Relationships between estimated flame retardant emissions and levels in indoor air and house dust.

Abstract:

:A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) in air and dust collected in 38 indoor microenvironments in Norway. We use modeling methods to back-calculate emission rates from indoor air and dust measurements and identify possible indications of an emission-to-dust pathway. Experimentally based emission estimates provide a satisfactory indication of the relative emission strength of indoor sources. Modeling results indicate an up to two orders of magnitude enhanced emission strength for OPFRs (median emission rates of 0.083 and 0.41 μg h-1 for air-based and dust-based estimates) compared to BFRs (0.52 and 0.37 ng h-1 median emission rates). A consistent emission-to-dust signal, defined as higher dust-based than air-based emission estimates, was identified for four of the seven OPFRs, but only for one of the 19 BFRs. It is concluded, however, that uncertainty in model input parameters could potentially lead to the false identification of an emission-to-dust signal.

journal_name

Indoor Air

journal_title

Indoor air

authors

Liagkouridis I,Cequier E,Lazarov B,Palm Cousins A,Thomsen C,Stranger M,Cousins IT

doi

10.1111/ina.12332

subject

Has Abstract

pub_date

2017-05-01 00:00:00

pages

650-657

issue

3

eissn

0905-6947

issn

1600-0668

journal_volume

27

pub_type

杂志文章
  • A review of ventilation and the quality of ventilation air.

    abstract::Ventilation is pivotal in terms of securing optimum indoor air quality. In addition, it also has a major impact on energy use in buildings. It is important, therefore, that the role and impact of ventilation is fully understood and that ventilation is employed efficiently. The purpose of this paper is to review these ...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1034/j.1600-0668.2000.010003193.x

    authors: Liddament MW

    更新日期:2000-09-01 00:00:00

  • Indoor organophosphate and polybrominated flame retardants in Tokyo.

    abstract:UNLABELLED:In Japan, organophosphate and polybrominated flame retardants are used in building materials and electric appliances to protect them from fire hazards. In this study, to identify the emission sources of these flame retardants to indoor air, the migration rates (flux) of organophosphate and polybrominated fla...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00442.x

    authors: Saito I,Onuki A,Seto H

    更新日期:2007-02-01 00:00:00

  • Risk factors in heating, ventilating, and air-conditioning systems for occupant symptoms in US office buildings: the US EPA BASE study.

    abstract:UNLABELLED:Building-related symptoms in office workers worldwide are common, but of uncertain etiology. One cause may be contaminants related to characteristics of heating, ventilating, and air-conditioning (HVAC) systems. We analyzed data from 97 representative air-conditioned US office buildings in the Building Asses...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00531.x

    authors: Mendell MJ,Lei-Gomez Q,Mirer AG,Seppänen O,Brunner G

    更新日期:2008-08-01 00:00:00

  • Survey of the reliability of carbon monoxide alarms deployed in domestic homes and efficacy of use by consumers.

    abstract::Carbon monoxide (CO) alarms are extensively used in domestic premises in the UK to help protect against CO poisoning. Their expected lifetime has been increasing, and some current models now have a replacement period of more than 6 years under normal operation. However, concerns have been expressed as to the reliabili...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12022

    authors: Naylor S,Walsh PT,Dowker KP

    更新日期:2013-08-01 00:00:00

  • Comparison of two dust collection methods for reservoir indoor allergens and endotoxin on carpets and mattresses.

    abstract::Variable methods of dust collection may lead to uncertainty in the measurement of biomarkers. The purpose of this study was to examine the effect of two different dust collection devices on dust weight, Der p 1, Fel d 1, and endotoxin levels. We compared: (1) a nylon mesh sock inserted between the furniture attachment...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00253.x

    authors: Wickens K,Lane J,Siebers R,Ingham T,Crane J

    更新日期:2004-06-01 00:00:00

  • Sorptive interactions between VOCs and indoor materials.

