Controlled experiments measuring personal exposure to PM2.5 in close proximity to cigarette smoking.

Abstract:

:Few measurements of exposure to secondhand smoke (SHS) in close proximity to a smoker are available. Recent health studies have demonstrated an association between acute (<2 h) exposures to high concentrations of SHS and increased risk of cardiovascular and respiratory disease. We performed 15 experiments inside naturally ventilated homes and 16 in outdoor locations, each with 2-4 non-smokers sitting near a cigarette smoker. The smoker's and non-smokers' real-time exposures to PM2.5 from SHS were measured by using TSI SidePak monitors to sample their breathing zones. In 87% of the residential indoor experiments, the smoker received the highest average exposure to SHS, with PM2.5 concentrations ranging from 50-630 μg/m(3) . During the active smoking period, individual non-smokers sitting within approximately 1 m of a smoker had average SHS exposures ranging from negligible up to >160 μg/m(3) of PM2.5 . The average incremental exposure of the non-smokers was higher indoors (42 μg/m(3) , n = 35) than outdoors (29 μg/m(3) , n = 47), but the overall indoor and outdoor frequency distributions were similar. The 10-s PM2.5 averages during the smoking periods showed great variability, with multiple high concentrations of short duration (microplumes) both indoors and outdoors.

journal_name

Indoor Air

journal_title

Indoor air

authors

Acevedo-Bolton V,Ott WR,Cheng KC,Jiang RT,Klepeis NE,Hildemann LM

doi

10.1111/ina.12057

subject

Has Abstract

pub_date

2014-04-01 00:00:00

pages

199-212

issue

2

eissn

0905-6947

issn

1600-0668

journal_volume

24

pub_type

杂志文章
  • A review of ventilation and the quality of ventilation air.

    abstract::Ventilation is pivotal in terms of securing optimum indoor air quality. In addition, it also has a major impact on energy use in buildings. It is important, therefore, that the role and impact of ventilation is fully understood and that ventilation is employed efficiently. The purpose of this paper is to review these ...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1034/j.1600-0668.2000.010003193.x

    authors: Liddament MW

    更新日期:2000-09-01 00:00:00

  • Field study on occupant comfort and the office thermal environment in rooms with displacement ventilation.

    abstract:UNLABELLED:A field survey of occupants' response to the indoor environment in 10 office buildings with displacement ventilation was performed. The response of 227 occupants was analyzed. About 24% of the occupants in the survey complained that they were daily bothered by draught, mainly at the lower leg. Vertical air t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00337.x

    authors: Melikov A,Pitchurov G,Naydenov K,Langkilde G

    更新日期:2005-06-01 00:00:00

  • Personal measurement of exposure to black carbon and ultrafine particles in schoolchildren from PARIS cohort (Paris, France).

    abstract::This study aimed to measure in French children personal exposure concentrations of black carbon (BC) and ultrafine particles (UFP) and to quantify the contribution of different microenvironments (home, school, places of extracurricular activities, transport) to their total exposure. It was conducted on 96 9-year-old c...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12358

    authors: Paunescu AC,Attoui M,Bouallala S,Sunyer J,Momas I

    更新日期:2017-07-01 00:00:00

  • Effects of energy retrofits on Indoor Air Quality in multifamily buildings.

    abstract::We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12555

    authors: Du L,Leivo V,Prasauskas T,Täubel M,Martuzevicius D,Haverinen-Shaughnessy U

    更新日期:2019-07-01 00:00:00

  • Association of gas cooking with children's respiratory health: results from GINIplus and LISAplus birth cohort studies.

    abstract:UNLABELLED:Previous studies have found inconsistent results on the association between asthma in children and gas cooking emissions. We aimed to assess the effects of the long-term exposure to gas cooking on the onset of asthma and respiratory symptoms, focusing on wheezing, in children from two German birth cohorts: L...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2012.00784.x

    authors: Casas L,Tischer C,Tiesler C,Brüske I,Koletzko S,Bauer CP,Wichmann HE,von Berg A,Berdel D,Krämer U,Schaaf B,Lehmann I,Herbarth O,Heinrich J,GINIplus and LISAplus Study Group.

