Respiratory effects of experimental exposure to office dust.

Abstract:

UNLABELLED:The aim of this experiment was to test if healthy persons respond to exposures to normal office dust with objective or subjective effects in a dose-related way. If they did, the importance of their personal characteristics should be investigated. This paper presents the results related to respiratory effects caused by exposures to office dust. The experiment compared the responses of 24 healthy non-sensitive adult subjects with no known hyperreactivity to exposure to normal office dust in the air at 136 and 390 microg/m3 with their responses in clean air. The exposure duration was 5.25 h in a climate chamber under controlled conditions. The dust had no major identifiable specific reactive compounds. There were no direct effects of dust exposures on nasal lavages or rhinometry. The overall indications of the experiment are that healthy subjects without any hypersensitive reactions seem to respond to exposure to house dust without specific reactive components. The only effect indicated was on eosinophil cationic protein in nasal lavages and peak flow. A delayed effect on peak expiratory flow was observed the day after the exposure. Other effects were seen but in opposite direction of expectations. Several deviations from the original design of the experiment prevent any definitive conclusions from being made from these findings before they have been confirmed in future experiments to come. PRACTICAL IMPLICATIONS:Reflecting the exploratory status of the study its major implication is to point at possible future hypotheses. The study implies that office dust may have an effect on occupants' lung function even at concentrations found in normal indoor environments. The influences of a multitude of response modifying variables were tested but no consistent pattern was found. The study does therefore not identify a specific risk group but suggests that among normal non-sensitized subjects most of the traditional risk factors can be rejected as single responsible risk factor.

journal_name

Indoor Air

journal_title

Indoor air

authors

Mølhave L,Kjaergaard SK,Attermann J

doi

10.1111/j.1600-0668.2004.00252.x

subject

Has Abstract

pub_date

2004-12-01 00:00:00

pages

376-84

issue

6

eissn

0905-6947

issn

1600-0668

pii

INA252

journal_volume

14

pub_type

临床试验,杂志文章,随机对照试验
  • Machine learning and statistical models for predicting indoor air quality.

    abstract::Indoor air quality (IAQ), as determined by the concentrations of indoor air pollutants, can be predicted using either physically based mechanistic models or statistical models that are driven by measured data. In comparison with mechanistic models mostly used in unoccupied or scenario-based environments, statistical m...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/ina.12580

    authors: Wei W,Ramalho O,Malingre L,Sivanantham S,Little JC,Mandin C

    更新日期:2019-09-01 00:00:00

  • Hygroscopic fine mode particle deposition on electronic circuits and resulting degradation of circuit performance: an experimental study.

    abstract::A portion of electronic equipment failures is a consequence of particle deposition on electronic circuits in normal indoor environments. Deposited hygroscopic particles reduce the electrical isolation (EI) between conductors. In laboratory experiments, we investigated the mechanisms, locations, and effects of particle...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2000.010001047.x

    authors: Litvak A,Gadgil AJ,Fisk WJ

    更新日期:2000-03-01 00:00:00

  • Characterization of endotoxin and 3-hydroxy fatty acid levels in air and settled dust from commercial aircraft cabins.

    abstract::Endotoxin was measured in air and dust samples collected during four commercial aircraft flights. Samples were analyzed for endotoxin biological activity using the Limulus assay. 3-hydroxy fatty acids (3-OH FA) of carbon chain lengths C10:0-C18:0 were determined in dust by gas chromatography-ion trap tandem mass spect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00175.x

    authors: Hines CJ,Waters MA,Larsson L,Petersen MR,Saraf A,Milton DK

    更新日期:2003-06-01 00:00:00

  • Variations of formaldehyde and VOC levels during 3 years in new and older homes.

    abstract:UNLABELLED:Indoor air organic compounds were continuously monitored during 3 years in new and older homes which were voluntarily selected throughout countries. The levels of volatile organic compounds (VOCs) in the new homes decreased markedly after 1 year, and steady emissions of VOCs were obtained in the initial mont...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00408.x

    authors: Park JS,Ikeda K

    更新日期:2006-04-01 00:00:00

  • Ultrafine, fine, and black carbon particle concentrations in California child-care facilities.

    abstract::Although many U.S. children spend time in child care, little information exists on exposures to airborne particulate matter (PM) in this environment, even though PM may be associated with asthma and other respiratory illness, which is a key concern for young children. To address this data gap, we measured ultrafine pa...