    abstract::This study was carried out using various materials (carpet, gypsum board, upholstery, vinyl and wood flooring, acoustic tiles, and fruit) that were exposed to eight gaseous volatile organic compounds (VOCs) (isopropanol, MTBE, cyclohexane, toluene, ethylbenzene, tetrachloroethene, 1,2-dichlorobenzene, and 1,2,4-trichl...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.110406.x

    authors: Won D,Corsi RL,Rynes M

    更新日期:2001-12-01 00:00:00

  • Indoor environmental quality in a 'low allergen' school and three standard primary schools in Western Australia.

    abstract::To investigate indoor environmental quality in classrooms, assessments were undertaken in a 'low allergen' school and three standard primary schools in Western Australia. Dust allergens, air pollutants and physical parameters were monitored in the four schools at four times (summer school term, autumn holiday, winter ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00405.x

    authors: Zhang G,Spickett J,Rumchev K,Lee AH,Stick S

    更新日期:2006-02-01 00:00:00

  • Particle dose estimation from frying in residential settings.

    abstract:UNLABELLED:Fumes produced during frying have been implicated as a potential cause for the increased incidence of adenocarcinoma. Particulate matter exposure has also been linked with other pulmonary and coronary disease. This study investigated the contribution of frying in residential settings to ultrafine and fine pa...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00551.x

    authors: Evans GJ,Peers A,Sabaliauskas K

    更新日期:2008-12-01 00:00:00

  • Humidity control effect of vapor-permeable walls employing hygroscopic insulation material.

    abstract::Airtight construction and high-performance thermal insulation materials are commonly considered important building features to enhance indoor thermal comfort while reducing thermal load. However, when water vapor is generated in such airtight indoor spaces, it cannot be discharged to the outside, causing interstitial ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12622

    authors: Lee H,Ozaki A,Lee M,Yamamoto T

    更新日期:2020-03-01 00:00:00

  • Assessment of indoor HONO formation mechanisms based on in situ measurements and modeling.

    abstract::The photolysis of HONO has been found to be the oxidation driver through OH formation in the indoor air measurement campaign SURFin, an extensive campaign carried out in July 2012 in a classroom in Marseille. In this study, the INCA-Indoor model is used to evaluate different HONO formation mechanisms that have been us...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12320

    authors: Mendez M,Blond N,Amedro D,Hauglustaine DA,Blondeau P,Afif C,Fittschen C,Schoemaecker C

    更新日期:2017-03-01 00:00:00

  • Effects of energy retrofits on Indoor Air Quality in multifamily buildings.

    abstract::We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12555

    authors: Du L,Leivo V,Prasauskas T,Täubel M,Martuzevicius D,Haverinen-Shaughnessy U

    更新日期:2019-07-01 00:00:00

  • Oxygenated VOCs, aqueous chemistry, and potential impacts on residential indoor air composition.

    abstract::Dampness affects a substantial percentage of homes and is associated with increased risk of respiratory ailments; yet, the effects of dampness on indoor chemistry are largely unknown. We hypothesize that the presence of water-soluble gases and their aqueous processing alters the chemical composition of indoor air and ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12422

    authors: Duncan SM,Sexton KG,Turpin BJ

    更新日期:2018-01-01 00:00:00

  • Exercise-induced effects on a gym atmosphere.

    abstract::We report results of analysis of a month-long measurement of indoor air and environment quality parameters in one gym during sporting activities such as football, basketball, volleyball, badminton, boxing, and fitness. We have determined an average single person's contribution to the increase of temperature, humidity,...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12226

    authors: Žitnik M,Bučar K,Hiti B,Barba Ž,Rupnik Z,Založnik A,Žitnik E,Rodrìguez L,Mihevc I,Žibert J

    更新日期:2016-06-01 00:00:00

  • Performance evaluation of a novel personalized ventilation-personalized exhaust system for airborne infection control.

    abstract::In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)-personalized exhaust (PE) system...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12127

    authors: Yang J,Sekhar SC,Cheong KW,Raphael B

    更新日期:2015-04-01 00:00:00

  • Indoor thermal stratification and its statistical distribution.

