theory, carried out to obtain a general understanding of the mechanisms involved in the emissions from building materials in ventilated rooms. In addition, a generally applicable method for the prediction of sur...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2001.011003162.x
更新日期:2001-09-01 00:00:00
abstract::Ultrafine particles are observed when metal surfaces, such as heating elements in electric appliances, or even empty cooking pans, are heated. The source of the particles has not been identified. We present evidence that particles >10 nm are not emitted directly from the heating elements or the metal surfaces. Using r...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12163
更新日期:2015-10-01 00:00:00
abstract:UNLABELLED:In this paper, a method is developed to assess the performance of adsorptive building materials that are used for reducing indoor pollutant concentrations. Mass transfer has a great influence on the materials' performance. To control the mass transfer rate precisely in the performance test, the authors have ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00316.x
更新日期:2004-01-01 00:00:00
abstract:UNLABELLED:Many volatile organic compounds (VOCs) are classified as known or possible carcinogens, irritants, and toxicants, and VOC exposure has been associated with the onset and exacerbation of asthma. This study characterizes VOC levels in 126 homes of children with asthma in Detroit, Michigan, USA. The total targe...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12086
更新日期:2014-08-01 00:00:00