Indoor gaseous air pollutants determinants in office buildings-The OFFICAIR project.

Abstract:

:The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and VOCs in 37 newly built or recently retrofitted office buildings across 8 European countries in summer and winter and (b) the collection of information on building and offices' characteristics using checklists. Linear mixed models for repeated measurements were applied to identify the main factors affecting the measured concentrations of selected indoor air pollutants (IAPs). Several associations between aldehydes and VOCs concentrations and buildings' structural characteristic or occupants' activity patterns were identified. The aldehyde and VOC determinants in office buildings include building and furnishing materials, indoor climate characteristics (room temperature and relative humidity), the use of consumer products (eg, cleaning and personal care products, office equipment), as well as the presence of outdoor sources in the proximity of the buildings (ie, vehicular traffic). Results also showed that determinants of indoor air concentrations varied considerably among different type of pollutants.

journal_name

Indoor Air

journal_title

Indoor air

authors

Spinazzè A,Campagnolo D,Cattaneo A,Urso P,Sakellaris IA,Saraga DE,Mandin C,Canha N,Mabilia R,Perreca E,Mihucz VG,Szigeti T,Ventura G,de Oliveira Fernandes E,de Kluizenaar Y,Cornelissen E,Hänninen O,Carrer P,Wolkoff P

doi

10.1111/ina.12609

subject

Has Abstract

pub_date

2020-01-01 00:00:00

pages

76-87

issue

1

eissn

0905-6947

issn

1600-0668

journal_volume

30

pub_type

杂志文章
  • Comparison of disinfection performance of UVC-LED and conventional upper-room UVGI systems.

    abstract::We developed a novel, compact upper-room ultraviolet germicidal irradiation system with light-emitting diode sources (UR-UVGI-LED) to enhance the disinfection of bioaerosols in an enclosed room space. Its effectiveness was evaluated and compared with the conventional upper-room ultraviolet germicidal irradiation syste...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12619

    authors: Nunayon SS,Zhang H,Lai ACK

    更新日期:2020-01-01 00:00:00

  • Assessment of human exposure to indoor organic contaminants via dust ingestion in Pakistan.

    abstract:UNLABELLED:  Ingestion of indoor dust has been acknowledged as an important route of exposure to organic contaminants (OCs). We investigated the presence of polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), organophosphate flame retardants (OPFRs), polychlorinated biphenyls (PCBs), and ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00757.x

    authors: Ali N,Van den Eede N,Dirtu AC,Neels H,Covaci A

    更新日期:2012-06-01 00:00:00

  • Continuous measurement of reactive oxygen species inside and outside of a residential house during summer.

    abstract::Reactive oxygen species (ROS) are an important contributor to adverse health effects associated with ambient air pollution. Despite infiltration of ROS from outdoors, and possible indoor sources (eg, combustion), there are limited data available on indoor ROS. In this study, part of the second phase of Air Composition...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12789

    authors: Eftekhari A,Fortenberry CF,Williams BJ,Walker MJ,Dang A,Pfaff A,Ercal N,Morrison GC

    更新日期:2021-01-23 00:00:00

  • Endotoxin, extracellular polysaccharides, and β(1-3)-glucan concentrations in dust and their determinants in four European birth cohorts: results from the HITEA project.

    abstract:UNLABELLED:Early-life exposure to microbial agents may play a protective role in asthma and allergies development. Geographical differences in the prevalence of these diseases exist, but the differences in early-life indoor microbial agent levels and their determinants have been hardly studied. We aimed to describe the...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12017

    authors: Casas L,Tischer C,Wouters IM,Valkonen M,Gehring U,Doekes G,Torrent M,Pekkanen J,Garcia-Esteban R,Hyvärinen A,Heinrich J,Sunyer J

    更新日期:2013-06-01 00:00:00

  • The relationship between measured moisture conditions and fungal concentrations in water-damaged building materials.

    abstract::We determined the moisture levels, relative humidity (RH) or moisture content (MC) of materials, and concentrations of culturable fungi, actinomycetes and total spores as well as a composition of fungal flora in 122 building material samples collected from 18 moisture problem buildings. The purpose of this work was to...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2000.010002111.x

    authors: Pasanen AL,Rautiala S,Kasanen JP,Raunio P,Rantamäki J,Kalliokoski P

    更新日期:2000-06-01 00:00:00

  • Experimental validation of a computational fluid dynamics model for IAQ applications in ice rink arenas.