    abstract::Thermal stratification is established when warmer air rises and cooler air descends under thermal buoyancy. It occurs in indoor environment situations including large warehouse-type buildings, buoyancy-driven ventilated spaces with displacement, underfloor ventilation, and/or natural ventilation, and enclosure fires w...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12520

    authors: Wang LL,Zhang X,Qi D

    更新日期:2019-03-01 00:00:00

  • Indoor ozone/human chemistry and ventilation strategies.

    abstract::This study aimed to better understand and quantify the influence of ventilation strategies on occupant-related indoor air chemistry. The oxidation of human skin oil constituents was studied in a continuously ventilated climate chamber at two air exchange rates (1 h-1 and 3 h-1 ) and two initial ozone mixing ratios (30...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12594

    authors: Salvador CM,Bekö G,Weschler CJ,Morrison G,Le Breton M,Hallquist M,Ekberg L,Langer S

    更新日期:2019-11-01 00:00:00

  • A study of the dispersion of expiratory aerosols in unidirectional downward and ceiling-return type airflows using a multiphase approach.

    abstract::Dispersion characteristics of expiratory aerosols were investigated in an enclosure with two different idealized airflow patterns: the ceiling-return and the unidirectional downward. A multiphase numerical model, which was able to capture the polydispersity and evaporation features of the aerosols, was adopted. Experi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00426.x

    authors: Chao CY,Wan MP

    更新日期:2006-08-01 00:00:00

  • Continuous measurement of reactive oxygen species inside and outside of a residential house during summer.

    abstract::Reactive oxygen species (ROS) are an important contributor to adverse health effects associated with ambient air pollution. Despite infiltration of ROS from outdoors, and possible indoor sources (eg, combustion), there are limited data available on indoor ROS. In this study, part of the second phase of Air Composition...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12789

    authors: Eftekhari A,Fortenberry CF,Williams BJ,Walker MJ,Dang A,Pfaff A,Ercal N,Morrison GC

    更新日期:2021-01-23 00:00:00

  • Removal of contaminants released from room surfaces by displacement and mixing ventilation: modeling and validation.

    abstract:UNLABELLED:This paper presents the experimental and numerical modeling of contaminant dispersion in a full-scale environmental chamber with different room air distribution systems. For the experimental modeling, an area source with uniform emissions of a hypothetical contaminant (SF6) from the entire floor surface is d...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00383.x

    authors: He G,Yang X,Srebric J

    更新日期:2005-10-01 00:00:00

  • Experimental validation of a computational fluid dynamics model for IAQ applications in ice rink arenas.

    abstract::Many ice rink arenas have ice resurfacing equipment that uses fossil fuel as power. The combustion byproducts are a major source of contamination. Ventilation along with other pollution source control measures is the most widely applied strategy to lower the contaminant level below the threshold limit and maintain acc...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.110206.x

    authors: Yang C,Demokritou P,Chen Q,Spengler J

    更新日期:2001-06-01 00:00:00

  • Evaluation of ionic air purifiers for reducing aerosol exposure in confined indoor spaces.

    abstract:UNLABELLED:Numerous techniques have been developed over the years for reducing aerosol exposure in indoor air environments. Among indoor air purifiers of different types, ionic emitters have gained increasing attention and are presently used for removing dust particles, aeroallergens and airborne microorganisms from in...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00364.x

    authors: Grinshpun SA,Mainelis G,Trunov M,Adhikari A,Reponen T,Willeke K

    更新日期:2005-08-01 00:00:00

  • Organic compounds as indicators of air pollution.

    abstract::The most important indoor air pollutants have already been addressed with individual national guidelines or recommendations. However, an international set of guidelines or recommendations for indoor air quality (IAQ) is needed for these pollutants based on general and uniform rules for setting such standards. A major ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.13.s.6.2.x

    authors: Mølhave L

    更新日期:2003-01-01 00:00:00

  • Human convection flow in spaces with and without ventilation: personal exposure to floor-released particles and cough-released droplets.