    journal_title:Indoor air

    pub_type: 杂志文章,多中心研究

    doi:10.1111/ina.12408

    authors: Gaspar FW,Maddalena R,Williams J,Castorina R,Wang ZM,Kumagai K,McKone TE,Bradman A

    更新日期:2018-01-01 00:00:00

  • Assessment through environmental and biological measurements of total daily exposure to volatile organic compounds of office workers in Milan, Italy.

    abstract::Personal exposure to total volatile organic compounds (TVOCs), benzene and toluene of 100 Milan office workers was assessed through personal air monitoring at home, in the office, and during commuting. Biological monitoring was performed by measuring blood benzene and toluene concentrations together with urinary trans...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2000.010004258.x

    authors: Carrer P,Maroni M,Alcini D,Cavallo D,Fustinoni S,Lovato L,Visigalli F

    更新日期:2000-12-01 00:00:00

  • Measured concentrations of combustion gases from the use of unvented gas fireplaces.

    abstract:UNLABELLED:Measurements of combustion product concentrations were taken in 30 homes where unvented gas fireplaces were used. Measurements of CO, CO(2), NO(x), NO(2) , O(2) (depletion), and water vapor were taken at 1-min interval. The analyzers were calibrated with certified calibration gases for each placement and wer...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00659.x

    authors: Francisco PW,Gordon JR,Rose B

    更新日期:2010-10-01 00:00:00

  • Association of gas cooking with children's respiratory health: results from GINIplus and LISAplus birth cohort studies.

    abstract:UNLABELLED:Previous studies have found inconsistent results on the association between asthma in children and gas cooking emissions. We aimed to assess the effects of the long-term exposure to gas cooking on the onset of asthma and respiratory symptoms, focusing on wheezing, in children from two German birth cohorts: L...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2012.00784.x

    authors: Casas L,Tischer C,Tiesler C,Brüske I,Koletzko S,Bauer CP,Wichmann HE,von Berg A,Berdel D,Krämer U,Schaaf B,Lehmann I,Herbarth O,Heinrich J,GINIplus and LISAplus Study Group.

    更新日期:2012-12-01 00:00:00

  • Association of size-fractionated indoor particulate matter and black carbon with heart rate variability in healthy elderly women in Beijing.

    abstract::Associations between size-fractionated indoor particulate matter (PM) and black carbon (BC) and heart rate variability (HRV) and heart rate (HR) in elderly women remain unclear. Twenty-nine healthy elderly women were measured for 24-hour HRV/HR indices. Real-time size-fractionated indoor PM and BC were monitored on th...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12449

    authors: Dong W,Pan L,Li H,Miller MR,Loh M,Wu S,Xu J,Yang X,Shan J,Chen Y,Deng F,Guo X

    更新日期:2018-05-01 00:00:00

  • Modeling the internal dynamics of energy and mass transfer in an imperfectly mixed ventilated airspace.

    abstract:UNLABELLED:The present paper outlines a modeling approach, which has been developed to model the internal dynamics of heat and moisture transfer in an imperfectly mixed ventilated airspace. The modeling approach, which combines the classical heat and moisture balance differential equations with the use of experimental ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00168.x

    authors: Janssens K,Van Brecht A,Zerihun Desta T,Boonen C,Berckmans D

    更新日期:2004-06-01 00:00:00

  • Indoor air pollution in developing countries: recommendations for research.

    abstract::Available studies indicate that indoor air pollution (IAP) from household cooking and space heating apparently causes substantial ill-health in developing countries where the majority of households rely on solid fuels (coal or biomass as wood, crop residues, and dung), but there are many remaining uncertainties. To pi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.01137.x

    authors: Smith KR

    更新日期:2002-09-01 00:00:00

  • Particle size distributions and concentrations of airborne endotoxin using novel collection methods in homes during the winter and summer seasons.

    abstract:UNLABELLED:A comparison study of novel collection methods for airborne bacteria and endotoxin was performed in an environmentally controlled chamber and in pilot-field studies. Airborne particulate matter was collected in swirling liquid impingers, air-monitoring filter cassettes, and with a micro-orifice uniform depos...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00419.x

    authors: Kujundzic E,Hernandez M,Miller SL

    更新日期:2006-06-01 00:00:00

  • Benefit-cost analysis of commercially available activated carbon filters for indoor ozone removal in single-family homes.

