Abstract:
:We report results of analysis of a month-long measurement of indoor air and environment quality parameters in one gym during sporting activities such as football, basketball, volleyball, badminton, boxing, and fitness. We have determined an average single person's contribution to the increase of temperature, humidity, and dust concentration in the gym air volume of 12500 m(3) : during 90-min exercise performed at an average heart rate of 143 ± 10 bpm, a single person evaporated 0.94 kg of water into the air by sweating, contributed 0.03 K to the air temperature rise and added 1.5 μg/m(3) and 5 ng/m(3) to the indoor concentration of inhalable particles (PM10 ) and Ca concentration, respectively. As the breathing at the observed exercise intensity was about three times faster with respect to the resting condition and as the exercise-induced PM10 concentration was about two times larger than outdoors, a sportsman in the gym would receive about a sixfold higher dose of PM10 inside than he/she would have received at rest outside.
journal_name
Indoor Airjournal_title
Indoor airauthors
Žitnik M,Bučar K,Hiti B,Barba Ž,Rupnik Z,Založnik A,Žitnik E,Rodrìguez L,Mihevc I,Žibert Jdoi
10.1111/ina.12226subject
Has Abstractpub_date
2016-06-01 00:00:00pages
468-77issue
3eissn
0905-6947issn
1600-0668journal_volume
26pub_type
杂志文章相关文献
INDOOR AIR文献大全abstract::The photolysis of HONO has been found to be the oxidation driver through OH formation in the indoor air measurement campaign SURFin, an extensive campaign carried out in July 2012 in a classroom in Marseille. In this study, the INCA-Indoor model is used to evaluate different HONO formation mechanisms that have been us...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12320
更新日期:2017-03-01 00:00:00
abstract::This article reports the results of an investigation, based on fundamental fluid dynamics and mass transfer theory, carried out to obtain a general understanding of the mechanisms involved in the emissions from building materials in ventilated rooms. In addition, a generally applicable method for the prediction of sur...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2001.011003162.x
更新日期:2001-09-01 00:00:00
abstract::Indoor air quality (IAQ), as determined by the concentrations of indoor air pollutants, can be predicted using either physically based mechanistic models or statistical models that are driven by measured data. In comparison with mechanistic models mostly used in unoccupied or scenario-based environments, statistical m...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/ina.12580
更新日期:2019-09-01 00:00:00
abstract::A nationwide cross-sectional study of 3335 employees was conducted in 320 offices in Japan to estimate the prevalence of building-related symptoms (BRSs) and determine the risk factors related to work environment, Indoor Air Quality, and occupational stress. Data were collected through self-administered questionnaires...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12158
更新日期:2015-10-01 00:00:00
abstract:UNLABELLED:In studying productivity, effects of environmental factors have focused only on performance. However, previous studies of the impact of the environment upon performance of mental tasks generally conclude that productivity research is somewhat confusing because the results are sometimes conflicting. In experi...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00281.x
更新日期:2004-01-01 00:00:00
abstract::This paper characterizes the relationship between occupant activities and indoor air particulate levels in a non-smoking office building. Occupant activities were recorded on video. Particulate concentrations were monitored by three optical particle counters (OPCs) in five size ranges at three heights. Particulate mas...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2001.011001035.x
更新日期:2001-03-01 00:00:00
abstract:UNLABELLED:Indoor air quality (IAQ) has been a matter of public concern these days whereas air pollution is normally monitored outdoors as part of obligations under the National air quality strategies. Much little is known about levels of air pollution indoors. Simultaneous measurements of indoor and outdoor carbon mon...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00311.x
更新日期:2005-04-01 00:00:00
abstract::At city level, personal monitoring is the best way to assess people's exposure. However, it is usually estimated from a few monitoring stations. Our aim was to determine the exposure to black carbon (BC) and BC dose for 45 schoolchildren with portable microaethalometers and to evaluate the relationship between persona...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12214
更新日期:2016-06-01 00:00:00
abstract::This study aimed to measure in French children personal exposure concentrations of black carbon (BC) and ultrafine particles (UFP) and to quantify the contribution of different microenvironments (home, school, places of extracurricular activities, transport) to their total exposure. It was conducted on 96 9-year-old c...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12358
更新日期:2017-07-01 00:00:00
abstract::It has not yet been possible to quantify dose-related health risks attributable to indoor dampness or mold (D/M), to support setting specific health-related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of q...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/ina.12464
更新日期:2018-07-01 00:00:00
abstract:UNLABELLED:Building-related symptoms in office workers worldwide are common, but of uncertain etiology. One cause may be contaminants related to characteristics of heating, ventilating, and air-conditioning (HVAC) systems. We analyzed data from 97 representative air-conditioned US office buildings in the Building Asses...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2008.00531.x
更新日期:2008-08-01 00:00:00
abstract:UNLABELLED:Meteorological factors such as relative humidity directly correlate with airborne fungal levels outdoors and indoors. While dehumidification alone is effective at reducing moisture necessary for mold growth, it is inadequate as a single intervention as it does not remove viable and non-viable fungal spores t...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00379.x
更新日期:2005-12-01 00:00:00
abstract::In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)-personalized exhaust (PE) system...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12127