    abstract:UNLABELLED:The effects of the human convective boundary layer (CBL), room airflow patterns, and their velocities on personal exposure are examined. Two pollutants are studied which simulate particles released from the feet and generated at distances of 2 and 3 m by a human cough. A thermal manikin whose body shape, siz...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12177

    authors: Licina D,Melikov A,Pantelic J,Sekhar C,Tham KW

    更新日期:2015-12-01 00:00:00

  • Effects of cigarette smoking and biomass fuel on lung function and respiratory symptoms in middle-aged adults and the elderly in Guangdong province, China: A cross-sectional study.

    abstract::We sought to investigate the association between active cigarette smoking (ex- and current smokers) with or without exposure to biomass fuels and respiratory symptoms/lung function in middle-aged adults and the elderly. In the chronic obstructive pulmonary disease surveillance conducted in six cities of Guangdong prov...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12671

    authors: Zheng XY,Li ZL,Li C,Guan WJ,Li LX,Xu YJ

    更新日期:2020-09-01 00:00:00

  • Responding to sudden pollutant releases in office buildings: 1. Framework and analysis tools.

    abstract::We describe a framework for developing response recommendations to unexpected toxic pollutant releases in commercial buildings. It may be applied in conditions where limited building- and event-specific information is available. The framework is based on a screening-level methodology to develop insights, or rules-of-t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00183.x

    authors: Sohn MD,Sextro RG,Gadgil AJ,Daisey JM

    更新日期:2003-09-01 00:00:00

  • Indoor/outdoor relationships of carbon monoxide and oxides of nitrogen in domestic homes with roadside, urban and rural locations in a central Indian region.

    abstract:UNLABELLED:Indoor air quality (IAQ) has been a matter of public concern these days whereas air pollution is normally monitored outdoors as part of obligations under the National air quality strategies. Much little is known about levels of air pollution indoors. Simultaneous measurements of indoor and outdoor carbon mon...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00311.x

    authors: Lawrence AJ,Masih A,Taneja A

    更新日期:2005-04-01 00:00:00

  • Polybrominated diphenyl ether (PBDE) concentrations and resulting exposure in homes in California: relationships among passive air, surface wipe and dust concentrations, and temporal variability.

    abstract::Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12130

    authors: Bennett DH,Moran RE,Wu XM,Tulve NS,Clifton MS,Colón M,Weathers W,Sjödin A,Jones R,Hertz-Picciotto I

    更新日期:2015-04-01 00:00:00

  • Spatiotemporally resolved black carbon concentration, schoolchildren's exposure and dose in Barcelona.

    abstract::At city level, personal monitoring is the best way to assess people's exposure. However, it is usually estimated from a few monitoring stations. Our aim was to determine the exposure to black carbon (BC) and BC dose for 45 schoolchildren with portable microaethalometers and to evaluate the relationship between persona...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12214

    authors: Rivas I,Donaire-Gonzalez D,Bouso L,Esnaola M,Pandolfi M,de Castro M,Viana M,Àlvarez-Pedrerol M,Nieuwenhuijsen M,Alastuey A,Sunyer J,Querol X

    更新日期:2016-06-01 00:00:00

  • Indoor gaseous air pollutants determinants in office buildings-The OFFICAIR project.

    abstract::The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12609

    authors: Spinazzè A,Campagnolo D,Cattaneo A,Urso P,Sakellaris IA,Saraga DE,Mandin C,Canha N,Mabilia R,Perreca E,Mihucz VG,Szigeti T,Ventura G,de Oliveira Fernandes E,de Kluizenaar Y,Cornelissen E,Hänninen O,Carrer P,Wolkoff P

    更新日期:2020-01-01 00:00:00

  • A simplified approach to describe complex diffusers in displacement ventilation for CFD simulations.

    abstract:UNLABELLED:With the capability to improve indoor air quality while simultaneously reducing energy demand, displacement ventilation is becoming popular. However, the numerical simulation of air distribution in an indoor space with displacement ventilation using computational fluid dynamics (CFD) is challenging because o...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2009.00590.x

    authors: Zhang TT,Lee K,Chen QY

    更新日期:2009-06-01 00:00:00