    更新日期:2012-12-01 00:00:00

  • Spatiotemporally resolved black carbon concentration, schoolchildren's exposure and dose in Barcelona.

    abstract::At city level, personal monitoring is the best way to assess people's exposure. However, it is usually estimated from a few monitoring stations. Our aim was to determine the exposure to black carbon (BC) and BC dose for 45 schoolchildren with portable microaethalometers and to evaluate the relationship between persona...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12214

    authors: Rivas I,Donaire-Gonzalez D,Bouso L,Esnaola M,Pandolfi M,de Castro M,Viana M,Àlvarez-Pedrerol M,Nieuwenhuijsen M,Alastuey A,Sunyer J,Querol X

    更新日期:2016-06-01 00:00:00

  • Presence and variability of culturable bioaerosols in three multi-family apartment buildings with different ventilation systems in the Northeastern US.

    abstract::Bioaerosol concentrations in residential buildings located in the Northeastern US have not been widely studied. Here, in 2011-2015, we studied the presence and seasonal variability of culturable fungi and bacteria in three multi-family apartment buildings and correlated the bioaerosol concentrations with building vent...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12743

    authors: Myers NT,Calderón L,Pavilonis B,Wang Z,Xiong Y,Sorensen-Allacci M,Plotnik D,Senick J,Gong J,Krogmann U,Andrews CJ,Mainelis G

    更新日期:2020-09-15 00:00:00

  • Ultrafine particles from electric appliances and cooking pans: experiments suggesting desorption/nucleation of sorbed organics as the primary source.

    abstract::Ultrafine particles are observed when metal surfaces, such as heating elements in electric appliances, or even empty cooking pans, are heated. The source of the particles has not been identified. We present evidence that particles >10 nm are not emitted directly from the heating elements or the metal surfaces. Using r...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12163

    authors: Wallace LA,Ott WR,Weschler CJ

    更新日期:2015-10-01 00:00:00

  • The field comparison of three measuring techniques for evaluation of the surface dust level in ventilation ducts.

    abstract::This paper reports the comparison of three measuring methods for quantifying the amount of dust on the inner surface of ventilation ducts: 1) a vacuum test method; 2) a gravimetric tape method; and 3) an optical method. Thirteen recently constructed buildings were selected for the field test in the Helsinki metropolit...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.120106.x

    authors: Holopainen R,Asikainen V,Pasanen P,Seppänen O

    更新日期:2002-03-01 00:00:00

  • Early age exposure to moisture damage and systemic inflammation at the age of 6 years.

    abstract::Cross-sectional studies have shown that exposure to indoor moisture damage and mold may be associated with subclinical inflammation. Our aim was to determine whether early age exposure to moisture damage or mold is prospectively associated with subclinical systemic inflammation or with immune responsiveness in later c...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12454

    authors: Karvonen AM,Tischer C,Kirjavainen PV,Roponen M,Hyvärinen A,Illi S,Mustonen K,Pfefferle PI,Renz H,Remes S,Schaub B,von Mutius E,Pekkanen J

    更新日期:2018-05-01 00:00:00

  • Indoor/outdoor relationships of carbon monoxide and oxides of nitrogen in domestic homes with roadside, urban and rural locations in a central Indian region.

    abstract:UNLABELLED:Indoor air quality (IAQ) has been a matter of public concern these days whereas air pollution is normally monitored outdoors as part of obligations under the National air quality strategies. Much little is known about levels of air pollution indoors. Simultaneous measurements of indoor and outdoor carbon mon...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00311.x

    authors: Lawrence AJ,Masih A,Taneja A

    更新日期:2005-04-01 00:00:00

  • Semivolatile organic compounds in French schools: Partitioning between the gas phase, airborne particles and settled dust.

    abstract::The indoor environmental quality in classrooms can largely affect children's daily exposure to indoor chemicals in schools. To date, there has not been a comprehensive study of the concentrations of semivolatile organic compounds (SVOCs) in French schools. Therefore, the French Observatory for Indoor Air Quality (OQAI...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12724

    authors: Wei W,Dassonville C,Sivanantham S,Gregoire A,Mercier F,Le Bot B,Malingre L,Ramalho O,Derbez M,Mandin C

    更新日期:2021-01-01 00:00:00

  • Influence of local airflow on the pollutant emission from indoor building surfaces.

    abstract::This article reports the results of an investigation, based on fundamental fluid dynamics and mass transfer theory, carried out to obtain a general understanding of the mechanisms involved in the emissions from building materials in ventilated rooms. In addition, a generally applicable method for the prediction of sur...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.011003162.x

    authors: Topp C,Nielsen PV,Heiselberg P

    更新日期:2001-09-01 00:00:00

  • Co-occupant's exposure to exhaled pollutants with two types of personalized ventilation strategies under mixing and displacement ventilation systems.