    abstract::Many ice rink arenas have ice resurfacing equipment that uses fossil fuel as power. The combustion byproducts are a major source of contamination. Ventilation along with other pollution source control measures is the most widely applied strategy to lower the contaminant level below the threshold limit and maintain acc...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.110206.x

    authors: Yang C,Demokritou P,Chen Q,Spengler J

    更新日期:2001-06-01 00:00:00

  • Particle size distributions and concentrations of airborne endotoxin using novel collection methods in homes during the winter and summer seasons.

    abstract:UNLABELLED:A comparison study of novel collection methods for airborne bacteria and endotoxin was performed in an environmentally controlled chamber and in pilot-field studies. Airborne particulate matter was collected in swirling liquid impingers, air-monitoring filter cassettes, and with a micro-orifice uniform depos...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00419.x

    authors: Kujundzic E,Hernandez M,Miller SL

    更新日期:2006-06-01 00:00:00

  • Study on the lower limit of indoor humidity subject experiments on psychological responses.

    abstract::As a basis for determining the lower limit of acceptable humidity in an indoor environment, experiments were conducted for 25 subjects to assess the maximum expected sensations of dryness, discomfort based on humidity, and intolerance based on humidity, under conditions of 26°C and 10% RH. As results, distinct negativ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12717

    authors: Takada S

    更新日期:2021-01-01 00:00:00

  • Comparison of risk factor profiles concerning self-reported skin complaints and objectively determined skin symptoms in German office workers.

    abstract::The correspondence between impact factor profiles of self-reported skin sensation and of objectively determined skin symptoms was examined using data from the ProKlimA project (1994-1999). A sub-sample of 925 office workers participated in measurements of skin hydration and sebum content and responded to a questionnai...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1046/j.1600-0668.2003.00222.x

    authors: Brasche S,Bullinger M,Schwab R,Gebhardt H,Herzog V,Bischof W

    更新日期:2004-04-01 00:00:00

  • Productivity and fatigue.

    abstract:UNLABELLED:In studying productivity, effects of environmental factors have focused only on performance. However, previous studies of the impact of the environment upon performance of mental tasks generally conclude that productivity research is somewhat confusing because the results are sometimes conflicting. In experi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00281.x

    authors: Tanabe S,Nishihara N

    更新日期:2004-01-01 00:00:00

  • Dampness at dorm and its associations with allergy and airways infection among college students in China: a cross-sectional study.

    abstract:UNLABELLED:A cross-sectional study was carried out at Tianjin University campus, China, from February 21 to June10, 2006, to survey the association between dampness in dorms and allergy and airways infection among college students. The health and dampness condition were self-reported by 3436 students living in 1511 dor...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00577.x

    authors: Sun Y,Zhang Y,Sundell J,Fan Z,Bao L

    更新日期:2009-04-01 00:00:00

  • Biomass fuel smoke exposure was associated with adverse cardiac remodeling and left ventricular dysfunction in Peru.

    abstract::While household air pollution from biomass fuel combustion has been linked to cardiovascular disease, the effects on cardiac structure and function have not been well described. We sought to determine the association between biomass fuel smoke exposure and cardiac structure and function by transthoracic echocardiograp...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12362

    authors: Burroughs Peña MS,Velazquez EJ,Rivera JD,Alenezi F,Wong C,Grigsby M,Davila-Roman VG,Gilman RH,Miranda JJ,Checkley W

    更新日期:2017-07-01 00:00:00

  • Quantitative filter forensics with residential HVAC filters to assess indoor concentrations.

    abstract::Analysis of the dust from heating, ventilation, and air conditioning (HVAC) filters is a promising long-term sampling method to characterize airborne particle-bound contaminants. This filter forensics (FF) approach provides valuable insights about differences between buildings, but does not allow for an estimation of ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12536

    authors: Givehchi R,Maestre JP,Bi C,Wylie D,Xu Y,Kinney KA,Siegel JA

    更新日期:2019-05-01 00:00:00

  • Indoor air pollution in developing countries: recommendations for research.

