Abstract:
:This paper characterizes the relationship between occupant activities and indoor air particulate levels in a non-smoking office building. Occupant activities were recorded on video. Particulate concentrations were monitored by three optical particle counters (OPCs) in five size ranges at three heights. Particulate mass concentrations were measured gravimetrically and bioaerosol concentrations were determined by impaction methods. Occupant activities and number concentrations were determined with 1-min resolution over a 1-week period. Occupant activities such as walking past or visiting the monitoring site explained 24-55% of the variation of 1- to 25-micron diameter particle number concentrations. Statistical models associating particulate concentrations with occupant activities depended on the size fraction and included an autocorrelative term. Occupant activities are estimated to contribute up to 10 micrograms m-3 in particulate concentrations per person. Number concentrations of particles smaller than 1 micron had little correlation with indoor activities other than cigarette smoking and were highly correlated with outdoor levels. The method can be used to characterize emissions from activities if rapid measurements can be made and if activities can be coded from the video record.
journal_name
Indoor Airjournal_title
Indoor airauthors
Luoma M,Batterman SAdoi
10.1034/j.1600-0668.2001.011001035.xsubject
Has Abstractpub_date
2001-03-01 00:00:00pages
35-48issue
1eissn
0905-6947issn
1600-0668journal_volume
11pub_type
杂志文章相关文献
INDOOR AIR文献大全abstract::A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12332
更新日期:2017-05-01 00:00:00
abstract::Airtight construction and high-performance thermal insulation materials are commonly considered important building features to enhance indoor thermal comfort while reducing thermal load. However, when water vapor is generated in such airtight indoor spaces, it cannot be discharged to the outside, causing interstitial ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12622
更新日期:2020-03-01 00:00:00
abstract::Bioaerosol concentrations in residential buildings located in the Northeastern US have not been widely studied. Here, in 2011-2015, we studied the presence and seasonal variability of culturable fungi and bacteria in three multi-family apartment buildings and correlated the bioaerosol concentrations with building vent...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12743
更新日期:2020-09-15 00:00:00
abstract:UNLABELLED:A cross-sectional study was carried out at Tianjin University campus, China, from February 21 to June10, 2006, to survey the association between dampness in dorms and allergy and airways infection among college students. The health and dampness condition were self-reported by 3436 students living in 1511 dor...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2008.00577.x
更新日期:2009-04-01 00:00:00
abstract::Variable methods of dust collection may lead to uncertainty in the measurement of biomarkers. The purpose of this study was to examine the effect of two different dust collection devices on dust weight, Der p 1, Fel d 1, and endotoxin levels. We compared: (1) a nylon mesh sock inserted between the furniture attachment...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00253.x
更新日期:2004-06-01 00:00:00
abstract::We determined the moisture levels, relative humidity (RH) or moisture content (MC) of materials, and concentrations of culturable fungi, actinomycetes and total spores as well as a composition of fungal flora in 122 building material samples collected from 18 moisture problem buildings. The purpose of this work was to...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2000.010002111.x
更新日期:2000-06-01 00:00:00
abstract:UNLABELLED:Meteorological factors such as relative humidity directly correlate with airborne fungal levels outdoors and indoors. While dehumidification alone is effective at reducing moisture necessary for mold growth, it is inadequate as a single intervention as it does not remove viable and non-viable fungal spores t...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00379.x
更新日期:2005-12-01 00:00:00
abstract::There is growing awareness that indoor exposure to particulate matter with diameter ≤ 2.5 μm (PM2.5 ) is associated with an increased risk of adverse health effects. Cooking is a key indoor source of PM2.5 and an activity conducted daily in most homes. Population scale models can predict occupant exposures to PM2.5 , ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12542
更新日期:2019-05-01 00:00:00
abstract::We investigated the physicochemical properties (size, shape, elemental composition, and endotoxin) of size resolved particulate matter (PM) collected from the indoor and corridor environments of classrooms. A comparative hazard profiling of these PM was conducted using human microvascular endothelial cells (HMVEC). Ox...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12341
更新日期:2017-05-01 00:00:00
abstract::The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12609
更新日期:2020-01-01 00:00:00
abstract::In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)-personalized exhaust (PE) system...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12127
更新日期:2015-04-01 00:00:00
abstract::Outdoor traffic-related airborne particles can infiltrate a building and adversely affect the indoor air quality. Limited information is available on the effectiveness of high efficiency particulate air (HEPA) filtration of traffic-related particles. Here, we investigated the effectiveness of portable HEPA air cleaner...