    abstract::This study involved the development of a model for evaluating the potential costs and benefits of ozone control by activated carbon filtration in single-family homes. The modeling effort included the prediction of indoor ozone with and without activated carbon filtration in the HVAC system. As one application, the mod...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12220

    authors: Aldred JR,Darling E,Morrison G,Siegel J,Corsi RL

    更新日期:2016-06-01 00:00:00

  • Human convection flow in spaces with and without ventilation: personal exposure to floor-released particles and cough-released droplets.

    abstract:UNLABELLED:The effects of the human convective boundary layer (CBL), room airflow patterns, and their velocities on personal exposure are examined. Two pollutants are studied which simulate particles released from the feet and generated at distances of 2 and 3 m by a human cough. A thermal manikin whose body shape, siz...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12177

    authors: Licina D,Melikov A,Pantelic J,Sekhar C,Tham KW

    更新日期:2015-12-01 00:00:00

  • Characterizing ultrafine particles and other air pollutants at five schools in South Texas.

    abstract:UNLABELLED:This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00738.x

    authors: Zhang Q,Zhu Y

    更新日期:2012-02-01 00:00:00

  • Measuring the exposure of infants and children to indoor air pollution from biomass fuels in The Gambia.

    abstract:UNLABELLED:Indoor air pollution (IAP) from biomass fuels contains high concentrations of health damaging pollutants and is associated with an increased risk of childhood pneumonia. We aimed to design an exposure measurement component for a matched case-control study of IAP as a risk factor for pneumonia and severe pneu...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00533.x

    authors: Dionisio KL,Howie S,Fornace KM,Chimah O,Adegbola RA,Ezzati M

    更新日期:2008-08-01 00:00:00

  • Removal of viable bioaerosol particles with a low-efficiency HVAC filter enhanced by continuous emission of unipolar air ions.

    abstract:UNLABELLED:Continuous emission of unipolar ions has been shown to improve the performance of respirators and stationary filters challenged with non-biological particles. In this study, we investigated the ion-induced enhancement effect while challenging a low-efficiency heating, ventilation and air-conditioning (HVAC) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00512.x

    authors: Huang R,Agranovski I,Pyankov O,Grinshpun S

    更新日期:2008-04-01 00:00:00

  • Relationships between estimated flame retardant emissions and levels in indoor air and house dust.

    abstract::A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12332

    authors: Liagkouridis I,Cequier E,Lazarov B,Palm Cousins A,Thomsen C,Stranger M,Cousins IT

    更新日期:2017-05-01 00:00:00

  • Air movement--good or bad?

    abstract:UNLABELLED:Air movement--good or bad? The question can only be answered by those who are exposed when they are exposed. Human perception of air movement depends on environmental factors including air velocity, air velocity fluctuations, air temperature, and personal factors such as overall thermal sensation and activit...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2004.00271.x

    authors: Toftum J

    更新日期:2004-01-01 00:00:00

  • Continuous measurement of reactive oxygen species inside and outside of a residential house during summer.

    abstract::Reactive oxygen species (ROS) are an important contributor to adverse health effects associated with ambient air pollution. Despite infiltration of ROS from outdoors, and possible indoor sources (eg, combustion), there are limited data available on indoor ROS. In this study, part of the second phase of Air Composition...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12789

    authors: Eftekhari A,Fortenberry CF,Williams BJ,Walker MJ,Dang A,Pfaff A,Ercal N,Morrison GC

    更新日期:2021-01-23 00:00:00

  • Indoor visible mold and mold odor are associated with new-onset childhood wheeze in a dose-dependent manner.

    abstract::Evidence is accumulating that indoor dampness and mold are associated with the development of asthma. The underlying mechanisms remain unknown. New Zealand has high rates of both asthma and indoor mold and is ideally placed to investigate this. We conducted an incident case-control study involving 150 children with ne...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12413

    authors: Shorter C,Crane J,Pierse N,Barnes P,Kang J,Wickens K,Douwes J,Stanley T,Täubel M,Hyvärinen A,Howden-Chapman P,Wellington Region General Practitioner Research Network.