    abstract::Personalized ventilation (PV) system in conjunction with total ventilation system can provide cleaner inhaled air for the user. Concerns still exist about whether the normally protecting PV device, on the other hand, facilitates the dispersion of infectious agents generated by its user. In this article, two types of P...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12005

    authors: Li X,Niu J,Gao N

    更新日期:2013-04-01 00:00:00

  • Characterizing ultrafine particles and other air pollutants at five schools in South Texas.

    abstract:UNLABELLED:This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00738.x

    authors: Zhang Q,Zhu Y

    更新日期:2012-02-01 00:00:00

  • Study of effect of adsorptive building material on formaldehyde concentrations: development of measuring methods and modeling of adsorption phenomena.

    abstract:UNLABELLED:In this paper, a method is developed to assess the performance of adsorptive building materials that are used for reducing indoor pollutant concentrations. Mass transfer has a great influence on the materials' performance. To control the mass transfer rate precisely in the performance test, the authors have ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00316.x

    authors: Ataka Y,Kato S,Murakami S,Zhu Q,Ito K,Yokota T

    更新日期:2004-01-01 00:00:00

  • Determinants, reproducibility, and seasonal variation of bacterial cell wall components and viable counts in house dust.

    abstract::The objectives of this study were (i) to assess the determinants that affect concentrations of the bacterial cell wall components 3-hydroxy fatty acids (3-OH FAs) and muramic acid and of total viable bacteria and actinomycetes in house dust; and (ii) to examine the seasonal variation and reproducibility of these bacte...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12141

    authors: Leppänen HK,Täubel M,Roponen M,Vepsäläinen A,Rantakokko P,Pekkanen J,Nevalainen A,von Mutius E,Hyvärinen A

    更新日期:2015-06-01 00:00:00

  • Risk assessment of formaldehyde in typical office buildings in Taiwan.

    abstract::Our study conducts a series of investigations in five office buildings chosen according to the types of construction, ventilation, and building age. Formaldehyde was measured by continuous photoacoustic Multi-Gas monitor Type 1302 (Brüel & Kjaer). The 8-h average concentrations in working hours were used to estimate t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2003.00205.x

    authors: Wu PC,Li YY,Lee CC,Chiang CM,Su HJ

    更新日期:2003-12-01 00:00:00

  • A simplified approach to describe complex diffusers in displacement ventilation for CFD simulations.

    abstract:UNLABELLED:With the capability to improve indoor air quality while simultaneously reducing energy demand, displacement ventilation is becoming popular. However, the numerical simulation of air distribution in an indoor space with displacement ventilation using computational fluid dynamics (CFD) is challenging because o...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2009.00590.x

    authors: Zhang TT,Lee K,Chen QY

    更新日期:2009-06-01 00:00:00

  • Respiratory effects of experimental exposure to office dust.

    abstract:UNLABELLED:The aim of this experiment was to test if healthy persons respond to exposures to normal office dust with objective or subjective effects in a dose-related way. If they did, the importance of their personal characteristics should be investigated. This paper presents the results related to respiratory effects...

    journal_title:Indoor air

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1600-0668.2004.00252.x

    authors: Mølhave L,Kjaergaard SK,Attermann J

    更新日期:2004-12-01 00:00:00

  • Indoor gaseous air pollutants determinants in office buildings-The OFFICAIR project.

    abstract::The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12609

    authors: Spinazzè A,Campagnolo D,Cattaneo A,Urso P,Sakellaris IA,Saraga DE,Mandin C,Canha N,Mabilia R,Perreca E,Mihucz VG,Szigeti T,Ventura G,de Oliveira Fernandes E,de Kluizenaar Y,Cornelissen E,Hänninen O,Carrer P,Wolkoff P

    更新日期:2020-01-01 00:00:00

  • Quantitative filter forensics with residential HVAC filters to assess indoor concentrations.

    abstract::Analysis of the dust from heating, ventilation, and air conditioning (HVAC) filters is a promising long-term sampling method to characterize airborne particle-bound contaminants. This filter forensics (FF) approach provides valuable insights about differences between buildings, but does not allow for an estimation of ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12536

    authors: Givehchi R,Maestre JP,Bi C,Wylie D,Xu Y,Kinney KA,Siegel JA

    更新日期:2019-05-01 00:00:00

  • Machine learning and statistical models for predicting indoor air quality.