更新日期:2015-04-01 00:00:00
abstract:UNLABELLED:We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10-15 LPM in 19 New York City apartments in which an asthmatic child...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00728.x
更新日期:2011-12-01 00:00:00
abstract:UNLABELLED:In the two decades since the first issue of Indoor Air, there have been over 250 peer-reviewed publications addressing chemical reactions among indoor pollutants. The present review has assembled and categorized these publications. It begins with a brief account of the state of our knowledge in 1991 regardin...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0668.2011.00713.x
更新日期:2011-06-01 00:00:00
abstract::A portion of electronic equipment failures is a consequence of particle deposition on electronic circuits in normal indoor environments. Deposited hygroscopic particles reduce the electrical isolation (EI) between conductors. In laboratory experiments, we investigated the mechanisms, locations, and effects of particle...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2000.010001047.x
更新日期:2000-03-01 00:00:00
abstract:UNLABELLED:Ventilation performance and pollutant distribution in a traditional ceiling-type ventilation system, a top-return (TR)-type and a floor-return (FR)-type underfloor ventilation systems were performed in a controlled experimental room. Tracer gas method was utilized to determine the age of air and the contamin...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00248.x
更新日期:2004-10-01 00:00:00
abstract:UNLABELLED:In Japan, organophosphate and polybrominated flame retardants are used in building materials and electric appliances to protect them from fire hazards. In this study, to identify the emission sources of these flame retardants to indoor air, the migration rates (flux) of organophosphate and polybrominated fla...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2006.00442.x
更新日期:2007-02-01 00:00:00
abstract:UNLABELLED:Measurements of combustion product concentrations were taken in 30 homes where unvented gas fireplaces were used. Measurements of CO, CO(2), NO(x), NO(2) , O(2) (depletion), and water vapor were taken at 1-min interval. The analyzers were calibrated with certified calibration gases for each placement and wer...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2010.00659.x
更新日期:2010-10-01 00:00:00
abstract::There is growing awareness that indoor exposure to particulate matter with diameter ≤ 2.5 μm (PM2.5 ) is associated with an increased risk of adverse health effects. Cooking is a key indoor source of PM2.5 and an activity conducted daily in most homes. Population scale models can predict occupant exposures to PM2.5 , ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12542
更新日期:2019-05-01 00:00:00
abstract::We determined the moisture levels, relative humidity (RH) or moisture content (MC) of materials, and concentrations of culturable fungi, actinomycetes and total spores as well as a composition of fungal flora in 122 building material samples collected from 18 moisture problem buildings. The purpose of this work was to...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2000.010002111.x
更新日期:2000-06-01 00:00:00
abstract:UNLABELLED:Quasi-ultrafine (quasi-UF) particulate matter (PM(0.25)) and its components were measured in indoor and outdoor environments at four retirement communities in Los Angeles Basin, California, as part of the Cardiovascular Health and Air Pollution Study (CHAPS). The present paper focuses on the characterization...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2009.00620.x
更新日期:2010-02-01 00:00:00
abstract::Dispersion characteristics of expiratory aerosols were investigated in an enclosure with two different idealized airflow patterns: the ceiling-return and the unidirectional downward. A multiphase numerical model, which was able to capture the polydispersity and evaporation features of the aerosols, was adopted. Experi...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2006.00426.x
更新日期:2006-08-01 00:00:00
abstract::This study aimed to better understand and quantify the influence of ventilation strategies on occupant-related indoor air chemistry. The oxidation of human skin oil constituents was studied in a continuously ventilated climate chamber at two air exchange rates (1 h-1 and 3 h-1 ) and two initial ozone mixing ratios (30...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12594
更新日期:2019-11-01 00:00:00
abstract:UNLABELLED:This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvi...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00738.x
更新日期:2012-02-01 00:00:00
abstract::A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12332
更新日期:2017-05-01 00:00:00
abstract::Evidence is accumulating that indoor dampness and mold are associated with the development of asthma. The underlying mechanisms remain unknown. New Zealand has high rates of both asthma and indoor mold and is ideally placed to investigate this. We conducted an incident case-control study involving 150 children with ne...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12413
更新日期:2018-01-01 00:00:00
abstract::Thermal stratification is established when warmer air rises and cooler air descends under thermal buoyancy. It occurs in indoor environment situations including large warehouse-type buildings, buoyancy-driven ventilated spaces with displacement, underfloor ventilation, and/or natural ventilation, and enclosure fires w...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12520
更新日期:2019-03-01 00:00:00
abstract:UNLABELLED:This paper presents the experimental and numerical modeling of contaminant dispersion in a full-scale environmental chamber with different room air distribution systems. For the experimental modeling, an area source with uniform emissions of a hypothetical contaminant (SF6) from the entire floor surface is d...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00383.x
更新日期:2005-10-01 00:00:00
abstract::Ultrafine particles are observed when metal surfaces, such as heating elements in electric appliances, or even empty cooking pans, are heated. The source of the particles has not been identified. We present evidence that particles >10 nm are not emitted directly from the heating elements or the metal surfaces. Using r...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12163
更新日期:2015-10-01 00:00:00