    abstract::Available studies indicate that indoor air pollution (IAP) from household cooking and space heating apparently causes substantial ill-health in developing countries where the majority of households rely on solid fuels (coal or biomass as wood, crop residues, and dung), but there are many remaining uncertainties. To pi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.01137.x

    authors: Smith KR

    更新日期:2002-09-01 00:00:00

  • Airborne particle emission of a commercial 3D printer: the effect of filament material and printing temperature.

    abstract::The knowledge of exposure to the airborne particle emitted from three-dimensional (3D) printing activities is becoming a crucial issue due to the relevant spreading of such devices in recent years. To this end, a low-cost desktop 3D printer based on fused deposition modeling (FDM) principle was used. Particle number, ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12310

    authors: Stabile L,Scungio M,Buonanno G,Arpino F,Ficco G

    更新日期:2017-03-01 00:00:00

  • Removal of viable bioaerosol particles with a low-efficiency HVAC filter enhanced by continuous emission of unipolar air ions.

    abstract:UNLABELLED:Continuous emission of unipolar ions has been shown to improve the performance of respirators and stationary filters challenged with non-biological particles. In this study, we investigated the ion-induced enhancement effect while challenging a low-efficiency heating, ventilation and air-conditioning (HVAC) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00512.x

    authors: Huang R,Agranovski I,Pyankov O,Grinshpun S

    更新日期:2008-04-01 00:00:00

  • Prevalence and risk factors associated with nonspecific building-related symptoms in office employees in Japan: relationships between work environment, Indoor Air Quality, and occupational stress.

    abstract::A nationwide cross-sectional study of 3335 employees was conducted in 320 offices in Japan to estimate the prevalence of building-related symptoms (BRSs) and determine the risk factors related to work environment, Indoor Air Quality, and occupational stress. Data were collected through self-administered questionnaires...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12158

    authors: Azuma K,Ikeda K,Kagi N,Yanagi U,Osawa H

    更新日期:2015-10-01 00:00:00

  • Comparing zonal and CFD model predictions of isothermal indoor airflows to experimental data.

    abstract::It is inappropriate to use the assumption of instantaneously well-mixed zones to model airflows and pollutant transport in large indoor spaces. We investigate two approaches for describing the details of airflows in large indoor spaces, for accuracy and suitability for integration with multi-zone infiltration models. ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00160.x

    authors: Mora L,Gadgil AJ,Wurtz E

    更新日期:2003-06-01 00:00:00

  • Quantitative aerobiologic analysis of an influenza human challenge-transmission trial.

    abstract::Despite evidence that airborne transmission contributes to influenza epidemics, limited knowledge of the infectiousness of human influenza cases hinders pandemic preparedness. We used airborne viral source strength and indoor CO2 monitoring from the largest human influenza challenge-transmission trial (EMIT: Evaluatin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12701

    authors: Bueno de Mesquita PJ,Noakes CJ,Milton DK

    更新日期:2020-11-01 00:00:00

  • Chamber testing of adsorption of volatile organic compounds (VOCs) on material surfaces.

    abstract::A simple test chamber method to quantify adsorption and desorption of organic compounds on material surfaces is described. Important environmental parameters such as temperature, relative humidity and air velocity were varied and controlled independently around typical indoor values. Experiments were performed with al...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.1999.t01-3-00002.x

    authors: Jørgensen RB,Bjørseth O,Malvik B

    更新日期:1999-03-01 00:00:00

  • Droplet fate in indoor environments, or can we prevent the spread of infection?

    abstract:UNLABELLED:When considering how people are infected and what can be done to prevent the infections, answers from many disciplines are sought: microbiology, epidemiology, medicine, engineering, and physics. There are many pathways to infection spread, and among the most significant from the epidemiological point of view...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2006.00432.x

    authors: Morawska L

    更新日期:2006-10-01 00:00:00

  • Ultrafine, fine, and black carbon particle concentrations in California child-care facilities.

    abstract::Although many U.S. children spend time in child care, little information exists on exposures to airborne particulate matter (PM) in this environment, even though PM may be associated with asthma and other respiratory illness, which is a key concern for young children. To address this data gap, we measured ultrafine pa...