journal_title:Indoor air
pub_type: 杂志文章,随机对照试验
doi:10.1111/ina.12502
更新日期:2018-11-01 00:00:00
abstract:UNLABELLED:Electronic cigarette consumption ('vaping') is marketed as an alternative to conventional tobacco smoking. Technically, a mixture of chemicals containing carrier liquids, flavors, and optionally nicotine is vaporized and inhaled. The present study aims at the determination of the release of volatile organic ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2012.00792.x
更新日期:2013-02-01 00:00:00
abstract::We developed a novel, compact upper-room ultraviolet germicidal irradiation system with light-emitting diode sources (UR-UVGI-LED) to enhance the disinfection of bioaerosols in an enclosed room space. Its effectiveness was evaluated and compared with the conventional upper-room ultraviolet germicidal irradiation syste...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12619
更新日期:2020-01-01 00:00:00
abstract::This paper reports the comparison of three measuring methods for quantifying the amount of dust on the inner surface of ventilation ducts: 1) a vacuum test method; 2) a gravimetric tape method; and 3) an optical method. Thirteen recently constructed buildings were selected for the field test in the Helsinki metropolit...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2002.120106.x
更新日期:2002-03-01 00:00:00
abstract::The knowledge of exposure to the airborne particle emitted from three-dimensional (3D) printing activities is becoming a crucial issue due to the relevant spreading of such devices in recent years. To this end, a low-cost desktop 3D printer based on fused deposition modeling (FDM) principle was used. Particle number, ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12310
更新日期:2017-03-01 00:00:00
abstract:UNLABELLED:In the two decades since the first issue of Indoor Air, there have been over 250 peer-reviewed publications addressing chemical reactions among indoor pollutants. The present review has assembled and categorized these publications. It begins with a brief account of the state of our knowledge in 1991 regardin...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0668.2011.00713.x
更新日期:2011-06-01 00:00:00
abstract::This study assessed the collection efficiency (CE) of two popularly used sampling devices (BioSampler and Coriolis sampler) for fungal aerosols. Phosphate-buffered saline (PBS) supplemented with or without surfactant (Tween-20, Tween-80, or Triton X-100) and antifoam agent was prepared and used as collection liquids. ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12535
更新日期:2019-05-01 00:00:00
abstract:UNLABELLED:Ventilation performance and pollutant distribution in a traditional ceiling-type ventilation system, a top-return (TR)-type and a floor-return (FR)-type underfloor ventilation systems were performed in a controlled experimental room. Tracer gas method was utilized to determine the age of air and the contamin...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00248.x
更新日期:2004-10-01 00:00:00
abstract:UNLABELLED: Ingestion of indoor dust has been acknowledged as an important route of exposure to organic contaminants (OCs). We investigated the presence of polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), organophosphate flame retardants (OPFRs), polychlorinated biphenyls (PCBs), and ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00757.x
更新日期:2012-06-01 00:00:00
abstract::Few measurements of exposure to secondhand smoke (SHS) in close proximity to a smoker are available. Recent health studies have demonstrated an association between acute (<2 h) exposures to high concentrations of SHS and increased risk of cardiovascular and respiratory disease. We performed 15 experiments inside natur...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12057
更新日期:2014-04-01 00:00:00
abstract::Ventilation is pivotal in terms of securing optimum indoor air quality. In addition, it also has a major impact on energy use in buildings. It is important, therefore, that the role and impact of ventilation is fully understood and that ventilation is employed efficiently. The purpose of this paper is to review these ...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1034/j.1600-0668.2000.010003193.x
更新日期:2000-09-01 00:00:00
abstract:UNLABELLED:In case contaminants are found in enclosed environments such as aircraft cabins or buildings, it is useful to find the contaminant sources. One method to locate contaminant sources is by inverse computational fluid dynamics (CFD) modeling. As the inverse CFD modeling is ill posed, this paper has proposed to ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2006.00452.x
更新日期:2007-06-01 00:00:00
abstract:UNLABELLED:This paper presents the experimental and numerical modeling of contaminant dispersion in a full-scale environmental chamber with different room air distribution systems. For the experimental modeling, an area source with uniform emissions of a hypothetical contaminant (SF6) from the entire floor surface is d...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00383.x
更新日期:2005-10-01 00:00:00
abstract::Field measurements were collected through physical measurements and observations in the cities of Seoul, Korea; Eugene and Portland, Oregon; and Yokohama, Japan, during the fall, winter, and summer seasons from 2005 to 2006. A total of 1733 data sets were collected (Seoul - 713; Oregon - 807; Yokohama - 213) in variet...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2010.00705.x
更新日期:2011-08-01 00:00:00
abstract::As a basis for determining the lower limit of acceptable humidity in an indoor environment, experiments were conducted for 25 subjects to assess the maximum expected sensations of dryness, discomfort based on humidity, and intolerance based on humidity, under conditions of 26°C and 10% RH. As results, distinct negativ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12717
更新日期:2021-01-01 00:00:00
abstract::Dispersion characteristics of expiratory aerosols were investigated in an enclosure with two different idealized airflow patterns: the ceiling-return and the unidirectional downward. A multiphase numerical model, which was able to capture the polydispersity and evaporation features of the aerosols, was adopted. Experi...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2006.00426.x
更新日期:2006-08-01 00:00:00
abstract::While household air pollution from biomass fuel combustion has been linked to cardiovascular disease, the effects on cardiac structure and function have not been well described. We sought to determine the association between biomass fuel smoke exposure and cardiac structure and function by transthoracic echocardiograp...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12362
更新日期:2017-07-01 00:00:00
abstract::Personal exposure to total volatile organic compounds (TVOCs), benzene and toluene of 100 Milan office workers was assessed through personal air monitoring at home, in the office, and during commuting. Biological monitoring was performed by measuring blood benzene and toluene concentrations together with urinary trans...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2000.010004258.x
更新日期:2000-12-01 00:00:00
abstract::Indoor air quality (IAQ), as determined by the concentrations of indoor air pollutants, can be predicted using either physically based mechanistic models or statistical models that are driven by measured data. In comparison with mechanistic models mostly used in unoccupied or scenario-based environments, statistical m...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/ina.12580
更新日期:2019-09-01 00:00:00