    abstract::Indoor air quality (IAQ), as determined by the concentrations of indoor air pollutants, can be predicted using either physically based mechanistic models or statistical models that are driven by measured data. In comparison with mechanistic models mostly used in unoccupied or scenario-based environments, statistical m...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/ina.12580

    authors: Wei W,Ramalho O,Malingre L,Sivanantham S,Little JC,Mandin C

    更新日期:2019-09-01 00:00:00

  • Removal of viable bioaerosol particles with a low-efficiency HVAC filter enhanced by continuous emission of unipolar air ions.

    abstract:UNLABELLED:Continuous emission of unipolar ions has been shown to improve the performance of respirators and stationary filters challenged with non-biological particles. In this study, we investigated the ion-induced enhancement effect while challenging a low-efficiency heating, ventilation and air-conditioning (HVAC) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00512.x

    authors: Huang R,Agranovski I,Pyankov O,Grinshpun S

    更新日期:2008-04-01 00:00:00

  • Particulate matter from indoor environments of classroom induced higher cytotoxicity and leakiness in human microvascular endothelial cells in comparison with those collected from corridor.

    abstract::We investigated the physicochemical properties (size, shape, elemental composition, and endotoxin) of size resolved particulate matter (PM) collected from the indoor and corridor environments of classrooms. A comparative hazard profiling of these PM was conducted using human microvascular endothelial cells (HMVEC). Ox...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12341

    authors: Chua ML,Setyawati MI,Li H,Fang CHY,Gurusamy S,Teoh FTL,Leong DT,George S

    更新日期:2017-05-01 00:00:00

  • Measured moisture in buildings and adverse health effects: A review.

    abstract::It has not yet been possible to quantify dose-related health risks attributable to indoor dampness or mold (D/M), to support setting specific health-related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of q...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/ina.12464

    authors: Mendell MJ,Macher JM,Kumagai K

    更新日期:2018-07-01 00:00:00

  • Levels and sources of volatile organic compounds in homes of children with asthma.

    abstract:UNLABELLED:Many volatile organic compounds (VOCs) are classified as known or possible carcinogens, irritants, and toxicants, and VOC exposure has been associated with the onset and exacerbation of asthma. This study characterizes VOC levels in 126 homes of children with asthma in Detroit, Michigan, USA. The total targe...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12086

    authors: Chin JY,Godwin C,Parker E,Robins T,Lewis T,Harbin P,Batterman S

    更新日期:2014-08-01 00:00:00

  • Experimental study of ventilation performance and contaminant distribution of underfloor ventilation systems vs. traditional ceiling-based ventilation system.

    abstract:UNLABELLED:Ventilation performance and pollutant distribution in a traditional ceiling-type ventilation system, a top-return (TR)-type and a floor-return (FR)-type underfloor ventilation systems were performed in a controlled experimental room. Tracer gas method was utilized to determine the age of air and the contamin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00248.x

    authors: Chao CY,Wan MP

    更新日期:2004-10-01 00:00:00

  • Indoor visible mold and mold odor are associated with new-onset childhood wheeze in a dose-dependent manner.

    abstract::Evidence is accumulating that indoor dampness and mold are associated with the development of asthma. The underlying mechanisms remain unknown. New Zealand has high rates of both asthma and indoor mold and is ideally placed to investigate this. We conducted an incident case-control study involving 150 children with ne...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12413

    authors: Shorter C,Crane J,Pierse N,Barnes P,Kang J,Wickens K,Douwes J,Stanley T,Täubel M,Hyvärinen A,Howden-Chapman P,Wellington Region General Practitioner Research Network.

    更新日期:2018-01-01 00:00:00

  • Survey of the reliability of carbon monoxide alarms deployed in domestic homes and efficacy of use by consumers.

    abstract::Carbon monoxide (CO) alarms are extensively used in domestic premises in the UK to help protect against CO poisoning. Their expected lifetime has been increasing, and some current models now have a replacement period of more than 6 years under normal operation. However, concerns have been expressed as to the reliabili...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12022

    authors: Naylor S,Walsh PT,Dowker KP

    更新日期:2013-08-01 00:00:00