    更新日期:2018-01-01 00:00:00

  • Cross-city comparison of indoor air temperatures in air-conditioned spaces.

    abstract::Field measurements were collected through physical measurements and observations in the cities of Seoul, Korea; Eugene and Portland, Oregon; and Yokohama, Japan, during the fall, winter, and summer seasons from 2005 to 2006. A total of 1733 data sets were collected (Seoul - 713; Oregon - 807; Yokohama - 213) in variet...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00705.x

    authors: Kim H,Chun C,Kwok A,Ota A,Tamura A

    更新日期:2011-08-01 00:00:00

  • A new exposure route to trace elements in indoor particulate matter.

    abstract::Concentrations and emission rates of sixteen trace elements in emitted PM during heating soybean oil using three types of pans, including Teflon, granitium, and cast-iron, were investigated. Statistically significant decreases in Mn and Co emission rates were observed when the oil was heated in the cast-iron pan compa...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12641

    authors: Broomandi P,Amouei Torkmahalleh M,Akturk M,Ngagine SH,Gorjinezhad S,Ozturk F,Kocak M,Kim J

    更新日期:2020-05-01 00:00:00

  • Identification of contaminant sources in enclosed environments by inverse CFD modeling.

    abstract:UNLABELLED:In case contaminants are found in enclosed environments such as aircraft cabins or buildings, it is useful to find the contaminant sources. One method to locate contaminant sources is by inverse computational fluid dynamics (CFD) modeling. As the inverse CFD modeling is ill posed, this paper has proposed to ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00452.x

    authors: Zhang TF,Chen Q

    更新日期:2007-06-01 00:00:00

  • Risk factors in heating, ventilating, and air-conditioning systems for occupant symptoms in US office buildings: the US EPA BASE study.

    abstract:UNLABELLED:Building-related symptoms in office workers worldwide are common, but of uncertain etiology. One cause may be contaminants related to characteristics of heating, ventilating, and air-conditioning (HVAC) systems. We analyzed data from 97 representative air-conditioned US office buildings in the Building Asses...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00531.x

    authors: Mendell MJ,Lei-Gomez Q,Mirer AG,Seppänen O,Brunner G

    更新日期:2008-08-01 00:00:00

  • Determination of radon exhalation from construction materials using VOC emission test chambers.

    abstract::The inhalation of (222) Rn (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available me...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12031

    authors: Richter M,Jann O,Kemski J,Schneider U,Krocker C,Hoffmann B

    更新日期:2013-10-01 00:00:00

  • Droplet fate in indoor environments, or can we prevent the spread of infection?

    abstract:UNLABELLED:When considering how people are infected and what can be done to prevent the infections, answers from many disciplines are sought: microbiology, epidemiology, medicine, engineering, and physics. There are many pathways to infection spread, and among the most significant from the epidemiological point of view...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2006.00432.x

    authors: Morawska L

    更新日期:2006-10-01 00:00:00

  • Combined use of an electrostatic precipitator and a high-efficiency particulate air filter in building ventilation systems: Effects on cardiorespiratory health indicators in healthy adults.

    abstract::High-efficiency particulate air (HEPA) filtration in combination with an electrostatic precipitator (ESP) can be a cost-effective approach to reducing indoor particulate exposure, but ESPs produce ozone. The health effect of combined ESP-HEPA filtration has not been examined. We conducted an intervention study in 89 v...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12447

    authors: Day DB,Xiang J,Mo J,Clyde MA,Weschler CJ,Li F,Gong J,Chung M,Zhang Y,Zhang J

    更新日期:2018-05-01 00:00:00

  • Early age exposure to moisture damage and systemic inflammation at the age of 6 years.

    abstract::Cross-sectional studies have shown that exposure to indoor moisture damage and mold may be associated with subclinical inflammation. Our aim was to determine whether early age exposure to moisture damage or mold is prospectively associated with subclinical systemic inflammation or with immune responsiveness in later c...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12454

    authors: Karvonen AM,Tischer C,Kirjavainen PV,Roponen M,Hyvärinen A,Illi S,Mustonen K,Pfefferle PI,Renz H,Remes S,Schaub B,von Mutius E,Pekkanen J

    更新日期:2018-05-01 00:00:00

  • Cooking fuel type, household ventilation, and the risk of acute lower respiratory illness in urban Bangladeshi children: a longitudinal study.

    abstract:UNLABELLED:Acute lower respiratory illnesses (ALRI) are the leading cause of death among children <5 years. Studies have found that biomass cooking fuels are an important risk factor for ALRI. However, few studies have evaluated the influence of natural household ventilation indicators on ALRI. The purpose of this stud...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00754.x

    authors: Murray EL,Brondi L,Kleinbaum D,McGowan JE,Van Mels C,Brooks WA,Goswami D,Ryan PB,Klein M,Bridges CB

    更新日期:2012-04-01 00:00:00