    journal_title:Indoor air

    pub_type: 杂志文章,多中心研究

    doi:10.1111/ina.12408

    authors: Gaspar FW,Maddalena R,Williams J,Castorina R,Wang ZM,Kumagai K,McKone TE,Bradman A

    更新日期:2018-01-01 00:00:00

  • Relationships between estimated flame retardant emissions and levels in indoor air and house dust.

    abstract::A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12332

    authors: Liagkouridis I,Cequier E,Lazarov B,Palm Cousins A,Thomsen C,Stranger M,Cousins IT

    更新日期:2017-05-01 00:00:00

  • Association of size-fractionated indoor particulate matter and black carbon with heart rate variability in healthy elderly women in Beijing.

    abstract::Associations between size-fractionated indoor particulate matter (PM) and black carbon (BC) and heart rate variability (HRV) and heart rate (HR) in elderly women remain unclear. Twenty-nine healthy elderly women were measured for 24-hour HRV/HR indices. Real-time size-fractionated indoor PM and BC were monitored on th...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12449

    authors: Dong W,Pan L,Li H,Miller MR,Loh M,Wu S,Xu J,Yang X,Shan J,Chen Y,Deng F,Guo X

    更新日期:2018-05-01 00:00:00

  • Formaldehyde as a basis for residential ventilation rates.

    abstract::Traditionally, houses in the US have been ventilated by passive infiltration in combination with active window opening. However in recent years, the construction quality of residential building envelopes has been improved to reduce infiltration, and the use of windows for ventilation also may have decreased due to a n...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1046/j.1600-0668.2003.00188.x

    authors: Sherman MH,Hodgson AT

    更新日期:2004-02-01 00:00:00

  • Effectiveness of a portable air cleaner in removing aerosol particles in homes close to highways.

    abstract::Outdoor traffic-related airborne particles can infiltrate a building and adversely affect the indoor air quality. Limited information is available on the effectiveness of high efficiency particulate air (HEPA) filtration of traffic-related particles. Here, we investigated the effectiveness of portable HEPA air cleaner...

    journal_title:Indoor air

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/ina.12502

    authors: Cox J,Isiugo K,Ryan P,Grinshpun SA,Yermakov M,Desmond C,Jandarov R,Vesper S,Ross J,Chillrud S,Dannemiller K,Reponen T

    更新日期:2018-11-01 00:00:00

  • Exposure to ultrafine particles in children until 18 years of age: A systematic review.

    abstract::Airborne ultrafine particles (UFP) have been related to adverse health effects, but exposure in vulnerable population groups such as children is still not well understood. We aim to review the scientific literature regarding personal exposure to UFP in different microenvironments in populations until 18 years of age. ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12620

    authors: García-Hernández C,Ferrero A,Estarlich M,Ballester F

    更新日期:2020-01-01 00:00:00

  • Performance evaluation of a novel personalized ventilation-personalized exhaust system for airborne infection control.

    abstract::In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)-personalized exhaust (PE) system...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12127

    authors: Yang J,Sekhar SC,Cheong KW,Raphael B

    更新日期:2015-04-01 00:00:00

  • Human convection flow in spaces with and without ventilation: personal exposure to floor-released particles and cough-released droplets.

    abstract:UNLABELLED:The effects of the human convective boundary layer (CBL), room airflow patterns, and their velocities on personal exposure are examined. Two pollutants are studied which simulate particles released from the feet and generated at distances of 2 and 3 m by a human cough. A thermal manikin whose body shape, siz...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12177

    authors: Licina D,Melikov A,Pantelic J,Sekhar C,Tham KW

    更新日期:2015-12-01 00:00:00

  • Field study on occupant comfort and the office thermal environment in rooms with displacement ventilation.

    abstract:UNLABELLED:A field survey of occupants' response to the indoor environment in 10 office buildings with displacement ventilation was performed. The response of 227 occupants was analyzed. About 24% of the occupants in the survey complained that they were daily bothered by draught, mainly at the lower leg. Vertical air t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00337.x

    authors: Melikov A,Pitchurov G,Naydenov K,Langkilde G

    更新日期:2005-06-01 00:00:00